Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.

Similar documents
Stryker Visum 300 Ceiling-Mounted Exam Light Assembly, Operations, and Maintenance Manual

Visum XBlade LED Exam Light. Operations Manual

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

354 Mobile Lighting System

Troubleshooting Guide: 355 Lights (12V)

AIM LED LIGHT (ceiling mount)

Oreck Magnesium Series Service Manual. The Oreck Manufacturing Company

ACROBAT SWING STAND MODEL

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

Operation Manual. 355 Lighting System. Safety 2. Features 4. Component Overview 5. Controls & Indicators 6. Operation 7.

Operation Manual. 354 / 355 Combination Lighting System MA475900

3875 Cypress Drive Petaluma, CA Fax

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

Operating Instructions. International English. CCS Dust Extractor

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

AIM LED LIGHT (wall mount)

Troubleshooting Guide: 355 Lights (24V)

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue

ALU-29CF Portable Light NSN:

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

OLYMPIAN MODEL 740 Operation and Service Manual

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

7.5 Oregon Fir With SYLVANIA Multi Color Mini Lights and Multi Color G50 Soft Glow Lights Pre-Lighted Tree V69139 INSTRUCTION MANUAL

Installation Manual 354 / 355 Combination Lighting System

INSTALLATION INSTRUCTIONS

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

Mounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

UV-AIRE AIR PURIFYING SYSTEM

SPECIALTY TOP CO. STC. INSTALLATION INSTRUCTIONS TOYOTA FAST TRAC Z TOP Toyota FJ PART #222-31X 82 1/8" 82 1/8"

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908

LED OPERATORY LIGHT Instructions For Use

Installation Manual. 355 Lighting System MA326100

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

1 AMP CURRENT SOURCE

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

MODEL G300 BRAKE BLEEDER

RETRACTABLE CEILING COLUMN

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

INSTALLATION AND SERVICE MANUAL

2100 Childbearing Bed OPERATIONS MANUAL. For Parts or Technical Assistance

SURGICAL POWER & ACCESSORIES. Rx Only PM-X00-710/PM-X IR-12.13

Installation Guide Philips MP2 IntelliVue M-Series Arm (12'' or 8'') Rail Mount Kit

STAND FOOT - STAND TUBE

Installation Manual for Philips Intellivue MP5/20/30 VHM-25 Channel Mount Kit

FD Conveyor for FD 260 Tabber

Xenon Fiberoptic Lightsource

axcs Operatory Light (Track, Ceiling, Wall and Cabinet Mount) Installation, Operation and Care Manual

Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+

I1 7.5 Pre-Lit Clear Christmas Tree

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

58kHz AM Deactivator DB104 Instruction Manual V1.0

Installation Manual for VHM-25 Series Arms Channel Mount

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

STAND MODEL FOR MACH M2

Model 605 Portable Aspirator

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

MotorScrubber MS2000S/M/L Instruction Manual

(Refer to qualified personnel)

SCAN OPTICS SO-161-R MICROSCOPE USER MANUAL

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge

USER MANUAL. EC+ Extra Care Bariatric Trauma Stretcher Model ConvaQuip Ind., Inc. P.O. Box 3417 Abilene, TX

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-10C/SS Power-Tip Systems

USER S GUIDE 2880 SERIES. 3 Safety Instructions. Product View. Assembly 4-5. Operation. Maintenance and Care. Troubleshooting.

Condor Manual. Corporation

Supertop Installation Instructions

Top Down Rollstar Shade Installation Instructions

The Da-Lite Difference.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Installation Manual. 355 Lighting System

LED-6200T 144 LED VARIABLE COLOR ON-CAMERA LIGHT USER MANUAL

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12DCE Task Force Deluxe Portable Pneumatic Dental System

INSTALLATION AND OPERATING INSTRUCTIONS

HLC CEILING MOUNTED DENTAL LIGHT. INSTALLATION and OPERATING INSTRUCTIONS. Rev.3

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

AXLE MOUNT MODELS: FILM ROLLER MODELS: OPERATING & SERVICE PARTS MANUAL TABLE TOP OVERWRAPPERS MODEL 625A MODEL 625A MINI MODEL 825A MODEL 875A

Installation Manual for Philips SureSigns VS3/VS4/VM4/VM6/VM8/VSV VHM-25 Countertop Mount

Fiber Optic Illuminator. Model 21AC Model 21DC

Rollstar Shade Installation Instructions

Retrofit Steering Column

ACROBAT SWING STAND MODEL

OWNER S MANUAL & WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS

FAN POWERED HEPA FILTER UNIT

Mustang Clear Lens Instrument Cover (90-93) - Installation Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

##CFG BWOP Manuals## Quasar elite HD-LED Mobile Models Assembly Guide

GCX Mounting Assembly Installation Guide. Philips MP90 (M8010A) Mounting Kit for Drager Zeus

Installation Manual. 354 / 355 Combination Lighting System MA475900

LED-6200T 144 LED VARIABLE COLOR ON-CAMERA LIGHT USER MANUAL

ATV TRACK KIT. Operator s Manual Installation Instructions Service Instructions Replacement Parts List. Effective Date: October, 2012

MotorScrubber MS2000S/M/L Instruction Manual

IMPORTANT SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS 1

Spotlight 1,000,000 Power Series Cordless Rechargeable

Transcription:

Operations/ Maintenance Manual Important Information File in your maintenance records Medical Visum Exam Light Model LL305 For parts or technical assistance call 800 327 0770 (option 2)

Table of Contents Introduction Intended Use............................................................................ 2 Operating Mode......................................................................... 2 Warning / Caution / Note Definition.......................................................... 2 Safety Tips and Guidelines................................................................... 3 Symbols................................................................................... 4 Specifications.............................................................................. 5 Electrical Schematic......................................................................... 6 Light Assembly, Overview.................................................................... 7 Mounting the Casters..................................................................... 8 Mounting the Stand....................................................................... 9 Mounting the Light Head................................................................. 10 Attaching the Light Handle Assembly....................................................... 11 Operations Adjusting the Light Head................................................................. 12 Moving the Light........................................................................ 13 Preventative Maintenance Preventative Maintenance Checklist........................................................ 14 Cleaning and Disinfection................................................................. 15 Troubleshooting......................................................................... 16 17 Service Information Setting the Spring Force................................................................. 18 Attaching/Removing the Sterilizable Light Handle Cover....................................... 18 Changing the Halogen Light Bulb Replacing the Aesthetics Kit.................................................................................................................. 19 20 20 22 Replacing the Electrical Kit............................................................. 22 24 Replacing the Transformer............................................................. 25 27 Greasing the Keeper Clip................................................................. 27 Replacement Parts...................................................................... 28 32 Warranty................................................................................. 33

Introduction Introduction Whether in the doctor s office, examination rooms, emergency facilities, intensive care clinics, pre or post operative rooms, the Stryker LL305 Visum Examination Light provides high intensity light wherever it s needed. Outstanding features of this light include the unique shape of the lamp housing, the combination faceted and parabolic technology of its reflector, and its smooth operating and spring loaded articulating arm. Highlights of the Examination Lamp: Smooth operation and adjustability Precise positioning Compact and enclosed articulation system with counterbalance system. A specially designed reflector system to ensure a precise light source that renders true colors. Intended use: Examination light for use in the patient s surroundings, to illuminate the body of the patient locally to support diagnosis or treatment. It has not been designed as a surgery light or for use by the patient. Operating Mode: This light is designed for continuous service. Warning / Caution / Note Definition The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed. WARNING The personal safety of the patient or user may be involved. Disregarding this information could result in injury to the patient or user. CAUTION These instructions point out special procedures or precautions that must be followed to avoid damaging the equipment. NOTE This provides special information to make maintenance easier or important instructions clearer. 2

Safety Tips and Guidelines WARNING Maintenance must be performed by qualified service personnel. Always verify the power cord is unplugged from the wall outlet before performing service. The Stryker LL305 Visum Examination Light is equipped with a hospital grade plug for protection against shock hazard. It must be plugged directly into a properly grounded three prong receptacle. Grounding reliability can be achieved only when a hospital grade receptacle is used. For use only in dry rooms not subject to risk of explosion. Maintain a distance of at least 24 inches between the patient and the light head. Maintain a distance of at least 24 inches from flammable objects when operating the light. Do not leave the light unattended while in operation. The light is hot while in operation. Do not touch the protective glass, reflector, or bulb while the light is turned on or immediately after turning it off. Allow the light to cool before attempting maintenance. Do not operate the light if any components are damaged. When replacing the halogen light bulb, use only the bulb specified in this manual. Use only manufacturer approved replacement parts. Do not add additional weight on the Exam Light. Do not place items on or over the hood of the Exam Light. Do not look driectly into the Exam Light while powered on. CAUTION Potential electromagnetic interference can cause steady, momentary, or intermittend disruption of medical devices. Prevent known sources of interference (i.e cell phones) from coming too close to patient monitors and other medical devices. 3

Symbols and Definitions Warning, Refer to Operations / Maintenance Manual Risk of burns. Hazardous Voltage. Explosion Hazard. Oxygen forms explosive mixtures with oils, grease and lubricants. The presence of oxygen presents an explosion hazard. Medical Equipment Classified by ETL with Respect to Electric Shock, Fire, Mechanical and Other Specified Hazards Only in Accordance with UL 60601 1 and CAN/CSA C22.2 No. 601.1 4

Specifications Fitted with: Luminous power Ec Illuminated field size 30 inches (.8 m) distance D10 Color temperature Color rendering index, central light field size, light field ø 92 1 halogen bulb 12V/ 50W approximately 3484 ft. candle (37,500 Lux) = 6.8 (17 cm) approximately 3978 K Supply voltage 115 VAC, 60Hz,.5A Power Cord Net weight Power consumption 15 feet with hospital grade plug approximately 55.6lbs (25.3kg) approximately 60VA Environmental Conditions Operation Storage and Transportation Temperature 10 40 degrees C 20 40 degrees C Relative Humidity 30% 75% 10% 75% Protection class I (with hospital grade plug) Standards IEC 60601 2 41, IEC 60601 1 2, IEC 60601 1 CAN/CSA C22.2 No. 601.1 M90, UL 60601 1 5

Electrical Schematic Visum 300 Electrical Schematic 6

Assembling the Light Examination Light: Part Number 8500 000 001 Light Head Assembly Elbow Light Handle Assembly Stand and Spring Arm Assembly Handle for Stand Transformer Base Caster 7

Assembling the Light Mounting the Casters CAUTION Static Charge If the grounding cable is not installed, the mobile stand may get statically charged and the charge may get transferred to the user. Install the grounding cable. 1. Open the packaging of the base so that the bottom is upside down on the floor or bench. 2. Make sure the grounding cable is installed as shown in Figure 1. There are two grounding cables per base. Figure 1. Proper positioning of grounding cable. 3. Guide the caster through the ring cable lug of the grounding cable and into the base. Press in firmly until the caster is snug. (Figure 2) Figure 2. 4. Repeat for the other grounding cable and caster assembly. 5. Completely insert the two other casters into the base. 6. Check for firm seating of the casters by turning base over and pressing down firmly on each corner. 8

Assembling the Light Mounting the Stand Tools Required: Slip Joint Pliers WARNING When unpacking the Spring Arm, do not cut the tape right away. Assemble the stand to the base first. Hold onto the Spring Arm prior to cutting the tape to prevent sudden release. Failure to do do may cause injury to the user. Note where the locking key feature is located inside the base. (Figure 3) Keyhole 1 Keyhole 2 Figure 3. 1. Remove the stand and position the key hole on the stand so that it aligns with keyhole 1 of the base and inset until the stand is fully seated. (figure 4) Keyhole Figure 4. 2. Locate the wing screw from the accessory bag and insert it through the bottom of the stand. Turn the wing screw by hand until the screw is fully threaded and finger tight. Using slip joint pliers, turn the wing screw one full rotation. (Figure 5) Figure 5. 9

Assembling the Light Mounting the Light Head Tools Required: Regular Screwdriver 1. Using a regular screwdriver, remove the brake screw at the end of the spring arm as shown in Figure 6 and set aside for later use. Remove the white plastic cap from the spring arm. Rotate the locking cover 180 degrees in either direction so that the keeper slot is exposed. Figure 6. 2. Align the end of the light head to the end of the spring arm and push together until fully seated. (Figure 7) Figure 7. 3. Place the keeper clip from the accessory bag into the fitted slot and push down until the clip is flushed with the arm. (Figure 8) Figure 8. 4. Rotate the locking cover 180 degress in either direction until the brake opening is faced down. (Figure 9) Figure 9. 5. Using a regular screwdriver, insert the brake screw into the brake opening and check to make sure assembly of light head is secure. (Figure 10) 10 Figure 10.

Assembling the Light Attaching the Light Handle Assembly 1. Position the system as shown in Figure 11. Figure 11. 2. Lock the system into position by pressing down the tab on the end of each roller. (Figure 12) Figure 12. 3. Connect the light bulb into the socket of the light handle assembly. (Figure 13) Figure 13. 4. With one hand on the light handle assembly and one hand on the back of the light head, carefully insert the light handle assembly into the light head. Align the banana clips to the power receptacles and the screws to the threaded holes as shown in figure 14. Screw the two thumbscrews until fully seated. 11 Figure 14.

Operations Guide Adjusting the Light Head The light can be used with or without a sterilizable handle. Position the light in the following manner. 1. 360 degrees of rotation. (Figure 15) Figure 15. 2. 180 degrees of rotation. (Figure 16) Figure 16. 3. 90 degrees of rotation. (Figure 17) Figure 17. 4. 60 degrees of rotation (Figure 18) Figure 18. 12

Operations Guide Moving the Light Before moving the light, put the light head down to its lowest position. Make sure the casters are released from locked position. NOTE It is important to move the light only by the handle on the stand. CAUTION Instruction Do not push, or pull the stand in any other areas other than the handle on the stand, otherwise tipping of the stand may occur. Turning On and Off 1. Light is shown in the Off position. (Figure 19) Figure 19. Locking the Exam Light 1. To lock the exam light into position, simply press down the tab on the end of each caster. (Figure 20) Figure 20. 13

Preventative Maintenance WARNING Maintenance must be performed by qualified service personnel. Always verify the power cord is unplugged from the wall outlet before performing service. The Stryker LL305 Visum Examination Light is equipped with a hospital grade plug for protection against shock hazard. It must be plugged directly into a properly grounded three prong receptacle. Grounding reliability can be achieved only when a hospital grade receptacle is used. The light is hot while in operation. Do not touch the protective glass, reflector, or bulb while the light is turned on or immediately after turning it off. When replacing the halogen light bulb, use only the bulb specified in this manual. Allow the light to cool before attempting maintenance. Do not touch the glass surface of the either the old or the new bulb. Use a soft cloth to remove the old bulb and install the new one Use only manufacturer approved replacement parts. Preventative Maintenance Checklist Preventative maintenance should be performed at a minimum of annually. All fasteners secure on the lamp head and column All casters secure and swivelling properly Casters lock properly Power cord not frayed On/Off switch functions properly Ground impedance not more than 100 milliohms Current leakage not more than 300 microamps Verify the spring force of arm and light head are proper. Lubricate keeper clip. 14

Preventative Maintenance Cleaning And Disinfecting NOTE Qualifications of the personnel: Cleaning and disinfecting must only be carried out by trained personnel. WARNING Electrical Shock For all cleaning work, power off equipment, disconnect power cord from outlet. Take care that no fluid runs into the equipment. CAUTION Damage to the product: To avoid damage to plastic parts, do not use scouring agents, alkali, acidic or alcohol containing cleaning agents. Do not use disinfectant alcohol. Cleaning Turn the light off Disconnect from power outlet Wipe the surfaces with a lightly moistened piece of cloth, if required, add a mild solution of soap (washing agent). Disinfecting Disinfect the equipment only when it is cool. Sterile Handle NOTE The handle can easily be removed for cleaning or sterilization. CAUTION Handles are shipped non sterile. Please clean and sterilize the handles prior to use. Cleaning Rinse handle under running lukewarm water, flushing water through all passages. Submerge entire handle in an enzyme action detergent prepared according to the manufacturer s recommendations. Remove debris and bioburden from all surfaces using a soft brush. Rinse handle thoroughly under running lukewarm water, flushing water through all passages. Dry handle with a lint free cloth. Inspect handle to make sure it is free of debris. Sterilization The following sterilization methods have been validated: Gravity Displacement Steam sterilization(single wrapped) Temperature: 132 degrees C (270 degrees F) Exposure Time: 10 minutes Gravity Displacement Steam sterilization (double wrapped) Temperature: 121 degrees C (250 degrees F) Exposure Time: 25 minutes Pre Vacuum Cycle (double wrapped) Temperature: 134 degrees C (273 degrees F) Exposure Time: 4 minutes 15

Troubleshooting Guide Light is not working Yes Check the bulb No Replace Bulb. Yes for continuity. ref. pg. 23 24 Yes Is there 115V at the brown and blue wires coming into the terminal block in the handle No Replace Power Cord. ref. pg. 26 28 Yes Test the Light for functionality. assembly? Yes Yes Return Light to Service. Check continuity of the 1A fuses at the terminal block in the handle assembly. No Replace Fuse. ref. pg. 28 Yes ref. pg. 26 27 Yes A 16

Troubleshooting A If problem still exists, please contact Stryker Technical Support at 1 800 327 0770 (option 2). Check for 115V at the violet and black wires coming into the transformer. No Replace the Stand Assembly. Yes ref. pg. 29 30 Yes Check for 14 VAC on the red wires coming out of the transformer. No Replace the Transformer. Yes Test the Light for Yes functionality. Check for 14 VAC at the commutator. No Replace the Stand Assembly. Yes Yes Return Light to Service. Yes Check Light Handle Assembly. No Replace the Light Handle Assembly. Yes 17

Service Information Setting the Spring Force Tools Required Regular Screwdriver CAUTION Instruction Make sure to lock the casters before adjusting the spring tension. NOTE Adjust the spring force such that the spring arm with the light head assembly does not drift when placed in any desired position. 1. Pull off the elbow cap as shown in Figure 21. Figure 21. 2. Using a regular screwdriver, turn the knob shown until the desired tension is reached. (Figure 22) NOTE If the spring arm drops, the spring force is too low and the screw must be rotated counter clockwise. If the spring arm rised, the spring fcrce is too high and the screw must be rotated clockwise. Attaching/Removing the Sterilizable Light Handle Cover Figure 22. 1. To remove the optional sterilizable handle, press the metal button and pull down on the handle. To attach the handle, align the locking tab feature on the light handle assembly and the optional sterilizable handle. Slide the handle onto the light handle assembly and twist until the button secures the sterilizable handle into place. A locking click will be heard when secured. (Figure 23) 18 Figure 23

Service Information Changing the Halogen Light WARNING High Temperature Allow the light to cool before attempting maintenance. The light is hot while in operation. Do not touch the protective glass or bulb while the light is turned on or immediately after turning it off. CAUTION Instruction If the optional sterile handle is on the light handle assembly, remove the sterile handle first (refer to section Attaching/Removing the Sterilizable Light Handle Cover). Only use the bulb specified in the Spare Parts section. The use of a bulb other than the one specified may result in poor color reproduction or higher operating temperatures. 1. Turn off the light and disconnect from the power outlet. Set the braking mechanism on the casters. For easy access, place the light head in the position as shown in Figure 24. Figure 24. 2. Unscrew the two thumbscrews simultaneously until the screws spin freely without resisitance. Carefully pull the light handle assembly straight out. (Figure 25) Figure 25. 3. Firmly grasp the bulb and pull straight out to remove it. Connect the replacment bulb into the socket of the light handle assembly. (Figure 26) 19 Figure 26.

Service Information Changing the Halogen Light (continued) 1. With one hand on the light handle assembly and one hand on the back of the light head, carefully insert the light handle assembly into the light head. Align the banana clips to the power receptacles and the screws to the threaded holes as shown in Figure 27. Screw the two thumbscrews until fully seated. Figure 27. Replacing the Aesthetics Kit Tools Required Regular Screwdriver Regular Screwdriver (small tip for removing Keeper Clip) Phillips Head Screwdriver Snap Ring Pliers (supplied) 1. Turn off the light and disconnect from the power outlet. Remove the brake screw at the end of the spring arm as shown in Figure 28. Set aside for later use. Figure 28. 2. Rotate the brake cover 180 degrees and remove the keeper clip. Remove the light head and set aside for later use. Remove brake cover from the end of the spring arm. (Figure 29) NOTE: If replacing brake cover only, then install new brake cover and do not proceed to following steps. Figure 29. 20

Service Information Replacing the Aesthetics Kit (continued) 3. Remove the top end cap by removing the small screw. If replacing top end cap only, install new end cap and do not proceed to following steps. (Figure 30) Figure 30. 4. Remove elbow caps. (Figure 31) Figure 31. 5. Pull the cables out from the spring arm and disconnect the cables. (Figure 32) Figure 32. 6. Using the supplied snap ring pliers, remove the snap ring from the spriong arm. Remove the flat washer and pull the spring arm from the stand. (Figure 33) Figure 33. 21

Service Information Replacing the Aesthetics Kit (continued) 7. Remove the elbow collars by sliding them off of the spring arm. Slide new collars into place. Reassemble the spring arm following steps in reverse order. Place new elbow caps on if required. (Figure 34) Figure 34. 8. Slide the elbow cover completely off by removing the grounding screws shown in Figure 35 and the brake cover from the end of the spring arm. Replacing the Electrical Kit Figure 35. Tools Required Regular Screwdriver (small tip) Phillips Head Screwdriver Torx Screwdriver WARNING Electrical Shock Disconnect from power outlet to prevent electriclal shock. Figure 36. 1. Turn off the light and disconnect it from the power outlet. Using a Torx Screwdriver, remove the two screws from the handle as shown in Figure 36. 2. Pull handle apart as shown in Figure 37. Figure 37. 22

Service Information Replacing the Electrical Kit (continued) 3. Remove the screws to release cord. (Figure 38) Figure 38. 4. Loosen the three screws from the fuse holder to release the cord entirely from the handle. (Figure 39) Figure 39. 5. The Electrical Kit comes with an extra connector and fuse holder. If replacing the handle and/or fuse holder, remove the screw holding the fuse holder in. Loosen the screws holding the wires to the fuse holder if replacing with a new fuse holder. (Figure 40) Figure 40. 6. Insert the line wire (brown) through the fuse holder and the neutral wire (blue) through the other connection. Insert the ground wire (green/yellow) through the connector. (Figure 41) 23 Figure 41.

Service Information Replacing the Electrical Kit (continued) 7. Attach the fuse holder to the stand. Insert two 1 amp fuses into the fuse holder as shown in Figure 42. Figure 42. 8. Secure power cord with the strain relief and two screws. (Figure 43) Figure 43. 9. Place the new handle on and ensure the two extrusions fit into the two openings of the stand. The cord should be coming down. Snap back into place and screw handle together. (Figure 44) Figure 44. 24

Service Information Replacing the Transformer Tools Required Regular Screwdriver (small tip) Phillips Head Screwdriver Phillips Head Screwdriver (small tip) 2mm Allen wrench WARNING Electrical Shock Disconnect from power outlet to prevent electriclal shock. Figure 45. 1. Turn off the light and disconnect it from the power outlet. Remove the brake screw at the end of the spring arm as shown in Figure 45. Set the brake screw aside for later use. Figure 46. 2. Rotate the brake cover 180 degrees and remove the keeper clip. Remove the light head. (Figure 46) 3. Remove the wing screw from the bottom of the stand. Pull off the stand from the base. (Figure 47) Figure 47. 4. Place the stand on a flat surface on a piece of cardboard or cloth to prevent surface damage. Remove the two small screws from the collars as shown in Figure 48. Detach the collars. Figure 48. 25

Service Information Replacing the Transformer (continued) 5. Remove the two side screws on the transformer cover. Once removed, push the cover up towards the spring arm to expose the transformer. (Figure 49) 6. Unscrew the grounding cable from the stand. (Figure 50) Figure 49. 7. Loosen the three screws on the top plate of the transformer with an Allen wrench. Ensure the screws are not exposed on either end. There should be enough space in the top plate for the screw to remain inside the plate. (Figure 51) Figure 50. 8. Disconnect the wires from the connector as shown in Figure 52. Refer to wiring diagram below. Connection for 115V Black Red Figure 51. 115 VAC Primary Orange 14 VAC Secondary White Violet Red Figure 52. 26

Service Information Replacing the Transformer (continued) 9. Carefully slide the top plate and the top rubber grommet up around the wires. Slide the transformer and the bottom rubber grommet up afterwards. (Figure 53) Figure 53. 10. Using a Phillips screwdriver, remove the screw that holds the bottom plates together. (Figure 54) Figure 54. 11. Pull apart the bottom plates from the stand. Slide the transformer and the bottom grommet off of the stand. If installing a new transformer cover, slide the top plate, top grommet, and existing cover off. Slide the new cover on, followed by the top plate and the top grommet. If installing a new transformer, slide new transformer on. Place bottom grommet on, re attach bottom plates, and put back together using steps above in reverse order. (Figure 55) Figure 55. Greasing the Keeper Clip 1. Dismantle the light head. 2. Check the keeper clip for a minimum thickness of 1.5 mm and if required, replace it. 3. Grease the keeper clip and the pin of the light head. 4. Assemble the light head. 27

Replacement Parts Replacement Parts For the following or any other replacement parts, please contact Stryker Customer Service at 1 800 327 0770 (Option 1). Dispose of all removed light bulbs and parts in accordance with local regulations. 8500 000 010................ Light Handle Assembly 8500 000 009................ Sterile Handle Qty = 3 8500 000 008................ Light Bulb Qty = 5 8500 000 011................ Hardware Kit Wing Screw Brake Screw Keeper Clip 28

Replacement Parts Replacement Parts (continued) 8500 000 007................ Anti Static Casters Qty = 4 Elbow Caps 8500 000 012................ Aesthetics Kit Brake Cover Top End Cap Handle for Stand Medical Grade Cord 8500 000 013................ Electrical Kit Fuse Holder Fuse Qty = 2 29

Replacement Parts Replacement Parts (continued) 8500 000 006................ Transformer Cover 8500 000 005................ Transformer, 115V 8500 000 004................ Fuse, 1 Amp Qty = 5 Pack 8500 000 060................ Spring Arm with Brake Cover 30

Replacement Parts Replacement Parts (continued) 1 Base 8500 000 030................ Base Assembly 4 Anti Static casters with brakes 1 Light Handle Assembly 8500 000 050................ Light Head Assembly 1 Light Bulb 1 Light Head 31

Replacement Parts Replacement Parts (continued) 1 Spring Arm with Brake Cover 1 Stand with handle, top end cap, transformer, and transformer cover. 8500 000 040................ Spring Arm Assembly 1 Keeper Clip 1 Snap Ring Pliers 1Wing Screw 1 Brake Screw 1 Flat Washer 1 Snap Ring 32

Troubleshooting Warranty Stryker warrants that its Examination Lights are warranted against defective materials and workmanship for two years from the date of purchase. Warranty applies to normal usage and does not apply to any product that has been subject to alteration, abuse, negligence or use (including voltage and/or current) other than that for which the product was designed. This warranty is limited to replacement, repair or refund at Stryker s option. Lamps (bulbs) are not covered by this warranty. 33

3800 E. Centre Ave, Portage, MI 49002 (800) 327 0770 www.stryker.com JH 4/06 8500 009 001 REV D