Installation, Operating & Maintenance Instructions

Similar documents
CAUTION! This manual contains important information for the correct installation, operation and maintenance of the equipment described herein.

Installation, Operating and Maintenance Instructions. Rotating Machine Screw Actuators. With Parts List Publication Part No.

Publication Part No. SK

Mechanical Actuators

Operation and Maintenance Manual for. Joyce/Dayton Linear Actuator Pound Capacity DC Actuator, LA152L, and LA152C

Operation and Maintenance Manual for. Joyce/Dayton Linear Actuator Pound Capacity AC Actuator (with limit switch and potentiometer)

ELECTROMECHANICAL LINEAR ACTUATOR. Your First Choice In Motion Technology CMLA SERIES

Operation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator

ANDCO Eagle Actuator Instruction Manual

SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)

ELECTROMECHANICAL LINEAR ACTUATOR DESIGN GUIDE

Potentiometer Thrust Plate Kit (50421) Installation & Operator s Instruction Manual

ASSEMBLY OF TROLLEY TO HOIST

Operation and Maintenance Manual for Joyce Dayton. Integrated Actuator- Acme Screw. Maximum capacity: 2000-pounds

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

The gear boxes can be run at the same speeds as the actuator models. Do not exceed torque ratings.

Max IV Rear Axle Replacement For models after Serial Number and all rear splined axle replacements.

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Tooling Assistance Center

EASYBIRD OSCILLATING BASE 12VDC Part No

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

Effective June 2016 New Issue

Operation and Maintenance Manual. ACME SCREW Electric Cylinders by Joyce Dayton. Standard, Motor mount, and ComDRIVE style

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

Electric Actuator Installation, Operation & Maintenance Manual

FPO See DN-SCCAT_COVER-SPINE.indd

DRIVE AXLE Volvo 960 DESCRIPTION & OPERATION AXLE IDENTIFICATION DRIVE AXLES Volvo Differentials & Axle Shafts

DRIVE AXLE - INTEGRAL HOUSING

Single Post Caliper Brake VC500

Quarter Master Series 94 Actuator

The most comprehensive linear actuator available on the market today

The Da-Lite Difference.

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Read this entire manual before operation begins.

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Quarter Master Chief Series 92 Actuator

McCANNA Actuation Systems B

Model QED-D, QED-A, QED-L

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

Read this entire manual before operation begins.

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

Read this entire manual before operation begins.

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

Operation and Maintenance Manual. Joyce/Dayton Electric Cylinders with Ball Screw. Standard, Motor mount, and ComDRIVE style

Read this entire manual before operation begins.

Valtek Auxiliary Handwheels and Limit Stops

I N S TA L L AT I O N G U I D E

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

FLEXIDYNE PH Couplings

LOR Series Trig-O-Matic Lite Overload Release Clutch

YALE MOTOR DRIVEN TROLLEYS. For 1/2 thru 15 ton YALE Wire Rope Electric Hoists

STEERING SYSTEM - MANUAL RACK & PINION

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

Pro-Series/ Electromechanical Linear Actuator

Installation Instructions

Effective November 2016 Supersedes February 2012 (S )

Linear Actuators P-6150-WL

Quick Connection Cabinet (QCC)

INSTRUCTION MANUAL. Series PROCUNIER SAFETY CHUCK CO. (Serial Nos. B4870 and higher. (Serial Nos. B9230 and higher

LINEAR ACTUATORS. Ph: (800) Fax: (704) PDF:

Sachs 48mm Closed Cartridge fork Service Manual

CRD610 Automatic Fitting Inserter

03561 SPEED BOOSTER INSTRUCTION MANUAL. for the Ultra Tugger

Read this entire manual before operation begins.

Operating and Maintenance Instructions

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

60 Series End-Mount Brake Instructions Standard Housing

The Da-Lite Difference.

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Atlas PV-9WP Addendum

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

HFB Steering Gear Service Manual

Surepowr Series 100 Installation Manual

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Maintenance Information

The Da-Lite Difference.

Pump Installation and Service Manual HRS Hydromatic Retractable System

Operation and Maintenance Manual

MOTION TECHNOLOGIES PTY LIMITED

Operating and Maintenance Instructions

SPC-PANEL Simplex, Single Phase Pump Control Panel

WARNING. Electric Recovery Winch. General Safety Precautions

Maintenance Information

Instruction Manual for FLEXIDYNE Couplings Sizes 9C and 11C

Manual E1195 (MCP) Series 2000

Raydot LLC 24 Actuator (115 VOLT)

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

16K and 19K Sidewinder TM Service Kit Instructions 86005

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

Read this entire manual before operation begins.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

LINEAR ACTUATOR. MODULAR ACTUATORS 100 to 2000 lbs (444 to 8896 N) OPTIONS WARNING

ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator

Transcription:

Electromechanical Linear Actuators Installation, Operating & Maintenance Instructions with parts list TAC Models with Clutch TAL Models with Limit Switches TAC Models with Limit Switches and Potentiometer Publication Part No. EM-1050-200 Electromechanical Actuators with Acme Screw CAUTION This manual contains important information for the correct installation, operation and maintenance of the equipment described herein. All persons involved in such installation, operation, and maintenance should be thoroughly familiar with the contents. To safeguard against the possibility of personal injury or property damage, follow the recommendations and instructions of this manual and keep it for further reference. WARNING The equipment shown in this manual is intended for industrial use only and should not be used to lift, support, or otherwise transport people.

Section I General Information Contents 1-1. General Information...3 1-2. Application Information...3 1-3. Inspection...3 Figure 3-1. Dimensions in Inches...3 1-4. Warranty and Warranty Repair...3 Table 1-1. TA500 Performance at Rated Load...4 Table 1-2. TA1000 Performance at Rated Load...4 Section II Installation 2-1. Clevis Connections...4 2-2. Motor Capacitor...4 2-3. Wiring Connections...4 Figure 2-1. Wiring Schematic...4 Figure 2-2. Terminal Block Connections (AC)...5 Figure 2-3. Wiring Schematic DC with Clutch...5 2-4. Limit Switch Adjustment...5 2-5. Potentiometer Adjustment...5 Section III Operation Precautions 3-1. Motor...6 3-2. Clevis Pins...6 3-3. Jamming...6 Section IV Maintenance 4-1. Lubrication...7 4-2. Disassembly...7 4-3. Load Bearing...7 4-4. Reassembly...7 Section V Parts Lists and Technical Illustrations Table 5-1. Linear Actuator Parts List...8 Figure 5-1. Linear Actuator Exploded Illustration...9 Table 5-2. Limit Switch Parts List...10 Figure 5-2. Limit Switch Exploded Illustration...11 2

Section I General Information 1-1. General Information This manual provides information for the installation, operation and repair of Duff-Norton electromechanical actuators. 1-2. Application Information The actuators described in this manual are intended for industrial use only and should not be used to lift, support or otherwise transport people or loads over people, unless you have obtained written authorization from Duff-Norton that the actuator is suitable for the particular application. The actuator is designed for lifting or pushing loads no more than its load rating, on an intermittent basis, not for applications requiring continuous operation. The actuator is designed for clevis mounting and cannot support side loading of the translating tube. 1-3. Inspection Every actuator is tested at the factory under full rated load to ensure that the actuator operates properly and that limit switches precisely stop its travel. Limit switch settings must be rechecked at installation, since rotation of the translating tube will change set points. Inspect the actuator before installation for any evidence of shipping damage or loose parts. 1-4. Warranty and Warranty Repair Subject to the conditions stated herein, Duff-Norton will repair or replace, without charge, any parts proven to Duff-Norton s satisfaction to have been defective in material or workmanship. Claims must be made within one year after date of shipment. Duff-Norton will not repair or replace any parts that become inoperative because of improper maintenance, eccentric loading, overloading, chemical or abrasive action, excessive heat, or other abuse. Equipment and accessories not of Duff-Norton s manufacture are warranted only to the extent they are warranted by the manufacturer, and only if the claimed defect arose during normal use, applications, and service. Equipment which has been altered or modified by anyone without Duff-Norton s authorization is not warranted by Duff-Norton. Except as stated herein, Duff-Norton makes no other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Authorization for return must be received from Duff-Norton before returning any equipment for inspection or warranty repair. Table 3-1. Dimensions in Inches 3

Table 1-1. TA500 Performance at Rated Load Available Models Clutch Limit Switch Potentiometer Voltage Speed Amps Duty TAL05-1A10-# X 115Vac, 60Hz 52 in/min 4.0 amps 17.5% TAP05-1A10-# X X TAL05-2A10-# X 230Vac, 60 Hz 54 in/min 2.0 amps 17% TAP05-2A10-# X X [220Vac, 50 Hz] [45 in/min] [2.5 amps] [14%] TAC05-1D20-# X 12 Vdc 27 in/min 10 amps 40% TAC05-2D20-# X 24 Vdc 27 in/min 5 amps 40% Table 1-2. TA1000 Performance at Rated Load Available Models Limit Switch Potentiometer Voltage Speed Amps Duty TAL10-1A20-# X 115Vac, 60Hz 26 in/min 4.0 amps 17.5% TAP10-1A20-# X TAL10-2A20-# TAP10-2A20-# X X X 230Vac, 60 Hz (220Vac, 50 Hz) 27 in/min (22 in/min) 2.0 amps (2.5 amps) # = Actuator stroke. Standard strokes are 4, 8 and 12 inches (101, 203 and 305 mm) Custom stroke lengths are available. Performance figures at rated load. Data is approximate. 17% (14%) 2-1. Clevis Connections Refer to Fig. 1-1 for appropriate mounting dimensions. The actuator should be connected with.50 inch diameter steel clevis pins, or bolts with enough unthreaded length to provide full clevis support. Lightly grease clevis pins to prevent wear and noise. 2-2. Motor Capacitor All AC units use permanent split capacitor motors requiring an external motor run capacitor. Capacitor ratings are listed below. Voltage Rating Duff-Norton No. 115VAC 50uf,370VAC SK6405-7-15 230VAC 15uf,440VAC SK6405-7-14 If actuators are never operated at more than 50% of rated load, capacitance may be reduced by up to 33%, resulting in lower current and motor operating temperature. 2-3. Wiring Connections All wiring connections for AC units can be made to the Section II Installation terminal block under the motor cover. Refer to Fig. 2-1 for wiring schematic and Fig. 2-2 for Terminal Block Connections. Connections to DC units are made directly to motor leads. Use wire adequate for the rated motor amps. Retract Extend White Black Cap Red Figure 2-1. Wiring Schematic Connect AC neutral to Common and switched motor power to Extend and Retract. Capacitor may be connected without regard to polarity. Connecting cable may be run through the grommet supplied, or a 1/2" size conduit fitting may be connected to the cover. If using fitting, check for clearance between fitting and installed cover. 4

Figure 2-2. Terminal Block Connections (AC) Motor Figure 2-3. Wiring Schematic DC with Clutch DC models with clutch may be operated through relays or by utilizing a momentary action, Double Pole, Double Throw, Center-off toggle switch (Duff-Norton part EM534). If actuator runs opposite the desired direction, reverse the red and black motor wires. 2-4. Limit Switch Adjustment 1. With translating tube unrestrained, run the actuator toward the retracted position until the switch cam actuates the switch. 2. Rotate the translating tube by hand to the desired retracted position. 3. With the translating tube restrained against rotation, run the actuator to the desired extended position. DANGER To avoid electric shock hazard and possible electrocution, disconnect power before making any adjustments inside motor cover. 4. Disconnect power. Remove motor cover. On Potentiometer models only: remove two screws holding the terminal block plate and pull plate and 5 potentiometer straight off, firmly holding limit switch cams. 5. Raise the flap of the electrical insulator sheet to expose the limit switch cams. Holding the cam gear to prevent loading of the small gears, loosen the two screws holding the top cam. Rotate the cam toward the switch until the switch just clicks. Again holding the gear, tighten the screws. 6. Restore power and operate actuator to check limit switch settings. 7. If settings are correct, disconnect power and reinstall motor cover. NOTE 1. Exercise care to avoid jamming the actuator. 2. With no load, some actuator drift is typical. If precise setting is required, it must be done with the expected operating load. 3. If problems are encountered setting the Retract switch, check to see if motor is turning while the translating tube is being twisted. If so, use a small screwdriver to hold the end of the motor shaft while twisting translating tube. 4. Rotating the translating tube will change the settings of both switches by 1/6 inch per revolution of the tube. 2-5. Potentiometer Adjustment 1. Actuator limit switches must be set prior to potentiometer installation. 2. The potentiometer is 5000 ohm single turn. Resistance changes approximately 235 ohms per inch for a 20:1 ratio actuator, or 117 ohms per inch for a 10:1 ratio. 3. Retract the actuator until the limit switch cuts it off. Disconnect power. 4. Loosen 1/2" nut on potentiometer bushing. Press potentiometer shaft into upper limit switch cam and mount terminal block plate with two screws and standoffs. 5. Use an ohmmeter to measure resistance between potentiometer terminals S and CW. Twist potentiometer body to minimize resistance between these terminals. Use a thin 1/2" end wrench to tighten pot nut. Recheck for continuity between S and CW. 6. Terminal S is the potentiometer slider, with actuator extension increasing the resistance between S and CW.

Section III Operation Precautions 3-1. Motor The motor used on this actuator has a very high power output for its size. Consequently, heat generation in the motor is more rapid than in more conventional motors. Duty cycle limitations must be recognized at all times, whether or not the actuator is loaded. Motors are equipped with thermal protectors to guard against winding burnout. Once tripped, it may take 10 15 minutes for the motor to cool sufficiently to reset the thermal protector. Repeated thermal trips can be an indicator of excessive load or duty, low voltage, or weak capacitor(ac only). warning When operated near duty limits, external motor temperature may be hot enough to cause burns. Actuator should be installed with appropriate precautions to prevent injury to personnel. 3-2. Clevis Pins The clevis pins must be maintained parallel to each other during the full stroke of the actuator. Side loading or torquing as a result of non-parallel clevises can cause serious actuator damage. Any creaking noise at the clevises is an indication that pins need lubrication to prevent pin wear. 3-3. Jamming caution Actuators with limit switches have no inherent mechanical overload protection. Repeated jamming of the actuator, internally or against an external stop, will result in very rapid wear and eventual failure. Be sure that limit switches are functioning properly to stop the actuator within its stroke limits. No-load operation will produce additional drift. Limit switches should be set far enough from ends of stroke to accommodate this if no-load operation is anticipated. Actuators with clutches have a degree of protection against internal or external jamming or overloading; however, extended slipping of the clutch will cause accelerated wear and premature actuator failure. To provide acceptable long-term operation at rated load, clutches are set somewhat above rated load. Do not depend on the clutch to gage an acceptable load. Clutches are not adjustable for wear. 6

Section IV Maintenance 4-1. Lubrication The load bearing and the screw and translating tube are adequately lubricated for the life of the unit. Gearing receives a light brush coat of grease at the factory. If the actuator is removed for repair or inspection, the gear lubricant may be replenished by filling the gear tooth spaces with a heavy, tacky gear grease. A few drops of oil should be placed on the porous bronze bearings at the same time. 4-2. Disassembly Remove the one Phillips head screw from the gear housing and the four hex head screws from the tube flange. Separate housing and housing plate. All mechanical parts should now be accessible. The lifting nut is threaded and staked to the translating tube. Disasssembly of the screw and translating tube assembly is not possible nor anticipated to be necessary, due to the expected long life of the screw and lifting nut. 4-3. Load Bearing The bearing is permanently lubricated and not readily relubricated. A bearing which shows any sign of roughness should be replaced. Clamp screw in a vise with soft jaws and remove retaining nut. Use thread locking adhesive on nut when replacing bearing. 4-4. Reassembly Assembly is the opposite of disassembly, with no special techniques required. Tube flange screws are selftapping style and should be started by hand to avoid possible cross-threading. 7

Index Number Section V Illustrated Parts List Table 5-1. Linear Actuator Parts List Part Name 8 Qty. Req. 1 Gear housing 1 EM1050-2 Part Number 2 Shaft, cluster gear 1 SK3410-43 3 Pinion 1 SK3410-7 4 Screw, 10-32 x 3/4 3 H2695PC 5 Housing plate 1 EM1050-1 6 O-ring, -142 1 X6477-137 7 Motor, 115 VAC 1 EM1050-24 7a Motor, 220-230 VAC 1 EM1050-25 7b Motor, 12 VDC 1 EM1050-26 7c Motor, 24 VDC 1 EM1050-27 8 Lifting nut 1 EM1050-33 9 O-ring 1 X6477-136 10 Spiral ring 1 S61-2C 11 Outer tube, 4" stroke 1 EM1050-6-4 Outer tube, 8" stroke 1 EM1050-6-8 Outer tube, 12" stroke 1 EM1050-6-12 12 Flange, tube 1 EM1050-3 13 Translating tube, 4" stroke 1 EM1050-5-4 Translating tube, 8" stroke 1 EM1050-5-8 Translating tube, 12" stroke 1 EM1050-5-12 14 Rod seal 1 EM1050-54 15 Clevis nut 1 SK3410-33 16 O-ring, -022 1 X6477-101 17 Top clevis 1 EM1050-7 18 Flanged bushing 1 SK3410-44 19 Cluster gear, 20:1 1 EM1050-36 Cluster gear, 10:1 1 SK3410-5 20 Output gear, limit switch models 1 EM1050-45 Clutch, 500 pound models 1 EM1050-58 21 Gasket, housing 1 SK3410-25 22 Nut, 1/2-20 1 S12-38C 23 Woodruff key, #304 1 S23-4C 24 Bearing, 6302Z 1 EM1050-302 25 Screw, 4" stroke 1 EM1050-4-4 Screw, 8" stroke 1 EM1050-4-8 Screw, 12" stroke 1 EM1050-4-12 26 Stop washer 1 EM1050-35 27 Screw, 3/8-24 x 3/4 1 H2413C 28 Screw, 12-24 x 2 4 H2696PC

WARNING Use only replacement parts supplied by or approved by Duff-Norton. Non-authorized parts may be inadequate, resulting in serious injury or death in event of failure. Figure 5-1. Linear Actuator Exploded Illustration 9

Index Number Table 5-1. Limit Switch Parts List Part Name Qty. Req. Part Number 1 Gasket 1 EM1050-65 2 Limit switch base 1 EM1050-72 3 Grooved pin, 1/16" 2 S57-10C 4 Cluster gear 4 SK3275-20 5 Standoff 2 EM1050-59 6 Gasket, cover 1 EM1050-66 7 Cam, upper 1 SK3275-21 8 Plate, terminal block 1 EM1050-61 9 Screw, #6 x 1.5 2 H2706PC 10 Terminal block 1 EM1050-60 11 Screw, 8-32 x 1-1/4" 2 S62-4C 12 Cover 1 EM1050-68 13 Screw, 8-32 x 3/8 2 S62-2C 14 Cam gear 1 SK3275-19 15 Grooved pin, 7/64" 2 S57-12C 16 Switch 2 SK3275-31 17 Cam, lower 1 SK3275-22 18 Pin, 1/8" 1 S51-4C 19 Retainer, 7/64" 2 SK3275-28 20 Screw, #8 x 5/8 2 H2926C 21 Retainer, 1/8" 1 SK3275-37 22 Grommet 1 EM1050-67 10

22 12 11 6 10 9 8 21 5 20 19 7 18 16 4 17 WARNING Use only replacement parts supplied by or approved by Duff-Norton. Non-authorized parts may be inadequate, resulting in serious injury or death in event of failure. 3 2 1 15 14 13 Figure 5-2. Limit Switch Exploded Illustration 11

Duff-Norton also Manufactures Mechanical Actuators Electromagnetic Actuators Rotary Unions Mechanical Jacks Duff-Norton P.O. Box 7010 Charlotte, NC 28241-7010 Phone: (800) 477-5002 (704) 588-4610 Fax: (704) 588-1994 Email: duffnorton@cmworks.com www.duffnorton.com ISO 9001 10000677 2017 Yale Industrial Products, Inc., Duff-Norton Division All rights reserved by Yale Industrial Products, Inc., Duff-Norton Division. May not be copied in whole or in part. Printed in the USA EM-1050-200 02/17