Similar documents
Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

User Manual. Ellipse Pitot Tube Meter. PFA Fire Pump System. PTT-UM EN-03 (March 2017) 2500 GPM 3000 F M

Rosemount 3051CFA Annubar Flowmeter

KB Series self averaging pitot flowmeter for gas, liquids and steam flows

Transmitting Transducer. Gas/Air Velocity Range:

Model Specifications V400S V400D Sensor Code Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy

Manifold and Isolation Valve Mounting System for Direct Mounting DP Transmitters

Datasheet Rev.3 Feb 2015 Venturi tube

Rosemount 285 Annubar Primary Element Series

Datasheet Rev.1 Feb 2014 High precision flowmeter

Differential Pressure - Primary Flow Element Wedgemeter II Series WM: C/F/P

TRANSMITTER ATTACHES TO THIS SURFACE

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Control Valve. 3-Piece 30, 60, or 1/8" Slotted Port. General Chemical. Industrial. Power INLINE BALLVALVE.COM

Signet Conductivity/Resistivity Electrodes

Rosemount DP Flowmeters and Primary Elements

VERIS FLOW MEASUREMENT GROUP

V550 Spring Lock Flanged Connection with Packing Gland

V200S. ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 150# 150# 600# 600# Drive Rods Single Double (150mm-1050mm)

Signet Conductivity/Resistivity Electrodes

StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems

Rosemount 3051T In-Line Pressure Transmitter

FICHA TÉCNICA DE PRODUTO

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev LA Catalog Contents

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement

505F Multi-Port Ball Valve

SECTION METERS AND GAGES FOR HVAC PIPING

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

Armstrong In-Line and Insertion Vortex Flow Meters

FPD350 Torbar Averaging pitot tubes

Purge Adapters. The Solution to Isolate the Process. Flow, Level and Pressure Applications: Product Features: Contact Information:

TY-FLO 3 Piece Ball Valves

TY-FLO 3 Piece Ball Valves

INTRODUCTION AND STANDARD SPECIFICATIONS

ABB MEASUREMENT & ANALYTICS DATA SHEET. FPD350 Torbar Averaging pitot tubes

KDM ARMORED FLOW METER & SWITCH

TY-FLO 3 Piece Ball Valves

General Specifications

F-2700 SERIES INSERTION VORTEX FLOW METER

Rosemount 3051 Pressure Transmitter

Instrument Manifolds. V, VB, and VL Series. 2-, 3-, and 5-valve instrument manifolds

MODEL 200 MULTI-JET FLOW METER

ANDERSON GREENWOOD M4AP/M4TP STATIC PRESSURE MANIFOLDS

P3M3H, P6M3H 3-VALVE HARD SEAT MANIFOLD

STEEMCO Flowmeter for Steam

Accessories Guide ph/orp/conductivity Sensors

ANDERSON GREENWOOD LARGE BORE INTELLIMOUNT SYSTEM

SERIES 17 3 & 4 WAY BALL VALVE

ABB measurement & analytics data sheet. Model M26 Manifold line for 266 pressure transmitters

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

General Specifications

Signet 3719 ph/orp Wet-Tap Assembly

Product Data Sheet , Rev GA Catalog Content

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

TELEDYNE HASTINGS INSTRUMENTS

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Introduction. Application & Installation. Integral Block & Bleed Valves

Liquid Conductivity Two & Four Electrode Sensors

F-2700 SERIES INSERTION VORTEX FLOW METER

ORIMAS Mass Flowmeter

Rosemount 1195 Integral Orifice Primary Element

IFOA Integral Flow Orifice Assembly

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

10000 SERIES. Steam Desuperheater With Spray Nozzles

Manual & Automated Ball Valves

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

VORTEX IN-LINE FLOW METERS

F-1500 SERIES INSERTION TURBINE FLOW METER

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Flow meters, Flow switches and Flow transmitters

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

MANIFOLDS VALVE. Mfg & Exp. : Valves & Fittings. A Trusted Name in Valves and Fittings ISO 9001:2008 COMPANY. Catalogue No.

TRUNNION BALL VALVES. TBV 7.10

TBV Series Diverter and three-way ball valve

Differential Pressure Gauges (701P Series)

We Are the Worldwide Provider for All Your Valve and Fitting Needs

Rosemount DP Flowmeters and Primary Elements

Recognized globally for our quality, service and the ability to deliver! ISO 9001: Quality Service Experience

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

197C. Valve Group. Series Farris Engineering Pressure Relief Valves

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev NB January Contents

DIAPHRAGM SEALS Measuring your world since 1965

Manifold Accessories. Catalog 4190-FP-ACC May 2007

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Flow meters, Flow switches and Flow transmitters

ORIFICE PLATE flow meters

Rosemount 3051 Pressure Transmitter

DM4500 Series. Three Piece Direct Mount Ball Valves STANDARDS FEATURES & BENEFITS OPTIONS

Ball Valves. Seal Welded Style BVS2...2 Carbon Steel Technical Data 2200 PSI ¼ Stainless Steel Technical Data 2160 PSI ¼

HOKE Monoflange Valves. Primary Isolation Valves

115 Series, Needle Valves, Single Block, Male x Male

VALVES & CONTROLS ANDERSON GREENWOOD INSTRUMENTATION PRODUCTS LARGE BORE INTELLIMOUNT SYSTEM

Regular Models. V150 Spring Lock Threaded Components

Model RVL-20. Stainless Steel Low-Pressure Diaphragm Relief Valve

flow measurement solutions RIM10 series rotor insertion flowmeters

IN-LINE DISC & PISTON VALVES

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

Transcription:

F L O W M E T E R I N G E Q U I P M E N T Model AR Ellipse Annular Flow Meter Preso s patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement devices. This differential pressure flow meter is designed with a series of ports facing the upstream velocity pressures, as well as flow sensing ports strategically located ahead of the trailing edge flow separation. Features Patented elliptical design outperforms traditional devices Single point pipe entry for DP, temperature and static pressure No dampening software required Lowest pressure loss in industry (typically 3% of DP in a 12" line) due to its patented aerodynamic profile NIST traceable calibration: Optional independent labs Benefits Accuracy: ±0.75% of reading, repeatability: ±0.1% of reading Turndown Ratio: 17:1; no vacuum effects No moving parts equals long, trouble-free service life True static pressure measurement rather than a calculated value Overcomes loss of accuracy caused by fluid separation at the sensor body The multi-ported, self averaging flow element consists of an elliptical shape with two independent flow sensing chambers. The impact velocity (high pressure) are located along the leading edge and the true static (low pressure) are on the exterior probe side. Model AR comes with instrument shut-off valves with provisions to accept a transmitter or direct indicating meter. RAINE FEDERATED IN. ISO 9001 : 2000 FILE N0. A6856 True static Impact velocity 1-800-632-7337 Specifications Applications: Liquids and Gases s: 2 to 72 inches (50 to 1830 mm) Pressure: 800 PSI (5515 kpa) max. Temperature: 800 F (426 ) max. Accuracy: ± 0.75% of reading Turndown Ratio: 17:1 with no vacuum effect Standard omponents: Reynolds Number: Resonance: T-type head, 316 SS ¼" or ½" FNPT connection S compression fitting with SS ferrule S 3000 lb. weld fitting ASTM A105 316/316L SS Ellipse sensor Instrument valves (2 per sensor) ¼", S 316 SS ID tag with wire Greater than 75,000 maintains most accurate flow measurements Less than 75,000 consult factory for estimated results If greater than 0.8, use double support www.preso.com

Model AR Ellipse Annular Flow Meter Part Number onstruction: PARO (1/2") PAR (") PAR1 (") (PAR/PAR0) A) 2 inch B) 2-1/2 inch ) 3 inch D) 3-1/2 inch E) 4 inch F) 5 inch G) 6 inch H) 8 inch I) 10 inch J) 12 inch K) 14 inch L) 16 inch M) 18 inch N) 20 inch O) 24 inch P) 30 inch Q) 36 inch (PAR1) A) 12 inch B) 14 inch ) 16 inch D) 18 inch E) 20 inch F) 24 inch G) 30 inch H) 36 inch I) 42 inch J) 48 inch K) 60 inch L) 72 inch NOTE: PAR0 installs on pipe sizes 2" through 5" only (A through F options) A) Std J) 160 B) 20 K) XH ) 30 L) XXH D) 40 M) 5S E) 60 N) 10S F) 80 O) 40S G) 100 P) 80S H) 120 I) 140 Pipe Orientation A) Horizontal B) Vertical Probe Material 1) 316/316L-SS 2) Monel 3) Inconel 4) Hastelloy X) Other (consult factory to review application) onnection (PAR/PAR1) A) S ompression Fitting w/ss Ferrule B) SS ompression Fitting w/ss Ferrule onnection (PAR0) A) SS ompression Fitting w/ss Ferule (PAR/PAR1) A) 1/2" NPT B) 1/2" Socket ) TT3 (Integral 3 Valve D) TT5 (Integral 5 Valve E) Transmitter Flange onnection (PAR0) A) 1/4" NPT Pipe Mounting 1) A105 S 3000# 2) 316/316L SS 150# 3) 316/316L SS 3000# 4) A105 S 3000# (see below) 5) 316/316L SS 150# 6) 316/316L SS 3000# Instrument Valve* (PAR/PAR1) A) 1/2" Needle S B) 1/2" Needle SS Instrument Valve* (PAR0) A) 1/4" Needle S B) 1/4" Needle SS *NOTE: Transmitter Flange onnection Options available when Option E under is selected. (consult factory for information) RTD 1) 100 Ohm RTD 3 wire w/ Explosion Proof Head 2) 100 Ohm RTD 3 wire, Integral w/aluminum Head Dimensions (inches) Probe Length A B AR0 4.188 2.250 AR 6.625 3.125 AR1 6.625 3.125 Probe Width AR0.5 AR.875 AR1 1.25 B A PIPE I.D. Maximum Allowable DP (Inches of Water olumn) (inches) 2 2-1/2 3 3-1/2 4 5 6 8 10 12 14 16 18 20 24 26 30 32 36 42 Single Support 880 525 396 283 197 153 126 114 100 87 53 240 175 147 113 90 74 68 50 34 Double Support 2380 1568 1283 1117 980 757 689 512 250 195 960 700 585 450 295 270 215 155 FLOW METERING EQUIPMENT 8635 Washington Avenue Racine, WI 53406-3738 USA Tel: (262) 639-6770 Fax: (262) 417-1148 Toll Free: (800) 632-7337 Preso and Ellipse are registered trademarks of Racine Federated Inc. Inconel is a registered trademark of Special Metals orporation Hastelloy is a registered trademark of Haynes International Form No. 4-25-01 AR Rev. 1/07 Printed in USA

F L O W M E T E R I N G E Q U I P M E N T Model AF Ellipse Pitot Tube Annular Flanged Flow Meter Preso s patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement devices. This differential pressure flow meter is designed with a series of ports facing the upstream velocity pressures, as well as flow sensing ports strategically located ahead of the trailing edge flow separation. Features Patented elliptical design outperforms traditional devices Single point pipe entry for DP, temperature and static pressure No dampening software required Lowest pressure loss in industry (typically 3% of DP in a 12" line) due to its patented aerodynamic profile NIST traceable calibration: Optional independent labs Benefits Accuracy: ±0.75% of reading, repeatability: ±0.1% of reading Turndown Ratio: 17:1; no vacuum effects No moving parts equals long, trouble-free service life True static pressure measurement rather than a calculated value Overcomes loss of accuracy caused by fluid separation at the sensor body The multi-ported, self averaging flow element consists of an elliptical shape with two independent flow sensing chambers. The impact velocity (high pressure) are located along the leading edge and the true static (low pressure) are on the exterior probe side. Model AF comes with instrument shut-off valves with connections to accept a transmitter or direct indicating meter. ISO ERTIFIED 9001: 2000 True static Impact velocity 1-800-632-7337 Specifications Applications: Air, Liquids and Gases s: 2 to 72 inches (50 to 1830 mm) Pressure: Vary per flange ratings Temperature: Vary per flange ratings Accuracy: ± 0.75% of reading Turndown Ratio: 17:1 with no vacuum effect Standard omponents: Reynolds Number: Resonance: T-type head, 316 SS ¼" or ½" FNPT connection S 3000 lb. weld fitting ASTM A105 316/316L SS Ellipse sensor Instrument valves (2 per sensor) ½", S 316 SS ID tag with wire 150 lbs. 316/316L SS sensor flange S gasket with SS spiral wound ring S mounting flange, 150 lbs. ASTM A 105 with nuts and bolts Greater than 75,000 maintains most accurate flow measurements Less than 75,000 consult factory for estimated results If greater than 0.8, use double support per ASME PT 19.3 www.preso.com

Model AF Ellipse Pitot Tube Annular Flanged Flow Meter Part Number onstruction: PAFO(1/2") PAF (") PAF1 (") PAF2 (2-1/4") (PAF/PAF0) A) 2 inch B) 2-1/2 inch ) 3 inch D) 3-1/2 inch E) 4 inch F) 5 inch G) 6 inch H) 8 inch I) 10 inch J) 12 inch K) 14 inch L) 16 inch M) 18 inch N) 20 inch O) 24 inch P) 30 inch Q) 36 inch (PAF1/PAF2) A) 12 inch B) 14 inch ) 16 inch D) 18 inch E) 20 inch F) 24 inch G) 30 inch H) 36 inch I) 42 inch J) 48 inch K) 60 inch L) 72 inch NOTE: PAF0 installs on pipe sizes 2" through 5" only (A through F options) Pipe Orientation A) Horizontal B) Vertical (PAF0) A) Std/40/40S B) 80/80S/XS ) 160 D) XXH E) 5S F) 10S Probe Material 1) 316/316L-SS 2) Monel 3) Inconel 4) Hastelloy X) Other (consult factory to review application) (PAF/PAF1/PAF2) A) Std G) 100 L) XXH B) 20 H) 120 M) 5S ) 30 I) 140 N) 10S D) 40 J) 160 O) 40S E) 60 K) XH P) 80S F) 80 (PAF/PAF1/PAF2) A) 1/2" NPT B) 1/2" Socket ) TT3 (Integral 3 Valve D) TT5 (Integral 5 Valve E) Transmitter Flange onnection (PAF0) A) 1/4" NPT onnection PAF0 PAF PAF1 PAF2 A) ¾" B) ¾" ) ¾" D) ¾" E) ¾" F) ¾" G) ¾" H) ¾" " " " " " " " " Pipe Mounting 1) A105 S 3000# 2) 316/316L SS 3000# 3) A105 S 3000# (see below) 4) 316/316L SS 3000# RF Flange 150# S RF Flange 300# S RF Flange 600# S RF Flange 900/1500# S RF Flange 150# SS RF Flange 300# SS RF Flange 600# SS RF Flange 900/1500# SS Instrument Valve* (PAF/PAF1/PAF2) A) 1/2" Needle S B) 1/2" Needle SS ) 1/2" Gate S D) 1/2" Gate SS Instrument Valve (PAF0) A) 1/4" Needle S B) 1/4" Needle SS *NOTE: Transmitter Flange onnection Options available when Option E under is selected. (consult factory for information) RTD 1) 100 Ohm RTD 3 wire w/ Explosion Proof Head 2) 100 Ohm RTD 3 wire, Integral w/aluminum Head Dimensions (inches) Probe Length A B AF0 6.62 3.13 AF 8.00 3.13 AF1 8.75 3.13 *AF2 13.92 N/A Probe Width AF0.5 AF.875 AF1 1.25 *AF2 2.25 *AF2 probe design not pictured contact factory for more information B A PIPE I.D. Maximum Allowable DP (Inches of Water olumn) (inches) 2 2-1/2 3 3-1/2 4 5 6 8 10 12 14 16 18 20 24 26 30 32 36 42 880 525 396 283 197 153 126 114 100 87 53 Single Support 240 175 147 113 90 74 68 50 34 2-1/4 779 660 610 495 410 346 218 187 136 105 85 Double Support 2380 1568 1283 1117 980 757 689 512 250 195 960 700 585 450 295 270 215 155 2-1/4 952 878 780 550 410 350 FLOW METERING EQUIPMENT Division of Racine Federated Inc. 8635 Washington Avenue Racine, WI 53406-3738 USA Tel: (262) 639-6770 Fax: (262) 417-1148 Toll Free: (800) 632-7337 Preso and Ellipse are registered trademarks of Racine Federated Inc. Inconel and Monel are registered trademarks of Special Metals orporation Hastelloy is a registered trademark of Haynes International Form No. 4-25-01 AF Rev. 6/07 Printed in USA

F L O W M E T E R I N G E Q U I P M E N T Model AS Ellipse Annular Flow Meter Preso s patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement devices. This differential pressure flow meter is designed with a series of ports facing the upstream velocity pressures, as well as flow sensing ports strategically located ahead of the trailing edge flow separation. Features Patented elliptical design outperforms traditional devices Single point pipe entry for DP, temperature and static pressure No dampening software required Lowest pressure loss in industry (typically 3% of DP in a 12" line) due to its patented aerodynamic profile NIST traceable calibration: Optional independent labs Benefits Accuracy: ±0.75% of reading, repeatability: ±0.1% of reading Turndown ratio: 17:1; no vacuum effects No moving parts equals long, trouble-free service life True static pressure measurement rather than a calculated value Overcomes loss of accuracy caused by fluid separation at the sensor body The multi-ported, self averaging flow element consists of an elliptical shape with two independent flow sensing chambers. The impact velocity (high pressure) are located along the leading edge and the true static (low pressure) are on the exterior probe side. Model AS comes with instrument shut-off valves with provisions to accept a transmitter or direct indicating meter. True static ISO ERTIFIED 9001: 2000 Impact velocity 1-800-632-7337 Specifications Applications: Steam s: 2 to 48 inches (50 to 1220 mm) Pressure: 600 PSI (4100 kpa) max. Temperature: 480 F (250 ) max. Accuracy: ± 0.75% of reading Turndown Ratio: 17:1 with no vacuum effect Standard omponents: Reynolds Number: Resonance: T-type head, 316 SS ½" FNPT connection S compression fitting with SS ferrule S 3000 lb. weld fitting ASTM A105 316/316L SS Ellipse sensor 316 SS ID tag with wire Greater than 75,000 maintains most accurate flow measurements Less than 75,000 consult factory for estimated results If greater than 0.8, use double support www.preso.com

Model AS Ellipse Annular Flow Meter Part Number onstruction PAS (") PAS1 (") (PAS) A) 2 inch B) 2-1/2 inch ) 3 inch D) 3-1/2 inch E) 4 inch F) 5 inch G) 6 inch H) 8 inch I) 10 inch J) 12 inch K) 14 inch Dimensions (inches) Probe Length A B AS 6.625 5.813 AS1 6.750 5.813 (PAS1) A) 12 inch B) 14 inch ) 16 inch D) 18 inch E) 20 inch F) 24 inch G) 30 inch H) 36 inch I) 42 inch J) 48 inch Pipe Orientation A) Horizontal B) Vertical Probe Material 1) 316/316L-SS 2) Monel 3) Inconel 4) Hastelloy X) Other (consult factory for information) A) Std G) 100 B) 20 H) 120 ) 30 I) 140 D) 40 J) 160 E) 60 K) XH F) 80 Probe Width AS.875 AS1 1.25 L) XXH M) 5S N) 10S O) 40S P) 80S A) 1/2" NPT B) 1/2" Socket ) TT3 (Integral 3 Valve D) TT5 (Integral 5 Valve E) Transmitter Flange onnection onnection A) S ompression Fitting w/ss Ferrule B) SS ompression Fitting w/ss Ferrule Instrument Valve* A) 1/2" Gate S w/cross B) 1/2" Gate SS w/cross *NOTE: Transmitter Flange onnection Options available when Option E under is selected. (consult factory for information) Pipe Mounting 1) A105 S 3000# 2) 316/316L SS 3000# 3) A105 S 3000# (see below) 4) 316/316L SS 3000# RTD (Use with Instrument onnection option E only) 1) 100 Ohm RTD 3 wire w/explosion Proof Head 2) 100 Ohm RTD 3 wire, Integral w/aluminum Head PIPE I.D. FLOW METERING EQUIPMENT B A 8635 Washington Avenue Racine, WI 53406-3738 USA Tel: (262) 639-6770 Fax: (262) 417-1148 Toll Free: (800) 632-7337 Maximum Allowable DP (Inches of Water olumn) (inches) 2 2-1/2 3 3-1/2 4 5 6 8 10 12 14 16 18 20 24 26 30 32 36 42 Single Support 880 525 396 283 197 153 126 114 100 87 53 240 175 147 113 90 74 68 50 34 Double Support 2380 1568 1283 1117 980 757 689 512 250 195 960 700 585 450 295 270 215 155 Preso and Ellipse are registered trademarks of Racine Federated Inc. Inconel is a registered trademark of Special Metals orporation Hastelloy is a registered trademark of Haynes International Form No. 4-25-01 AS Rev. 1/07 Printed in USA

F L O W M E T E R I N G E Q U I P M E N T Model ASF Ellipse Pitot Tube Annular Flow Meter Preso s patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement devices. This differential pressure flow meter is designed with a series of ports facing the upstream velocity pressures, as well as flow sensing ports strategically located ahead of the trailing edge flow separation. Features Patented elliptical design outperforms traditional devices Single point pipe entry for DP, temperature and static pressure No dampening software required Lowest pressure loss in industry (typically 3% of DP in a 12" line) due to its patented aerodynamic profile NIST traceable calibration: Optional independent labs Benefits Accuracy: ±0.75% of reading, repeatability: ±0.1% of reading Turndown ratio: 17:1; no vacuum effects No moving parts equals long, trouble-free service life True static pressure measurement rather than a calculated value Overcomes loss of accuracy caused by fluid separation at the sensor body The multi-ported, self averaging flow element consists of an elliptical shape with two independent flow sensing chambers. The impact velocity (high pressure) are located along the leading edge and the true static (low pressure) are on the exterior probe side. Model ASF comes with instrument shut-off valves with connections to accept a transmitter or direct indicating meter. ISO ERTIFIED 9001: 2000 True static Impact velocity 1-800-632-7337 Specifications Applications: Steam s: 2 to 48 inches (50 to 1220 mm) Pressure: Vary per flange ratings Temperature: Vary per flange ratings Accuracy: ± 0.75% of reading Turndown Ratio: 17:1 with no vacuum effect Standard omponents: Reynolds Number: Resonance: T-type head, 316 SS ½" FNPT connection S compression fitting with SS ferrule S 3000 lb. weld fitting ASTM A105 316/316L SS Ellipse sensor 316 SS ID tag with wire Greater than 75,000 maintains most accurate flow measurements Less than 75,000 consult factory for estimated results If greater than 0.8, use double support per ASME PT 19.3 www.preso.com

Model ASF Ellipse Pitot Tube Annular Flanged Flow Meter Part Number onstruction: PASF (") PASF1 (") PASF2 (2-1/4") (PASF) A) 2 inch B) 2-1/2 inch ) 3 inch D) 3-1/2 inch E) 4 inch F) 5 inch G) 6 inch H) 8 inch I) 10 inch J) 12 inch K) 14 inch (PASF1) (PASF2) A) 12 inch B) 14 inch ) 16 inch D) 18 inch E) 20 inch F) 24 inch G) 30 inch H) 36 inch I) 42 inch J) 48 inch *ASF2 probe design not pictured contact factory for more information Pipe Orientation A) Horizontal B) Vertical A) Std G) 100 B) 20 H) 120 ) 30 I) 140 D) 40 J) 160 E) 60 K) XH F) 80 PIPE I.D. L) XXH M) 5S N) 10S O) 40S P) 80S B A Probe Material 1) 316/316L-SS 2) Monel 3) Inconel 4) Hastelloy X) Other (consult factory for information) A) 1/2" NPT B) 1/2" Socket ) TT3 (Integral 3 Valve D) TT5 (Integral 5 Valve E) Transmitter Flange onnection Pipe Mounting 1) A105 S 3000# 2) 316/316L SS 3000# 3) A105 S 3000# (see below) 4) 316/316L SS 3000# Instrument Valve* A) 1/2" Gate S w/cross B) 1/2" Gate SS w/cross *NOTE: Transmitter Flange onnection Options available when Option E under is selected. (consult factory for information) onnection PASF0 PASF PASF1 PASF2 A) ¾" " RF Flange 150# S B) ¾" " RF Flange 300# S RTD ) ¾" " RF Flange 600# S 1) 100 Ohm RTD 3 wire Dimensions (inches) D) ¾" " RF Flange 900/1500# S w/explosion Proof Head E) ¾" " RF Flange 150# SS 2) 100 Ohm RTD 3 wire, Probe Length Probe Width G) ¾" " RF Flange 600# SS A B H) ¾" " RF Flange 900/1500# SS ASF 11.63 5.25 ASF.875 F) ¾" " RF Flange 300# SS Integral w/aluminum Head ASF1 11.63 5.25 ASF1 1.25 *ASF2 10.00 5.25 *ASF2 2.25 Maximum Allowable DP (Inches of Water olumn) (inches) 2 2-1/2 3 3-1/2 4 5 6 8 10 12 14 16 18 20 24 26 30 32 36 42 880 525 396 283 197 153 126 114 100 87 53 Single Support 240 175 147 113 90 74 68 50 34 2-1/4 779 660 610 495 410 346 218 187 136 105 85 2380 1568 1283 1117 980 757 689 512 250 195 Double Support 960 700 585 450 295 270 215 155 2-1/4 952 878 780 550 410 350 FLOW METERING EQUIPMENT Division of Racine Federated Inc. 8635 Washington Avenue Racine, WI 53406-3738 USA Tel: (262) 639-6770 Fax: (262) 417-1148 Toll Free: (800) 632-7337 Preso and Ellipse are registered trademarks of Racine Federated Inc. Inconel and Monel are registered trademarks of Special Metals orporation Hastelloy is a registered trademark of Haynes International Form No. 4-25-01 ASF Rev. 6/07 Printed in USA

F L O W M E T E R I N G E Q U I P M E N T Model AHL Ellipse Pitot Tube Annular High Pressure Hot Tap Flow Meter Preso s patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement devices. This differential pressure flow meter is designed with a series of ports facing the upstream velocity pressures, as well as flow sensing ports strategically located ahead of the trailing edge flow separation. Features Hot-tap model installs without system shutdown Single point pipe entry for DP, temperature and static pressure No dampening software required Lowest pressure loss in industry (typically 3% of DP in a 12" line) due to its patented aerodynamic profile Optional NIST traceable calibration Benefits Accuracy: ±0.75% of reading Repeatability: ±0.1% of reading Turndown Ratio: 17:1; no vacuum effects No moving parts equals long, trouble-free service life True static pressure measurement rather than a calculated value Overcomes loss of accuracy caused by fluid separation at the sensor body The multi-ported, self averaging flow element consists of an elliptical shape with two independent flow sensing chambers. The impact velocity (high pressure) are located along the leading edge and the true static (low pressure) are on the exterior probe side. Model AHL comes with instrument shut-off valves or optional integral manifold valve for direct transmitter mount. RAINE FEDERATED IN. ISO 9001 : 2000 FILE N0. A6856 True static Impact velocity 1-800-632-7337 Specifications Applications: Air, Liquids and Gases s: 2 to 30 inches (50 to 760 mm) Pressure: 800 PSI (5515 kpa) max. onsult factory for higher pressure Temperature: 800 F (426 ) max. onsult factory for higher temperature Accuracy: ± 0.75% of reading Turndown Ratio: 17:1 with no vacuum effect Standard omponents: Reynolds Number: Resonance: T-type head, 316 SS ¼" or ½" FNPT connection S 3000 lb. weld fitting ASTM A105 316/316L SS Ellipse sensor Instrument valves (2 per sensor) ¼" or ½", S 316 SS ID tag with wire 150 lb. 316/316L SS sensor flange S packing chamber with molythane or graphite packing gland S packing chamber flange, 150 lb. with SS cap 316-SS isolation ball valve, NPT threaded S threaded nuts and bolts S nipples, schedule 40 Greater than 75,000 maintains most accurate flow measurements Less than 75,000 consult factory for estimated results Less than 0.8 but greater then 1.2. If greater than 0.8, use double support. System shutdown is required when the double support option is used. Select larger diameter Ellipse to avoid double support. www.preso.com

Model AHL Ellipse Pitot Tube Annular High Pressure Hot Tap Flow Meter Part Number onstruction PAHL ( ") PAHL1 (1-¼") * (PAHL) A) 2 inch B) 2-½ inch ) 3 inch D) 3-½ inch E) 4 inch F) 5 inch G) 6 inch H) 8 inch I) 10 inch J) 12 inch K) 14 inch * (PAHL1) A) 12 inch B) 14 inch ) 16 inch D) 18 inch E) 20 inch F) 24 inch G) 30 inch A) Std B) 20 ) 30 D) 40 E) 60 F) 80 *For larger pipe sizes, see the AHF brochure. SH. STANDARD SH. STANDARD G) 100 H) 120 I) 140 J) 160 K) XH L) XXH M) 5S N) 10S O) 40S P) 80S AHL A Dimensions (inches) Size Inserted Retracted 2" 29-½" 38-½" 2-½" 30" 39-½" 30-½" 40-½" 3-½" 31" 41-½" 4" 31-½" 42-½" 5" 32-½" 44-½" 6" 33-⅜" 46-½" 8" 35-⅜" 50-½" 10" 37-⅜" 54-½" 12" 39-⅜" 58-½" 14" 41-⅜" 61-¾" AHL1 A Dimensions (inches) Size Inserted Retracted 12" 14" 16" 18" 20" 24" 30" 42-⅛" 44-⅛" 46-⅛" 48-⅛" 50-⅛" 54-⅛" 60-⅛" 61-¾" 65" 69" 7 77" 85" 97" AHL AHL1 Probe Width.875 1.25 Pipe Orientation A) Horizontal B) Vertical Probe Material 1) 316/316L-SS 2) Monel 3) Inconel 4) Hastelloy X) Other (consult factory to review application) A) ½" NPT B) ½" Socket ) TT3 (Integral 3 Valve D) TT5 (Integral 5 Valve E) Transmitter Flange onnection Insertion Mechanism/ Isolation Ball valve A) S cage nipple & rods B) SS cage nipple & rods ) S gear drive, cage nipple & rods D) SS gear drive, cage nipple & rods (Note: SS gear drive - SS for housing & wetted parts only) X) Other A PIPE I.D. Note: Probe with optional gear drive not pictured. ontact factory for more information. Pipe Mounting 1) A105 S 3000# 2) 316/316L SS 3000# 3) Supplied separately by Preso Packing Material 1) Molythane (-65 F to 200 F, 140 F in water and high water-based fluids) 2) Viton /Fluorocarbon (-20 F to 400 F) 3) Graphoil (1200 F) 4) EPDM (-65 F to 300 F, 400 F in steam) 5) Fluoromyte (-65 F to 300 F) X) Other Instrument Valve A) ½" Needle S B) ½" Needle SS ) ½" Gate S D) ½" Gate SS NOTE: Transmitter Flange onnection Options available when Option E under is selected. (consult factory for information) RTD 1) 100 Ohm RTD 3 wire w/ Explosion Proof Head 2) 100 Ohm RTD 3 wire, Integral w/aluminum Head Maximum Allowable DP (Inches of Water olumn) (inches) 2 2-½ 3 3-½ 4 5 6 8 10 12 14 16 18 20 24 26 30 NOTE: Ensure that DP falls within range noted on chart below. Double Supports are not recommended for Hot Tap/Wet Tap models. Single Support 880 525 396 283 197 153 126 114 100 87 53 1-¼ 240 175 147 113 90 74 68 50 34 Double Support * 2380 1568 1283 1117 980 757 689 512 250 195 1-¼ 960 700 585 450 295 270 215 155 FLOW METERING EQUIPMENT 8635 Washington Avenue Racine, WI 53406-3738 USA Tel: 262-639-6770 Fax: 262-417-1148 Toll Free: 800-632-7337 E-mail: info@preso.com PRESO and ELLIPSE are registered trademarks of Racine Federated Inc. INONEL and MONEL are registered trademarks of Special Metals orporation HASTELLOY is a registered trademark of Haynes International VITON is a registered trademark of DuPont Dow Elastomers Form No. 4-25-01 AHL Rev. 1/08 Printed in USA 2007 Racine Federated Inc., all rights reserved.

F L O W M E T E R I N G E Q U I P M E N T Model AHS Ellipse Pitot Tube Annular Threaded Hot Tap Steam Flow Meter Preso s patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement devices. This differential pressure flow meter is designed with a series of ports facing the upstream velocity pressures, as well as flow sensing ports strategically located ahead of the trailing edge flow separation. Features Hot-tap model installs without system shutdown Single point pipe entry for DP, temperature and static pressure No dampening software required Lowest pressure loss in industry (typically 3% of DP in a 12" line) due to its patented aerodynamic profile Optional NIST traceable calibration Benefits Accuracy: ±0.75% of reading Repeatability: ±0.1% of reading Turndown Ratio: 17:1; no vacuum effects No moving parts equals long, trouble-free service life True static pressure measurement rather than a calculated value Overcomes loss of accuracy caused by fluid separation at the sensor body The multi-ported, self averaging flow element consists of an elliptical shape with two independent flow sensing chambers. The impact velocity (high pressure) re) are located along the leading edgee and the true static (low pressure) are on the exterior er probe side. Model AHS comes with instrument shut-off valves or optional integral manifold valve ve for direct transmitter mount. RAINE FEDERATED IN. ISO 9001 : 2000 FILE N0. A6856 True static Impact velocity 1-800-632-7337 Specifications Applications: Saturated and super heated steam s: 2 to 24 inches (50 to 610 mm) Pressure: 800 PSI (5515 kpa) max. onsult factory for higher pressure Temperature: 800 F (426 ) max. onsult factory for higher temperature Accuracy: ± 0.75% of reading Turndown Ratio: 17:1 with no vacuum effect Standard omponents: Reynolds Number: Resonance: T-type head, 316 SS ¼" or ½" FNPT connection S 3000 lb. weld fitting ASTM A105 316/316L SS Ellipse sensor Instrument valves (2 per sensor) ¼" or ½", S 316 SS ID tag with wire 150 lb. 316/316L SS sensor flange S packing chamber with molythane or graphite packing gland S packing chamber flange, 150 lb. with SS cap 316-SS isolation ball valve, NPT threaded S threaded nuts and bolts S nipples, schedule 40 Greater than 75,000 maintains most accurate flow measurements Less than 75,000 consult factory for estimated results Less than 0.8 but greater then 1.2. If greater than 0.8, use double support. System shutdown is required when the double support option is used. Select larger diameter Ellipse to avoid double support. www.preso.com

Model AHS Ellipse Pitot Tube Annular Threaded Hot Tap Steam Flow Meter Part Number onstruction PAHS ( ") PAHS1 (1-¼") (PAHS) A) 2 inch B) 2-½ inch ) 3 inch D) 3-½ inch E) 4 inch F) 5 inch G) 6 inch H) 8 inch I) 10 inch J) 12 inch K) 14 inch (PAHS1) A) 14 inch B) 16 inch ) 18 inch D) 20 inch E) 24 inch A) Std B) 20 ) 30 D) 40 E) 60 F) 80 G) 100 H) 120 I) 140 J) 160 K) XH Pipe Orientation A) Horizontal B) Vertical Probe Material 1) 316/316L-SS 2) Monel 3) Inconel 4) Hastelloy X) Other (consult factory to review application) L) XXH M) 5S N) 10S O) 40S P) 80S *For larger pipe sizes, see the AHZ brochure. SH. STANDARD SH. STANDARD AHS A Dimensions (inches) Size Inserted Retracted 2" 2-½" 3-½" 4" 5" 6" 8" 10" 12" 14" 24-⅝ 25 25-½ 26 26-½ 27-½ 28-⅜ 30-⅜ 32-⅜ 34-⅜ 36-⅜ 34" 35" 36" 37" 38" 40" 42" 46" 50" 54" 57" AHS1 A Dimensions (inches) Size Inserted Retracted 12" 14" 16" 18" 20" 24" 38-½" 40-½" 42-½" 44-½" 46-½" 50-½" 58-¾" 62" 66" 70" 74" 82" AHL AHL1 Probe Width.875 1.25 A) ½" NPT B) ½" Socket ) TT3 (Integral 3 Valve D) TT5 (Integral 5 Valve E) Transmitter Flange onnection Insertion Mechanism/ Isolation Ball valve A) S cage nipple & rods B) SS cage nipple & rods ) S gear drive, cage nipple & rods D) SS gear drive, cage nipple & rods (Note: SS gear drive - SS for housing & wetted parts only) X) Other Note: Probe with optional gear drive not pictured. ontact factory for more information B A PIPE I.D. Pipe Mounting 1) A105 S 3000# 2) 316/316L SS 3000# 3) Supplied separately by Preso Packing Material 1) EPDM (-65 F to 300 F, 400 F in steam) 2) Viton /Fluorocarbon (-20 F to 400 F) 3) Graphoil (1200 F) 4) Fluoromyte (-65 F to 300 F) X) Other Instrument Valve A) ½" Gate S with cross B) ½" Gate SS with cross NOTE: Transmitter Flange onnection Options available when Option E under is selected. (consult factory for information) RTD 1) 100 Ohm RTD 3 wire w/ Explosion Proof Head 2) 100 Ohm RTD 3 wire, Integral w/aluminum Head Maximum Allowable DP (Inches of Water olumn) (inches) 2 2-½ 3 3-½ 4 5 6 8 10 12 14 16 18 20 24 NOTE: Ensure that DP falls within range noted on chart below. Double Supports are not recommended for Hot Tap/Wet Tap models. Single Support 880 525 396 283 197 153 126 114 100 87 53 1-¼ 240 175 147 113 90 74 68 Double Support 2380 1568 1283 1117 980 757 689 512 250 195 1-¼ 960 700 585 450 295 270 FLOW METERING EQUIPMENT 8635 Washington Avenue Racine, WI 53406-3738 USA Tel: 262-639-6770 Fax: 262-417-1148 Toll Free: 800-632-7337 E-mail: info@preso.com PRESO and ELLIPSE are registered trademarks of Racine Federated Inc. INONEL and MONEL are registered trademarks of Special Metals orporation HASTELLOY is a registered trademark of Haynes International VITON is a registered trademark of DuPont Dow Elastomers Form No. 4-25-01 AHS Rev. 1/08 Printed in USA 2007 Racine Federated Inc., all rights reserved.