Control Card VLT FC Series

Similar documents
Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

Installation Instructions 500 A Current Sensor Kit for F1 F4/F8 F13 Enclosure Sizes VLT Series FC 102, FC 202, and FC 302

Installation Instructions 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Installation Instructions In-bottom/Out-back Cooling Kit for E4h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

Installation Instructions In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, and FC 302

Disassembling and assembling isave 21

Disposal declaration Frequency Converters Frame Size: D1, D2, D3, D4, D5, D6, D7 and D8 (New Generation) Production Place: USA and India

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Changing pistons APP and APP 16-22

INSTRUCTIONS Servicing PAH

Disassembling and assembling PAH , PAHT and PAHT G

INSTRUCTIONS INSTALLATION OF LOAD-SHARE TERMINALS FOR VLT DRIVES

Changing pistons APP 21-43

Crankcase pressure regulator Type KVL

Installation Guide. DEVIreg 527. Electronic Time Regulator.

Crankcase pressure regulator Type KVL

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Marine Annex covering all VLT Drives Note

INSTRUCTIONS 177R0076 INSTALLATION OF TOP AND BOTTOM COVERS FOR IP00 FRAMES D3, D4 & E2 INTO RITTAL ENCLOSURES

Infocal 9 Energy calculator for heating and cooling applications

Maneurop reciprocating compressors MT - MTZ - NTZ

SSM Floor Heating Manifold

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Advanced efficiency, precision cooling Design an HVAC system like no other

Premounted Midi Shunts

Advanced efficiency, precision cooling Design an HVAC system like no other

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Advanced efficiency, precision cooling Design an HVAC system like no other

Starting Torque Limiter Type TCI (Soft Start)

SonoSensor 30 Ultrasonic flow sensor

Installation Guide VLT Parallel Drive Modules

Assisted lift operated 2/2-way solenoid valves Type EV251B

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

MAKING MODERN LIVING POSSIBLE. Instruction Manual VLT AutomationDrive FC 300

Reliable season change

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

Manual presetting valve MSV-C

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Operating Guide VLT AQUA Drive FC 202

NLE12.6MF.2 Energy-optimized MBP Compressor R134a V 50/60Hz

3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC

TYPE APPROVAL CERTIFICATE

5. Installation on Pedestal - IP 21 / IP 54 Units 43

MAKING MODERN LIVING POSSIBLE. Instruction Manual. VLT AutomationDrive FC 300, kw

Valve bodies type RA-N with integrated presetting

Floor heating system, heating circuit with FHV-A in flow.

Section 1.0 Warnings Section 2.0. Section 3.0. Section 4.0. MCD3000 Inside Delta Connection Kits. Contents

ON/OFF zone valves AMZ 112, AMZ 113

The precise step to take

X-tra Collection for designer radiators and bathroom towel rails

50% Raise your efficiency to a higher level. Equipped for silence and top performance. Optyma Plus TM New Generation

3 Internal Frequency Converter Operation 43

One. The performance of your wind turbine relies on the quality of its small components. ia.danfoss.com. Brochure Mobile Hydraulic

The Danfoss Turbocor Portfolio of Oil Free Compressors

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

ATEX instruction APP S 674 pumps APP S , APP S and APP S

Brake Resistor Design Guide. How to Read this Design Guide 3 Abbreviations 4. Safety Precautions 5 CE Conformity and Labelling 5

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Quick Reference Parts Manual Variable Displacement Motor Series 20, series powersolutions.danfoss.com

Manual Presetting Valves LENO MSV-B

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Pressure relief controller AVA (PN 25)

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

ELIMINATOR Hermetic filter drier Types DML and DCL

MAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors R407C - R22 - R410A 60 HZ QUICK REFERENCE

Danfoss VDHT Solenoid Valves WATER SOLUTIONS

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

PAHT pump PAHT X

TYPE APPROVAL CERTIFICATE

Danfoss Saginomiya 4 - Way Reversing Valves

Manual presetting valves LENO MSV-BD

Steering Priority Valve OLS 160

Optyma TM Slim Pack Just mount, braze and plug

Oil pump type RSA. Catalogue 1. Burner Components

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

APP pump instruction APP and APP 16-22

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Power Modules to meet your exact Requirements

Service Guide VLT OneGearDrive

APP pump instruction APP 21-43

Nessie High-Pressure Pumps for technical water, type PAH

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators

Danfoss VLT Drives Product Overview

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

TCU Flushing Manifold and RTD Installation

Reliable season change

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

APP S pumps APP S / APP S / APP S 21-38

ICV with flanges: Danfoss now makes retrofit easy

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

Transcription:

These instructions describe the replacement of the control card in: VLT HVAC Drive FC 102. VLT Refrigeration Drive FC 103. VLT AQUA Drive FC 202. VLT AutomationDrive FC 301/FC 302. VLT Lift Drive LD 302. Safety Instructions Only Danfoss authorized, qualified personnel is allowed to repair this equipment. WARNING DISCHARGE TIME The frequency converter contains DC-link capacitors, which can remain charged even when the frequency converter is not powered. High voltage can be present even when the warning LED indicator lights are off. Failure to wait the specified time after power has been removed before performing service or repair work can result in death or serious injury. Stop the motor. Disconnect AC mains and remote DC-link power supplies, including battery back-ups, UPS, and DC-link connections to other frequency converters. Disconnect or lock PM motor. Wait for the capacitors to discharge fully. The minimum duration of waiting time is specified in Table 1.1 to Table 1.5. Before performing any service or repair work, use an appropriate voltage measuring device to make sure that the capacitors are fully discharged. Danfoss A/S 03/2017 All rights reserved. MI93A102

4 7 15 20 30 40 200 240 1.1 3.7 kw 5.5 45 kw (1.50 5 hp) (7.5 60 hp) 380 480 1.1 7.5 kw (1.50 10 hp) 315 1000 kw (450 1350 hp) 400 90 315 kw (121 450 hp) 500 110 355 kw (150 500 hp) 525 75 315 kw (100 450 hp) 525 600 1.1 7.5 kw (1.50 10 hp) 690 90 315 kw (100 350 hp) 525 690 1.1 7.5 kw (1.50 10 hp) 11 90 kw 400 1400 kw (500 1550 hp) 450 1400 kw (600 1550 hp) Table 1.1 Discharge Time, VLT HVAC Drive FC 102 4 7 15 20 40 200 240 0.25 3.7 kw 5.5 37 kw (0.34 5 hp) (7.5 50 hp) 380 480 0.25 7.5 kw (0.34 10 hp) 110 315 (150 450 hp) 355 450 (500 600 hp) 355 560 (500 750 hp) 525 600 0.75 7.5 kw (1.0 10 hp) 525 690 1.5 7.5 kw (2 10 hp) 11 75 kw 55 400 450 630 (600 750 hp) 450 800 (600 950 hp) Table 1.2 Discharge Time, VLT Refrigeration Drive FC 103 4 7 15 20 30 40 200 240 0.25 3.7 kw 5.5 45 kw (0.34 5 hp) (7.5 60 hp) 380 480 0.37 7.5 kw (0.5 10 hp) 110 315 kw (150 450 hp) 315 1000 kw (450 1350 hp) 355 560 kw (500 750 hp) 525 600 0.75 7.5 kw 400 1400 kw (1 10 hp) (400 1550 hp) 525 690 1.1 7.5 kw (1.5 10 hp) 11 90 kw (10 100 hp) 75 400 kw 450 800 kw (450 950 hp) Table 1.3 Discharge Time, VLT AQUA Drive FC 202 2 Danfoss A/S 03/2017 All rights reserved. MI93A102

4 7 15 20 30 40 200 240 0.25 3.7 kw (0.34 5 hp) 5.5 37 kw (7.5 50 hp) 380 500 0.25 7.5 kw (0.34 10 hp) 90 200 kw (150 350 hp) 250 500 kw (450 750 hp) 250 800 kw (450 1350 hp) 315 500 (500 750 hp) 400 90 315 kw (125 450 hp) 500 110 355 kw (150 450 hp) 525 55 315 kw 525 600 0.75 7.5 kw (1 10 hp) 525 690 1.5 7.5 kw (2 10 hp) 11 75 kw 37 315 kw (50 450 hp) 355 1200 kw (450 1550 hp) 355 2000 kw (450 2050 hp) 355 710 kw (400 950 hp) 690 55 315 kw Table 1.4 Discharge Time, VLT AutomationDrive FC 301/FC 302 4 15 380 480 0.25 7.5 kw (0.34 10 hp) 11 75 kw Replacing the Control Card Table 1.5 Discharge Time, VLT Lift Drive, LD 302 Item Supplied The following item is supplied: Control card Tools Only 2 tools are required for replacing the control card. Torx 10 screwdriver Flat-head screwdriver Additional Items Required VLT frequency converter 1 LCP 2 Blind cover Illustration 1.1 LCP and Blind Cover MI93A102 Danfoss A/S 03/2017 All rights reserved. 3

1. Remove the LCP and the blind cover. 2. Remove the LCP cradle. Illustration 1.2 Removing LCP Illustration 1.4 Removing LCP Cradle Illustration 1.3 Removing Blind Cover 4 Danfoss A/S 03/2017 All rights reserved. MI93A102

3. Remove all control cables from the metal bracket (spring-loaded). 4. Remove any A, B, or C options that may be installed. 5. Remove the I/O terminals. 6. Unscrew the 3 T10 screws and remove the cable shield. 7. Remove the plastic cover underneath the cable shield. 1 Location of A option 2 Location B option 3 I/O terminals Illustration 1.5 Location of Options and I/O Terminals 1 Cable shield 2 MCO ribbon cable 3 T10 screws Illustration 1.6 Location of Cable Shield, Screws, and MCO Ribbon Cable MI93A102 Danfoss A/S 03/2017 All rights reserved. 5

8. Unscrew the 2 T10 screws holding the control card EMC shield (4 screws if MCO is installed). 8a If MCO is installed, remove the MCO ribbon cable. 9. Remove the control card EMC shield. 10. Unscrew the 3 T10 screws and remove them. 11. Gently remove the control card from the upper-right socket. Avoid overbending and contact with electronic components. 1 T10 screws 2 EMC shield 1 Control card 2 T10 screws Illustration 1.8 Control Card and T10 Screws Illustration 1.7 Screws and EMC Shield Re-assemble the new control card in reverse order. Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss A/S Ulsnaes 1 DK-6300 Graasten vlt-drives.danfoss.com 130R0788 MI93A102 03/2017 *MI93A102*