Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE #

Similar documents
Controllers & Transmitters

POWERS CONTROL RC 195 Multiple Input Receiver- Controller

Powers Controls TT 184 Temperature Transmitters

TK-6024, TK-6124, TK-8024, TK-8124

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

Pneumatic Controls. Pneumatic Controls Sections

Distributed By: M&M Control Service, Inc Product Product Code Technical Instructions Page #

Auxiliary Equipment. Table of Contents. Auxiliary Equipment H-1. Product Product Code Technical Instructions Page #

Powers TM Controls RL 243 SW Switching Relay

VAV Terminal Unit Control Package

N-1001 Economizer Logic Network

2211 Series. Application. Features. One-Pipe Pneumatic Room Thermostats General Instructions SPECIFICATIONS

POWERS TM CONTROLS SW 786 Selector Switch

T PI Receiver-Controller

Temperature Indicating Controller

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions

Powers TM Controls SW 141 Differential Static Airflow Switches

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

OM Field-Type I/P Converter Model : KUX113 User's Manual

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

Self-Operating Temperature Regulators

POWERS TM CONTROLS LC Pneumatic Damper Actuator

TKS-5001, TKS , TKS-6001, TKS-7001

Air Flow Measurement Technologies

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Terms. Direct Acting (DA) The action of a controller that increases its branch line pressure as the controlled variable increases

SECTION METERS AND GAUGES FOR HVAC PIPING

SECTION AIR TERMINAL UNITS

RDN4 - RDN8 Differential pressure switch

RPPN6 - RPPN8 Industrial pressure switch with high overpressure resistance

Fisher 2506 and 2516 Receiver Controllers

Flowrite AP 599 Series

P445 Series Electronic Lube Oil Control

Powers Controls RL 147 Positioning Relay

P70, P72, and P170 Controls for Low Pressure Applications

2 - Air flow measuring sensors FloXact -Stick

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions

P70, P72 and P170 Series Controls for High Pressure Applications

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Damper Actuator Installation

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

RPPN3 - RPPN7 Industrial pressure switch

System 350 P352AB Electronic Pressure Control Series

Model 40 Temperature Bulbs And Connections

SECTION INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Digital ph transmitter

Paddle-wheel flow controller for On/Off control

TS Series TS Series

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

Installation and Operation Instructions DLP Series

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University:

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Low Pressure Sensor. Overview. Specifications. Installation and Operation

P70, P72, and P170 Series Controls for High Pressure Applications

Signet Pressure Transmitter

Measuring probe For ventilation and air-conditioning Model A2G-FM

GE Sensing & Inspection Technologies

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

Replacement Parts List

Creative Engineers Inc. Pittsburgh, PA York, PA Phoenix, MD P.O. Box 206 Phoenix, MD Phone (443)

Surface-mounting Thermostats Series ATH-SW

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

SAMPLE PRODUCT SPECIFICATIONS

General Information... 2

Laboratory Exhaust Air Terminal

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

PRO REMOTE Series CAPACITANCE PROBE

V-9502 Series Pneumatic Valve Actuator Positioners

Differential Pressure Transmitter

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

Dial thermometers. Gas filled system and Bi-metal. dial thermometers

BAS Construction Checklist

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Pressure Transmitter

Remote Temperature Controllers. Quick Selection Guide

ONE METER FOR: AIR, WATER, HUMIDITY, POWER & CO2

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Type 289RC Exhaust Booster

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

RETROFIT TERMINAL UNITS

ABB Automation. Variable Area Dial Flow Indicator Series 10A2227. Series 10A2227 Variable Area Dial Flow Indicator

C7170A,B Encapsulated Temperature Sensor

KEL DIFFERENTIAL PRESSURE FLOWMETERS

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

Laboratory Exhaust Air Terminal

A419ABG-3C Electronic Temperature Control

SP/SF Series Flow Switches

Compact Low Pressure Sensor

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

Paddle-wheel flow controller for On/Off control

Creative Engineers Inc. Pittsburgh, PA York, PA Phoenix, MD P.O. Box 206 Phoenix, MD Phone (443)

EP-8000 Series Electro-Pneumatic Transducers

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Laboratory Room Single Duct Supply Air Terminal

Transcription:

PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE # Pneumatic Receiver-Controllers Single Input Receiver-Controller RC 195 155-119P25 C-3 Multiple Input Receiver-Controller RC 195 155-036P25 C-5 Pneumatic Transmitters Temperature Transmitters TT 184 155-077P25 C-7 Room and Duct Humidity Transmitters HT 186 155-026P25 C-9 Low Differential Pressure Transmitters PT 141 155-035P25 C-11 Pneumatic Receiver Gauges Receiver Gauges GA 142A 155-023P25 C-15 Pneumatic Regulators/Controllers Static Pressure and Liquid Level Regulators PR 269 155-033P25 C-17 Accessories and Service Kits C-19

easily replaces: Honeywell Robertshaw Seibe produces a pneumatic output signal based on the net pneumatic input and the mechanical settings of the setpoint and percent proportional band. This controller transmitter ranges temperatures, humidity, and pressure of mechanical equipment in commercial and industrial facilities. Typical Connections

Action Input #1... Direct Input #2... Pneumatic Inputs... Control Output... Operating Ambient Temperature Range... Supply Pressure Operating... Maximum Safe... % Proportional Band Adjustment Range... Air Consumption... control pressure change not including transmitters Air Capacity... Supply... Exhaust... Mounting... Surface Air Connections Case Material... Dimensions... Shipping Weight... Description Part No. 195-0011 Manufacturer Manufacturer Part No. Part No. 1 RKS-1001 195-1000 RKS-2001 195-1000 RKS-5001 195-1000 Honeywell 195-1000 Honeywell 195-1000 T-5800-1 195-1000 Ordering Note 1. Includes 195-0011 Accessories & Service Kits

easily replaces: Honeywell Robertshaw Seibe produces a pneumatic output signal based on the net pneumatic input and the setpoint, percent proportional transmitter ranges used when the setpoint needs to be automatically reset Example: based on outside air temperature. Typical Connections

Action Input #1... Direct Input #2... Reset Input #3... Pneumatic Inputs... Control Output... Operating Ambient Temperature Range... Description Part No. 195-0003 Supply Pressure Operating... Maximum Safe... % Proportional Band Adjustment Range... control pressure change % Authority Adjustment Range... 20 to 200% Air Consumption... Air Capacity... Supply... Exhaust... Mounting... Air Connections Case Material... Dimensions... not including transmitters - Shipping Weight... Manufacturer Manufacturer Part No. Part No. 1 RKS-3002 195-2000 RKS-4002 195-2000 T-5800-3 195-2000 Robertshaw P-341 195-2000 Robertshaw P-541 195-2000 Honeywell RP908B 195-2000 Honeywell RP920B 195-2000 Ordering Note 1. Includes 195-0003 Accessories & Service Kits Humidity Control Temperature Control Static Pressure Control

easily replaces: Honeywell Robertshaw Seibe 184-0340 Room 184-0005 Temperature 184 Temperature 184 Temperature Temperature Transmitter with Transmitter with Transmitter with Transmitter. Remote The 184 Temperature Transmitters are direct acting, one-pipe instruments that sense temperature and transmit The 184 Temperature Transmitters can be used for a controller. Temperature Transmitters operate on the force-balance principle, using internal feedback for excellent linearity and accuracy. model. Refer to the appropriate product to locate the Retroline replacement. full range temperature ranges room transmitter Application Drawing Hot water temperature setpoint reset.

Action... Direct Output Air Pressure... Ambient Temperature Range... Input (supply) Air Pressure Restrictor Size...... Maximum... Thermal System Room...Bimetal Rigid Bulb...Rod and tube Remote Bulb... Air Consumption... Air Connections... Mounting Room... Rigid Bulb... Remote Bulb...... Cover Finish Room...Desert Beige, plastic... Dimensions Room...... Shipping Weights Room... Rigid Bulb... Remote Bulb......... Manufacturer Part No. Description Temperature Range Part No. Honeywell Rigid Bulb Transmitter 184-0120 Rigid Bulb Transmitter 184-0121 Room Temperature Transmitter 184-0126 T5002-201 Room Temperature Transmitter 184-0127 Johnson Controls Remote Bulb Transmitter T5210-1002 184-0123 Remote Bulb Transmitter T5210-1004 184-0122 Averaging Bulb Transmitter T5210-1007 184-0129 Averaging Bulb Transmitter T5210-1009 184-0125 Remote Bulb Transmitter T5210-1113 184-0124 Robertshaw 2220-053 Room Temperature Transmitter 184-0128 Accessories & Service Kits

186-0043 Room Humidity Transmitter. 186-0089 Duct Humidity Transmitter. The 186 Room and Duct Transmitters are one-pipe, direct acting pneumatic instruments that sense space humidity The 186 Room and Duct Humidity Transmitters operate on a force-balance principle with internal feedback to obtain response to humidity changes minimizes temperature effects and duct mounting that is at least for control of an air conditioning or process control system Room: the transmitter should be located where it senses actual room conditions Duct: in the return air duct. Application Drawing Typical Application of Return Air Duct

Action... Direct RH Range... 20 to 80% RH Maximum Operating Temperature... Supply Pressure Maximum...... Effect of 10 F (5.6 C) Temperature Change...Shift of 1% RH Air Consumption... Output Pressure... Air Connections... Mounting Room... Duct... Standard Room Cover Finish...Desert Beige, plastic Duct Box Material... Air Connections... Dimensions Room... Duct... Shipping Weights Room... Duct... Description Part No. Duct Humidity Transmitter 186-0089 Room Humidity Transmitter 186-0043

differential pressure input into a proportional air signal. the force-balance principal and can be used to indicate duct work. The output signal can be sent to a remotely pressure applications. Application Drawing Typical Application of Duct Static Pressure Control

Action... Direct Input (Supply) Air Pressure... Maximum... Overpressure in HI and LO Ports... Output Pressure 1... Air Consumption... Operating Ambient Temperature Minimum... Maximum... for more details. Calibration... Accuracy... ±5% full scale Mid Range... ±2% full scale Air Connections...... Maximum Sensing Line Length...... Materials... Mounting...Horizontal only Dimensions... Shipping Weight... Differential Input Pressure Part No. 141-0590 141-0591 141-0592 141-0593 Control Symbol Description Part No. DPT1 141-0593 DPT2 141-0592 SPS 269-062 195-0003 142-0266 M1 as req. R1 243-0009 Accessories & Service Kits

Typical Static Pressure Differential Control Typical Differential Velocity Pressure Control Typical Static Pressure Control Example: Typical Velocity Pressure 1 Indication mended for these conditions. Standard Pitot Tube - head for standard air.

required to report system or functional operating status, polyethylene tubing. and respond to pneumatic signals from a remotely located transmitter used to measure temperatures, humidity, and pressures of mechanical equipment. Application Drawing

Standard Operating Pressure... Maximum Operating Pressure... Accuracy... 2-1/2% of full scale middle half of scale 3-1/2% elsewhere Air Connections...... OD polyethylene tubing Dimensions......... Shipping Weights......... For pressure gauges, refer to the Auxiliary Equipment, Section H-7. English Units Control Range Part No. 1-1/2" 2-1/2" 3-1/2" 142-0238 142-0258 142-0285 142-0430 142-0436 142-0442 142-0259 142-0240 142-0260 142-0287 142-0316 142-0327 142-0264 142-0290 142-0434 142-0440 142-0241 142-0261 142-0288 142-0431 142-0437 142-0443 142-0242 142-0262 142-0284 142-0432 142-0438 142-0444 142-0243 142-0263 142-0289 20 to 80% RH 142-0245 142-0265 142-0283 0 to 50 psi 142-0435 142-0441 142-0447 3 to 15 psi 142-0293 142-0295 20 142-0396 20 142-0246 142-0266 142-0291 20 142-0394 20 142-0247 142-0267 142-0292 142-0229

is a direct acting, pneumatic differential controller that measures static or head pressure, and is used to directly of pressures 269 Static Pressure Regulator The 269 Static Pressure Regulator can be used to control 269 Liquid Level Regulator Application Drawings Typical Application of Liquid Level Regulation Typical Application of Static Pressure

Control Action... Direct Supply Pressure... Maximum... Maximum Ambient Temperature... Maximum Allowable Pressure... Number of Turns for Setpoint Change of 1" W.G. 269-1066...approx. 6 turns 269-1067... approx. 1/2 turn 269-1068... approx. 6 turns 269-1069... approx. 1/4 turn Response 269-1066, 269-1067, 269-1068... 269-1069... Air Connections... Dimensions... Shipping Weight... Differential Range Sensitivity (Fixed) Mounting Position Part No. Ordering Note 1 40 scim restrictor 40 scim restrictor 80 scim restrictor 40 scim restrictor Upright Upside Down Upright Upside Down Upright Upside Down Upright Upside Down 269-1066 269-1067 269-1068 269-1069

PRODUCT PAGE # Direct Mount Controller Immersion Well C-20 Pneumatic Controllers Pneumatic Spring Clamp C-20 185/195 Receiver-Controllers Simulator C-20 Tools C-21 Replacement Scales C-21 Connectors/Restrictors C-21 Termination Strips C-21 Replacement Parts C-21 184 Temperature Transmitters Restrictors C-22 Wells/Well Mounting Kit C-22 Bulb Shields C-22 Replacement Parts C-22 141 Air Velocity Transmitters Restrictors C-23 Probes C23

Direct Mount Controller Immersion Well. 1/2" NPT x 6" long Description Product Group Quantity Part No. Direct Mount Controllers 1 ARG150U All Pneumatic Products Pneumatic Spring Clamp. All 1 531-833 185/195 Receiver-Controllers 195-098 185/195 Receiver-Controller Simulator. Used for setup and calibration. Comes complete with a carrying case and the following parts: One gauge/switch assembly 185, 195 1 195-098 Two gauge/switch assemblies 185, 195 1 195-099 Three gauge/switch assemblies 185, 195 1 195-100 Receiver-Controller Calibration Slide Rule. Used to calculate proportional band and control point authority. Calibration Card. Shows transmitter pressures for various analog ranges to assist in calibration. 185, 195 1 153-054 185, 195 1 144-022

185/195 Receiver-Controllers Ordering Notes to Part No. Metric units. Description Product Group Quantity Part No. Setpoint Dial Sheets. Direct Acting and Reverse Acting. 195 4 Sheets 195-130 English Units Metric Units Scale ID -40 to +120 F -40 to +50 C A 50 to 100 F 10 to 38 C B 80 to 240 F 26 to 117 C C 20 to 80% RH -18 to +38 C D 0 to 100 F 1 to 58 C E 35 to 135 F 0 to 750 Pa F 0 to 3 W.G. 0 to 3.75 kpa G 0 to 15 W.G. 20 to 80% RH H 0 to 0.5 W.G. 0 to 125 Pa J Blank 10 divisions Blank 9 divisions K (DA) Blank 16 divisions Blank 11 divisions K (RA) -0.05 to ±0.2" W.G. -12.5 to +50 Pa L -0.5 to +0.5" W.G. -125 to +125 Pa M 0 to 10" W.G. 0 to 2.5 kpa N Blank 20 divisions Blank 15 divisions P 0 to 50 psi 0 to 345 kpa R 50 to 150 F 10 to 66 C S 40 to 240 F 4 to 116 C T -40 to +160 F -40 to +71 C V 30 to 190 F -1 to +88 C W Receiver-Controller Restriction Kit. Includes three input restriction plates, one pilot relay restriction plate, gaskets, and two screws. Receiver-Controller Connector Kit. Includes two plug-in connector assemblies, one 3-barb input connector assembly. 195 1 Kit 195-066 Multiple-Input 195 1 Kit 195-067 Termination Strip. For numbered ports 1 through 10, straight through connections for 1/4" (6 mm) OD polyethylene tubing. Pressure Gauge. Dual Scale 0 to 30 psig (0 to 200 kpa ) 12" NPT male thread (back) 195 1 195-082 184, 195 1 142-0373 In-Line Air Filter. 195 1 908-033

184 Temperature Transmitters Rigid Bulb Transmitter. Bulb 1/4" Dia. x 9" L (6 mm Dia. x 229 mm L) Description Temperature Range Part No. Remote Averaging Bulb Transmitter. 3/32" Dia. x 20' L (2 mm Dia. x 6.1 m L) with 12" (305 mm) Capillary 35 to 135 F (2 to 57 C) 184-0001 50 to 100 F (10 to 38 C) 184-0002 80 to 240 F (27 to 116 C) 184-0003 0 to 100 F (-18 to +38 C) 184-0028 35 to 135 F (2 to 57 C) 184-0004 0 to 100 F (-18 to +38 C) 184-0048 Remote Bulb Transmitter. 1/4" Dia. x 4" L (6 mm Dia. x 102 mm L) 3' (0.92 m) Capillary -40 to +120 F (-40 to +49 C) 184-0005 50 to 100 F (10 to 38 C) 184-0018 80 to 240 F (27 to 116 C) 184-0014 0 to 100 F (-18 to +38 C) 184-0036 -10 to +65 F (-23 to +18 C) 184-0015 35 to 135 F (2 to 57 C) 184-0034 30 to 190 F (-1 to +88 C) 184-0041 Description Product Group Quantity Part No. Remote Bulb Transmitter. 1/4" Dia. x 4" L (6 mm Dia. x 102 mm L) 3' (0.92 m) Armored Capillary Room Transmitter. With cover and wall plate (180-443) Restrictor Tees. 40 scim for 1/4" (6 mm) OD plastic. Required for 195 Receiver-Controller only when total transmitter line is greater than 300' (91 m) long. In-line Restrictors. 40 scim (11 ml/s) 184 1 184-0006 184 1 184-0340 184 Package of 5 184-114 184 Package of 5 184-117 Well Mounting Bracket Kit. 184 1 184-105 Copper Well. 1/4" D x 4" L (6 mm D x 102 mm L) 184 1 184-119 Stainless Steel Well. 1/4" D x 4" L (6 mm D x 102 mm L) 184 1 184-118 Outdoor Bulb Shield. 9" (229 mm) L 184 1 134-084

141 Air Velocity Transmitters Description Product Group Quantity Part No. Restrictor Tees. 40 scim for 1/4" (6 mm) OD plastic. Required for 195 Receiver-Controller only when total transmitter line is greater than 300' (91 m) long. 141 Package of 5 184-114 Static Pressure Sensor Probe. 141 1 269-062 Static Pressure Probe Kit. SW269 1 189-142