VAHU Vertical Air Handling Unit

Similar documents
MAH. Modular Air Handling Unit

Complete HVAC Capability

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat


Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

SDL Single-Duct, Low-Height, VAV Terminals

TSS Single-Duct VAV Terminals

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MQL TABLE OF CONTENTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

FN Fan-Coil Units High-Performance, Horizontal

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

Centrifugal Filtered Supply Roof Blowers

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

Filtered Kitchen Supply Packaged Ventilator

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

MODULAR AIR HANDLING UNITS GAH SERIES

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

FS Fan-Coil Units Hi-Rise, Vertical

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

catalog SDL Single-Duct, Low-Height, VAV Terminals

ACTIVE CHILLED BEAM 6 1/4" HEATING 9 1/2" DISCHARGE DIRECTION. 1 7/8" u 1/4" NOZZLE SIZE:

Climas y Proyectos Leyco, S.A. de C.V.

University of Delaware

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Installation, Start-Up and Service Instructions

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

BHH Product Specifications

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

RECORD SUBMITTAL COVER SHEET

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

SECTION AIR TERMINAL UNITS

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

catalog SDL Single-Duct, Low-Height, VAV Terminals

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

Midea Air Handling Unit

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

SPECIFICATION SHEET. C5000 ( cfm)

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Product Data. 39T Central Station Air-Handling Units. Features/Benefits. Nominal 3,500 to 46,000 Cfm

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

D M S 760 C01 A A 1 1

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

Inline and Roof Mounted Fans

CH5000 Heat Recovery Ventilator

Air Handling Unit Construction Checklist

FAN POWERED TERMINAL UNITS

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Dual Duct Variable Air Volume Terminal (Model TDS)

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

Air Handling Unit Fan Selection Guide

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS

Laboratory Room Single Duct Supply Air Terminal

Prepared By : Checked By : Approved By : Page 1 out of 6

Square Inline Fans with Multi-Directional Discharge

EXHAUST FANS CUD & CUB UPBLAST FANS

CS3 Series 50/60Hz. Modular Central Station Air Handling Units Air Volume: 1000 to cfm (1700 to m 3/hr)

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Product Data. Features/Benefits. 39NX Central Station Air-Handling Units. Nominal 2,000 to 55,000 Cfm

XeteX, Inc. All Rights Reserved.

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

Industry best 5 year fan housing warranty, 1 year motor warranty

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L

Energy Recovery Laboratory Exhaust

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

BLOWER COILS BLOWER COILS. Providing You With Air Distribution Solutions F2-1 KRUEGER 2014 FORM - BC.HV /05/14

FCVC Series VERTICAL FAN COILS

Custom Air Handling Unit

DUNHAM-BUSH ecs3 Series

A. NU2035 HRV Specifications NU2035

FILTERED SUPPLY CENTRIFUGAL Belt Drive

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Industry best 5 year fan housing warranty, 1 year motor warranty

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Transcription:

500 to 5,400 CFM @ up to 6.00" TSP 2" double wall construction, perforated or solid lined 18 gauge G90 galvanized steel cabinet 4 standard cabinet sizes available Internally isolated direct drive plug fan ETL listed and labeled

High Quality, High Performance s 500 to 5,400 CFM @ up to 6.00" TSP. Why the Vertical AHU? United Metal Products VAHU line of heating and cooling units offers a high quality, high performance, low maintenance and cost effective small air handling unit where the footprint of a traditional horozontal AHU is not a viable option. The product shares many features with United Metal Products MFC units - designed with a series of standard features typically found on higher quality, larger custom air handling units. Very quiet operation thanks to the direct drive plug fan, even in higher static pressure applications. Small footprint. Zero maintenance direct drive fans with no belts or bearings, and motors with permanently lubricated sealed bearings. #304 SS double sloped drain pans. High efficiency filtration for maximum indoor air quality. No need for external isolators thanks to the internal isolation under the fan and motor. Suitable for Mixed Air, 100% RA, or 100% OSA applications. Applications: The VAHU heating and cooling units have been designed for those applications where the high quality components of an air handling unit are required along with a fan and cabinet that can produce high static pressures without occupying the larger footprint area of a traditional fan coil unit. The 2 double wall cabinet, component options, speed control and vibration isolation all contribute to make the United Metal Products VAHU suitable for applications including: Hospitals Museums Pharmaceutical Laboratories High tech manufacturing Clean rooms Schools & Colleges Commercial Institutional Other acoustically or IAQ sensitive applications Resources Available for This Product: Catalog By Mail Catalog Online Specification Online United Metal Products 1920 E Encanto Drive Tempe, AZ 85281 T 480.968.9550 F 480.968.9555 www.unitedmetal.com VAHU//PO//Rev. 2.2 10-09-06

Key Features: 500 to 5,400 CFM @ up to 6.00" TSP. 2" double wall construction. Perforated or solid. Low-leak cabinet construction less than 1% CFM cabinet leakage at a positive pressure of 6"WG TSP. 18 gauge G90 galvanized steel cabinet. Option for epoxy powder based baked-on coating of all casing panels after all shearing and forming and prior to assembly. ASTM B117 1,500 hours salt spray and ASTM D2247 1,500 hours humidity test compliant. 4 standard cabinet sizes available. Internally isolated direct drive plug fan. 460V/3ph, 230V/3ph or 208V/1ph power capability. Optional factory mounted energy efficient VFD speed control with disconnect. 1, 2, 3, 4, 5 & 6 row chilled water, hot water, steam or DX coils. 5 /8".020" copper tubes, aluminum or copper fins, stainless steel or galvanized casing, ARI certified coils. IAQ double sloped #304 stainless steel drain pans with 3 /4" drain. 2" and 4" filters. Up to 95% efficient high capacity filters available. OA / RA intakes available on the front, back, right or left sides with or without dampers. SA discharge is vertical up. OSA and RA mixing dampers with airfoil, extruded aluminum low-leak blades with or without actuators. Full size hinged double wall access doors with polished stainless steel butt hinges and adjustable latches. Airflow measurement stations available. Single piece construction. Suitable for ground mounting with factory supplied angle feet. ETL listed and labeled to UL1995 Standard Features: 2" double wall construction 3# insulation 20ga G-90 solid inner G-90 galvanized finish casing & Low-leak aluminum airfoil profile dampers 2" 30% panel filters 5 /8".020 copper tube coils.006 aluminum fins Galvanized steel coil casing Copper coil connections Double sloped IAQ #304 stainless steel drain pan with 3 /4" drain Coil vent & drain extended to outside of the cabinet Direct drive plug fans Motor pre-wired to external J- box Premium efficient ODP motors Internal vibration isolation Hinged access doors with locking (or non-locking) T handles ETL listed and labeled to UL1995 Optional Features: 1.5# insulation 22ga G-90 perforated inner #304 stainless steel casing & #316 stainless steel casing & Aluminum casing & Epoxy powder coated casing Epoxy powder coated Low-leak galvanized dampers Low-leak galvanized airfoil profile dampers Formed galvanized dampers Damper actuators 4" 30% panel filters 4" 65%, 85% or 95% cartridge filters Filter pressure drop gauges.008/.010 aluminum fins.006/.008 copper fins #304 stainless steel coil casing Red brass coil connections Double sloped IAQ #316 stainless steel drain pan with 3 /4" drain Motor pre-wired disconnect Motor pre-wired to VFD Motor pre-wired to VFD and disconnect Premium efficient TEFC motors VAHU//FEATURES//Rev. 2.2 10-09-06

VAHU Capacity and Option Details VAHU Size & Capacity Fan Section - See Notes Air Volume CFM Exterior Cabinet Size Fan Sizes (") and Max. Motor HP / Frame Size Available with ODP Motors min max W D H 9 10 11 12 15 16 18 20 22 24 VAHU-1100 500 1,100 VAHU-2500 1,000 2,500 VAHU-3750 1,500 3,750 41 VAHU-5400 2,250 5,400 48 48 118.25 x x 22 2 HP 143T 2 HP 143T Coil Section Filter Section Heating Coil Cooling Coil Filter Size, Qty & Face Area Efficiency and Depth Face Area sq.ft Face Area 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row H x W Qty. sq.ft 30% 30% 65% 85% 95% sq.ft 1.6 2.33 VAHU-1100 1 2.00 2" 4" 4" 4" 4" 3.21 VAHU-2500 1 4.00 2" 4" 4" 4" 4" 4.58 24 x 24 + 12 x 24 VAHU-3750 1 + 1 6.00 2" 4" 4" 4" 4" 10.75 5.25 7.88 11.33 VAHU-5400 4 11.11 2" 4" 4" 4" 4" 12 x 24 24 x 24 20 x 20 VAHU-1100 VAHU-2500 VAHU-3750 VAHU-5400 Inlet or Mixing Section - See Notes Front and Back Location. Opening or Damper HxW H Left or Right Location. Opening or Damper HxW W H W W 12 14 12 14 12 24 12 24 18 12 24 12 30 18 30 18 24 18 Supply Discharge Top Discharge Opening WxD D 12 12 18 18 24 24 NOTES: Add 6" to unit width when including for the 3" angle feet on each side. All access is from the "Front" of the unit. Doors are hinged on the left side of the door as standard, with 1/4 turn compression latch handles on the right side of the door. All "Front" mounted dampers will be mounted on the outside of the cabinet and will extend 5" beyond the cabinet unless otherwise noted. "Right", "Left" and "Back" mounted dampers may be recessed depending on the location of the other dampers. All fans 12" diameter and larger are available with reduced % wheel width. VAHU//CAPACITY//Rev. 2.2 10-09-06

VAHU Layout Form To: By: Date: Project: Tag: Engineer: Model: Heating Coil Area (sq.ft): Cooling Coil Area (sq.ft): Filter Area (sq.ft): Unit Width (") **: Unit Depth ("): Unit Height ("): Operating Weight (Lbs) *: VAHU-1100 VAHU-3750 VAHU-5400 VAHU-2500 1.60 2.33 2.00 22 760 3.21 5.25 4.00 910 4.58 7.88 6.00 41 1,030 10.75 11.33 11.11 48 48 118.25 1,740 Panel Thickness and Insulation Density 2" Double Wall #1.5 Insulation #3 Insulation Casing Materials Lining Materials 18ga Galv 18ga Pre-painted Steel 18ga UMP Painted 18ga #304 Stainless Steel 18ga #316 Stainless Steel Smooth Perforated Notes: Supply Fan: CFM: TSP: ESP: Arr: 4 Cl: HP: RPM: Encl: Eff: V/Ph: Frame: JBox Disc. VFD VFD w/ Disc. CV VAV *** *** All VAHUs require VFD to set fan speed. Chilled Water or DX Coil Rows / FPI Tube: Fins: Cas: Hot Water or Steam Coil Rows / FPI Tube: Fins: Cas: Tubes are 5/8" (0.02") copper. Fins are.006",.0075" or.009" thick Aluminum or Copper. Coil cases are either Galv or Stainless Steel. Filters: 2" 30% 4" 30% 4" 65% 4" 85% 4" 95% Cl: Gauge: Inlet Air Options Mixing Box 100% O/A 100% R/A Include Damper(s) Include Damper(s) with free issue actuator(s) A.M.S. Mfg: Series: Power: 0-10VDC 4-20mA SA RA OSA Notes: * Operating weights are based on galvanized construction with 3# insulation, 2 dampers, 2" filters, 2 row heating coil, 4 row cooling coil, with the largest fan and motor available. ** Add 6" to unit width when including for the 3" This layout sketch is the TOP VIEW. Show access door, electrical, angle feet on each side. OA/RA inlets and coil / drain connection locations. Back Side Left Side Right Side Front (door) Side VAHU//LAYOUT//Rev. 2.2 10-09-06