Hynds Telco and Electrical Pit System

Similar documents
Hawle Haku PE Pipe Saddle

GRAF EcoBloc Stormwater Management System

GRAF EcoBloc Stormwater Management System

The Sika Solution x 600 x 700H / 900H. Class D. Roadway Installation Guidelines p 9-11

A monolithic drainage system designed to accept and convey large volumes of rainwater. Product Attributes

Pre assembled for quick installation. One fitting is able to connect multiple pipes materials. Approvals/Standards BS EN ISO 9001

Galvanised Mild Steel Grates For cast and in-situ applications.

Knife Gate we PIPE ( ) Resilient Seat Highly Ground Gate. W4.18 Hydrotite Knife Gate Valves Stainless Steel December 2012

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries

Domestic Traditional Pits DOMESTIC TRADITONAL PITS

Industries. Septic Tanks

HYDRA-CELL PIT SYSTEM KNOCK-OUT PIT

STORA-DRAIN PARKING POLYESTER CONCRETE DRAINAGE CHANNEL GALVANIZED PROFILE

DURISOL ANCHORED RETAINING WALL SYSTEM (DARWS)

Viking Johnson Ultragrip Restraint Couplings

The Pump Matic Range

FOOTBRIDGE ELEVATION SCALE 1:100

PLUG VALVE we PIPE ( ) Twice the tensile strength of cast iron Greater yield strength than steel

INSTALLATION GUIDELINES

CATALOGUE SEWAGE MANHOLES

GB-250. Submittal Specifications Installation Application Specific Details

ABS lifting station Synconta

2018 CATALOGUE CONCRETE PITS COVERS & GRATES ...& A WEALTH OF KNOWLEDGE. Phone:

13-17 Endurance Avenue Queanbeyan NSW 2620 Ph: Fax:

Seal on disc we PIPE ( ) Double Flanged Seal On Disc AS 4795:2006 Compliant

Reinforced edge channels KE-100

Aluminum Box Culverts

Concrete Pipes 62 Traditional Manholes Sealed Manholes 66 Retaining Walls 67 Boc Culverts / Gully Pots 68 Inspection Chambers 69

Lifting Station Type ABS Synconta 900B

ACO Water Management: Civils + Infrastructure

B SERIES. Helical bevel Gear Reducers

PARKING type SC. The polyester concrete drainage channel with 2mm protective edge profi le IMC SC EN

ABCD BFDC BEDA AB CDEFCC

COMPOSITE ACCESS COVER INSTALLATION GUIDE

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

Heavy Duty Commercial Pits

ACO Water Management: Civils + Infrastructure

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

Installation Manual. Talon Series. Portable Vehicle Scale by Fairbanks Scales, Inc. All rights reserved.

SECTION 17 FIRE HYDRANT ASSEMBLIES General

Infrastructure & Power. FP M c Cann. Tel: +44(0) Fax: +44(0)

AS3996:2006 LOAD CLASSIFICATIONS

NLS and NLT, method A, completely supported in prepared pit (welding)

EPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data

McCRORY & WILLIAMS, INC. HILLCREST ROAD CONNECTOR MCR ROADWAY ITEMS

ACO Water Management: Urban + Landscape Civils + Infrastructure

8&#'03(& $*7*- XXX XFCGPSHF DPN BV JOGP!XFCGPSHF DPN BV

Energy ] Energy. BVCI manufacture and distribute a wide range of plastic and pre-cast concrete cable pits for the Energy sector.

ACO Water Management: Civils + Infrastructure

Weldlok Drainage Products

HDPE Flap Valve A flap valve is a simple, one-way valve used in surface water drainage associated with rivers, estuaries and seawater outfalls.

INDEX. Growing Beyond Boundaries 03

Covers and Frames Ductile Iron Covers and Frames Gully Grates D Surface Boxes 270 Steel Covers and Frames

GREASE INTERCEPTOR REQUIREMENTS

cable management Pit / Vault System Series

Commercial Sized Drainage

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

PRECAST CONCRETE SPECIALISTS. Product Catalogue

TECHNICAL type SE. The polyester concrete drainage channel with 4mm protective edge profi le IMC SE EN

Oil Interceptor Listings

Ohio Department of Transportation Official Bid Tabulation Jolene M. Molitoris, Director

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

kerb and gully range fast delivery on ex-stock items to any postcode nationwide

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

Cable, Utilities and Various Network Solutions. Access Covers

2150 F&I 4" PVC pipe LF 100 $ F&I 6" PVC pipe LF 100 $ F&I 8" PVC pipe LF 100 $ 90.00

Cable-Tight Wire Management System

Pumps. Everything flows quickly and efficiently. The pump program from Wacker Neuson.

CONTENTS. Foreword...iii. 1. Introduction...1

ANSI Tier Selection and Placement in Non-Deliberate Vehicular Traffic Applications

Midwest Roadside Safety Facility

Separators. industrieblick Fotolia.com. For indoor or below ground installation ACO Light Oil Separators Coalisator-P

RAINWATER HARVESTING SYSTEMS

POWER & INFRASTRUCTURE SOLUTIONS

ACO Modular. ACO Product catalogue. Modular Stainless Steel Channel Drainage System. Modular 20. Modular 125. Modular 200. Floor Drainage systems

Add 7% to cater for any fittings/fabrication at the bridge, and anchor blocks (as directed by the Eng. On site) Total

VERTICAL DELINEATION

Above ground hydrants Modifi cation rights reserved

8&#'03(& $*7*- XXX XFCGPSHF DPN BV JOGP!XFCGPSHF DPN BV

Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE)

On-the-Job Training Program. Overview of Training Programs

DC DRUM CUTTER. Your choice for rock or concrete wall and surface profiling, trenching, frozen soil or rock excavation and demolition.

Fertilizer Type B 2 CWT $ $ $60.00 $ $60.00 $ Sod Water 60 MGAL $60.60 $3, $30.00 $1, $30.00 $1,

Uniclass L L2123 EPIC J3413. CI/SfB (52.5) If9. Surface drainage for heavy duty traffic applications ACO RoadDrain

SOLFLO MAX LINEAR COLLECTION Linear catch basin connected with double bell outlet with integrated gasket and clips (DBIGC)

SITE PLANS ASSISTED LIVING REDEVELOPMENT

AUTOMATIC AIR VALVES For potable water

Polycarbonate manholes

infrastructure rotational moulding catalogue vrm - innovation for tomorrow edition iii

GRANOR STRUCTURAL SLIDE BEARINGS SERIES D

The Street Barrier Security Handbook

PACKAGED PUMP STATIONS

Water Cistern. Domestic Potable Water

MUNICIPAL WATER PRODUCTS OVERVIEW

TML TML. Socketless cast iron waste water system for civil engineering applications. Product information

BSERIES. Helicalbevel GearReducers

Series description: Wilo-Drain MTC

APPENDIX D. D.1 Macalloy Bars. Approximate safe working loads (kn) Appendix D - Proprietary Components (1/9) Stainless steel architectural ties

INSULATORS.

Ohio Department of Transportation Official Bid Tabulation Jerry Wray, Director

Transcription:

Hynds Telco and Electrical Pit System Scan for more information Technical Guide SP1.1 Hynds Concrete Access Chambers and Lids are designed specifically for the telecommunication and electrical industries. 03.15 DRAINAGE SURFACE SP1.1 Telco and Electrical Pit System Applications Telecommunication access chambers Electrical and general access chambers Drainage sumps Product Attributes Extensive size range Three strength class options Easily sealed Suitable for concrete, cast iron and aluminium lids Approvals/Standards Manufactured in accordance with NZ Transport wheel loading requirements Quality ISO 9001:2008 Quality Management Standard The go to organisation for civil and rural water product solutions

Hynds Concrete Access Chambers and Lids are designed specifically for the telecommunication and electrical industries. Manufacture Hynds Telecommunication and Electrical Pits are manufactured using an inverted single-pour process to ensure consistent quality and watertight sealing. All concrete chambers and lids are steel reinforced and are installed with external lifting anchors for handling onsite. All chambers are supplied with four external Swiftlift TM anchors for easy handling on site. Pulling pits and jointing chambers: 4 x 1.3 t Swiftlift TM anchors. C.B.D. Chamber and SF Tank: 4 x 2.5 t Swiftlift TM anchors. SP1.1 Telco and Electrical Pit System SURFACE PG 2 Installation Installation of Hynds Concrete Access Chambers is easy and simple. Excavate the pit to the required depth (allow some over excavation for a foundation). Prepare foundation with compacted hardfill. Connect ducting to the chamber as necessary. Backfill evenly around the chamber using selected material in well compacted layers, not exceeding 200 mm thickness per layer. Install sealant and fit lid Complete surrounds to suit requirements. Fig. 1 Concrete Access Chamber being lifted into position

Table 1 TELSPULL Product Range Product Code Gatic Cover and Frame + TELSPULL.LID/TELSPULL.LID175 Fig. 2 Pulling Pits, concrete lids and covers Traffic Type Design External Dimensions Internal Dimensions Weight TELSPULL.LID Softspots 6 x Ø 120 mm 1 x Ø 60 mm TELSPULL/TELSPULLHD Sika Cover Set + TELSPULLRISER Shipped from SP1.1 Telco and Electrical Pit System SURFACE PG 3 Pulling Pit TELSPULL Footpath/ Pedestrian TELSPULLHD Roadway 51 kn Wheel or 0.85 HN Lids TELSPULL.LID Footpath 40 kn Dual Wheel TELSPULL. LID Footpath 3.5 kn/m 2 1330 730 965 1200 600 900 741 Hamilton 40 kn Dual Wheel TELSPULL.LID175 Footpath 60 kn Dual Wheel Risers/Reducers TELSPULLRISER Footpath 40 kn Dual Wheel Gatic / Sika Cover and Frame Sets 1400 800 965 1200 600 900 1100 Hamilton / Palmerston N. 1400 800 No Opening 420 Auckland / Hamilton 1400 1000 Ø 610 mm Clear Opening 450 Hamilton 1400 1000 175 Ø 610 mm Clear Opening 560 Hamilton 1400 800 200 1200 600 200 207 Hamilton GATIC-02301135 Roadway D210 1482 812 100 1270 600 73 230 Auckland LD.AL.B31206 Roadway 80 kn 1379 707 57 1227 556 45 46 Auckland

TELSJOINT.LIDS Gatic Cover and Frame + TELSJT.LID / TELSJT.LID175 TELSJOINTRISER Sika Cover Set + TELSJOINT.LID SP1.1 Telco and Electrical Pit System SURFACE PG 4 Fig. 3 Jointing Chambers, concrete lids and covers Table 2 TELSJOINT Product Range Product Code Traffic Type Design External Dimensions Internal Dimensions Weight Softspots 8 x Ø 120 mm 1 x Ø 60 mm TELSJOINT / TELSJOINTHD / TELSJOINTHD17 Shipped from Jointing Chamber TELSJOINT Footpath/ Pedestrian 3.5 kn/m 2 1350 1050 1280 1200 900 1200 1184 Hamilton TELSJOINTHD Roadway 60 kn Wheel 1400 1100 1280 1200 900 1200 1734 Hamilton TELSJOINTHD17 Roadway 60 kn Wheel 1400 1100 1780 1200 900 1700 2410 Hamilton/ Oamaru Lids TELSJOINT.LIDS Roadway 60 kn Wheel 1410 1120 No Opening 580 Auckland/ Hamilton/ Oamaru TELSJT.LID Roadway 40 kn Wheel 1400 1100 Ø 610 mm Clear Opening 580 Hamilton TELSJT.LID175 Roadway 60 kn Wheel 1400 1100 175 Ø 610 mm Clear Opening 680 Hamilton Risers/Reducers TELSJOINTRISER Roadway 40 kn Wheel 1400 1100 200 1200 900 200 237 Hamilton TELSJOINT.LID Roadway 40 kn Wheel 1400 1100 100 1200 600 100 209 Auckland/ Hamilton Gatic / Sika Cover and Frame Sets GATIC-02301135 Roadway D210 1482 812 100 1270 600 73 230 Auckland LD.AL.B31206 Roadway 80 kn 1379 707 57 1227 556 45 46 Auckland

Table 3 TELSCBD Product Range Product Code Traffic Type Design External Dimensions Internal Dimensions Weight CBD Chamber Shipped from TELSCBDII Roadway 0.85 HN 2050 1450 1925 1850 1250 1800 4300 Hamilton Lids TELSCBDII Fig. 4 CBD Chamber and concrete lid 600 mm Ø opening TELSCBD.LID200 TELSCBD.LID200H Roadway 0.85 HN 2050 1450 200 Ø 610 mm Clear Opening 1340 Hamilton SP1.1 Telco and Electrical Pit System SURFACE PG 5 Risers/Reducers TELSJOINTRISER Roadway 40 kn Wheel 1400 1100 200 1200 900 200 237 Hamilton TELSJOINT.LID Roadway 40 kn Wheel 1400 1100 100 1200 600 100 209 Auckland/ Christchurch Table 4 Covers and Frames Product Code Product Description Design Weight DIMHMCFHS Maestro DI Cover & Frame - Ø600 mm Opening D400 73 DIMHTCFHS Twino DI Cover & Frame - Ø600 mm Opening D400 54

2400 900 600 2100 750 600 590 750 600 4 No. - 1FA120 Swiftlift TM 4-50 mm dia Duct holes@ 500 mm spacing 50 mm dia Duct Holes Side view - TELSLIGHT Scale: NTS Elevation - TELSLIGHT Scale: NTS 600 240 200 SP1.1 Telco and Electrical Pit System SURFACE PG 6 160 2400 450 Plan - TELSLIGHT.LID Scale: NTS Elevation - TELSLIGHT.LID Scale: NTS 610 200 20 900 Fig. 5 Light Chamber and lid Table 5 TELSLIGHT Product Range Product Code Traffic Type Design Transformer Chamber External Dimensions Internal Dimensions Weight Shipped from TELSLIGHT Roadway 0.85 HN 2400 900 750 2100 600 600 2180 Auckland Lids TELSLIGHT.LID Roadway 0.85 HN 2400 900 Ø 610 mm Clear Opening 825 Auckland TELSLIGHT.LIDHD Roadway 0.85 HN 2400 900 200 Ø 610 mm Clear Opening 1086 Auckland Table 6 Covers and Frames Product Code Product Description Design Weight DIMHMCFHS Maestro DI Cover & Frame - Ø600 mm Opening D400 73 DIMHTCFHS Twino DI Cover & Frame - Ø600 mm Opening D400 54

TELSPIT Kit Hynds TELSPIT kit is a versatile range of self-assembly telecom cable pulling pits. Every kit comes with the required galvanised nuts and washers, allowing a fast on-site assembly. Hynds Hybond Epoxy is the best option to get a good quality and durable bond between joints (Hybond is not included in the kit). Fig. 6 TELSPIT Self Assembly Kits dimensions Table 7 TELSPIT Cable Pulling Pits Product Range SP1.1 Telco and Electrical Pit System SURFACE PG 7 Product Code Traffic Type Design External Dimensions Internal Dimensions Weight (*) Soft spots Kit accessories Shipped from Self assembly kits TELSPIT.A Footpath 1370 700 615 1220 550 550 596 115 Kit 1 Auckland TELSPIT.B Footpath 1370 700 1065 1220 550 1000 928 115 Kit 1 Auckland TELSPIT.B.HD Roadway 1420 750 1090 1220 550 1000 1296 115 Kit 2 Auckland TELSPIT.C Footpath 2310 1480 915 2060 1230 800 3530 No softspots TELSPIT.D Footpath 1420 1360 965 1270 1210 900 1293 No softspots Precast option Kit 3 Kit 4 Auckland Auckland TELSPIT 740 740 680 580 580 600 480 130 - Auckland Kit 1: 4 x M12 x 100 grade 4.6 galv nuts ; 4 x 50 x 50 square washers Kit 2: 4 x M12 x 130 grade 4.6 galv nuts ; 4 x 50 x 50 square washers Kit 3: 4 x M12 x 160 grade 4.6 galv nuts ; 4 x 50 x 50 square washers Kit 4: 20 x M12 x 100 grade 4.6 galv nuts ; 20 x 50 x 50 square washers ; 4 x 75 x 50 x 6 Galv Angle Brackets (*) The weight value represents the total weight of the assembled kit

SP1.1 Telco and Electrical Pit System SURFACE PG 8 Fig. 7 TELSPIT Chamber Also refer to D1.8 Precast Concrete Channel & Duct System Branches Nationwide Support Office & Technical Services 09 274 0316 Disclaimer: While every effort has been made to ensure that the information in this document is correct and accurate, users of Hynds product or information within this document must make their own assessment of suitability for their particular application. Product dimensions are nominal only, and should be verified if critical to a particular installation. No warranty is either expressed, implied, or statutory made by Hynds unless expressly stated in any sale and purchase agreement entered into between Hynds and the user.