BEST COST EFFECTIVE FLOW MESUREMENT EVEN FOR LRGE SIZE LINES O-0 Series GLSS TUBE TYPE ORIFLOMETER GENERL O-0 series ORIFLO METER is a flow meter consisting of a orifice plate and a GLSS TUBE type variable area flow meter. Since the flow rate is measured with a small sized flow meter set to a bypass piping, the flow measurement even for large sized lines can be economically conducted. In addition to the local indication type, alarm contact version is also available. STNDRD SPECIFICTION Detection type : Bypass orifice type Measuring fluid : Liquids (Viscosity : up to 3mPa s) and Gases (Not suitable for slurry and steam) vailable tapping and sizes : ) D D/ taps (O- - P) 0mm to 500mm ) Corner taps (with orifice ring) (O- - C) 50mm to 500mm 3) Flange taps (O- - F) 50mm to 500mm 4) Vena contracta taps (O- - V) 00mm to 500mm Note : 550mm or more can be supplied on request. Process connection : JIS5K/K/0K, NSI/JPI CLSS 50/300 and Others. Temperature of liquid : Max. 0 C *: It is general data, and the maximum temperature may change by terms of use and environment. llowable thermal shock : 0 C Fluid pressure : Max..0MPa Indication accuracy : 3% F.S. Paint color : Munsell.5BG4/.5 (Body made of SUS not painted) Function : O- - Local indication only O-5 - Local indication with alarm contact : Refer to MTERIL ND SCOPE OF SUPPLY for details. MODEL CODE Function Model code O- 5 Flow direction of main pipe Description Local indication only Local indication with alarm contact Bottom to top Left to right Right to left Top to bottom Standard DP/Scale range Range ability (standard) : Standard Float material Stainless steel luminum PTFE PVC Standard DP (kpa) Liquids 30 5 5 Gases Custom-made meter available for more than the above DP. In case of custom-made meter, effective scale range is to be different. Refer to the maximum flow range by size, or contact us. Position of indicator Type of tapping B P C F V bove main pipie Below main pipie D D/ Taps Flange taps Corner taps (With orifice ring) Vena contracta taps : vailable sizes for types of tapping is to be referred to STNDRD SPECIFICTIONS. : Orifice rings are included in scope of supply as standard. TG-F05-4E TG-F05-E NOV. 00K MY. 04K
O-0 Series ORIFLOMETER CPCITY OF ECH LINE SIZE FOR LIQUID PPLICTIONS S FOR GS PPLICTIONS The maximum flow rate of flowmeter can be specified in the above mentioned POSSIBLE SCLE RNGE. NOTE : bove table are based on the fact that the material of main pipe is SGP (Carbon steel pipes for ordinary pipes JIS G 345). The maximum flow rate of the main pipes other than SGP are determined by multiplying above figures by the value equal to (actual inside diameter/sgp inside diameter) to above figures. : bove table is applicable for measurement of Water (Density.0g/cm 3, Viscosity.0mPa s). When measuring liquid whose density is not.0g/cm 3, refer to the above table after calculating flow rate converted to air by the following formula. ( )/( ) Flow rate converted to water Density of float Flow rate of actual fluid Density of actual fluid Density of float 3. irflow indicates the maximum measurable flow range based on 0, atm. When operating conditions are different, refer to the above table after calculating flow rate converted to air by the following formula. Flow rate converted to air Flow rate of actual fluid Density conversion factor Gaseous density Temperature conversion factor Temperature for actual fluid Pressure conversion factor Pressure for actual fluid TOKYO KEISO CO., LTD. TG-F05-E
O-0 Series ORIFLOMETER FLOW DIRECTION ND BYPSS PIPING bove drawings show the case of corner tapping. The same piping configurations are applied also for other types of tappings. TG-F05-E TOKYO KEISO CO., LTD. 3
O-0 Series ORIFLOMETER STNDRD SIZES OF BYPSS PIPING (In case of Flange rating JISK) () Corner taps (With orifice ring) Horizontal piping L (L ) () D D/ Taps Horizontal piping L t L () (L4) (50) (00) detail drawing Rc / φ L3 (30) Vertical piping (Bottom to top) (L ) (0) Vertical piping (Bottom to top) (L 4) () L L (0) t L L3 (00) 0 Main pipe size L L 50mm 5mm 0mm 0mm 5mm 50mm 00mm 50mm 300mm 350mm 400mm 450mm 500mm 5 35 40 50 5 0 05 45 5 0 35 355 The dimensions L include gasket thickness: t.5mm x pcs for 50mm, 5mm, 0mm and t3mm x pcs for 0mm or larger. SUGGESTIONS FOR INSTLLTION 30 unit : mm. Upper/lower straight tube length. Since the pressure loss within the bypass pipe is precalculated, do a specified bypass piping in accordance with the related approval drawing. 3. If you need bypass pipes of which sizes are different from those of standard ones due to a piping design in your factory, please contact us. Main pipe size L L t L3 L4 50mm 5mm 0mm 0mm 5mm 50mm 00mm 50mm 300mm 350mm 400mm 450mm 500mm 5 0 5 30 33 3 43 4 4 5 5 44 3 5 33 30 3 45 5 5 3 30 50 0 30 50 0 3 350 L includes thickness of gaskets. t3 x pcs unit : mm L and L are for SGP piping. For other piping material; L=D 3, L=/D (t3) where D=Pipe inside dimeter The straight run of pipe varies, depending on the piping condition and the contraction ratio of diameter, and the following is just the outline. [Reference] Straight run of pipe (Upstream) Straight run of pipe (Downstream) Elbow Tees D 4D Valve (Gate valve fully opened) D 4D D stands for the inside diameter of pipe Straight run of pipe means the length from the upstream face of orifice plate. 4 TOKYO KEISO CO., LTD. TG-F05-E
O-0 Series ORIFLOMETER MTERIL ND SCOPE OF SUPPLY 4 5 3 4 3 4 3 <Corner taps> <D D/ Taps and vena contracta taps> <Flange taps> No. Parts name Orifice flange Flange gasket Main orifice Orifice ring Ball valve Bypass piping Bypass orifice Gasket Indicator Costomer's supply Costomer's supply (Optionally available) Costomer's supply (Optionally available) For Liguids : Non sbestos, For Gas : NBR or FPM * Gaskets between Main pipe orifice (or Orifice ring) and piping flanges as well as bolts and nuts for installation are customer's scope of supply unless otherwise specified. ORDERING INFORMTION Model Fluid name Density Viscosity Pressure Temperature Measuring range class Main pipe Size For O-5 - (larm version) O- - O-5 - Class Class Class 3 Special ( ) mm SGP STPG,STPT Stainless Steel Pipe sch No. Lining Pipe (ID mm) sch No. Others (OD mm, ID mm) PVC ( VP VU) STPY (t mm) Process connection Type of alarm High Low Setting point Cautions on the use of glass tube variable area flowmeters CUTION void the use of glass tube variable area flowmeters for the following services.. Liquid services subject to impulse pressure in the process.. Secondary accidents might occur due to the breakage of glass in such services : Toxic fluids such as poisons, stimulant and narcotics Flammable fluids Explosive fluids 3. Gas handling process where breakage of glass might result in gas leakage or scattering of glass fragments. 4. The installation places of the flowmeters where breakage of glass might be caused by the accidents from the surrounding piping or equipment. 5. On-off operation where breakage of glass might be caused by the collision of the float inside meter due to the abrupt change of flow.. Services where the heat shock by abrupt change of temperature is expected. * Specification is subject to change without notice. Head Office : Shiba Toho Building, 4 Shibakoen, Minato-ku, Tokyo 5 55 Tel : +-3 343 5 (KEY) ; Fax : +-3 3433 4 e-mail : overseas.sales@tokyokeiso.co.jp ; URL : http://www.tokyokeiso.co.jp TG-F05-E TOKYO KEISO CO., LTD. 5