and solid bottom 10 straight sections 72 Fittings 42 Covers 77 Splices & connectors 24 accessories Metallic 26 long-span tray

Similar documents
Series 1 Steel - Accessories

Series 1 Steel - Straight Sections

T&B Cable Tray. In this section...

Series 1 Steel - Straight Sections

[ ] ] [ 6a2O s6 Height B PW CABLE TRAY PW CABLE TRAY

Series 1 Steel - Straight Sections

Series 3 & 4 Stainless Steel - Accessories

Cable Tray Straight Sections Pages Fittings Pages Inside Vertical Bends. 90 Page Page Page Page 1-15

Cable Tray Ladder, Trough, Channel, Under Floor, Shielded CH-117O

Series 2, 3, 4, & 5 Steel - Accessories

Series 2, 3, 4, & 5 Aluminum - Accessories

Series 2, 3, 4, & 5 Aluminum - Accessories

CABLE TRAY SURFACE RACEWAY J-HOOKS IN-FLOOR SYSTEMS POWER POLES DESK PEDESTALS CHANNEL TRAY

Channel Cable Tray - Accessories & Fittings

ADDER SYSTEM CABLE L

Series 2, 3, 4 Steel Cable Ladder Steel Cable Ladder, Series 2, 3, 4 & 5

ACCESSORIES QUICK CONNECTOR COVER BRACKETS BARRIER CUSTOM TEES & CROSSES

Series 2, 3, 4, & 5 Aluminum - Straight Sections

KwikSplice Aluminum Cable Tray - Straight Sections & Accessories

Series 3 & 4 Stainless Steel - Accessories

REDI-RAIL - Accessories

CTSCL-10. Steel Cable Ladder Cable Support Systems

REDI-RAIL - Accessories

I N D U S T R I E S, I N C. MARINE I-BEAMS LADDER SYSTEMS

STEEL CABLE TRAY LADDER

CLSME-12. NEMA 12B Rated Aluminium Cable Ladder System

Cable Tray CT2D-18. Tray2Day SM. cable tray service program

UNITED STRUCTURAL PRODUCTS

T&B Cable Tray. Metallic Aluminum. Covers. Number Selection

PAINT READY CABLE TRAY

Accessories, Splices and Connectors

Steel Ladder Cable Trays & Accessories

Swifts cable ladder ancillary items

Cent-R-Rail Systems. WARNING: Do NOT use as a walkway, ladder or support for personnel. Cent-R-Rail. Cable Tray Systems

The obvious choice in piping cushion clamp assemblies since 1966

FRP/GRP Solutions for Cable Management Systems

EZTray. Cable Management Made Easy

HDMANN. FRP Solutions for Cable Management Systems. cable management system. Cable Tray Instrumentation Tray Accessories

Table of Contents. Kit Maximum Examples Index by Kit Number Terms and Conditions...Inside Back Cover

ELECTRICAL ACCESSORIES FOR 1 5 8" (41 MM) WIDTH SERIES CHANNEL

FIBER TROUGH CABLE TRAY CATALOG

229 B-Line series Pipe Hangers & Supports

JEEP WRANGLER P Q 2X R 4X. K 2x. G 12x. F 2x N. Front Bumper # AD, , AC, # , AC and AC

Table of Contents. Wire Cable Tray. Underfloor. Accessories. Index. pages 1-9. pages pages pages pages

Manufacturing Facilities. Sheet Metal Connectors, Inc. is proud to be a member or affiliated with the following associations;

Hi-Tech specially designed components allow for fast and easy assembly.

Trough, Wireway & Strut Attributes

Uses, Certifications, and Standards STRUT FITTINGS,BF-FTGS,MISCELLANEOUS

NEC 2011 Code Changes

Table of Contents. Type: UL/TG/ST 4. Type: UL/TU/ST 13. Type: UL/TT/ST or UL/TC/ST 22. Type: UL/TR/ST 34. Type: UL/LZ/ST 53.

General Introduction

VENT FLASHINGS GALVANIZED STEEL

Pipe Hangers. Pipe Hangers. Pipe Hangers & Supports

Cable Support Systems Admiralty Pattern Tray Cable Ladder Type 2/30 Cable Ladder Type 3/50 K-1000 Channel KT3/KT5 Ladder Tray

ABN Quality Endorsed Company ISO9001 Lic No EDITION 2

NEMA CABLE LADDER [GENERAL INFORMATION]

WB24- W -120 CHOOSE TRAY LENGTH WIDTH CHOOSE TRAY LENGTH VENTILATED 10 FT 12 FT 20 FT 24 FT 4, 8, 12, 14, 18, 20 & N/A N/A N/A

Saving you Time, Saving you Money, Putting you First! CENTER HUNG TRAY. Width Length in Inches

PRODUCT CATALOG. 2010, Halex/Scott Fetzer Company TABLE OF CONTENTS. LIQUID Liquid-Tight Conduit Fittings

accqpulse Velocity Profiler Sensor Installation Guide

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

Pipe Hangers. 47 B-Line series Pipe Hangers & Supports

A century of Excellence... a legacy of Quality

Quik-Spec Coordination Panelboard A fusible panelboards

Ceiling and Inline Fans

Actuator Products Rodless Cylinders. GDL Series. Material specifications. Specifications OSP-P. Series. Series P1X. Series P1Z.

SECTION HVAC POWER VENTILATORS

Wire ø in. Cat. No. ETQ 2002SS *ETQ 2004SS *ETQ 2006SS

Standard Product. Cable Pathway QUICK TRAY PRO

Roof & Sidewall Mounted

Product Catalogue. Cable Management Solutions

Frequently Asked Questions

C OMMERCIAL SOLUTIONS

TABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44

Cable & Wire Management

Pipe/Conduit Clamps & Hangers

230 kv Aluminum Bolted Bus Supports TYPE 16300, 16500, Ordering Information. or

Our mission is to become the supplier of choice for gas venting products and solutions.

High Density Network Rack Series

MASTER PRICE LIST & CATALOG

Specifications. UL 1777 and ULC S641 System. Combustion Air System-DuraTech and DuraPlus HTC

WIREMOLD Wallduct Raceway Systems

NEW All Biomass Chimney components are available in matte black. Just add "B" to the end of the part numbers you are ordering.

Cable Support Systems. order guide. Australia s leading range of cable and pipe support systems.

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

Quik-Spec Coordination Panelboard A fusible panelboards

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

CUSTOM VENTILATED AWNINGS

Chicago Metallic 200 Snap Grid 15/16

T&B Cable Tray. Nonmetallic Strut Systems NM -SS P- 100 ( ) ( ) Channels

Americraft is dedicated to assist you, our customer, in all aspects of your air moving requirements.

General Cable Support Information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

All fitting are offered at 300mm Radius as standard and others Radius available on request.

Cable & Pipe Supports

PRODUCT INDEX PRODUCT INDEX. Item Page Item Page Item Page

Swifts XRF extra heavy duty return flange straight lengths

PIPE/CONDUIT CLAMPS, SUPPORTS AND HANGERS FOR 1 5 8" (41 MM) WIDTH SERIES CHANNEL

BRACKETS, MOUNTS & HARDWARE

Wire Mesh Safety Grips

Transcription:

P CLE TY LDDE, Trough & Solid ottom ITY luminum Tray 10 straight sections Fittings 20 Covers 22 splices & connectors accessories Metallic 26 long-span tray metallic 28 steel tray 30 stainless Steel tray 32 Fittings 42 Covers 45 splices & connectors 49 CCESSOIES 57 Fasteners 58 Firestop Systems 60 eference Information 63 ung options Fiberglass 70 straight sections 72 Fittings 76 Covers 77 Splices & connectors 78 accessories The P Line of cable tray s is offered in a ide variety of sizes, designs and finishes to meet exacting industry standards. Choose from our extensive selection of rail, rung and bottom styles that are available in a variety of finishes. lso choose from fittings, accessories, fire stop systems and fasteners that ill complete your installation. Legrand representatives have the experience to insure that your cable management needs ill be fulfilled on time and to your specifications. MC Poer Cable Fill Table LDDE TY IDT (IN.) 2C ( G) MX NUME OF CLES PE * TN TypeMC lumrmor 3C ( G) 3C (G 4/0) 3C (500 kcmil) 6 35 cbls 31 cbls 3 cbls 2 cbls 9 52 cbls 45 cbls 5 cbls 3 cbls 71 cbls 63 cbls 7 cbls 5 cbls 18 107 cbls 94 cbls 11 cbls 7 cbls 143 cbls 6 cbls 15 cbls 10 cbls 30 178 cbls 157 cbls 18 cbls cbls 36 214 cbls 204 cbls 22 cbls 15 cbls * Vented cable tray only. 8.LEGND.us/cablofil

P CLE TY VENTED Tray options that meet the NEM standard for vented tray 25% of the cable bearing surface must be ventilated. NON-VENTED Tray material side rail heights Inches LDDE STNDD rung VENTILTED TOUG Corrugated SOLID ottom Corrugated SOLID ottom flat SEET Itray luminum 4 5 6 7 6", 9" and " rung spacing 7/8" ide ribs are ½" deep on 2" centers ith air vents 7/8" ide ribs are ½" deep on 2" centers Flat sheet over " rung spacing G long-span luminum ot-dip Galvanized Steel 8 10 9", " and 18" rung spacing N/ N/ N/ G steel ot-dip Galvanized Steel 4 5 6 7 6", 9" and " rung spacing 7/8" ide ribs are ½" deep on 2" centers ith air vents 7/8" ide ribs are ½" deep on 2" centers N/ Stainless steel L Stainless Steel 304L T Stainless Steel 316L 4 5 6 7 6", 9" and " rung spacing N/ N/ Flat sheet only F fiberglass Fiberglass 4 6 6", 9" and " rung spacing N/ N/ Flat sheet under " rung spacing Data Cable Fill Table LDDE TY IDT (IN.) LOD DEPT (IN.) Cat 5e 4-pr Plenum (.17 IN.) MX NUME OF CLES PE Cat 5e Cat 6e 4-pr 4-pr Non-Plenum Plenum (.19 IN.) (.22 IN.) Cat 6a 4-pr Plenum (.30 IN.) 6 3 396 cbls 317 cbls 236 cbls 7 cbls 9 3 594 cbls 476 cbls 355 cbls 190 cbls 3 793 cbls 634 cbls 473 cbls 254 cbls 18 3 1189 cbls 952 cbls 710 cbls 381 cbls 3 1586 cbls 69 cbls 947 cbls 509 cbls 30 3 1982 cbls 1587 cbls 1183 cbls 636 cbls 36 3 2379 cbls 1904 cbls 1420 cbls 763 cbls 6 4 527 cbls 422 cbls 314 cbls 169 cbls 9 4 803 cbls 643 cbls 480 cbls 258 cbls 4 1055 cbls 844 cbls 629 cbls 338 cbls 18 4 1582 cbls 66 cbls 944 cbls 508 cbls 4 2110 cbls 1689 cbls 59 cbls 677 cbls 30 4 2679 cbls 2145 cbls 1600 cbls 860 cbls 36 4 3215 cbls 2574 cbls 1920 cbls 1032 cbls LDDE TY IDT (IN.) LOD DEPT (IN.) Cat 5e 4-pr Plenum (.17 IN.) MX NUME OF CLES PE Cat 5e Cat 6e 4-pr 4-pr Non-Plenum Plenum (.19 IN.) (.22 IN.) Cat 6a 4-pr Plenum (.30 IN.) 6 5 660 cbls 529 cbls 394 cbls 2 cbls 9 5 991 cbls 793 cbls 591 cbls 318 cbls 5 1321 cbls 1058 cbls 789 cbls 4 cbls 18 5 1982 cbls 1587 cbls 1183 cbls 636 cbls 5 2643 cbls 2116 cbls 1578 cbls 848 cbls 30 5 3304 cbls 2645 cbls 1972 cbls 1061 cbls 36 5 3965 cbls 3174 cbls 2367 cbls 73 cbls 6 6 788 cbls 631 cbls 469 cbls 277 cbls 9 6 1189 cbls 952 cbls 710 cbls 381 cbls 6 1515 cbls 13 cbls 905 cbls 486 cbls 18 6 2273 cbls 1820 cbls 1357 cbls 730 cbls 6 3031 cbls 27 cbls 1810 cbls 973 cbls 30 6 3965 cbls 3174 cbls 2367 cbls 73 cbls 36 6 4758 cbls 3809 cbls 2841 cbls 1527 cbls metallic 9 For detailed material and finish descriptions, see page 6..LEGND.us/cablofil

ITY P CLE TY luminum connectors & fittings: Necessary connectors and fasteners are supplied ith all trays and fittings. Extra connectors for field cuts or spares must be ordered separately. safe load: lloable cable load in pounds per linear foot uniformly distributed. ased on tray ith standard rung on 9" centers and supported on simple beam ith safety factor of 1.5 per NEM VE1. CONCENTTED LOD: ll ladders ith solid rungs and trays ith corrugated bottoms ill support a 200 lb. concentrated load applied at the center of the tray in addition to the NEM-rated cable load ithout collapse. ail heigt (IN.) 4 5 Load DEPT (IN.) Nema Class available lengths (FT.) Ladder s (IN) tray system number ][ ][ MP TING 3 10 - - - 6 36 4 1000 3 C 10 20 - - 6 36 4C 1000 3 20-20 - 6 36 420 1600 4 C 10 20 - - 6 36 5C 1000 4 20-20 - 6 36 520 1600 5 C 10 20 - - 6 36 6C 1000 6 5 20-20 - 6 36 620 1600 5 20C - 20-6 36 620C 1600 5 C - - 20 30 6 36 6C 1600 6 C 10 20 - - 6 36 7C 1000 itray straight sections idths () inches 6 9 18 30 36 7 6 20-20 - 6 36 720 1600 6 20C - 20-6 36 720C 1600 6 C - - 20 30 6 36 7C 1600 rail heights () inches 10 4 5 6 7.LEGND.us/cablofil

P CLE TY vented corrugated solid corrugated solid bottom SUPPOT SPN (FT.) 6 8 10 14 16 18 20 22 26 28 30 SFE LOD DT (LS./FT.) / DEFLECTION (IN.) / SFETY FCTO 1.5 300 0.46 169 0.81 108 1.27 75 1.83 400 0.49 225 0.86 144 1.35 100 1.94 469 0.92 300 1.43 208 2.06 153 2.80 117 3.66 93 4.63 75 5.72 61 6.92 50 8. 400 0.28 225 0.50 144 0.78 100 1. 469 0.60 300 0.95 208 1.36 153 1.85 117 2.42 93 3.06 75 3.78 61 4.57 50 5.44 400 0. 225 0.42 144 0.66 100 0.95 469 0.43 300 0.67 208 0.96 153 1.31 117 1.71 93 2.16 75 2.67 61 3.23 50 3.84 400 0.78 278 1. 204 1.53 156 2.00 3 2.53 100 3. 81 3.78 66 4.49 400 1.04 294 1.41 225 1.84 178 2.33 144 2.88 119 3.48 100 4.14 84 4.86 71 5.64 61 6.47 400 0.15 225 0.27 144 0.42 100 0.61 469 0.32 300 0.50 208 0.72 153 0.98 117 1.29 93 1.63 75 2.01 61 2.43 50 2.89 ll Legrand aluminum and steel cable trays are Classified by UL as equipment grounding conductors per NEC 392.60. (UL File No. E60796) 400 0.55 278 0.78 204 1.07 156 1.40 3 1.77 100 2.18 81 2.64 66 3.14 400 0.90 294 1.23 225 1.60 178 2.03 144 2.50 119 3.03 100 3.60 84 4.23 71 4.90 61 5.63 itray straight section ctlog numbering example: ottom Type 09-4 -S144-06 VENTED ung Spacing ung Spacing ung Spacing ail eight nema Length* VC Vented Corrugated 4 4 class S0 0" non-vented 5 5 material S144 144" SC Solid Corrugated 6 6 S0 0" S Solid ottom 7 7 S288 288 * S144 and S0 are standard; S0 and S288 are available ith extended lead time. idth itray straight sections 11 For detailed material and finish descriptions, see page 6..LEGND.us/cablofil

P CLE TY 90 orizontal 90 Elbo 60 orizontal 60 Elbo 2 D 90 C 2 60 C D DIUS r IDT adius 2 r2 C D DIUS r IDT adius 2 r2 C D 36 6 18 21 21 36 36 9 21 39 39 27 27 42 42 18 30 33 33 48 48 36 39 39 54 54 30 42 45 45 60 60 36 48 51 51 66 66 6 30 33 33 60 60 9 33 36 36 63 63 36 39 39 66 66 18 42 45 45 72 72 48 51 51 78 78 30 54 57 57 84 84 36 60 63 63 90 90 6 42 45 45 84 84 9 45 48 48 87 87 48 51 51 90 90 18 54 57 57 96 96 60 63 63 102 102 30 66 69 69 108 108 36 72 75 75 114 114 36 6 18 20 1 /8 14 5 /8 35 20 1 /4 9 21 22 5 /8 17 5 /8 37 5 /8 21 3 /4 25 1 /4 20 5 /8 40 1 /8 23 1 /4 18 30 30 1 /2 26 5 /8 45 3 /8 26 1 /4 36 35 5 /8 32 5 /8 50 5 /8 29 1 /4 30 42 40 7 /8 38 5 /8 55 3 /4 32 1 /4 36 48 46 1 /8 44 5 /8 61 35 1 /4 6 30 30 1 /2 20 5 /8 55 3 /4 32 1 /4 9 33 33 1 /8 23 5 /8 58 3 /8 33 3 /4 36 35 5 /8 26 5 /8 61 35 1 /4 18 42 40 7 /8 32 5 /8 66 1 /8 38 1 /4 48 46 1 /8 38 5 /8 71 3 /8 41 1 /4 30 54 51 1 /4 44 5 /8 76 1 /2 44 1 /4 36 60 56 1 /2 50 5 /8 81 3 /4 47 1 /4 6 42 40 7 /8 26 5 /8 76 1 /2 44 1 /4 9 45 43 1 /2 29 5 /8 79 1 /8 45 3 /4 48 46 1 /8 32 5 /8 81 3 /4 47 1 /4 18 54 51 1 /4 38 5 /8 87 50 1 /4 60 56 1 /2 44 5 /8 92 1 /8 53 1 /4 30 66 61 5 /8 50 5 /8 97 3 /8 56 1 /4 36 72 66 7 /8 56 5 /8 102 1 /2 59 1 /4 itray fittings idths () inches 6 9 18 30 36 rail heights () inches 4 5 6 7 DIUS () inches 36.LEGND.us/cablofil

P CLE TY 45 orizontal 45 Elbo 30 orizontal 30 Elbo 2 45 C D 2 tangent 30 3" C D DIUS r IDT adius 2 r2 C D DIUS r IDT adius 2 r2 C D 6 18 17 7 /8 11 5 /8 31 1 /2 13 6 18 14 1 /2 9 1 /8 26 1 /4 7 9 21 20 14 5 /8 33 5 /8 13 7 /8 9 21 16 1 /8 1 /8 27 3 /4 7 3 /8 22 1 /8 17 5 /8 35 3 /4 14 3 /4 18 30 26 3 /8 23 5 /8 40 16 1 /2 17 5 /8 15 1 /8 29 1 /4 7 7 /8 18 30 20 5 /8 21 1 /8 32 1 /4 8 5 /8 36 30 5 /8 29 5 /8 44 1 /8 18 1 /4 30 42 34 7 /8 35 5 /8 48 3 /8 20 36 48 39 41 5 /8 52 5 /8 21 7 /8 6 30 26 3 /8 15 1 /8 48 3 /8 20 9 33 28 1 /2 18 1 /8 50 1 /2 21 36 30 5 /8 21 1 /8 52 5 /8 21 7 /8 18 42 34 7 /8 27 1 /8 56 7 /8 23 5 /8 36 23 5 /8 27 1 /8 35 1 /4 9 3 /8 30 42 26 5 /8 33 1 /8 38 1 /4 10 1 /4 36 48 29 5 /8 39 1 /8 41 1 /4 11 6 30 20 5 /8 10 3 /4 38 1 /4 10 1 /4 9 33 22 1 /8 13 3 /4 39 3 /4 10 5 /8 36 23 5 /8 16 3 /4 41 1 /4 11 18 42 26 5 /8 22 3 /4 44 1 /4 11 7 /8 48 39 33 1 /8 61 1 /8 25 3 /8 48 29 5 /8 28 3 /4 47 1 /4 5 /8 30 54 43 1 /4 39 1 /8 65 3 /8 27 1 /8 30 54 32 5 /8 34 3 /4 50 1 /4 13 1 /2 36 60 47 1 /2 45 1 /8 69 5 /8 28 7 /8 36 60 35 5 /8 40 3 /4 53 1 /4 14 1 /4 6 42 34 7 /8 18 5 /8 65 3 /8 27 1 /8 9 45 37 21 5 /8 67 1 /2 28 6 42 26 5 /8 3 /8 50 1 /4 13 1 /2 9 45 28 1 /8 15 3 /8 51 3 /4 13 7 /8 36 48 39 5 /8 69 5 /8 28 7 /8 18 54 43 1 /4 30 5 /8 73 7 /8 30 5 /8 36 48 29 5 /8 18 3 /8 53 1 /4 14 1 /4 18 54 32 5 /8 3 /8 56 1 /4 15 60 47 1 /2 36 5 /8 78 1 /8 32 3 /8 60 35 5 /8 30 3 /8 59 1 /4 15 7 /8 30 66 51 3 /4 42 5 /8 82 3 /8 34 1 /8 30 66 38 5 /8 36 3 /8 62 1 /4 16 5 /8 36 72 56 48 5 /8 86 5 /8 35 7 /8 36 72 41 5 /8 42 3 /8 65 1 /4 17 1 /2 itray horizontal elbo ctlog numbering example: ottom Type LD-4-90 -06 VENTED LD Ladder ung rail VC Vented Corrugated height fitting 4 4" non-vented DIUS 5 5" 90 SC Solid Corrugated 6 6" material 60 S Solid ottom 7 7" 45 30 idth itray fittings 13 For detailed material and finish descriptions, see page 6..LEGND.us/cablofil

P CLE TY S / L / orizontal educers T orizontal Standard Tee straight 1 L 2 left hand 1 L Length 18 IGT hand main 1 2 1 2 available branch s 2 9 6 - - - - - 6 9 - - - - 18 6 9 - - - 6 9 18 - - 30 6 9 18-36 6 9 18 30 L DIUS 36 idth 6 36 21 9 39 42 27 18 48 33 54 39 30 60 45 36 66 51 6 60 33 9 63 36 66 39 18 72 45 78 51 30 84 57 36 90 63 6 84 45 9 87 48 90 51 18 96 57 102 63 30 108 69 36 114 75 itray fittings 14 itray horizontal reducer ctlog numbering example: ottom Type LD-4 -S09-06 idth 2 VENTED rail IDT 1 LD Ladder ung height fitting VC Vented Corrugated 4 4" non-vented 5 5" S SC Solid Corrugated 6 6" material L S Solid ottom 7 7".LEGND.us/cablofil

P CLE TY T / ET orizontal educing/expanding Tees reducing tee 2 1 main 1 branch 2 DIUS DIUS DIUS 9 6 36 60 36 84 48 6 36 27 60 39 84 51 9 39 27 63 39 87 51 6 36 33 60 45 84 57 18 9 39 33 63 45 87 57 42 33 66 45 90 57 6 36 39 60 51 84 63 9 39 39 63 51 87 63 42 39 66 51 90 63 18 48 39 72 51 96 63 6 36 45 60 57 36 84 69 9 39 45 63 57 87 69 30 42 45 66 57 90 69 18 48 45 72 57 96 69 54 45 78 57 102 69 6 36 51 60 63 84 75 9 39 51 63 63 87 75 36 42 51 66 63 90 75 18 48 51 72 63 96 75 54 51 78 63 102 75 30 60 51 84 63 108 75 expanding tee 2 1 main 1 branch 2 DIUS DIUS DIUS 9 39 21 63 33 87 45 42 21 66 33 90 45 6 18 48 21 72 33 96 45 54 21 78 33 102 45 30 60 21 84 33 108 45 36 66 21 90 33 114 45 42 66 36 90 48 18 48 72 36 96 48 9 54 78 36 102 48 30 60 84 36 108 48 36 66 90 36 36 114 48 18 48 27 72 39 96 51 54 27 78 39 102 51 30 60 27 84 39 108 51 36 66 27 90 39 114 51 54 33 78 45 102 57 18 30 60 33 84 45 108 57 36 66 33 90 45 114 57 30 60 39 84 51 108 63 36 66 39 90 51 114 63 30 36 66 45 90 57 114 69 itray horizontal TEE ctlog numbering example: ottom Type LD-4 -T-06 VENTED rail IDT 1 LD Ladder ung VC Vented Corrugated height fitting 4 4" non-vented DIUS 5 5" ST* SC Solid Corrugated 6 6" material T S Solid ottom 7 7" ET * idth 2 does not apply to Standard Tee (ST). idth 2* itray fittings 15 For detailed material and finish descriptions, see page 6..LEGND.us/cablofil

P CLE TY YL / Y orizontal ye ranches X orizontal standard Cross Left hand C IGT hand idt DIUS C 6 27 3 /8 4 1 /2 27 7 /8 9 31 5 /8 7 1 /2 39 1 /8 35 7 /8 10 1 /2 46 3 /8 18 44 3 /8 16 1 /2 60 7 /8 52 7 /8 22 1 /2 75 3 /8 30 61 3 /8 28 1 /2 89 7 /8 36 69 7 /8 34 1 /2 104 3 /8 idth DIUS DIUS DIUS 6 36 60 84 9 39 63 87 42 66 90 18 48 72 36 96 54 78 102 30 60 84 108 36 66 90 114 X orizontal reducing Cross 2 1 main 1 branch 2 DIUS DIUS DIUS 9 6 36 39 60 63 84 87 6 36 42 60 66 84 90 9 39 42 63 66 87 90 6 36 48 60 72 84 96 18 9 39 48 63 72 87 96 42 48 66 72 90 96 6 36 54 60 78 84 102 9 39 54 63 78 87 102 42 54 66 78 90 102 18 48 54 72 78 96 102 6 36 60 60 84 36 84 108 9 39 60 63 84 87 108 30 42 60 66 84 90 108 18 48 60 72 84 96 108 54 60 78 84 102 108 6 36 66 60 90 84 114 9 39 66 63 90 87 114 36 42 66 66 90 90 114 18 48 66 72 90 96 114 54 66 78 90 102 114 30 60 66 84 90 108 114 itray fittings 16 itray horizontal reducing Cross ctlog numbering example: ottom Type LD-4 -X-0906 idth 2 VENTED rail IDT 1 LD Ladder ung VC Vented Corrugated height fitting 4 4" non-vented DIUS 5 5" X SC Solid Corrugated 6 6" material S Solid ottom 7 7".LEGND.us/cablofil

P CLE TY 90VO Vertical Outside 90º Elbo 60VO Vertical Outside 60º Elbo 90 60 DIUS idth rail height DIUS idth rail height 15 15 6-36 4-7 27 27 36 39 39 15 8 5 /8 6-36 4-7 25 1 /4 14 5 /8 36 35 5 /8 20 5 /8 45VO Vertical Outside 45º Elbo 30VO Vertical Outside 30º Elbo 45 30 DIUS idth rail height DIUS idth rail height 13 5 /8 5 5 /8 6-36 4-7 22 1 /8 9 1 /8 36 30 5 /8 5 /8 11 5 /8 3 1 /8 6-36 4-7 17 5 /8 4 3 /4 36 23 5 /8 6 3 /8 idths () inches 6 9 18 30 36 rail heights () inches 4 5 6 7 DIUS () inches 36 itray vertical INside elbo ctlog numbering example: ottom Type LD-6-90vo-06 VENTED LD Ladder ung rail VC Vented Corrugated height fitting DIUS 4 4" non-vented 5 5" 90vo SC Solid Corrugated 6 6" material 60VO S Solid ottom 7 7" 45vo 30vo idth itray fittings 17 For detailed material and finish descriptions, see page 6..LEGND.us/cablofil

P CLE TY 90VI Vertical Inside 90º Elbo 60VI Vertical Inside 60º Elbo 90VI 60VI 90 60 = 4 = 5 = 6 = 7 = 4 = 5 = 6 = 7 adius adius LL 19 19 20 20 21 21 22 22 31 31 32 32 33 33 34 34 36 43 43 44 44 45 45 46 46 LL 18 3 /8 10 5 /8 19 1 /4 11 1 /8 20 1 /8 11 5 /8 21 1 /8 28 3 /4 16 5 /8 29 5 /8 17 1 /8 30 1 /2 17 5 /8 31 3 /8 18 1 /8 36 39 1 /8 22 5 /8 40 23 1 /8 40 7 /8 23 5 /8 41 3 /4 1 /8 45VI Vertical Inside 45º Elbo 30VI Vertical Inside 30º Elbo 45VI 30VI 45 30 = 4 = 5 = 6 = 7 = 4 = 5 = 6 = 7 adius adius LL 16 3 /8 6 3 /4 17 1 /8 7 1 /8 17 7 /8 7 3 /8 18 1 /2 7 5 /8 7 /8 10 3 /8 25 5 /8 10 5 /8 26 3 /8 10 7 /8 27 11 1 /4 LL 13 5 /8 3 5 /8 14 1 /8 3 3 /4 14 5 /8 3 7 /8 15 1 /8 4 19 5 /8 5 1 /4 20 1 /8 5 3 /8 20 5 /8 5 1 /2 21 1 /8 5 5 /8 36 33 3 /8 13 7 /8 34 1 /8 14 1 /8 34 7 /8 14 3 /8 35 1 /2 14 3 /4 36 25 5 /8 6 7 /8 26 1 /8 7 26 5 /8 7 1 /8 27 1 /8 7 1 /4 itray fittings 18 idths () inches 6 9 18 30 36 rail heights () inches 4 5 6 7 DIUS () inches 36 itray vertical INside elbo ctlog numbering example: ottom Type LD-4-90Vi -09 VENTED LD Ladder ung rail VC Vented Corrugated height fitting DIUS 4 4" COdE non-vented 5 5" 90Vi SC Solid Corrugated 6 6" material 60Vi S Solid ottom 7 7" 45Vi 30Vi idth.legnd.us/cablofil

P CLE TY Td / TU Vertical Tees VX Vertical Cross TEE don TD VX tee up TU DIUS all rail height 4 58 5 59 6 60 7 61 DIUS all TEE UP fittings have rungs or bottom members for cable support across the bottom of the fitting. rail height 4 58 31 5 59 32 6 60 33 7 61 34 CS Vertical cable Support Elbo CS Supports cables at the top of long vertical drops here the eight of the vertical cable may be excessive. ooks (sold separately) attach to the brace in the elbo; hen used ith cable grips (supplied by others), tension in the vertical cable is relieved and transferred to the elbo. all rail height 4 DIUS DIUS DIUS 19 31 43 5 20 32 44 36 6 21 33 45 7 22 34 46 itray vertical TEE ctlog numbering example: ottom Type LD-4 -TU-09 VENTED LD Ladder ung rail VC Vented Corrugated height fitting 4 4" DIUS non-vented 5 5" TU SC Solid Corrugated 6 6" material TD S Solid ottom 7 7" idth itray fittings 19 For detailed material and finish descriptions, see page 6..LEGND.us/cablofil

P CLE TY SFF / lff / spf Covers solid flat flanged louvered FLT flanged solid peaked flanged material straight section cover ctlog numbering example: -lff-s060-06 cover type SFF Solid Flat Flanged lff Louvered Flat Flanged SPF Solid Peaked Flanged Length S060 60" S072 72" S0 0" S144 144 idth for horizontal elbos ( 90hb/60hb/45hb/30hb) 90 60 45 30 luminum for Ladder and Solid Flat ottoms C luminum for Corrugated ottoms orizontal Elbo cover ctlog numbering example: -Sff-90-06 cover type SFF Solid Flat Flanged lff Louvered Flat Flanged SPF Solid Peaked Flanged fitting 90 60 45 30 DIUS idth for vertical OUTside elbos ( 90VO/60vo/45v0/30vo) 90 60 45 30 vertical outside Elbo cover ctlog numbering example: material -S f f - 90vo-1 2-4 cover type SFF Solid Flat Flanged lff Louvered Flat Flanged SPF Solid Peaked Flanged fitting 90vo 60vo 45vo 30vo DIUS idth rail height 4 4" 5 5" 6 6" 7 7" itray covers for vertical inside elbos (90Vi /60vi /45vi /30vi) 90 60 45 30 vertical inside Elbo cover ctlog numbering example: material -Sff-90vi - cover type SFF Solid Flat Flanged lff Louvered Flat Flanged SPF Solid Peaked Flanged fitting 90vi 60vi 45vi 30vi DIUS idth 20.LEGND.us/cablofil

P CLE TY for horizontal TEE (T) and COSS (X) for horizontal educing TEE (T), Expanding TEE (ET) and educing Cross (X) 2 2 1 1 2 2 1 1 2 2 1 1 horizontal tee cover ctlog numbering example: material cover type SFF Solid Flat Flanged lff Louvered Flat Flanged SPF Solid Peaked Flanged horizontal educing Tee cover ctlog numbering example: material -Sff-T-06 cover type SFF Solid Flat Flanged lff Louvered Flat Flanged SPF Solid Peaked Flanged -Sff-T-06 fitting T X fitting T ET X DIUS DIUS * vailable branch s dependant on main selection. See tables belo. 1 idth 2* for horizontal straight reducer (S), Left hand educer (L) and ight hand reducer () 1 1 2 1 1 2 for horizontal Left hand YE (YL) and ight hand ye (Y) 2 2 2 1 2 1 horizontal straight reducer cover ctlog numbering example: material -Sff-S-06 cover type SFF Solid Flat Flanged lff Louvered Flat Flanged SPF Solid Peaked Flanged cover type SFF Solid Flat Flanged lff Louvered Flat Flanged SPF Solid Peaked Flanged fitting S L 1 * vailable reducing s dependant on main selection. See reducing table belo. 2* horizontal left hand ye cover ctlog numbering example: material -Sff-YL- fitting YL Y DIUS idth main s (1) available reducing branch s (2) 9 6 - - - - - 90 6 9 - - - - 60 18 6 9 - - - 45 6 9 18 - - 30 6 9 18-36 6 9 18 30 30 main s (1) available expanding branch s (2) 6 9 18 30 36 9 18 30 36-18 30 36 - - 18 30 36 - - - 30 36 - - - - 30 36 - - - - - FCC flat cover connector FCC GE S6 PCC PEKED cover connector PCC GE S6 itray Covers / Material idth Fasteners 4 - FCC -06-GE / Material idth Fasteners 4 - PCC -06-S6 21 90 60 45 30 For detailed material and finish descriptions, see page 6..LEGND.us/cablofil

P CLE TY SSP Straight splice kit FSP fitting splice kit SSP GE S6 / Material Fasteners 4 - SSP -S6 " length Designed for splicing Itray straight sections FSP GE S6 / Material Fasteners 4 - FSP -GE 6" length Designed for splicing Itray fittings USP universal splice kit USP universal blank splice kit USP GE S6 / Material Fasteners 4 - USP -GE Designed to transition to P C-channel and other I-beam systems USP GE S6 / Material fasteners 4 - USP -S6 Field drill for connection to trays from other manufacturers EXSP expansion splice kit VSP vertical hanger splice kit itray splices & connectors idths () inches 6 9 18 30 36 EXSP GE S6 / Material fasteners 4 - EXSP -S6 Install as required P.xx or NEM VE-2 (see p. 61) VSP GE S6 / Material fasteners 4 - VSP -GE For vertical tray support ith threaded rods rail heights () inches 22 4 5 6 7.LEGND.us/cablofil

P CLE TY 90SP 90 connector splice kit FFSP floor flange splice kit 90SP GE S6 FFSP GE S6 ail eight / Material Fasteners 4-90SP -GE ail eight / Material Fasteners 4 - FFSP -S6 Includes 8 splice bolts for connecting trays SP horizontal adjustable splice kit VSP vertical adjustable splice kit Field drill outer splices Includes splices and tray SP GE S6 ail eight / Material Fasteners 4 - SP -S6 VSP GE S6 / Material fasteners 4 - VSP -GE SSP straight reducer splice kit OSP offset reducer splice kit Each side is N/2. SSP GE S6 / Material N Fasteners 4 - SSP - 06-GE OSP GE S6 / Material N Fasteners 4 - OSP - 06 -S6 itray splices & connectors Ty IDT reduction (N) inches 3 6 9 15 18 21 27 23 For detailed material and finish descriptions, see page 6. For other s that fit Itray specifications, look for the Itray Compatible logo on pages 40 thru 57..LEGND.us/cablofil

P CLE TY SP reducing height splice kit Tc tray-to-box connector (frame type) SP GE S6 TC GE S6 1 / 2 / Material Fasteners 5 4 - SP -GE / Material N Fasteners 4 - TC - 06 -S6 1 2 options 5 4 - - 6 4 5-7 4 5 6 Includes one frame and Designed to support Itray at connection to electrical enclosures E blind end kit DO drop out kit E GE S6 / Material Fasteners 4 - E -06-S6 Includes one frame and DO GE S6 Material Fasteners - do -06-S6 Snaps in place over I-rung DIV Vertical elbo dividers CCLMP cable clamp Z itray accessories outside elbo inside elbo idths () inches 6 9 18 30 36 rail heights () inches 4 5 6 7 DIUS () inches 36 DIV S6 / Material elbo Fasteners 6 - DIV -90vo--S6 Each divider includes four self-drilling scres CCLMP catalog numbering ex: Cable Size CCLMP 21 Secures MC cable to Itray in vertical installations. One hand installation. Combination bolt/phillips head. Use maximum mm cable size hen specifying clamp. CLE SIZES INCES MM 0.25-0.84 6-21 0.85-1.35 22-35 1.25-1.75 32-45 1.55-2.05 40-52 2.00-2.50 51-64 2.50-3.00 64-76 3.25-3.75 83-95 3.75-4.25 95-108 reduction (N) inches 3 6 9 15 18 21 27.LEGND.us/cablofil

P CLE TY OCK outdoor conversion kit PS all penetration sleeve 20" M Loose collar slides over sleeve after it is placed in the all G Makes ladder tray all penetrations eather resistant to minimize ater intrusions. emovable cover/shield fastens to tray and all penetration sleeve for the utmost in eather protection. FPS FIe all penetration sleeve Fixed collar is elded to sleeve 20" *+6" side vie end vie OCK GE S6 / Material fasteners 4 - OCK -06-S6 UL *=Nominal classified Tray for idth use ith: *=Tray Side ail eight 2-hr concrete or block alls 2-hr concrete floors 1-hr gypsum alls 2-hr gypsum alls FPS GE S6 / Material fasteners 4G - FPS -06-S6 *+6" M Loose collar slides over sleeve after it is placed in the all Cable trays are attached to both ends of the sleeve using standard splice plate connectors 7/16" diameter holes for 3/8" hardare (not included) G ilti Fire locks Cables Fixed Collar all ssembly (Gypsum all Shon) djustablecollar all nchors (Not Included) Provides a rigid support for cable tray at all penetrations. Overall Cable trays are attached to both length of the sleeve ends is of 20". the sleeve using ill standard splice plate connectors fit alls up to 8" thick. onding jumpers are not required for use 7/16" diameter holes *+6" for 3/8" hardare ith all sleeves. To pairs (not included) of splice plates and fasteners *+6" are included for tray attachment. Penetration Sleeve *=Nominal Tray idth *=Tray Side ail eight PS GE S6 ilti Fire locks / Material fasteners Cables 4M - PS -06-S6 djustable Collar Fixed Collar Floor ssembly Masonry nchors (Not Included) Penetration Sleeve Fabricated cable tray fire stop sleeves from Legrand, combined ith ilti Firestop s, are an economical alternative to the high cost of fabricating protective fire all and floor penetration sleeves in the field. This firestop system provides a rigid support for cable tray in a UL classified system approved for fire all and floor penetrations. fter the sleeve is placed in the all or floor, the loose collar slides over it. ardare for the tray connection only is included. ardare required to mount sleeves to the all or floor is not included. The ilti Fire lock is a compressible fire stop brick, ell-suited for installations here frequent cable changes may be required. locks are easily cut to fit any space, and can be removed and reinstalled hen cable configurations change. hen exposed to fire, the blocks expand to lock the seal in place. Each cable tray firestop sleeve includes: One penetration sleeve ith flanges ilti Fire locks One ilti Firestop Putty Stick ardare for cable tray connection to the all sleeve Number of ilti Fire blocks included ith each sleeve SLEEVE Side rail eight (in.) 4 5 6 7 6 2 2 3 3 9 3 3 4 4 3 4 5 6 18 5 6 7 8 6 8 9 11 30 8 10 14 36 9 14 16 itray accessories 25 all ssembly (Gypsum all Shon) For detailed material and finish descriptions, see ilti Fire page locks 6. For other s that fit Itray specifications, look for the Itray Compatible logo on pages 40 thru 57..LEGND.us/cablofil