Input Current (Amps) Input Power (ANSI Watts)

Similar documents
Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts)

Input Power (Watts) (min/max)

Input Current (Amps) Input Power (ANSI Watts)

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

RELB2S40N35I (2)F40T12 120V Ele BLST

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

ICN2S40N35I Ele Ballast (2) F40T V

Input Power (Watts) (min/max)

High performance for high ceilings

Optanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS:

Reduce Maintenance Costs *

The New York University Concourse Project. New York City. Existing Electrical Conditions

1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS

Performance and Efficiency

Lighting The Way. Ballast Specification Guide

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts

Max. Input Power (W) Inrush Current (A pk /µs)

Compact SE Overview. High-Performance Dimming. Ballast

RZT2S54 Electr DMMG Ballast

Compact SE Overview. High-Performance Dimming. Ballast

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

FDBT S 32W120V DM Bal

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

Distribution Restriction Statement Approved for public release; distribution is unlimited.

EcoSystemR Multiple Control Input Ballasts

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

VEL2P75S35I 2-F96T12 277V Electronic Ballast

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube

QUICKTRONIC ICE Universal Voltage Systems

EcoSystem Multiple Control Input Ballasts

HIGH FREQUENCY ELECTRONIC BALLASTS

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast

OkSolar LED Outdoor Luminaires

EcoSystem Multiple Control Input Ballasts

Max. Input Power (W) Input Current V Isolated DALI

The sustainable choice. Optanium high-efficiency ballasts for today s T8 lighting needs

Quick Installation Guide. Affinium LED Modules LFM300 for Refrigerated Display Cases

Electronic Fluorescent Ballasts

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast

Section 3- Page --DCL With DEMANDflex Product Overview DemandFlex T DemandFlex T5, T5HO & TT DemandFlex T8 Wiring Diagram...

Max. Input Power (W) Input Current. Inrush 347V Vin 60/ C. 480V Vac Vin 85 / 115. Dimming Method.

Ballast Technology & Specification Guide SYLVANIA QUICKTRONIC Electronic Ballasts

BLADE TERMINAL AND SPECIAL PURPOSE FUSES

(2) PAR30 35MH/3000K + (2) AR111 75W/3000K (2) PAR30 70MH/3000K + (2) AR111 75W/3000K (2) 32WTBX/3000K (108) 40W HALOGEN G9 FROSTED

LED Modules. Fortimo DLM ES 0-10V G1 NA 1100lm

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies

Series A DC Link Chokes

ELECTRONIC FLUORESCENT BALLASTS

Energy Solutions LED Accelerator Program

Electrical Components. from Inter-Global

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

JOB NAME MODEL NO. LAMP OUTPUT VOLTAGE

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming

Controls. CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES

L I G H T W A V UV Electronic Ballast E 2010

MODEL 422 Submersible Pump Controller

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

MnDOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting Asymmetrical High Mast 04/19/18

DRIVER OUTPUT F Fixed DM 0-10v Dimming 1 COLOR TEMP 51K 5100

Certifications. Catalog. CFQ13W/G24q - 13W CFL Quad Tube Lamp (PL-C13W/4P, F13DBX/4P, CF13DD/E)

UL AND CODE COMPLIANCE

Photometric Outdoor Test Report

Skylark C L Dimmer. Skylark. Wallbox Controls. Dimmer for CFL and LED dimmable bulbs.

Locking-Type Mounting, Thermal Type K4500 Series

Nema Head We light your world

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

Lighting Electronics Atlas

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

HC HOLY CROSS HOSPITAL NORTH ADDITION

SPECIFICATIONS SRL CHARGER

Installation/Operating Instructions

ELECTRONIC FLUORESCENT BALLASTS

MOTOR PROTECTION Sine Wave 2-8 khz Series A Filter Table of Contents

ELECTRONIC FLUORESCENT BALLASTS

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

QCF IP65. LED Gas Canopy Fixture SPECIFICATIONS CERTIFICATION ORDERING INFORMATION EXAMPLE QCF-UL-60C-F-51K-GCO CERTIFIED

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE:

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

LED Modules. Fortimo DLM Flex L2

CLIMAGUARD Outdoor Heat Exchangers

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

TECHNICAL SPECIFICATIONS for. Telecommunication Battery Backup Systems (TBS)

Photoelectric Sensors 55 Series

GE Push Buttons. C-2000 Push Buttons. Push-to-Test Pilot Lights. Selection Process

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Max. Input Power (W) Input Current. Inrush. 277 Vin 7.4 / 600. Dimming Method. 1-10V Isolated. Enclosure

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

SPECIFICATIONS LOW COST 2404S CHARGER

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

Transcription:

Electrical Specifications ICN4S5490C2LSG@120 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 120-277 Input Frequency 50/60 HZ Status Active Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest F54T5/HO 1 54-20/-29 0.52 62 0.99 10 0.98 1.7 1.60 F54T5/HO 2 54-20/-29 0.99 118 0.99 10 0.98 1.7 0.84 F54T5/HO 3 54-20/-29 1.52 182 1.00 10 0.98 1.7 0.55 * F54T5/HO 4 54-20/-29 2.00 240 1.00 10 0.98 1.7 0.42 F54T5/HO/ES 3 44 5/-15 1.25 149 1.00 10 0.98 1.7 0.67 (44W) F54T5/HO/ES 4 44 5/-15 1.66 200 1.00 10 0.98 1.7 0.50 (44W) F54T5/HO/ES 1 49-20/-29 0.52 58 0.99 10 0.98 1.7 1.71 F54T5/HO/ES 2 49-20/-29 0.99 109 0.99 10 0.98 1.7 0.91 F54T5/HO/ES 3 49-20/-29 1.52 168 1.00 10 0.98 1.7 0.60 F54T5/HO/ES 4 49-20/-29 2.00 221 1.00 10 0.98 1.7 0.45 F58T8 1 58-20/-29 0.49 58 0.99 15 0.99 1.7 1.71 F58T8 2 58-20/-29 0.92 110 0.99 10 0.98 1.7 0.90 F58T8 3 58-20/-29 1.43 171 1.00 10 0.98 1.7 0.58 F58T8 4 58-20/-29 1.88 225 1.00 10 0.98 1.7 0.44 FT36W/2G11 1 36-20/-29 0.39 46 1.20 20 0.97 1.7 2.61 FT36W/2G11 2 36-20/-29 0.74 88 1.20 20 0.95 1.7 1.36 FT36W/2G11 3 36-20/-29 1.11 133 1.20 10 0.98 1.7 0.90 FT36W/2G11 4 36-20/-29 1.47 176 1.20 10 0.98 1.7 0.68 FT50W/2G11 1 50-20/-29 0.51 61 1.09 15 0.98 1.7 1.79 FT50W/2G11 2 50-20/-29 0.98 117 1.09 10 0.98 1.7 0.93 FT50W/2G11 3 50-20/-29 1.49 178 1.10 10 0.98 1.7 0.62 FT50W/2G11 4 50-20/-29 1.96 235 1.10 10 0.98 1.7 0.47 FT55W/2G11 1 55-20/-29 0.49 58 0.89 15 0.98 1.7 1.53 FT55W/2G11 2 55-20/-29 0.93 111 0.89 10 0.97 1.7 0.80 FT55W/2G11 3 55-20/-29 1.41 169 0.90 10 0.98 1.7 0.53 FT55W/2G11 4 55-20/-29 1.86 222 0.90 10 0.98 1.7 0.41 Wiring Diagram B.E.F. Revised 08/08/12 Data is based upon tests performed by Philips Lighting N.A in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. Philips Lighting Electronic N.A 10275 West Higgins Road Rosemont, IL 60018 Tel.: 800-322-2086 Fax: 888-432-1882 Customer Support/Technical Service: 800-372-3331 OEM Support: 866-915-5886

The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) in. cm. in. cm. Black 25 63.5 Yellow/Blue 0 White 25 63.5 Blue/White 33 83.8 Blue 28 71.1 Brown 28 71.1 Red 28 71.1 Orange 33 83.8 Yellow 28 71.1 Orange/Black 0 Gray 25 63.5 Black/White 0 Violet 0 Red/White 0 Enclosure Operates 2 or 3 lamps (A) GN BK WH SW o o GR 2 or 4 lamps (C) Same Input Wiring BALLAST OR BALLAST BL OR BLUE BL/WH Operates 1 or 3 lamps (B) Same BL/WH Input BALLAST Wiring (A) SW # Lamps ON ON 3 Lamps ON OFF 2 Lamps ON 1 Lamp ON BLUE (B) (C) # Lamps ON # Lamps ON 3 Lamps ON 4 Lamps ON 2 Lamps ON GN=Green BK=Black WH=White =Red GR=Grey OR = Orange BL=Blue =Brown =Yellow BL/WH=Blue/White

Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 16.7 " 1.7 " 1.18 " 16.34 " 16 7/10 1 7/10 1 9/50 16 17/50 42.4 cm 4.3 cm 3 cm 41.5 cm

Electrical Specifications Notes: ICN4S5490C2LSG@120 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 120-277 Input Frequency 50/60 HZ Status Active Section I - Physical Characteristics 1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable. 1.2 Ballast shall be provided with integral leads or poke-in wire trap connectors color-coded per ANSI C82.11. Section II - Performance 2.1 Ballast shall be Programmed Start. 2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power. 2.3 Ballast shall operate from 50/60 Hz input source of (120V through 277V, 347V or 347V through 480V) with sustained variations of +/- 10% (voltage and frequency). 2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 khz to avoid interference with infrared devices and eliminate visible flicker. 2.5 Ballast shall have a Power greater than 0.98 for primary lamp. 2.6 Ballast shall have a minimum ballast factor of 1.0 for primary lamp application. 2.7 Ballast shall provide for a Lamp Current Crest of 1.7 or less. 2.8 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp. 2.9 Ballast shall have a Class A sound rating. 2.10 Ballast shall have a minimum starting temperature of {-18C (0F) or -29C (-20F)} for primary lamp. Consult lamp manufacturer for temperature versus light output characteristics. 2.11 Ballast shall provide Lamp EOL Protection Circuit. 2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions. 2.13 Four-lamp ballast shall have (semi-independent or independent) lamp operation. Section III - Regulatory 3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB). 3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable. 3.3 Ballast shall comply with ANSI C62.41 Category A for Transient protection. 3.4 Ballast shall comply with ANSI C82.11 where applicable. 3.5 Ballast shall comply with applicable requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, for Non-Consumer equipment. 3.6 Ballast shall comply with UL Type CC rating. 3.7 Ballast shall comply with NEMA 410 for in-rush current limits. Section IV - Other 4.1 Ballast shall be manufactured in a factory certified to ISO 9001 Quality System Standards. 4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for operation at a maximum case temperature of 70C. Ballasts with a "90C" designation in their catalog number shall also carry a three-year warranty at a maximum case temperature of 90C. 4.3 Manufacturer shall have a twenty-year history of producing electronic ballasts for the North American market. Revised 08/08/12 Data is based upon tests performed by Philips Lighting Electronic N.A. in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. Philips Lighting Electronic N.A. 10275 West Higgins Road Rosemont, IL 60018 Tel.: 800-322-2086 Fax: 888-432-1882 Customer Support/Technical Service: 800-372-3331 OEM Support: 866-915-5886

Electrical Specifications ICN4S5490C2LSG@277 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 120-277 Input Frequency 50/60 HZ Status Active Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest F54T5/HO 1 54-20/-29 0.24 62 0.99 10 0.90 1.7 1.60 F54T5/HO 2 54-20/-29 0.43 117 0.99 10 0.98 1.7 0.85 * F54T5/HO 3 54-20/-29 0.66 179 1.00 10 0.98 1.7 0.56 F54T5/HO 4 54-20/-29 0.86 234 1.00 10 0.98 1.7 0.43 F54T5/HO/ES 3 44 5/-15 0.54 149 1.00 10 0.98 1.7 0.67 (44W) F54T5/HO/ES 4 44 5/-15 0.71 197 1.00 10 0.98 1.7 0.51 (44W) F54T5/HO/ES 1 49-20/-29 0.24 58 0.99 10 0.98 1.7 1.71 F54T5/HO/ES 2 49-20/-29 0.43 108 0.99 10 0.98 1.7 0.92 F54T5/HO/ES 3 49-20/-29 0.66 165 1.00 10 0.98 1.7 0.61 F54T5/HO/ES 4 49-20/-29 0.86 215 1.00 10 0.98 1.7 0.47 F58T8 1 58-20/-29 0.23 58 0.99 30 0.90 1.7 1.71 F58T8 2 58-20/-29 0.41 110 0.99 10 0.98 1.7 0.90 F58T8 3 58-20/-29 0.62 168 1.00 10 0.98 1.7 0.60 F58T8 4 58-20/-29 0.81 220 1.00 10 0.98 1.7 0.45 FT36W/2G11 1 36-20/-29 0.18 46 1.20 33 0.90 1.7 2.61 FT36W/2G11 2 36-20/-29 0.33 88 1.20 20 0.95 1.7 1.36 FT36W/2G11 3 36-20/-29 0.49 132 1.20 10 0.98 1.7 0.91 FT36W/2G11 4 36-20/-29 0.64 173 1.20 10 0.98 1.7 0.69 FT50W/2G11 1 50-20/-29 0.25 61 1.09 30 0.90 1.7 1.79 FT50W/2G11 2 50-20/-29 0.43 116 1.09 10 0.98 1.7 0.94 FT50W/2G11 3 50-20/-29 0.65 175 1.10 10 0.98 1.7 0.63 FT50W/2G11 4 50-20/-29 0.84 230 1.10 10 0.98 1.7 0.48 FT55W/2G11 1 55-20/-29 0.23 58 0.89 30 0.90 1.7 1.53 FT55W/2G11 2 55-20/-29 0.41 111 0.89 10 0.97 1.7 0.80 FT55W/2G11 3 55-20/-29 0.61 166 0.90 10 0.98 1.7 0.54 FT55W/2G11 4 55-20/-29 0.80 217 0.90 10 0.98 1.7 0.41 Wiring Diagram B.E.F. Revised 08/08/12 Data is based upon tests performed by Philips Lighting N.A in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. Philips Lighting Electronic N.A 10275 West Higgins Road Rosemont, IL 60018 Tel.: 800-322-2086 Fax: 888-432-1882 Customer Support/Technical Service: 800-372-3331 OEM Support: 866-915-5886

The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) in. cm. in. cm. Black 25 63.5 Yellow/Blue 0 White 25 63.5 Blue/White 33 83.8 Blue 28 71.1 Brown 28 71.1 Red 28 71.1 Orange 33 83.8 Yellow 28 71.1 Orange/Black 0 Gray 25 63.5 Black/White 0 Violet 0 Red/White 0 Enclosure Operates 2 or 3 lamps (A) GN BK WH SW o o GR 2 or 4 lamps (C) Same Input Wiring BALLAST OR BALLAST BL OR BLUE BL/WH Operates 1 or 3 lamps (B) Same BL/WH Input BALLAST Wiring (A) SW # Lamps ON ON 3 Lamps ON OFF 2 Lamps ON 1 Lamp ON BLUE (B) (C) # Lamps ON # Lamps ON 3 Lamps ON 4 Lamps ON 2 Lamps ON GN=Green BK=Black WH=White =Red GR=Grey OR = Orange BL=Blue =Brown =Yellow BL/WH=Blue/White

Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 16.7 " 1.7 " 1.18 " 16.34 " 16 7/10 1 7/10 1 9/50 16 17/50 42.4 cm 4.3 cm 3 cm 41.5 cm

Electrical Specifications Notes: ICN4S5490C2LSG@277 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 120-277 Input Frequency 50/60 HZ Status Active Section I - Physical Characteristics 1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable. 1.2 Ballast shall be provided with integral leads or poke-in wire trap connectors color-coded per ANSI C82.11. Section II - Performance 2.1 Ballast shall be Programmed Start. 2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power. 2.3 Ballast shall operate from 50/60 Hz input source of (120V through 277V, 347V or 347V through 480V) with sustained variations of +/- 10% (voltage and frequency). 2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 khz to avoid interference with infrared devices and eliminate visible flicker. 2.5 Ballast shall have a Power greater than 0.98 for primary lamp. 2.6 Ballast shall have a minimum ballast factor of 1.0 for primary lamp application. 2.7 Ballast shall provide for a Lamp Current Crest of 1.7 or less. 2.8 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp. 2.9 Ballast shall have a Class A sound rating. 2.10 Ballast shall have a minimum starting temperature of {-18C (0F) or -29C (-20F)} for primary lamp. Consult lamp manufacturer for temperature versus light output characteristics. 2.11 Ballast shall provide Lamp EOL Protection Circuit. 2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions. 2.13 Four-lamp ballast shall have (semi-independent or independent) lamp operation. Section III - Regulatory 3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB). 3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable. 3.3 Ballast shall comply with ANSI C62.41 Category A for Transient protection. 3.4 Ballast shall comply with ANSI C82.11 where applicable. 3.5 Ballast shall comply with applicable requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, for Non-Consumer equipment. 3.6 Ballast shall comply with UL Type CC rating. 3.7 Ballast shall comply with NEMA 410 for in-rush current limits. Section IV - Other 4.1 Ballast shall be manufactured in a factory certified to ISO 9001 Quality System Standards. 4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for operation at a maximum case temperature of 70C. Ballasts with a "90C" designation in their catalog number shall also carry a three-year warranty at a maximum case temperature of 90C. 4.3 Manufacturer shall have a twenty-year history of producing electronic ballasts for the North American market. Revised 08/08/12 Data is based upon tests performed by Philips Lighting Electronic N.A. in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. Philips Lighting Electronic N.A. 10275 West Higgins Road Rosemont, IL 60018 Tel.: 800-322-2086 Fax: 888-432-1882 Customer Support/Technical Service: 800-372-3331 OEM Support: 866-915-5886