The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters.

Similar documents
FHF Floor Heating Manifold

SSM Floor Heating Manifold

High capacity valve body, type RA-G

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

High Capacity Valve Body, Type RA-G

Premounted Midi Shunts

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Premounted Midi Shunts

AV 23 Balancing valves SETTER Inline

Floor heating system, heating circuit with FHV-A in flow.

Manual presetting valves LENO MSV-BD

CHOOSING YOUR MANIFOLD & LOCATION

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Manual Presetting Valves LENO MSV-B

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Art.918C Pre-assembled manifold with flow meters, air

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

Pressure independent balancing and control valve

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Flow-compensated temperature controller AVTQ DN 15

dynacon floor heating manifold with automatic flow control

MrPEX 1 ½ " Brass Manifold Installation Guide

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

How to Choose the Right Manifold for Your Project Brass vs. Copper

TDU.3 floor distribution unit SK

Pressure independent balancing and control valve AB-QM DN

X-tra Collection for designer radiators and bathroom towel rails

HEATING SYSTEMS PRICE LIST 07 / 2008 TABLE OF CONTENTS

Ballorex Venturi 3.1 Introduction

Floor heating manifold with automatic flow control

FCU Floor Control Unit

X-tra Collection for designer radiators and bathroom towel rails

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

Pressure independent balancing and control valve AB-QM DN

MrPEX 1 ¼ Stainless Steel Manifold Installation Guide

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Automatic balancing valves ASV-PV DN (3rd gen.)

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

CT3202.0_01 EN February 2018

FHV control valves are flexible to use, easily installed and are available in two versions:

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

TA-6-way valve. Standard control valves 6-way valve for change-over systems

3 & 4-Way Rotary Valves

Thermostatically operated cooling water valves Type AVTA

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

K35 HeatBloC with 3-temperature mixing valve

Flow controller (PN 25) AVQ - return and flow mounting

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

VALVE FEATURES AVAILABLE MODELS LIMITS OF USE IP 67

Valve bodies type RA-N with integrated presetting

Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems

Flow controller (PN 25) AVQ - return and flow mounting

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

Manifold Isolation Valves

Instruction Manual For MrPEX Composite Radiant Manifold

Solenoid valve Types EVR 2 EVR 40 NC/NO

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5

TempControl Thermostatic Water Controllers

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

CALEFFI. QuickSetter Balancing Valve with flow meter. Installation Tip

MANIFOLDS AND DISTRIBUTION EQUIPMENT

Description. Ballorex Venturi. Versions. Benefits. Robinets manuels Balancing

Technical information Thermostatic radiator valves

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

Fan-coil valves Series

Product range Solex Technical data and dimensioning. 5 Years

2-position electric actuators with Ball valves VBZ ½...11/4

Your Personal Catalog Temperature Controllers All our know-how - is now yours

GTFLOW MANIFOLD FEATURES: BENEFITS:

For assistance call T&M. Tubing and manifolds. installation guide

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

2-Port and 3-Port Zone Valves PN 16

WAY MOTORISED COMPACT ZONE VALVES

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

Electric Flanged PN16 Cast Iron Ball Valve

Pre-assembled distribution manifolds for radiant panel systems

PRECISION UK Ltd. Medical Gas Outlet BS Standard

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

Valves, controls + systems Stations for the connection heat generator/heating circuit

Roth NP Manifold System Installation Instructions

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

AB-QM Pressure Independent Control Valve

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic radiator valves with presetting

Product Information. Brass Manifolds. Version A

T2 Wall Hung Radiator & UFH Manifolds

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Transcription:

Floor Heating Manifold FHF Application The Manifold FHF is used for controlling water flow in under floor heating systems. Each tube of the floor heating system is connected to the manifold, thus making it possible to control water flow or heat supply to each room in the building individually. The manifold consists of a supply and return manifold. The supply manifold includes possibility for individual shut-off of each circuit and as an option also flowmeter. The return manifold is equipped with integrated Danfoss pre-setting valves securing optimal hydraulic balance in the system. The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters. Manifold with flowmeter The manifold is supplied in modules of up to 12 outlets. In addition extension pieces are available for connecting the manifolds in series. Ball valves are available as an option for positive shut-off between manifold and system. The end pieces FHF-EM and FHF-EA are supplied with manual airvent or alternatively with automatic airvent, purge valve. The end pieces are placed at the end of the manifold. Manifold without flowmeter System layout

Ordering Description Type Code no. Manifold set 2+2 FHF-2 088U0502 Manifold set 3+3 FHF-3 088U0503 Manifold set 4+4 FHF-4 088U0504 Manifold set 5+5 FHF-5 088U0505 Manifold set 6+6 FHF-6 088U0506 Manifold set 7+7 FHF-7 088U0507 Manifold set 8+8 FHF-8 088U0508 Manifold set 9+9 FHF-9 088U0509 Manifold set 10+10 FHF-10 088U0510 Manifold set 11+11 FHF-11 088U0511 Manifold set 12+12 FHF-12 088U0512 Manifold set 2+2, with flowmeter FHF-2F 088U0522 Manifold set 3+3, with flowmeter FHF-3F 088U0523 Manifold set 4+4, with flowmeter FHF-4F 088U0524 Manifold set 5+5, with flowmeter FHF-5F 088U0525 Manifold set 6+6, with flowmeter FHF-6F 088U0526 Manifold set 7+7, with flowmeter FHF-7F 088U0527 Manifold set 8+8, with flowmeter FHF-8F 088U0528 Manifold set 9+9, with flowmeter FHF-9F 088U0529 Manifold set 10+10, with flowmeter FHF-10F 088U0530 Manifold set 11+11, with flowmeter FHF-11F 088U0531 Manifold set 12+12, with flowmeter FHF-12F 088U0532 Manifold set 2+2, basic FHF-2B 088U0542 Manifold set 3+3, basic FHF-3B 088U0543 Manifold set 4+4, basic FHF-4B 088U0544 Manifold set 5+5, basic FHF-5B 088U0545 Manifold set 6+6, basic FHF-6B 088U0546 Manifold set 7+7, basic FHF-7B 088U0547 Manifold set 8+8, basic FHF-8B 088U0548 Manifold set 9+9, basic FHF-9B 088U0549 Manifold set 10+10, basic FHF-10B 088U0550 Manifold set 11+11, basic FHF-11B 088U0551 Manifold set 12+12, basic FHF-12B 088U0552 End section - automatic airvent and purge valve FHF-EA 088U0580 End section - manual airvent and purge valve FHF-EM 088U0581 End caps -set FHF-E 088U0582 Connection pieces - set FHF-C 088U0583 Reduction bushes/pieces -set 1" - 3/4" FHF-R 088U0584 2

Ordering Description Type Code no. Mounting brackets - set FHF-MB 088U0585 2 x ball valve 1 with tail piece - for connection to manifold and for blocking of floor heating system 1 x thermometer 0-60 C Ø35mm - for flow/return temperature measurement Thermal actuator, 24V, NC, Danfoss RA connection to valve Thermal actuator, 230V, NC, Danfoss RA connection to valve Thermal actuator, 24V, NC, with end switch, Danfoss RA connection to valve FHF-BV 088U0586 FHD-T 088U0029 TWA-A 088H3110 TWA-A 088H3112 TWA-A 088H3114 Description Type Code no. 12x2 mm 13x2 mm 013G4152 013G4153 Compression fittings for PEX tubing in accordance with DIN 16892/16893. Max working pressure - 6 bar Test pressure 10 bar Max flow temp. 95 C G ¾ Internal thread Max flow temperature given by the tube manufacturer must not be exceeded. 14x2 mm 013G4154 15x2,5 mm 013G4155 16x1,5 mm 013G4157 16x2 mm 013G4156 16x2,2 mm 013G4163 17x2 mm 013G4162 18x2 mm 013G4158 18x2,5 mm 013G4159 20x2 mm 013G4160 20x2,5 mm 013G4161 12x2 mm 013G4182 Compression fittings for ALUPEX tubing. Max working pressure - 6 bar Test pressure 10 bar Max flow temp. 95 C G ¾ Internal thread Max flow temperature given by the tube manufacturer must not be exceeded. 14x2 mm 013G4184 15x2,5 mm 013G4185 16x2 mm 013G4186 16x2,25 mm 013G4187 18x2 mm 013G4188 20x2 mm 013G4190 20x2,5 mm 013G4191 Compression fittings for STEEL and COPPER tubing. Max working pressure - 6 bar Test pressure 10 bar Max flow temp. 120 C G ¾ Internal thread 10 mm 013G4120 12 mm 013G4122 14 mm 013G4124 15 mm 013G4125 16 mm 013G4126 18 mm 013G4128 3

Capacity/ commissioning The pre-setting of the manifold valves determines the flow in the floor heating tubes and is therefore an important factor for obtaining optimal hydraulic balance in the system. A correct hydraulic balance is important if optimal comfort shall be achieved with a minimum of energy consumption and is easily carried out following the example shown below. Room 1 Example 1 Determine longest tube/largest room 25 m 2 2 Desired cooling (dt) 5 C (typical) 3 Determine heat requirement for the room 50 W/m 2 4 Conversion factor 1,16 5 Calculation of flow for the room Q (l/h) = 50 W/m 2 x 25 m 2 5 C x 1,16 Room 2 6 Determine area for the next room 15 m 2 Q (l/h) = 216 l/h 7 Calculation of flow for the room (dt and heat requirement is assumed identical for the rooms in this case) Q (l/h) = 50 W/m 2 x 15 m 2 5 C x 1,16 Q (l/h) = 129 l/h Pre-setting for manifold with flowmeter: Room 1 N Room 2 5 Manifold with flowmeter Pre-setting for manifold without flowmeter: Room 1 N Room 2 6 Manifold without flowmeter 4

Pre-setting the manifold valves The diagrams shows the capacities for each heating circuit at different pre-settings of the manifold valves. Please note that the capacities are slightly different depending on whether a manifold with flowmeter or a manifold without flowmeter has been chosen. Based on the above calculations and capacity diagrams each manifold valve is pre-set by rotating the red ring until the correct value on the ring is in-line with the sight mark on the valve. Design Item Description Material 1 Sightglass Heat resistant plastic 2 Flowmeter nut Brass, CuZn39Pb3 3 Flowmeter insert Brass, CuZn39Pb3 4 Supply manifold body Brass, CuZn40Pb2 5 O-ring EPDM 6 Union for compression fitting Brass, CuZn40Pb2 Supply manifold with flowmeter Supply manifold without flowmeter Item Description Material 1 Lock washer Brass, CuZn40Pb2 2 O-ring EPDM 3 Valve spindle Brass, CuZn40Pb2 4 O-ring EPDM 5 Valve tube Brass, CuZn40Pb2 6 Supply manifold body Brass, CuZn40Pb2 7 O-ring EPDM Return manifold with control valve Item Description Material 1 Gland seal - 2 Pre-setting ring PBT 3 Valve body Brass, CuZn40Pb2 4 Return manifold body Brass, CuZn40Pb2 5 K v insert Brass, CuZn39Pb3 6 O-ring EPDM 7 Union for compression fitting Brass, CuZn40Pb2 5

Operation conditions Max differential pressure 0,6 bar Max working pressure 10 bar/ 6 bar Max test pressure 16 bar/10 bar Max flow temperature 90 C Dimensions Type 2+2 3+3 4+4 5+5 6+6 7+7 8+8 9+9 10+10 11+11 12+12 L1 (mm) 111 161 211 261 311 361 411 461 511 561 611 6

Type 2+2 3+3 4+4 5+5 6+6 7+7 8+8 9+9 10+10 11+11 12+12 L1 (mm) 111 161 211 261 311 361 411 461 511 561 611 7

60045 000 01