METAL DETECTOR AND REJECTION SYSTEM FOR MEAT EMULSION

Similar documents
METAL DETECTOR AND REJECTION SYSTEM FOR PIPELINE APPLICATIONS

METAL SEPARATOR QUICKTRON 03 R

Freefall metal detection system Vistus with separator FL

Freefall metal detection system Vistus with separator EC

Freefall metal detection system Vistus with separator ST 2.0

SIKA Flow Switches -1-

SIKA Flow Switches -1-

Reliable - Safe - Proven!

Standard cylinders DDPC, with measured-value transducer DADE

Solenoid valves VZWP, servo-controlled

Connections (*) Actuator Power MVX V ON/OFF MVX41 MVR24V MVR24MV (3) 24 V. Rev. h 07/10 1 DBL199E

Pressure Transmitters

Mounting and Operating Instructions EB 5868/5869 EN

VEP03MSV-PDRP CONTINENTAL HYDRAULICS 3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

WEIGH SYSTEM WS 1 kg M CD with Weighing Electronics Unit EWK 3010 / 3015 TS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Technical Details Coiler head / spool diameter Spool weight (depending on type of spool winding axle)

Turbine flowmeter HM-E / HMP-E

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

2-position electric actuators with Ball valves VBZ ½...11/4

VEP03MSV-PDRP -3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

WEIGH SYSTEM WS 2 / 5 / 7 kg M CD with Weighing Electronics Unit EWK 3010 / 3015 TS

AGILENT VACUUM VALVEs

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

Operating instructions Binary level sensor LMT /00 06/2011

Solenoid valves VZWM-L

MA-5200 Series MA-5300 Series

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

Type NAK. Gas-tight shut-off damper with pneumatic actuator

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100

SITRANS P measuring instruments for pressure

CPLab / CP Factory. Application module magazine. Data sheets

Operating instructions Binary level sensor. LI214x /00 04/2016

Magnetic-Inductive Flow Meter FMI

Factor 1) Modulating torque 4) [Nm]

Magnetic Inductive Flowmeter EP / UMF2 (B)

VER*SP CONTINENTAL HYDRAULICS PROPORTIONAL PILOT RELIEF VALVES VER*SP - PROPORTIONAL PILOT RELIEF VALVES

Metal tube variable area flowmeter for gases, liquids and steam

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

Continuous level sensor NSK

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

Broetje-Automation Company Standard Structural component specification for welded parts

GMP-Type. Key Features: Integrated Motor-Pump Units

600/700 SERIES FLANGED VALVES PENTAIR CLEAN AIR SYSTEMS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

1. TECHNICAL SPECIFICATIONS & OPERATION MANUAL

Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to Cv)

Valve attachment Gearbox Reduction ratio :1 5) : ,

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Typical Feed Water Heater Isolation System.

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Magnetic-Inductive flow Meter fmi

Quarter turn actuator DAPS..R..-F..

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

P U L S A R point 210

Pressure transmitter COMPACT ECOnomic

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting.

Factor 1) Modulating torque 4) [Nm] 200 F14 G1/2 GK : :

standards based cylinder DNCI Operating instructions e [ ]

Worcester 18/19 Series. Modular Multi-Way Ball Valves

MTF-E. Technical features

BM-01. Electrically operated valves 3/2-way G 1/8, Nl/min ( Cv) Technical data for series. Order code BM HNR-162

KE-M02 configuration Configuratie documentatie documentation KE-M02

MPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Solenoid valves VZWM-L, NPT

Thermowell For sanitary applications Model TW22

Connections (*) Rev. f 04/08 1 DBL199E

BM-02. Electrically operated valves 3/2-way G 1/4, Nl/min ( Cv) Technical data for series. Order code BM HNR-162

Pressure Sensors. for liquid and gaseous media

OPTISWITCH 6500 C Technical Datasheet

Solenoid coils VACF Type codes

Solenoid Valve DF-SA-series

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA

AKM 105, 115: Rotary actuator for ball valve

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES

INTEGRATED HYDRAULIC BRAKE ACTUATORS

Peristaltic Cased Tube Pumps

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

VARIABLE SPEED WATER BOOSTER SETS WITH MULTISTAGE VERTICAL ELECTRIC PUMPS FLOW RATES UP TO 400 m 3 /h. 50 Hz GHV30 GHV40 SERIES

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

SCHMIDT PneumaticPress

SCHMIDT PneumaticPress

The New Filter Valve Technology

MTF. Technical features

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

System 13. ü ( System 13

Electromotoric actuators

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

AN ISO 9001 COMPANY. Barrel Pump BP Operation & Maintenance Guide FF - MM - 01 REV - 0. Sheet 1 of 5

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

Solenoid System FLANGE MOUNTING VERSION

Transcription:

DEVICE DESCRIPTION This metal detector and rejection system has been specially developed for the high detection and hygiene requirements needed in the examination of meat emulsion. Versions are available which can be connected to the current Handtmann and Vemag fillers. The type MDP Plus-R search coil with evaluation electronics MDP Plus-E is used as the metal detection device (see the corresponding data sheets). The search coil can optionally be enclosed in a stainless steel housing (fully encased design) or can be freely accessible (non-encased design). The product guide pipe can be removed laterally following the loosening of an eccentric clamping level (fully encased design) or two hand knobs (non-encased design). The rejection device (slide valve ASV) has a pneumatically operated piston which allows the product to flow horizontally. When there is a metal signal, the piston is moved upwards and the product flow in which there is metal contamination is diverted downwards. The slide valve can be dismantled without tools for periodic cleaning. The product guide connections are available in versions for connection to the current Handtmann and Vemag fillers. The entire system is assembled on a mobile stand construction. Fully encased design Non-encased design GATE Search coils of type MDP Plus-R 8.4 or MDP Plus-R 12 are used depending on the nominal width (NW) of the pipes: Search coil NW 50 NW 55 NW 65 MDP Plus-R 8.4 MDP Plus-R 12 OPERATING SENSITIVITY In addition to magnetic metal particles, high-alloy steels and non-ferrous metals (copper, brass, aluminum, lead, etc.) are also detected. The operating sensitivity of products with a high product effect (all moist, conductive products) is greatly dependent on the product characteristics such as temperature, moisture, salt content, type of conveyance, lumpiness of product additives etc. 1

OUTPUT Different outputs Q [m 3 /n] can be achieved depending on the speed of conveyance v [m/s] and the nominal width of the guide pipe. NW 50 NW 55 NW 65 v max [m/s] 0,5 0,5 0,4 Q [m 3 /n] 3,5 4,0 5,0 Note: Higher conveyance speeds can be achieved in special designs on request. PRODUCT GUIDE PIPE The standard version of a non-conductive product guide pipe is a POLYACETAL pipe with filler-specific connection fittings. SYSTEM PRESSURE FOR POLYACETAL PIPES The maximum permitted system pressure depends on the product and cleaning medium temperature and the nominal width. Temperature Search coil NW 50 NW 55 NW 65 0-20 C MDP Plus-R 8.4 50 bar 40 bar 20 bar 45 C MDP Plus-R 8.4 40 bar 32 bar 16 bar 85 C MDP Plus-R 8.4 25 bar 20 bar 10 bar Note: Short-term peak pressures may exceed the permitted permanent operating pressure by 100%. FLANGES According to customer requirements, various flanges are available both for the product guide pipe and for the rejection device (for information on this see also flange dimensional drawing). Image Flange type (material 1.4301) 1 Vemag HP 2 Handtmann VF quick opening device/vemag DP 3 Handtmann VF with nipple 4 Vemag HP, screw joint DIN 11887 / 11851 (milk pipe) 5 Tri clamp ISO 2852 6 Handtmann ball - Weld-on end 2

REJECTION DEVICE (optional) It is recommended that the slide valve (ASV) is used as the rejection device. This is well suited for the following requirements. Filler-specific connection fittings are available. Homogenous liquid and viscous mass Liquid and viscous mass with soft solids 2 mm Liquid and viscous mass with soft, fibrous and hard solids 15 mm Cavity free (almost) Slide valve (ASV) Available diameter [mm] 50, 65 The complete exchange of remaining product in the rejection path is achieved by rejection that must be carried out periodically. The rejection device is operated pneumatically. The operating pressure that is available must be 6 bar. STAND CONSTRUCTION The stand construction is produced entirely from blasted stainless steel. The use of lockable guide rollers means that it is easy to move the entire system to where it is needed. The inclination of the device can be adjusted to the on-site conditions using a clampable hinge. CE MARKING Declaration of conformity according to the EMC Directive (2004/108/EC). Declaration of conformity according to the Low Voltage Directive (2006/95/EC). Manufacturer's declaration according to the Machinery Directive (98/37/EC). GENERAL TECHNICAL DATA Voltage Power consumption Ambient temperature Inlet height Weight Protection class 115 V or 230 V -15/+10%; 50/60 Hz ± 2 Hz approx. 100 VA - 10 C... + 40 C 500... 1130 mm (fully encased design), or 500... 1080 mm (non-encased design), adjustable via the clampable hinge of the stand. approx. 40... 90 kg (depending on the nominal width and rejection device type) IP 65 (evaluation electronics, search coil and rejection device) 3

Flange dimensional drawing 1 2 Vem. HP Vem. HP Vem. DP / Hm. VF Vem. DP / Hm. VF quick 3 4 Hm. VF Hm. VF Milk pipe Vem. HP 5 6 Clamp Clamp Hm. KU Hm. KU No. Flange type (material 1.4301) A B 1 Vemag HP (Vem. HP) 501 244 2 Handtmann VF (Hm. VF) / Vemag DP (Vem. DP) 493.5 281 3 Handtmann VF (Hm. VF) with nipple 479 281 4 Vemag HP (Vem. HP), screw joint DIN 11887 / 11851 (milk pipe) 501 240 5 Tri clamp ISO 2852 450 203 6 Handtmann ball (Hm. KU) 496 230 For dimensions A and B refer to dimensional drawing on the next page 4

DIMENSIONAL DRAWING Fully encased design with rejection device: slide valve ASV Non-encased design with rejection device: slide valve ASV 5