nti-vibration Gland ssembly Pressures to 20,000 psi (1379 bar) Sizes to 1-1/2 (38.10 mm) For extreme conditions of vibration and/or shock in tubing systems, such as an uned line near a compressor, conedand-threaded connections are offered with the Parker utoclave collet gland assembly. Completely interchangeable with standard Parker utoclave Engineers medium pressure connections, the collet gland assembly provides equally effective pressure handling capability. grips tubing Slotted ody In standard connection systems, the bending stresses on the threaded area of the tubing imposed by excessive vibration or movement may cause premature fatigue failure of the tubing at the back of the thread. y moving the stress concentration back to the unthreaded part of the tubing and providing a wedge-type gripping action, the Parker utocalve Engineers collet gland assembly strengthens the entire structure. With stress concentration reduced and overall stress level maintained well below the endurance limit of the material, the result is virtually unlimited vibrational fatigue life. less complex and more economical design than other vibration-resistant connections, the collet gland assembly utilizes the same coned-and-threaded features of Parker utoclave Engineers medium pressure connections. extends the gland nut to provide room for the tapered slotted collet. The design provides a slight difference in angles between the collet and the corresponding taper of the gland nut. s the nut is tightened, it acts to wedge the tapered end of the collet into a gripping engagement with the tubing. Pressures to 20,000 (1379 bar) Type 316 stainless steel with bonded dry film (316 MC) moly lubricant. Note: 1) To order components with assemblies add -K Outside Diameter Tubing Size KCGLX40-316MC KCLX40-316MC 1/4 0.94 1.19 0.62 KCCLX40-316MC (6.35) (23.88) (30.23) (15) KGLX40-316MC KCGLX60-316MC KCLX60-316MC 3/8 1.19 1.50 0.81 KCCLX60-316MC (9.53) (30.23) (38.10) (20.63) KGLX60-316MC KCGLX90-316MC KCLX90-316MC 9/16 1.41 1.78 0.94 KCCLX90-316MC (14.29) (35.81) (45.21) (23.88) KGLX90-316MC KCGLX120-316MC KCLX120-316MC 3/4 1.59 2.00 1.25 KCCLX120-316MC (40.37) (50.80) (31) KGLX120-316MC KCGLX160-316MC KCLX160-316MC 1 1.69 2.38 1.50 KCCLX160-316MC (25.40) (42.93) (60.45) (38.10) KGLX160-316MC KCGLX240-316MC KCLX240-316MC 1-1/2 2 3.63 2.25 KCCLX240-316MC (38.10) (69.85) (92.20) (57.15) KGLX240-316MC 20,000 psi ( 1379 bar) Standard Parker utoclave Engineers collar not included in complete assembly ll dimensions for reference only and subject to change. For prompt service, Parker utoclave Engineers stocks select products. Consult your local representative. ll general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
High nti-vibration Gland ssembly Pressures to 150,000 psi (10342 bar) Sizes to 9/16 (14.29 mm) For extreme conditions of vibration and/or shock in tubing systems, such as locating valve or fitting on an uned line near a compressor, Parker utoclave Engineers coned-and-threaded connections are offered with the nti-vibration Gland ssemblies. Completely interchangeable with standard Parker utoclave Engineers high pressure connections, the Gland ssemblies provide equally effective pressure handling capability. In standard connection systems, the bending stresses on the threaded area of the tubing imposed by excessive vibration or movement may cause premature fatigue failure of the tubing at the back of the thread. y moving the stress concentration back to the unthreaded part of the tubing and providing a wedge-type gripping action, the Parker utoclave Engineers collet gland assembly strengthens the entire structure. With stress concentration reduced and overall stress level maintained well below the endurance limit of the material, the result is virtually unlimited vibrational fatigue life. less complex and more economical design than other vibration-resistant connections, the Gland ssembly utilizes the same coned-and-threaded features of Parker utoclave Engineers high pressure connections. In Series KCGL the gland nut is recessed to accommodate a tapered, slotted collet that grips the tubing at a point behind the threaded area of the tubing.the design provides a slight difference in angles between the collet and the corresponding taper of the gland nut. s the nut is tightened, it acts to wedge the tapered end of the collet into a gripping engagement with the tubing and, at the same time, forces the collar and tubing assembly into line contact with the connection seat. grips tubing Pressures to 60,000 psi (4137 bar) Slotted Note: 1) To order components with assemblies add -K KCGL40-316 KCL40-316 1/4 0.50 0.81 0.62 KGL40-316 (6.35) (12.70) (20.58) (15) Outside Diameter Tubing Size KCGL60-316 KCL60-316 3/8 0.62 1.12 0.81 KGL60-316 (9.53) (15) (28.45) (20.58) KCGL90-316 KCL90-316 9/16 1.00 1.50 1.19 KGL90-316 (14.29) (25.40) (38.10) (30.23) 60,000 psi (4137 bar) Standard Parker utoclave Engineers collar not included in complete assembly ll dimensions for reference only and subject to change. For prompt service, Parker utoclave stocks select products. Consult your local representative. ll general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. 11
- Sizes to 1 (25.40) Series KCGL - Sizes to 1/4" (6.35), 5/16" (7.94), 3/8" (9.53) For extreme conditions of vibration and/or shock in tubing systems, such as locating a valve or fitting on an uned line near a compressor, utoclave coned-andthreaded connections are offered with the nti-vibration Gland ssemblies. less complex and more economical design than other vibration-resistant connections, the collet gland assembly utilizes the same coned-and-threaded features of utoclave high pressure connections. and KCGL extends the gland nut to provide room for the tapered, slotted collet and collet nut. The design provides a slight difference in angles between the collet and the corresponding taper of the gland nut. s the nut is tightened, it acts to wedge the tapered end of the collet into a gripping engagement with the tubing. Type 316 stainless steel with bonded dry film (316MC) moly lubricant. grips tubing Slotted ody - Pressures to 43,000 psi (2965 bar) Series KCGL - Pressures to 150,000 psi (10342 bar) Note: 1) To order components with assemblies add -K Outside Diameter Tubing Size KCGLX160-316MC KCLX160-316MC 1.0 1.69 2.38 1.50 KCCLX160-316MC KGLX160-316MC (25.40) (25.40) (60.45) (38.10) KCGL40-316MC KCL40-316MC.250 KCCLX40-316MC (6.35) KGL40-316MC KCGL50-316MC KCL50-316MC.312 KCCL50-316MC (7.94) KGL50-316MC KCGL60-316MC KCL60-316MC.375-43,000 psi (2965 bar) Series KCGL - 150,000 psi (10342 bar) KCCLX60-316MC KGL60-316MC (9.53) Standard utoclave Engineers collar not included in complete assembly ll dimensions for reference only and subject to change. For prompt service, Parker utoclave stocks select products. Consult your local representative. KCGL anti-vibes are for 100,000 and 150,000 psi components. WRNING FILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS ND/OR SYSTEMS DESCRIED HEREIN OR RELTED ITEMS CN CUSE DETH, PERSONL INJURY ND PROPERTY DMGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Offer of Sale The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. ny sale contract entered by Parker will be governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request). 2013 Parker Hannifin Corporation utoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0125SE January2013 Caution! Do not mix or interchange parts or tubing with those of other manufacturers. Doing so is unsafe and will void warranty. Instrumentation Products Division utoclave Engineers Operation 8325 Hessinger Drive Erie, Pennsylvania 16509-4679 US PH: 814-860-5700 FX: 814-860-5811 www.autoclave.com Parker Hannifin Manufacturing Ltd. Instrumentation Products Division, Europe Industrial Estate Whitemill Wexford, Republic of Ireland PH: 353 53 914 1566 FX: 353 53 914 1582 Caution! Parker utoclave Engineers, Valves, Fittings and Tools are not designed to work with common commercial instrument tubing and will only work with tubing built to Parker utoclave Engineers ES Specifications. Failure to do so will void warranty. ISO-9001 Certified 121 Vulcan Road, Canning Vale, Western ustralia, 6155 Telephone: +61 8 9456 1300 Facsimilie: +61 8 9456 1400 Email: info@tridentaustralia.com.au Website: www.tridentaustralia.com.au
Tools, Installation, Operation and Maintenance - nti-vibration Gland nti-vibration Gland ssembly Procedure nti-vibration collet gland assembly replaces the standard gland nut. 1. Cone and thread tubing as defined on pages 5 and 6. 2. Slide collet assembly onto tube and install collar as described in the assembly and makeup of connections on page 6. One or two threads should be exposed between the collar and cone. 3. Lubricate male threads on glands (medium pressure assemblies supplied with a baked on dry film lubricant. Lubrication not required.) 4. Tighten gland or collet body to specified torque on page 13. The high pressure collet will grip the tube when the connection gland is tightened. 5. For the medium pressure collet gland assembly, hand tighten the collet gland in place and further tighten 1-1/4 turns with a wrench. When tightening the medium pressure anti-vibe collet nut, hold the collet body with a wrench to prevent the body from turning and over tightening. This will lock the collet against the tube. For subsequent retightening of the medium pressure collet gland, use 3/4 turns past finger tight. Medium pressure 20,000 psi (1379 bar) Gland ody (Gland) Gland High pressure 60,000 psi (4137 bar) Note: lways use a back-up wrench on collet body to prevent over tightening of collet body into connection. Re tool - For female tubing connection cone seat 1. Clamp fitting in soft-jawed vise. 2. Thread gland nut into connection and tighten to 10 ft. lbs. (13.6 N.m). 3. pply a medium weight high sulfur cutting oil generously through opening in nut. Cutting oil P-8784. 5. Remove reamer, guide nut and bushing and inspect cone seat. 6. Repeat steps 2,3,4 and 5, if necessary, until cone surface has been restored and finish is smooth. 7. Clean fitting thoroughly to remove all chips and residue. 4. Insert reamer through guide bushing and press down firmly while rotating clockwise approximately two full turns, relieving pressure gradually toward end of second turn. Guide Nut ssembly Handle Connection Type Complete Guide Nut ssembly Handle SF250CX P-0270CX 101-2005 P-0270 202D-0596 SF375CX P-0271CX 2020-7310 P-0271 202D-0596 SF562CX P-0272CX 2030-7310 P-0896 202D-0596 SF750CX P-1726CX 102-3376 P-1726 201D-0595 SF1000CX P-1727CX 102-3375 P-1727 201D-0595 F250C P-0270C 1010-0453 P-0270 202D-0596 F312C150 P-0271C150 2040-7310 P-0271 202D-0596 F375C P-0271C 1020-0453 P-0271 202D-0596 F562C / C40 P-0272C 1030-0453 P-0272 202D-0596 43F1000C P-1727CX 102-3375 P-1727 201D-0595 10 ll general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Coned-and-threaded Nipples For rapid system make-up, Parker utoclave Engineers supplies pre-cut, coned-and-threaded nipples in various sizes and lengths for Parker utoclave Engineers valves and fittings. Special lengths In addition to the standard lengths listed in the table below, nipples are available in any custom length. Consult factory. numbers in table refer to Type 316 stainless steel, unless specified. Working Fits Tube Size in.(mm) Pressure at Connection 100 F(38ºC) Type O.D. I.D. psi(bar) SF250CX 1/4 (6.35).109 (2.77) 20,000 (1380) SF375CX 3/8 (9.53).203 (5.16) 20,000 (1380) SF562CX 9/16 (14.3).312 (7.92) 20,000 (1380) SF562CX 9/16 (14.3).359 (9.12) 15,000 (1034) SF750CX 3/4 (19.1).438 (11.1) 20,000 (1380) SF750CX 3/4 (19.1).515 (13.1) 15,000 (1034) SF1000CX 1 (25.4).562 (14.3) 20,000 (1380) SF1000CX 1 (25.4).688 (17.5) 15,000 (1034) F250C 1/4 (6.35).083 (2.11) 60,000 (4140) F375C 3/8 (9.53).125 (3.18) 60,000 (4140) F562C 9/16 (14.3).187 (4.78) 60,000 (4140) F562C40 9/16 (14.3).250 (6.35) 40,000 (2760) F1000C43 1 (25.4).438 (11.1) 43,000 (2964) 2 3 4 6 8 10 12 Length Length Length Length Length Length Length CNX4402 CNX4403 CNX4404 CNX4406 CNX4408 CNX44010 CNX44012 CNX6603 CNX6604 CNX6606 CNX6608 CNX66010 CNX66012 CNX9904 CNX9906 CNX9908 CNX99010 CNX99012 CNLX9904 CNLX9906 CNLX9908 CNLX99010 CNLX99012 CNX1204 CNX1206 CNX1208 CNX12010 CNX12012 CNLX1204 CNLX1206 CNLX1208 CNLX12010 CNLX12012 CNX1606 CNX1608 CNX16010 CNX16012 CNLX1606 CNLX1608 CNLX16010 CNLX16012 CN4402 CN4403 CN4404 CN4406 CN4408 CN44010 CN44012 CN6603 CN6604 CN6606 CN6608 CN66010 CN66012 CN9904 CN9906 CN9908 CN99010 CN99012 40CN9904-316 40CN9906-316 40CN9908-316 40CN99010-316 40CN99012-316 43CN1606 43CN1608 43CN16010 43CN16012 Note: dd -316 or -304 to catalog number for material choice if not shown. nti Vibration Gland ssemblies Vibration and/or shock can be present in tubing systems, especially if the valve or fitting happens to be located on an uned line near a compressor. For this reason, Parker utoclave Engineers coned-and-threaded connections are offered with the Parker utoclave Engineers nti-vibration Gland ssemblies. Completely interchangeable with standard Parker utoclave Engineers high pressure connections, the Gland ssemblies provide equally effective pressure handling capability. O.D. Tubing Size Medium Pressure to 20,000 High Pressure to 60,000 1/4 (6.35) KCGLX40-316MC KCGL40-316 3/8 (9.53) KCGLX60-316MC KCGL60-316 grips tubing * Valve or fitting body grips tubing Valve or fitting body 9/16 (14.3) KCGLX90-316MC KCGL90-316 3/4 (19.1) KCGLX120-316MC - sealing * sealing 1 (25.4) KCGLX160-316MC KCGLX160-316MC 1 High Pressure to 43,000 psi (2964 bar) Pressures to 20,000 psi (1380 bar) Pressures to 60,000 psi (1440 bar) *E not included in complete assembly. 9