MAGNETIC PROXIMITY SWITCHES

Similar documents
GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

E2K-L. Liquid Level Sensor. Applications. Ordering Information

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

Safety Limit Switch

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

DC2-Wire Unshielded Cylindrical Proximity Switches

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C.

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

E2EZ-X2D1-N E2EZ-X2D2-N

GL-6 SERIES. Miniature Inductive Proximity Sensor. High Performance in Surprisingly Small Body. Marked. Extremely Small.

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

AC/DC2-wire Type Cylindrical Proximity Switches

FL7MSeries. DC2-Wire Regular Cylindrical Proximity Sensors

A22NK. Key-type Selector Switches

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Inductive Proximity Sensor

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

SG-B1 SERIES / SG-A1 SERIES

Not affected by drops, bubbles or froth

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

MPS Series Proximity Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

2NC (slow-action) Direct. Model. opening

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Inductive Proximity Sensor

HL (AZH) LIMIT SWITCHES

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Hermetically Sealed Power Contact

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

HL (AZH) Limit Switches

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

Model Number Structure

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

High-speed detection even a little liquid leak

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

VL (AZ8) Limit Switches

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

3 Port Solenoid Valve

Ordering Information. Text Surface-Mounting Signal Relay G6K

EX-F70 SERIES EX-F60 SERIES

Technical Guide for Basic Switches

Magnetic Proximity Switch MSW-L (Latching Type) DC/AC Version CE Classification: M2C235AU9

CAUTION CM-SE CM-S21 CM-S41

HS1L Interlock Switches with Solenoid

Power Controller. (see note 1) 10 sec

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

HL (AZH) Limit Switches

Pressure sensor with built-in amplification and temperature compensation circuit

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Rectangular-shaped Inductive Proximity Sensor.

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

DC2-Wire Regular Cylindrical Proximity Switches

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Application Description

Manual Reset Limit Switch

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Model Pressure range ON/OFF output Linear output

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

AM1 (NZ BASIC) SWITCHES

TURQUOISE STROKE SWITCHES

VL (AZ8) Limit Switches

ROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Safety-door Switch. Ordering Information

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Hall Coded Non-contact Safety Switches. Model Number Structure

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Switching Power Supply

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

HS1C Interlock Switches with Solenoid

Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

General Purpose Relay

RODLESS BAND CYLINDERS WITH CARRIER BRACKET-TYPE STB SERIES 446

SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES

Transcription:

Bestact MAGNETIC PROXIMITY SWITCHES Vane PSMO Separate PSMS Memory PSMM Column PSMS_RV Omnidirectional Sensor PSMT A Wide Variety of s Available to Meet Applications/Specifications for General Purpose, High Temperature, etc. The Two-Wire System Provides a Wide Power Range. FEATURES 1. Completely sealed construction makes this switch best suited for adverse environments. 2. Direct control for loads of 100VDC or greater. No power supply or amplifying relay needed. 3. No protective circuit needed even for long cable wiring or inductive load. 4. No erroneous operation or breakdown due to noise and surge. 5. The contactless design assures a long service life and maintenance-free operation. 6. Economical proximity switches. Magnet characteristics for Bestact Operation TYPES AND HOW TO USE Magnetic proximity switches are usually classified into two types: an integrated type such as vane type and a separate type. Switch operation principle is described below. Vane type Vane type Vane type switches detect materials without any physical contact. Materials enter into or pass by the groove of U-shaped structure. In general, the detected materials are made of flat shape and ferromagnetic materials such as iron plates. The switches provide high detecting accuracy even if the detected materials have play. They have only a few constrained conditions and very easy to use. In various detecting devices incorporating Bestact, Yaskawa selected and designed carefully the materrials that energize contacts to maintain long-term high operation accuracy. Permanent magnets used for Yaskawa s detecting devices are rare earth magnets and anisotropic ferrite magnets which have high coercive force and large energy product. Yaskawa designed the optimum magnet shapes and the magnets are highly stable without demagnetization. Demagnetization due to aging is 2% or less for a 10 year period. APPLICATION EXAMPLES Circuit Example Using Conventional Limit Switch 60 Separate type Separate type The switch unit is fixed, and the magnet unit is mounted on the moving object to be detected. Approach or passage of the magnet unit will be detected without contact. (Memory type) Separate type doesn't need any separately-mounted detecting unit. Moreover, one magnet unit can energize several switch units. Various detecting methods are available to match your specifications. X: RELAY FOR SELF-HOLDING R: RESET CONTACT (Circuit needs self-holding relay). Circuit Example Using Bestact Memory Switch Logic circuit is simplified because no self-holding relays needed.

VANE TYPE MAGNETIC PROXIMITY SWITCHES PSMO-04G2 RATINGS AND SPECIFICATIONS Contact Arrangement Incorporated Bestact Rated Insulation Voltage Contact Performance Insulation Resistance Withstand Voltage (Power Frequency) Vibration Resistance Shock Resistance Erroneous Operation Breakdown Operating Temperature Connecting Terminal PSMO-04G2 1NO 250VAC (Power Frequency) Refer to page 7. 100M or greater (with 500VDC Megger) 1500VAC for 1 minute, Leakage Current: 5mA (Across Open Contacts: 500VAC) 9.8m/s 2 {1G} 98m/s 2 {10G} 980m/s 2 {100G} 10 to +50 Screw Size: 3.5 8(Screw With Plain/Spring Washer) DIMENSIONS in mm Note: When switche is used in a DC circuit, connect terminal 1 to G and number 2 to F. 61

VANE TYPE MAGNETC PROXIMITY SWITCHES High Detecting Accuracy against Unstable Moving Materials and Easy to Use Can control circuits of 100VDC or greater without any power supply unit or amplifying relay No erroneous operation or circuit failure due to noise or surge Contactless design assures long service life and maintenance-free operation PSMO-G (Medium-Capacity) PSMO-E (Large-Capacity) RATINGS AND SPECIFICATIONS Medium-Capacity Groove Width mm Groove Depth mm Contact Arrangement 24 52 1NO 24 52 1NO 24 52 1NC 24 52 1NC Incorporated Bestact Enclosure IP50 IP67 IP50 IP67 Common Ratings and Specifications Note: 1. Refer to page 59 for Degrees of Protection. 2. Models with indicating lamps have the following symbol. PSMO-25G1T/L 4: For 100V 5: For 200V 3. Except for the model with an indicating lamp. Large-Capacity PSMO-25G1 Operating Temperature: 10 to +50 Storage Temperature: 25 to +70 Rated Insulation Voltage: 250VAC (Power Frequency) Insulation Resistance: 5M or greater (with 500VDC Megger) Withstand Voltage (Power Frequency): 1500VAC for 1 minute 3, Leakage Current: 5mA (Across Open Contacts: 500VAC) With Indicating Lamp, available on order. (For 100 or 200V only) 2 Cable: 0.75mm 2 2 conductors 1m long. (Dustproof type IP 50 without lamp: 2.5m long) Standord Vane Detected mm: t1.6 60 100 (t1.2 or greater) Refer to page 7 for Contact Performance. PSMO-05E2 1 PSMO-25E1 1 PSMO-25E2 1 PSMO-25E1T PSMO-25E2T Groove Width mm Groove Depth mm Contact Arrangement 5 36 1NC 25 90 1NO 25 90 1NC 25 120 1NO 25 120 1NC Incorporated Bestact Connecting Method R15 Screw terminal or cable (1m) R15 Screw terminal or cable (1m) R15 Screw terminal or cable (1m) R15 Cable (2m) R15 Cable (2m) Standard Vane Detected 2 mm t 1.6 15 45 t 2.3 50 100 t 2.3 50 100 t 2.3 50 135 t 2.3 50 135 Common Ratings and Specifications Enclosure: Waterproof type IP 67 3 Operating Temperature: 10 to +80 (with cable: 10 to +60) Storage Temperature: 25 to +70 Switching Frequency: 3600 times/hour (7200 times/hour 4 ) Rated Insulation Voltage: 250VAC (Power Frequency) Insulation Resistance: 5M or greater (with 500VDC Megger) PSMO-25G1T PSMO-25G2 PSMO-25G2T Withstand Voltage (Power Frequency): 1500VAC for 1 minute 5, Leakage Current: 5mA (Across Open Contacts: 800VAC) With an Indicating Lamp, available on order. (For type PSMO-25, 100 or 200V only) 6 Cable: 1.25mm 2 2 conductors. Refer to page 7 for Contact Performance. 62 Note: 1. Models with cables have suffix P in type names. <Example> PSMO-05E2/P 2. Vane size of ferromagnetic structural iron plate. 3. Screw terminal of type PSMO-05E2 cannot be used as waterproof type since the screw terminal is exposed. 4. Only applicable for light loads such as power relays. 5. Except for the models with indicating lamps. 6. Models with indicating lamps has the following symbol. PSMO-25E1/L P 4: For 100V 5: For 200V

OPERATING CHARACTERISTICS PSMO-25G1 PSMO-25G2 PSMO-05E2 PSMO-25E1, -25E1T, and -25E1TH PSMO-25E2, -25E2T, and -25E2TH Note: 1. : Pass-through detection type : that returns to the original position after operation. 2. When a vane moves from the right, the operating characteristics are axisymmetric to the above characteristics. 3. Action and reset range shown above indicates the difference of each switch. However, this is not the difference of each operation at repetitive detections. Repetitive detecting accuracy is ±0.2mm. INFLUENCE BY ENVIRONMENTAL CONDITIONS 4Operating characteristics when iron particles are adhered Adhesion of iron particles (60g) (If iron particles are adhered as shown in this picture, influence is only a little bit.) ACTION AND RESET POSITION (mm) Example of PSMO-25E1 4Ambient temperature and operating characteristics ACTION AND RESET POSITION (mm) PSMO-05E2 ACTION AND RESET POSITION (mm) RESET ACTION RESET RESET ACTION ACTION ADHESION OF IRON PARTICLES (g) AMBIENT TEMPERATURE () AMBIENT TEMPERATURE () PSMO-25E1, -25E1T (-25E1TH) 63

DIMENSIONS in mm Weight: 0.4kg PSMO-25G PSMO-05E2 Weight: 0.7kg PSMO-25E Weight: 0.8kg PSMO-25ET Weight: 1kg HOW TO USE (1) Mounting on magnetic materials Where the magnetic materials are outside of the range as illustrated below, normal switch operation should occur. (2) Vane configuration Standerd vane size should be bigger than shoown in ratings and specifications on page62. Insertion depth of the vane should be at least beyond the red line. The switch shouldn't contact the vane in the groove. (3) Operation speed of vane The faster the vane passes, the quicker the switch will operate. To assure the operating speed of 30ms or greater with the standard vane, use it at the following speeds. s PSMO-25D1, -25D1T 100m/min or less s PSMO-25D2, -25D2T 150m/min or less For higher speeds than these, the vane should be wider. Minimum speed is not particularly limited. (4) Mounting of more than one switch When a mounting interval of type PSMO switches is larger than the above-mentioned allowable mounting dimension on magnetic materials, the normal operating function should not be affected. (5) Connections of leads When the switch is used in a DC circuit, connect a black lead wire of connection cable or terminal code 1 to G and a white lead wire or terminal code 2 to F. (6) Influence of external field Use proper shielding when using in the vicinity of large external magnetic fields (near large power cables, magnet cranes, magnetic stirrers, etc. where leakage flux of 1 mt or greater exists) to avoid erroneous operation. (7) Indicating lamp When a indicating lamp is provided, leakage current should be in consideration. 64

VANE TYPE MAGNETIC PROXIMITY SWITCHES PSMO-06G11J 2 outputs with 1NO1NC contact included while conventional vane type switches have only 1 output due to vane passage. Can save mounting space and allow 2 different kinds of voltage circuits. High contact reliability, best suited for use in an adverse environment. FEATURES Space saving Incorporated 1NO1NC contact can save space. Optimum for rolling stock door interlock system. Maintenance-free Achieves high-frequency switching and long-term durability/ maintenance-free operation by employing a non-contact detection mechanism. No protection circuit needed No protection circuit needed unlike conventional reed switches. Free from sticking, achieves high durability for surge voltage and noise. Total cost reduction No power supply or amp needed unlike contact-less type. Makes the circuit simple and easy to use while providing significant cost reduction. MOUNTING AND OPERATING CHARACTERISTICS Recommended vane material: SPCC&SPHC (Magnetic material), Thickness: 1.2mm, width 50mm or greater Recommended vane inserted depth: 39mm or greater 65

CONTACT RATINGS AND SPECIFICATIONS Contact Arrangement Incorporated Bestact Rated Insulation Voltage Contact Performance Insulation Characteristics Vibration Malfunction Withstand Vibration Shock Malfunction Dropping Shock Cable Insulation Resistance Withstand Voltage (Power Frequency) Operating Ambient temperature PSMO-06G11J 1NO1NC 250VAC (Power Frequency) Refer to page 7. 100M or greater (with 500VDC Megger) 1500VAC for 1 minute, Leakage Current: 5mA (Across Open Contacts: 500VAC) 10 to 240Hz, 19.6m/s 2 {2G} (Double Amplitude) 3 directions Refer to JIS E 4031 Annex JA Category 2 Class B 59m/s 2 {6G} 3 directions Refer to JIS E 4031 Annex JA Category 2 Class B 10 to +50 UL 2464 4 conductors cable (A WG 20) 1m Note: 1. Degrees of protection is dust-proof type (standard). Contact Yaskawa for waterproof type (IP67). 66

DIMENSIONS in mm Orange NO contact Blue Pink NC contact Lime green Contact Cable color Connecting Wires in DC circuit NO NC Orange Blue Pink Lime green G F G F Recommended Insertion Depth: 39mm or greater 67

HIGH-PRECISION VANE TYPE MAGNETIC PROXIMITY SWITCHES Easy Adjustment for Stop Levelling of Hydraulic Low-Speed Elevators. This High-Precision Products provide Adjustment-Free Operation. PSMO-15G (Medium-capacity) RATINGS AND SPECIFICATIONS Contact Arrangement Incorporated Bestact Operating Characteristics (mm) 1 UP-ON UP-OFF DOWN-ON DOWN-OFF Response 2 Enclosure 3 PSMO-15G1 PSMO-15G2 PSMO-15G2S PSMO-15G1T PSMO-15G2T 1NO 1NC 1NC 1NO 1NC 9 to 20 26 to 35 18 to 29 3 to 12 12 or less 20 to 29 14 to 24 9 to 18 14 to 24 12 or less 20 to 29 9 to 18 6 or less 9 to 20 26 to 35 18 to 29 3 to 12 12 or less 20 to 29 14 to 24 9 to 18 14 to 24 12 or less Dust-proof type IP50 Waterproof type IP67 Common Ratings and Specifications Operating temperature: 10 to +50 Storage temperature: 25 to +70 Rated Insulation Voltage: 250VAC (Power Frequency) Insulation Resistance: 5M or greater (with 500VDC Megger) Withstand Voltage (Power Frequency): 1500VAC for 1 minute, Leakage Current: 5mA (Across Open Contacts: 500VAC) Cable: 0.75mm 2 2 conductors 1m long. Refer to page 7 for Contact Performance. Note: 1. Operating characteristics are nearly symmetric to vane passage direction (vertical). Values tabulated are the ones at insertion depth of 40mm. 2. Response shows the difference between the operating point and releasing point (absolute value) as shown in figure below. (1) After the switch is operated in UP direction, it is released in DOWN direction. (2) After the switch is operated in DOWN direction, it is released in UP direction. TYPICAL APPLICATIONS Stop level detecting switches and door-open command switches for passenger and freight elevators, stop level detecting switches for vertical parking garages, passage point detecting switches for transport machineries and passage detector switches for general industrial machineries. 3. Refer to page 59 for degrees of protection. 4. Ultra-high precision products with even narrower operational range are also available. For details, contact Yaskawa. 68

OPERATING CHARACTERISTICS (Actuating range when the vane passes through in a horizontal direction at insertion depth of 40mm.) PSMO-15G1 PSMO-15G2 DIMENSIONS in mm Approx. Weight: 0.4kg Note: 1. This switch operates by passage of magnetic materials. Provide insertion depth of 40mm or greater. 2. When the switch is used in a DC circuit, connect the black lead to G and the white lead to F. 69

NOTE FOR INSTALLATION CAUTION MTG screw torque for M6 must be 3.2 to 3.9 (Nm) {33 to 40 (kgfcm)} PSMO-15 Series: 30mm Pitch Use two screws for mounting when mounting surface is flat. Effective screw depth is 10mm. 2 OBLIGATION Vane mounting position Contacts incorporated in these switches operate and release by passage of vanes (Iron plates). Use magnetic materials (Plate thickness: 1.2 to 2.3mm, Width: 60mm or greater) such as ferromagnetic structure iron plate. The insertion depth in the detecting groove must be set further than the red line indicated on NP. PSMO-15 Series: 20mm Width Only one screw is needed for mounting when attachment (20mm width) is used. Effective screw depth is 12mm. CAUTION Allowable mounting dimension for magnetic material Operational characteristic can be changed when magnetic material is too close to these switches. Magnetic material should be outside of the range as illustrated below. MAGNETIC MATERIAL PSMO-15 SERIES: 14mm GAP Allowable mounting pitch Allowable mounting pitch is 100mm or greater when more than one switch is mounted in parallel or multistage. (Operating characteristics can be changed. Confirm them after mounting.) MAGNETIC MATERIAL MAGNETIC MATERIAL MAGNETIC MATERIAL MAGNETIC MATERIAL MAGNETIC MATERIAL 70 Vane mounting Vanes must be mounted securely so they will not contact the switches or be bent by permanent magnets incorporated in the switches.

SEPARATE TYPE MAGNETIC PROXIMITY SWITCHES A Great Number of Combinations of Switch Units and Magnet Units Available to Set up an Best-Suited Detecting System Directly controls 100VDC or greater without any power supply unit or amplifying relay No erroneous operations or circuit failure due to noise and surge Contactless detection assures maintenance-free operation and long life PSMS (Medium-capacity) (Large-capacity) RATINGS AND SPECIFICATIONS Medium-Capacity Switch Unit Magnet Unit Rated Sensitive Distance mm Maximum Sensitive Distance mm Contact Arrangement Incorporated Bestact Enclosure 1 Switching Frequency Rated Insulation Voltage Contact Performance Insulation Resistance Withstand Voltage (Power Frequency) Ambient Temperature Operating Temperature Storage Note: 1. Refer to page 59. PSMS-R1G1 PSMS-MP10 10 10 to 12 1NO Dustproof type IP50 3600 times/hour 250VAC (Power Frequency) Refer to page 7. 5M or greater (with 500VDC Megger) 1500VAC for 1 minute, Leakage Current: 5mA (Across Open Contacts: 500VAC) 10 to +60 25 to +80 OPERATING METHOD Two actuation directions of the magnet available to operate the switch. 4Short axis direction Easy to mount and the most stable operating characteristics are assured. 4Vertical direction Operating characteristics are stable. However, a special mounting method should be taken depending on the stop condition. Large-Capacity Switch Unit (Incorporated Bestact) 1 PSMS-R1E1 Magnet Unit PSMS-M105 Rated Sensitive Distance 2 mm 5 Maximum Sensitive Distance 3 mm 8 to 11 Common Ratings and Specifications 3 PSMS-R2E1 PSMS-M215 15 16 to 24 Contact Arrangement: 1NO Enclosure: Waterproof type IP67 5 Operating Ambient Temperature: 10 to +60 Storage Ambient Temperature: 25 to +80 Rated Insulation Voltage: 250VAC (Power Frequency) Withstand Voltage (Power Frequency) 1500VAC for 1 minute, Leakage Current: 5mA (Across Open Contacts: 800VAC) PSMS-R3E1 PSMS-M325 25 30 to 40 PSMS-R4E1 PSMS-M450 PSMS-MX70 50 70 65 to 85 100 to 110 Refer to page 7 for Contact Performance. Note: 1. Incorporated Bestact type is R15 2. Detectable distance when both switches and magnet units are mounted on iron plates at ambient temperature of 20. 3. This shows the maximum interval between units when the switches are mounted on non-magnetic materials at 20. (Value range shows performance variation of each product but not the variation due to repetitive operations.) 4. Only switch units are equipped with a cable of 1 meter long. 5. Refer to page 59. 71

OPERATING CHARACTERISTICS <Short axis direction, vertical stroke range> Detection in Short Axis Direction R1G1 AND MP10 R1E1 AND M105 R2E1 AND M215 R3E1 AND M325 R4E1 AND M450 INFLUENCE BY ENVIRONMENTAL AND OPERATING CONDITIONS 4Operating characteristics when iron particles are adhered (e.g. of R3E1 and M325, R3E1H and M325T) Adhesion of iron particles (30g) (If iron particles are adhered as shown in this picture, influence is only a little bit.) (e.g. of R3E1 and M325, R3E1H and M325T) CENTER DEVIATION IN LONG AXIS DIRECTION VERTICAL OPERATING POINT AND RELEASING POINT (mm) DIMENSIONS in mm (e.g. of R3E1 and M325) (e.g. of R3E1 and M325) VERTICAL OPERATING POINT AND RELEASING POINT (mm) ADHESION OF IRON PARTICLES (g) AMBIENT TEMPERATURE () 4Influence by deviance in long axis direction during short axis movement 4Ambient temperature and operating characteristics OPERATING POINT DEVIATION IN LONG AXIS DIRECTION 4Comparison of performance when mounting on magnetic and non-magnetic materials <IRON PLATE MOUNTING> (BOTH SWITCH UNIT AND MAGNET UNIT) <NON-MAGNET MATERIAL MOUNTING> (BOTH SWITCH UNIT AND MAGNET UNIT) Refer to page 77. Weight: 0.08kg Weight: 0.13kg Weight: 0.22kg PSMS-R1G1 PSMS-R1E1 PSMS-R2E1 72

PSMS-R3E1 Weight: 0.35kg PSMS-R4E1 Weight: 0.9kg Weight: 0.04kg Weight: 0.03kg Weight: 0.16kg PSMS-MP10 PSMS-M105 PSMS-M215 PSMS-M325 PSMS-M450 PSMS-MX70 Weight: 0.45kg Weight: 1.4kg Weight: 3kg HOW TO USE 4Repetitive detection accuracy If detecting distance does not vary after mounting the product, repetitive operation accuracy is within ±1mm at temperature change of ±20. When the detecting distance varies repetitively, the accuracy will also change. 4Allowable magnet unit speed of detected materials (at 20) Operating Conditions of Magnet Unit PSMS-M105 PSMS-M215 PSMS-M325 Detecting Distance (mm) Allowable Magnet Unit Speed in Short Axis Direction (mm/s) 5 320 or less 15 625 or less 25 770 or less (3) There is no interference with each other if two or more switch units are mounted in parallel. Thus, it is possible to determine the required mounting pitch in combination for individual actuation range. (4) When mounting two or more magnet units in parallel, follow the instruction illustrated below for the direction of magnet polarity (N or S). The nameplate are good indications for the direction. WRONG GOOD WRONG GOOD MAGNET SHIFT DIRECTION MAGNET UNIT NAME PLATE Note: 1. Values tabulated above are based on the switch unit ON time: 50ms. 2. When the speed is faster than above, mount the magnet units in parallel. 4Connection When the switch is used in a DC circuit, connect the black lead wire to G terminal. 4Mounting 4How to adjust the gap The contact operates when the center of the magnet unit passes ON and OFF area. (1) Unit can even be mounted to flat magnetic materials such as iron plates. However, do not mount the units so that they are surrounded by magnetic materials. (2) When mounting the units, align the magnetic center arrows each other to adjust the misalignment in long axis direction. 73

MEMORY TYPE MAGNETIC PROXIMITY SWITCHES Self-Holding Magnetic Proximity Switches Make Sequencing Simple PSMM RATINGS AND SPECIFICATIONS Switch Unit Magnet Unit Incorporated Bestact Rated Sensitive Distance mm Operational Gap Range mm Enclosure 2 Shock Resistance 3 (malfumction) 3 Vibration Resistance (malfumction) Maximum Response Speed Rated Insulation Voltage Contact Performance Insulation Resistance Withstand Voltage (Power Frequency) Ambient Temperature 1 1 PSMM-RPE1U PSMM-MP15U R15 15 (when mounted on non-magnetic materials) 816 (when mounted on non-magnetic materials) Drip-proof type IP52 (NEMA 2) 98m/s 2 {10G} 49m/s 2 {5G} (10 to 55Hz) 200m/min 250VAC (Power Frequency) Refer to page 7. 100M or greater (with 500VDC Megger) 1500VAC for 1 minute, Leakage Current: 5mA (Across Open Contacts: 800VAC) 10 to +60 25 to +80 Note: 1. At ambient temperature of 20. Sensitive distance where ambient temperature T () can be calculated by the following equation. Sensitive distance (mm) = Rated sensitive distance {1-0.0018 (T-20)} 2. Refer to page 59. 3. Values when the switch unit is mounted correctly on a non-magnetic material. These values can decline depending on a magnetic material and mounting direction. OPERATING CHARACTERISTICS Operating Temperature Storage MOUNTING MG HORIZONTAL MOVEMENT OPERATING METHOD The magnet unit that switches the contact moves in long axis direction. When the magnet moves to ON side, the contact is turned on and maintained. MG VERTICAL MOVEMENT DIMENSIONS in mm PSMM-RPE1U (Switch Unit) PSMM-MP15U (Magnet Unit) This unit should be mounted on non-magnetic materials. When the switch is used in a DC circuit, connect brown lead wire to G, and blue lead wire to F. 74 Weight: 0.12kg Weight: 0.1kg

VANE TYPE HIGH-TEMPERATURE-USE MAGNETIC PROXIMITY SWITCHES PSMO-H Unsurpassed Performance at High Temperature, Humidity Atmosphere; Exceeding any Non-Contact s. 130 C Continuous or 180 C for Short Time (10 Minutes or Less) Direct control of 100VDC or greater, no power supply unit or amplifying relay needed No erroneous operation or breakdown in circuit due to noise and surge Contactless design assures long service life and maintenance-free operation RATINGS AND SPECIFICATIONS Contact Arrangement Incorporated Bestact Groove Width Insulation Resistance PSMO-25E1TH 1NO R15 25mm PSMO-25E2TH 1NC Groove Depth Enclosure Standard Vane Size 120mm Flood tight type IP67 Structural iron plate (SPCC, etc.) t 2.3 50 135mm Ambient Temperature Operating Temperature Storage 25 to +130 40 to +150 Rated Insulation Voltage Contact Performance 250VAC (Power Frequency) Refer to page 7. Insulation Characteristics Withstand Voltage (Power Frequency) 5M or greater (with 500VDC Megger) 1500VAC for 1 minute, Leakage Current: 5mA (Across Open Contacts: 800VAC) TYPICAL APPLICATIONS Continuous casting machines, coke ovens, converters, rolling mills, cement curing ovens, equipment in refrigerators. Cable Heatproof cable (4.6DIA. 0.75mm 2 2 conductors) 3m long Note: 1. As for ratings and specifications other than tabulated above, refer to those of standard types on page 62. 2. Refer to page 59. DIMENSIONS in mm PSMO-25ETH Influence of ambient temperature and compensation Where temperature varies widely from the beginning and during operation, the actuating point and return point may change a little due to the thermal characteristics of the magnetic unit. Therefore, for applications requiring higher accuracy, compensate for the change before mounting. Connection When the switch is used in a DC circuit, connect black lead wire to G, and white lead wire to F. Weight: 1.0kg 75

NOTE FOR INSTALLATION CAUTION Allowable mounting dimension for these switches. These switches must be mounted with the center of the mounting holes less than 55mm from the edge of the mounting surface. 2 OBLIGATION Vane mounting position Contacts incorporated in these switches operate and release by passage of vanes (Iron plates). Use magnetic materials (Plate thickness: 2.3mm or greater, Width: 50mm or greater) such as ferromagnetic structure iron plate. The insertion depth in the detecting groove must be set further than the red line indicated on NP. CAUTION Allowable mounting dimension for magnetic material Operating characteristics can be changed when magnetic material is approaching to these switches. Magnetic material should be outside of the range as illustrated below. Allowable mounting pitch Allowable mounting pitch is 180mm or greater when more than one switch is mounted in parallel or multistage. (Operating characteristics can be changed. Confirm them after mounting.) 76 Vane mounting Vanes must be mounted securely so they will not contact the switches or be bent by permanent magnets incorporated in the switches.

SEPARATE TYPE HIGH-TEMPERATURE-USE MAGNETIC PROXIMITY SWITCHES Designed for High Temperature, High Humidity Atmosphere; Exceeding any Non-Contact s. Resistant to 130 for Continuous Duty or 180 for Short Time (10 Minutes or Less) Direct control of 100VDC or greater, no power supply unit or amplifying relay needed No erroneous operation or breakdown in circuit due to noise and surge Contactless design assures long service life and maintenance-free operation RATINGS AND SPECIFICATIONS PSMS-H, T Switch Unit Magnet Unit Rated Sensitive Distance mm Maximum Sensitive Distance mm Contact Arrangement Incorporated Bestact Rated Insulation Voltage Enclosure Cable 4 Insulation Characteristics 1 2 Insulation Resistance Withstand Voltage (Power Frequency) Operating Ambient Temperature Temperature Storage PSMS-R2E1H PSMS-M215T TYPICAL APPLICATIONS 15 16 to 24 DIMENSIONS in mm PSMS-M325T 25 30 to 40 1NO R15 PSMS-R3E1H PSMS-M450T 50 65 to 80 250VAC (Power Frequency) Waterproof type IP67 5M or greater (with 500VDC Megger) 1500VAC for 1 minute,leakage Current: 5mA (Across Open Contacts: 800VAC) 25 to +130 40 to +150 3m long heat-resistant cable (4.6mm outer dia, 0.75mm 2 2 conductors) PSMS-MX70T 70 100 to 110 Note: 1. Detectable distance at ambient temperature of 20 when both the switches and the magnet units are mounted on iron plates. Setting gap where ambient temperature T () can be calculated by the following equation. Setting gap (mm) =Rated sensitive distance {1-0.0018 (T-20) } 2. Maximum detectable distance when the switch is mounted on a non-magnetic material. (Value range shows performance variation of each product but not the variation due to repetitive operations.) 3. As for ratings and specifications other than tabulated above, refer to those of standard types on page 71. 4. Refer to page 59. Continuous casting machines, coke ovens, converters, rolling mills, cement curing ovens, equipment in refrigerators. Influence of ambient temperature and compensation Where temperature varies widely from the beginning and during operation, the actuating point and return point may change a little due to the thermal characteristics of the magnetic unit. For applications requiring higher accuracy, compensate for the change before mounting. Connection When the switch is used a in DC circuit, connect black lead wire to G, and white wire to F. Weight: 0.2kg PSMS-R2E1H Weight: 0.16kg PSMS-M215T Weight: 1.4kg PSMS-M450T Weight: 0.4kg Weight: 0.45kg Weight: 3kg PSMS-R3E1H PSMS-M325T PSMS-MX70T 77

MEMORY TYPE HIGH-TEMPERATURE-USE MAGNETIC PROXIMITY SWITCHES Stable Self-Holding Performance at High Temperature and Humid Atmosphere PSMM-H, T Resistant to continuous duty at 130 Simplified sequence circuit with no external self-holding circuit needed. RATINGS AND SPECIFICATIONS Switch Unit Magnet Unit Rated Sensitive Distance mm Incorporated Bestact Enclosure 3 Shock Resistance (Malfunction) 4 Vibration Resistance (Malfunction) Maximum Response Speed Insulation Resistance Cable 1 1 PSMM-M325T 25 PSMM-R3E1H PSMM-M450T 50 R15 250VAC (Power Frequency) 25 to +130 40 to +150 Waterproof type IP67 98m/s 2 {10G} 48m/s 2 {5G} (10 to 55Hz) 200m/min 5M or greater (with 500VDC Megger) 1500VAC for 1 minute, Leakage Current: 5mA (Across Open Contacts: 800VAC) 3m long heat-resistant cable (4.6mm outer dia, 0.75mm 2 2 conductors) PSMM-MX70T Operational Gap Range mm 10 to 35 10 to 60 10 to 85 Rated Insulation Voltage Ambient Operating Temperature Temperature Storage Withstand Voltage (Power Frequency) 4 Note: 1. Detectable distance at ambient temperature of 20 when both the switches and the magnet units are mounted on iron plates. Setting gap where ambient temperature T () can be calculated by the following equation. Setting gap (mm) =Rated sensitive distance {1-0.0018 (T-20) } 2. As for ratings and specifications other than tabulated above, refer to standard types on page 74. 3. Refer to page 59. 4. Values when the switch unit is mounted correctly on a non-magnetic material. These values can decline depending on mounting of a magnetic material and mounting direction. 70 TYPICAL APPLICATIONS Continuous casting machines, coke ovens, converters, rolling mills, cement cure ovens, equipment in refrigerators. MOUNTING Influence of ambient temperature and compensation Where temperature varies widely from the beginning and during operation, the actuating point and return point may change a little due to the thermal characteristics of the magnetic unit. For applications requiring higher accuracy, compensate for the change before mounting. Connection and Mounting When the switch is used in a DC circuit, connect black lead wire to G, and white wire to F. MG HORIZONTAL MOVEMENT 78 MG VERTICAL MOVEMENT

OPERATING CHARACTERISTICS (The switch unit is mounted on a non-magnetic material, and the magnet unit is on a ferromagnetic material.) (1) PSMM-M325T (2) PSMM-M450T (3) PSMM-MX70T Note: Shown here are typical examples. ON and OFF points vary depending on each product and mounting condition. Where the switch unit is mounted on a ferromagnetic material, the operating characteristics may change. DIMENSIONS in mm Weight: 0.4kg Weight: 0.45kg Weight: 1.6kg PSMM-R3E1H PSMM-M325T PSMM-M450T Weight: 2.5kg PSMM-MX70T 79

COLUMN TYPE MAGNETIC PROXIMITY SWITCHES PSMS-RV Superior Space/Cost Saving Performance Especially in High Temperature when Compared with Conventional Column Inductive Proximity Switches. PSMS-RV incorporating Bestact is best suited for position detectors in an adverse environment such as high temperature, high humidity or direct sunlight. Misalignment is allowed in all directions within the operating curve. The end user can adjust the mounting of the parts within the operating curve as needed. No power supply unit or amplifying relay needed. PSMS-RV1G1T RATINGS AND SPECIFICATIONS Purpose Switch Unit Magnet Unit Rated Sensitive Distance (mm) Contact Arrangement Rated Insulation Voltage Incorporated Bestact Contact Performance Characteristics Vibration Resistance Shock Resistance Erroneous Operation Breakdown Withstand Voltage (Power Frequency) General Purpose PSMS-RV1G1T PSMS-RV1G1TH PSMS-RV3G1TH PSMS-RV3G1THL PSMS-RV4G1THL PSMS-MV10TH (M6 STUD)PSMS-MV10THA (M8 SCREW) 10 1NO Refer to page 7. 98m/s 2 {10G} 980m/s 2 {100G} High Temperature 250VAC (Power Frequency) 49m/s 2 {5G} (16.7 to 1000Hz) 1500VAC for 1 minute, Leakage Current: 5mA (Across Open Contacts: 500VAC) Insulation Resistance Ambient Temperature Enclosure Unit Case Material Switch Unit Cable Operating Temperature Storage 10 to +60 20 to +80 General Cable 1m long 5M or greater (with 500VDC Megger) 25 to +130 30 to +130 Waterproof type IP67 Aluminum Heatproof Cable 1m long Note: Refer to page 59. TYPICAL APPLICATIONS Position detectors for an adverse atmosphere in steel plant/cement producing equipment Door-zone detectors for elevators Position detectors for escalators Position detectors for general industrial machinery like vertical parking garages Auxiliary contacts for heavy machinery like disconnectors 80

DRIVING METHOD AND SENSITIVE DISTANCE The magnet unit must be faced to the switch unit as shown in the below figure, and operating point must be set within the rated sensitive distance. DIMENSIONS in mm SWITCH UNIT PSMS-RV1G1T: with General Cable PSMS-RV1G1TH: with Heatproof Cable PSMS-RV3G1THL Weight: 120g PSMS-RV3G1TH PSMS-RV4G1THL Weight: 170g Weight: 250g MAGNET UNIT PSMS-MV10TH: M6 STUD PSMS-MV10THA: M8 STUD Contact Yaskawa for details about band mounting. NOTE FOR INSTALLATION CAUTION Tightening torque of the mounting nut Weight: 250g PSMS-RV1G1T (H) 16.6 to 23.5 (Nm) {170 to 240 (kgfcm)} PSMS-RV3G1TH (L) 49 to 78 (Nm) {500 to 800 (kgfcm)} Weight: 55g Note: where the switch is used in a DC circuit, connect the black lead wire to G and white lead wire to F. Do not twist the cable less than R50. 81