534HS Pressure Transmitter

Similar documents
3820 Pressure Switch-Transmitter

Big Hermet Pressure Switches

Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor

RF Point Level Control with Sensor Monitor

102 Differential Pressure Switch

Pressure Switch SOR. Sifter ready to run: Adequate pressure to switch. Sifter not ready to run: Either loss of air pressure, or open guard.

Temperature Switches. General Instructions

103 Differential Pressure Switch

Nuclear Qualified Temperature Switches

Ultrasonic Two-Wire Point Level Control

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

T21 Thermal Differential Switch

B Temperature Switches

1451 Control Valve. General Instructions. Table of Contents

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

GE Sensing & Inspection Technologies

Opposed Piston Differential Pressure Switches

1100 Series Piston Type Differential Pressure Gauges

LTX RF LEVEL SENSOR. Instruction Manual

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

Boston Gear Ratiotrol DC Motor Speed Control

Q Range electric direct-drive quarter turn valve actuators. Instruction manual

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

OEM Pressure Transmitters

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

Damper Actuator Installation

SETRA Operating Instructions Series DPT 230 Pressure Transducers

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Figure 1: WPR2 Dimensions and Hardware

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

WARNING! READ BEFORE INSTALLATION

Model 124 Filter Minder & Model 124

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

m WARNING! READ m BEFORE INSTALLATION

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

Warnings and Cautions. Precision Flow Insertion Mass Flow Meter. Instruction Manual BULLETIN F-41-PFS FR# R

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

Type 2390 and 2390B Liquid Level Transmitters

Type Type 1001 Transducers. I/P & E/P Transducers

ATP-2040 Electric Damper Actuator/Transmitter

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

RESISTIVITY MONITOR/CONTROLLERS

Special Purpose Transmitters

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

M9216 Series Electric Spring Return Actuators

OEM Pressure Transmitters

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

Installation. Global Vision Inc Jefferson Hwy - Osseo, MN USA - ph fx

Maximum 20 ma, 24 VDC 825 ohms (see section 3.3) Supply voltage dependence

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

CANADA SENSORS TECHNOLOGY INC.

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

CAP ANALOG 4100 INSTALLATION & OPERATION MANAUL

PXT-K Series. Pressure Transmitters Section 05

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

System 350 S350P Proportional Plus Integral Temperature Stage Module

5001TCP SPEED CONTROLLER

ACCESSORY KIT INSTALLATION INSTRUCTIONS

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

SPRAY RUN-UP CONTROL KIT ( 4-20 ma Version)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

5001TCP SPEED CONTROLLER

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Type 2000 Transducer Product Instructions

FAIRCHILD T5220 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

CTE7000 / CTU7000 Series Miniature pressure transmitters

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Install Guide A Throttle Position Sensor

SmartX MF and MS

MODEL K WIRE INDICATING PRESSURE TRANSMITTER INTRINSICALLY SAFE VERSION OPERATION AND INSTRUCTION MANUAL

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Transcription:

These instructions provide information for installation, process connection, electrical connection and field calibration of SOR 534HS Pressure Transmitters. The 534HS Pressure Transmitter consists of a field proven thin film pressure transducer and a reliable electronic circuit. The housing features external adjustments and stainless steel construction. on. The 534HS is capable of powering long cable lengths. See Formulas for maximum loop resistance formulas. NOTE: This instrument is non-repairable. If you suspect that it is defective, contact the factory or the SOR representative in your area for a return authorization number. Installation Ensure that wiring conforms to all applicable local and national electrical codes and install unit(s) according to relevant national and local safety codes. Normally, line mounting provides adequate support for the instrument. When the installation is complete, the external adjustments must be accessible. (See Figures and ) Determine whether the process connection or the electrical connection will be made first. 534HS Pressure Transmitter General Instructions Making the Process Connection First The process connection is threaded onto a fitting within an adequately supported process piping system. Use two open end wrenches when connecting the pressure port to a NOTE: If you suspect that a product is defective, contact the factory or the SOR Representative in your area for a return authorization number (RMA). This product should only be installed by trained and competent personnel. Design and specifications are subject to change without notice. For latest revision, go to www.sorinc.com Table of Contents Installation...1 Wiring 534HS-TN...2 Calibration...2 Dimensions...4 Wiring 534HS-VN...4 Calibration...5 Dimensions...7 Control Drawings...8-10 Form 953 (03.13) SOR Inc. Registered Quality System to ISO 9001 1/12

process piping system: one wrench to hold the hex flats of the pressure connection, the other to tighten the process fitting. Electrical connection may be rigid or flexible conduit. Making the Electrical Connection First The electrical connection may be installed on an adequately supported rigid conduit system. Use suitable locknuts (not provided) when mounting the instrument to an unthreaded (knockout) hole. Process connection pipe or tubing may be rigid or flexible. Securely connect the conduit pipe or fitting by holding the hex on the electrical connection while tightening. Unit in Hazardous Locations Prior to removal from service, make sure that the work area is declassified. Failure to do so could result in severe personal injury or substantial property damage. Wiring 534HS - TN Three 18 flying leads are provided for connection to a terminal strip within a cabinet or a splice within an outlet box: Red (+) Black ( ) } Loop Voltage: 11 to 30 VDC; Output: 4 to 20 ma Case ground (bare wire) should be connected to earth ground. Formula for determining maximum loop resistance: R L (Max) = V Supply - 11V Calibration Two calibration screws (zero and span) are located underneath the adjustment cover. (See ) Loosen the cover screws slightly (do not remove) and rotate the cover to reveal the adjustment screws. Numbers on the enclosure identify the adjustment screws: 1, 2 and 3. Adjustment #1: Zero Adjustment #2: Not used Adjustment #3: Span Unless specified otherwise, the transmitter is factory calibrated to 4 ma @ 0 psi and 20 ma at the upper limit of the adjustable range specified on the nameplate. Calibration Procedure The zero and span calibration procedure should be performed under ambient process temperature conditions. 2/12 Form 953 (03.13) SOR Inc.

Power Supply 11-30 VDC Case Ground Red Black Bare milliammeter 4-20 ma Zero Not Used Span A pressure source with a calibrated reference gage, a milliammeter and a DC voltage supply are required. Note the adjustable range on the instrument nameplate. For both zero and span adjustments, turn the adjustment screw clockwise to increase, counterclockwise to decrease. Connect the transmitter as shown in. Case ground must be connected to earth ground to ensure EMI/RFI protection. Apply pressure at which 4 ma output is desired. (Zero may be adjusted +10% of the upper range limit.) When zero is elevated above 0 psi, maintain 80% of the range of the transmitter range between the 4 ma and 20 ma points. With pressure source steady at the desired zero level, rotate the zero adjustment (#1) for a 4 ma indication on the milliammeter. Apply pressure at which 20 ma output is desired. Span may be adjusted from 20 to 100% of the upper range limit. (Maximum turndown is 5:1.) With pressure source steady at the desired span level, rotate the span adjustment (#3) for a 20 ma indication on the milliammeter. Repeat Steps 2 through 6 as needed if offsetting 4 ma from the normal zero point. If interaction occurs, turn zero and span 15 turns counterclockwise. Repeat Steps 2 through 7 above. Form 953 (03.13) SOR Inc. 3/12

Dimensions Linear = mm/inches Drawing 0091119 Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. Wiring 534HS-VN Three screw terminals and center ground are provided for electrical connection, labeled as follows: + 11-30 VDC + Power Connection Power supply ground 1-5 VDC Output GND Case ground should be connected to earth ground. Formula for determining maximum loop resistance: R L (Max) = V - 16V Supply 4/12 Form 953 (03.13) SOR Inc.

Calibration Two calibration screws (zero and span) are located underneath the adjustment cover. (See ) Loosen the cover screws slightly (do not remove) and rotate the cover to reveal the adjustment screws. Numbers on the enclosure identify the adjustment screws: 1, 2 and 3. Adjustment #1: Zero Adjustment #2: Not used Adjustment #3: Span Unless specified otherwise, the transmitter is factory calibrated to 1 VDC @ 0 psi and 5 VDC at the upper limit of the adjustable range specified on the nameplate. Calibration Procedure The zero and span calibration procedure should be performed under ambient process temperature conditions. A pressure source with a calibrated reference gage, a voltmeter and a DC voltage supply are required. Note the adjustable range on the instrument nameplate. For both zero and span adjustments, turn the adjustment screw clockwise to increase, counterclockwise to decrease. Connect the transmitter as shown in Figure. Case ground must be connected to earth ground to ensure EMI/RFI protection. Apply pressure at which 1 VDC output is desired. (Zero may be adjusted up to +10% of the upper range limit.) When zero is elevated above 0 psi, maintain 80% of the transmitter range between the 1 VDC and 5 VDC points. With pressure source steady at the desired zero level, rotate the zero adjustment (#1) for a 1 VDC indication on the voltmeter. Apply pressure at which 5 VDC output is desired. Span may be adjusted from 20 to 100% of the upper range limit. (Maximum turndown is 5:1.) With pressure source steady at the desired span level, rotate the span adjustment (#3) for a 5 VDC indication on the voltmeter. Repeat Steps 2 through 6 as needed if offsetting 1 VDC from the normal zero point. If interaction occurs, turn zero and span 15 turns counterclockwise. Repeat Steps 2 through 7 above. Form 953 (03.13) SOR Inc. 5/12

Voltmeter 1 TO 5 VDC 100K ohms min. 1-5 Volt Terminal with respect to negative Case Ground Power Supply 11-30 VDC Terminals show with transmitter at 6 o clock 6/12 Form 953 (03.13) SOR Inc.

Dimensions Linear = mm/inches Drawing 0091124 Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. Form 953 (03.13) SOR Inc. 7/12

Control Drawing 8/12 Form 953 (03.13) SOR Inc.

Control Drawing Form 953 (03.13) SOR Inc. 9/12

Control Drawing 10/12 Form 953 (03.13) SOR Inc.

Form 953 (03.13) SOR Inc. 11/12

Printed in USA www.sorinc.com 14685 West 105th Street, Lenexa, KS 66215 913-888-2630 800-676-6794 USA Fax 913-888-0767 12/12 Registered Quality System to ISO 9001 Form 953 (03.13) SOR Inc.