Closed Cup Flash Point Tester

Similar documents

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability


HIGH SPEED CENTRIFUGE

Instruments for Chemical and Petroleum Products. Flash Point

HIGH SPEED CENTRIFUGE


Instruments for the Analysis of Petroleum Products. Oxidation Stability

ADU 5. Automatic Distillation Unit

REFRIGERATED CENTRIFUGE. LRF-A2 Series

Penetration. Test Methods

Determination of flash point Pensky-Martens closed cup method

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Vertical Tensile Machine

TESTING OF FUELS : FLASH AND FIRE POINT


Refrigerated. Centrifuge.

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

SOUTH AFRICAN NATIONAL STANDARD

REFRIGERATED CENTRIFUGE. LRF-A1 Series

ElvaX Sulfur in Oil analyzer

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

Cetane ID 510. Customer Presentation. Refining. Petrochemical

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Callisto 100. Cold Filter Plugging Point Tester

L U B R I C A N T S & MATERIALS

On-Line NIR Analysis of Crude Distillation Unit

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

SPECTRO XRF Report. SPECTRO iq II

Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester 1

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

On-Line NIR Analysis for Blending

Innovation in cold behavior

Combustion Calorimeter System

Bomb Calorimeter System

Process Analyzer. Flash Point Analyzer Model P-500. Credible Solutions for the Oil and Gas Industry

Incubators. Incubators

Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester 1

Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester 1

DEPARTMENT OF CHEMICAL ENGINEERING University of Engineering & Technology, Lahore. Energy Engineering Lab

RSSOT New Standards ASTM D 7525 ASTM D 7545 ASTM D 7525 ASTM D Manufacturer since

ECscan20 Pocket Conductivity Tester Instruction Manual

Low cost EDXRF elemental analyzer

HAT220A ATS CONTROLLER USERS MANUAL

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines

Product Information. Mflow extrusion plastometer

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP

Standard Test Method for Flash Point by Tag Closed Cup Tester 1

InfraCal 2 Biodiesel Blend Analyzer

breakthrough versatility

Manual Kinematic Viscosity Bath Tamson TV12

MANUAL ELECTROMAGNETIC FIELD RADIATION TESTER EMF 823

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

ICAR-CIAE Bhopal, MP

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

RRI PERFORMANCE ASSESSMENT OF AFTERMARKET PERFORMANCE MODIFICATION 1 (12)

Product Profile. Laboratory instruments. for quality control, analysis and calibration. Fuels

Flash Point Process Analyzer

Torsion testing machine

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Exceeding Expectations

Mass Comparators Advanced Radwag solutions for traceability of measurement

Jet Fuel Conductivity Analysers & Additive Management systems

Standard Test Methods for Determining the Compatibility of Resin/Solvent Mixtures by Precipitation Temperature (Cloud Point) 1

Digital Copper Corrosion Measurement Vs. Visual Rating _ Incorporating New Technologies To Method Development

Standard Test Method for Freezing Point of Aviation Fuels (Automated Optical Method) 1

PHscan10S Pocket ph Tester Instruction Manual

Temperature multi-function calibrator Model CTM

Manual KREBS Viscometer PCE-RVI 5

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

Sulfur in Oil Analyzer

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

AVL CONTINUOUS FUEL BALANCE

EC20 Pocket Conductivity Tester Instruction Manual

TDSscan10M Pocket TDS Tester Instruction Manual

Maintenance. Scan this code with your smartphone and view the Battery regeneration instruction movie.

Gas analyzers EL3060 The specialists for hazardous areas

Salt 1 Pocket Salinity Tester Instruction Manual

TSHR 7000 series TN-TS-TX analyzer

GAS CHROMATOGRAPHY LGC-A1 SERIES

Mixer/Temperature Control

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

Standard Test Method for Cold Filter Plugging Point of Diesel and Heating Fuels 1

PCE-CS 300. Crane Scales up to 300 kg ( 661 lb)

SCOPE OF ACCREDITATION

Environmental Protection Agency

MAS, MAS.1 weighing modules

Rotor No.3, No.4, No.5 No.1, No.2, No.3 Cup A, B No.3 Cup Extension Rod - 1 PC Batteries 4pcs, IEC R6 4pcs, IEC R6

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

OPERATING INSTRUCTIONS. Models SI-1400 through SI-1406

END OF YEAR WAREHOUSE CLEARANCE SALE! Ex Demo & Superseded Instrumentation

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Solution Sheet 1.

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

EC1 Pocket Conductivity Tester Instruction Manual

Correlating TBP to Simulated Distillations. COQA Long Beach, CA

DigiTemp. Digital Thermometer

Transcription:

www.labtron.com info@labtron.com

We have distinguished ranges of Closed Cup Flash Point Tester especially designed to offer highest level of accuracy and quality giving a versatility in the capacity and its test method used. PMCC Flash Point Tester LCFP-A10 LCFP-A10 is compact, stand-alone closed cup flash point tester which determines the low temperature operability in diesel fuel, biodiesel, blends and gas oils. It is designed as per Test Methods for Flash Point of Petroleum Products (Pensky-Martens Closed Cup Methods) ASTM D93. Ignition source: Coal gas Rod type Mercury Thermometer Variable Temperature Range 45TYZ Stirring Motor It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 C. LCFP-A10 Temperature range Aperture of ignition device Standard oil cup Stirring speed Stirring blade Inner diameter Depth Depth of marked line on the oil cup Oil sample cubage 35 C 85% -5~110 C, Each scale division is 0.5 C; 20~150 C, Each scale division is 1.0 C; 90~370 C, Each scale division is 2 C 0.8mm 50.7~50.8mm 55.7~56.0mm 33.9~34.3mm About 70ml 90~120rpm for procedure A 250±10rpm for procedure B 8 40mm

Sample temperature rising rate Heating power Dimension Power 1~12 0 C per minute 0~600W 420*350*350mm 600W AC220V±10%, 50Hz Automatic PMCC Flash Point Tester LCFP-A11 Labtron model LCFP-A11 is an automated closed cup flash point tester with automatic control measurement procedures and test data. It is designed as per ASTM D93 Test Methods for Flash Point of Petroleum Products (Closed Cup Methods) Revised value calculation Measurement procedures and test data has programmed function Gas flame ignition mode Atmospheric pressure is modified automatically along with temperature control Measurement procedures and test data has automatic function Results are analyzed and saved automatically It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 C. 10~40 C 80% LCFP-A11 Measurement range Ambient Temperature~250 C Flash point Lower than 104 C, error is 2 C Higher than 104 C, error is 6 C Resolution Precision Gas flame Dimensions Total power consumption 0.1 C 0.5% 3~4mm 550*470*500mm 350W AC 220V±10%, 50Hz

Semi-auto PMCC Flash Point Tester LCFP-A12 Labtron LCFP-A12 is equipped with advanced software. It is suitable for flammability applications on both biodiesel and biodiesel-blended fuels along with distillate fuels like diesel, heating oil and kerosene. It is designed as per the National Standard GB/T261, ASTM D93 Test Methods for Flash Point of Petroleum Products (Closed Cup Methods). Microprocessor techniques Equipped with advanced software Temperature controller Print out test data automatically Six digits display It is used to determine the flash point of diesel and other fuel types in petrochemical analysis, flavors in food testing, paints in materials testing, and waste removal for environmental analysis Measurement range Temperature Accuracy measurement Resolution Stirring speed Gas flame Interval for flame application Repeatability Dimension Total power consumption Net weight LCFP-A12 +10 C ~+30 C < 80% ~250 C 0.2% 0.1 C 105rpm 4mm Flash point is lower than 104 C:1 C; Flash point is higher than 104 C:2 C Flash Point is lower than 104 C: error is 2 C; Flash Point is higher than 104 C: error is 4 C 360*110*300mm 300W 020V±10%, 50±1Hz 10kg

Automatic PMCC Flash Point Tester LCFP-A13 LCFP-A13 is designed with RS-323 and 485 computer ports which can calibrate the effect of barometric pressure to the test and calculate the modified value. It modifies system deviation automatically and can simulate and show temperature-time curve. It is designed as per the National Standard of People s Republic of China GB/T261 Test Methods for Flash Point of Petroleum Products (Closed Cup Methods) and ASTM D93. Predetermined temperature, sample serial number, atmospheric pressure, test data and other parameters Modifies test data, test time, and other parameters LCD display Electron igniter for flame ignition Effective wind cooling function It can save test data of 100 groups It is used to determine the flash point of diesel and other fuel types in petrochemical analysis, flavors in food testing, paints in materials testing, and waste removal for environmental analysis Measurement range Repeatability Reproducibility Resolution Accuracy Total power consumption LCFP-A13 10~40 0 C 8 0 C Room Temperature~300 0 C 2 0 C 4 0 C 0.1 0 C 0.5% 300W AC 220V±10%, 50Hz

Labtron Equipment Ltd Sentinel House, Ancells Business Park, Harvest Crescent, Fleet GU51 2UZ, United Kingdom Telephone: 01252 413773 www.labtron.com info@labtron.com