Circular Fire Dampers

Similar documents
Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

7/S5 FIRE DAMPER FD40. v 2.9 (en)

Low Leakage Steel Door

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

CFSD Series. Product Description

Motorized Fire Dampers

Multileaf damper with actuator

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Weather-Resistant Louvres

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

Ceiling swirl diffusers

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

BFN(T) Veerteruggangmotor Belimo Servomoteur Belimo Servomotor Belimo K129-A-08/2015

Ceiling swirl diffusers

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Parts and characteristics

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Marine Fire and Gas Dampers

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

VARYCONTROL VAV Dual Duct Terminal Boxes

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

IMP Klima. Swirl diffusers. Variable swirl diffusers

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV

PKI-C Cartridge Fire Dampers

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Systemair Fire Dampers

Mechanical mixing box MBM

Ceiling swirl diffusers with perforated face plate

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

TYPE EK-EU SMOKE CONTROL DAMPER

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

Type VSD35. Nominal length up to 1500 mm: one spigot

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Air Displacement Vent Units

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Ventilation grilles for installation into walls, sills or rectangular

Technical information

CR2. Circular fire damper C1-C 04/2010

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

LINEAR SLOT DIFFUSERS

Slot diffusers for ceiling installation

NSDZ. Swirl diffusers with adjustable air control blades

PRODUCTS BULLETIN PRODUCTS CATALOGUE

ceiling swirl diffuser DQJ

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

CRP. Commissioning damper, Ductwork Leakage Class 0

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

Ventilation grilles for installation into walls, sills or rectangular

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Fire/smoke damper EKO-SRBG1

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Systemair Fire Dampers

Fan - Powered Terminal Unit Series Flow

NYBORG AS N-6230 SYKKYLVEN, NORWAY TEL FAX

For installation into ductwork

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

CJ1. Air Cylinder. Double Acting: ø4/single Acting, Spring Return: ø2.5, ø4 CJ1B 4 5 U4. How to Order/Double Acting

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Fire/combustion gas damper EKO-JBG

MOTORIZED VOLUME DAMPER

Fire Damper BSK-RPR. with general building supervisory approval Z

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

Fire/combustion gas damper EKO-JBL

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

IMP Klima. Swirl diffusers. Variable swirl diffusers

TECHNICAL AND OPERATIONAL DOCUMENTATION

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

LINEAR SLOT DUFFUSERS

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

CONSTANTFLOW Volume Flow Controllers

Transcription:

A/6/2/EN/2 Circular Fire Dampers Type FRK / FRL TROX (outh Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za Website: www.troxsa.co.za

Contents Description Contents Description 2 Construction 3 tandard sizes Weight 4 Installation Details 4 Product Range 5 Functional Description Circuit Diagrams 6 Order Details 7 The TROX fire damper series FRK / FRL provides isolation of fire areas in venitlation and air conditioning systems. The construction and operation corresponds to the principal requirements of fire protection installations. The symetrical position of the damper blade facilitates installation into walls or ceilings independent of the direction of entry air flow. The external operation and control components - manual lever - position indicator - manual release enables the installed damper to be rapidly checked for correct functioning. The thermal holding device arranged within the casing has a release temperature of 72 C. The use of corrosion proof materials makes the damper almost free of maintenance. Materials: Casing and attachments of galvanised sheet steel. Alternatively: - Casing and attachments in stainless steel 2

Construction Types: FRL/FRK FRL Casing with galvanised sheet steel angle blade stops on all sides Damper Blade: 3mm plate Bearings: Brass Brushes Attachments galvanised sheet steel Thermal Release fusible link, release temperature 72! C a Casing b Damper Blade c Manual Lever d Closing pring (Type FRL: tension spring, Type FRK: torsion spring) FRK Casing galvanised sheet steel Damper Blade: 3mm plate Bearings: Brass Brushes Attachments galvanised sheet steel Thermal Release via glass cartridge, release temperature 72! C e Locking Plate f Inspection Panel g Fusible link or glass cartridge h Blade stop (FRK-F without stops) Type: FRL 150 1 5 8 4 3 DA NW (DA) 7 6 2 L = 400 Type: FRK 150 1 NW (DA) 3 2 4 7 L = 300 Diagrams show type FRL and FRK external controls right hand side R viewed in direction of arrow (not necessarily the direction of air flow) 3

tandard izes Installation Details Type: FRL ize x D 1 in mm x D A in mm Free cross section area in m 2 Type FRL 315 322 382 0.062 400 404 464 0.104 500 507 567 0.171 630 638 708 0.280 Type: FRL x D A in mm Free cross section area in m 2 Type FRL 100 99 0.005 125 124 0.009 160 159 0.016 200 199 0.026 250 249 0.043 315 314 0.070 DA + 120 DA + 40 250 150 150 150 4 Gap s must be filled with mortar or concrete. The fire damper can also be installed during construction of the masonry wall or during concreting. The peripheral gap s is then not required. During installation ensure that the casing of the fire damper is not distorted otherwise it s operation can be affected. All dampers can be installed in a ceiling slab with the long end of the open damper blade above or below the slab.

Product Range Construction or Construction variant Combined with Code With fusible link (tandard construction) tandard fusible link - 72 C Belimo BLF 230V/24V spring return actuator Thermal release mechanism (single action only) BLF_T Built in limit switches for open and closed position Replacement thermal trip Tf2 available ZBAE72 Belimo BFL/BFN 230V/24V spring return actuator Thermal release mechanism (single action only) B VT Built in limit switches for open and closed position Replacement thermal trip Tf2 available ZBAE72 pare fusible links optional 05GX-G157-A 5

Order Details Order Code FRK/FRL- - R / DIAMETER X L / 304 tandard sizes Diameter x L in mm L =300 or 400 E = Fusible link = Electric Actuator (Type BLFT) Material: FDF (Galvanised as standard) E 304 = tainless steel 304 E 316 = tainless steel 316 External Control: R = Right hand side L = Left hand side (if not specified R is supplied) pecification Text Circular fire dampers for the isolation of fire zones in air conditioning systems, certified to AB 193:2004 Description of materials, construction variants, accessories, etc. can be taken from the publication. Order Example Make: TROX Type: FRK-E-BLF230T /315 X 300 / 304 FRL--R / 400 x 400 /304 6

Design changes reserved All rights reserved TROX (outh Africa) (Pty) Ltd October 2005