Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * ) Energy Trust offers cash incentives to help you implement approved energy efficient lighting measures. If you are interested in applying for these incentives, then contact us today using the information at the bottom of the page for application information or visit our website at www.energytrust.org. Lighting projects must be reviewed and pre-qualified to apply for Energy Trust incentives. It is important that you contact us and take all required steps for incentive application pre-qualification prior to beginning any equipment purchase or installation activities that may disqualify your project from receiving incentives. Lighting Project Specifications & Requirements The following lists provide technical specifications for certain lighting products. Not all products listed qualify for Energy Trust incentives. To qualify for incentives, products must also pass Energy Trust cost-effectiveness criteria and meet other program requirements: See http://www.cee1.org/com/com-lt/lamps-ballasts.xls or http://library.cee1.org/content/reduced-wattage-t8- specification for CEE High-performance and Reduced Wattage 4' T8 Lamp and Ballast Qualifying Lists See the following Qualified Product Lists (QPL) for each category of LED product: o QPL for LED fixtures (except recessed canister downlights) - Design Lights Consortium (DLC): http://www.designlights.org/qpl o QPL for LED recessed canister downlights & other (Certified Light Fixtures) ENERGY STAR : http://www.energystar.gov/productfinder/product/certified-light-fixtures/ o QPL for LED lamps (Certified Light Bulbs) ENERGY STAR : http://www.energystar.gov/productfinder/product/certified-light-bulbs/ Alternate QPL for LED lamps, fixtures, and downlights Lighting Design Lab (LDL): https://www.lightingdesignlab.com/led-qualified-products-list-and-submission The following requirements apply to lighting projects: Ballast or driver and lamp combinations must be compatible. Lighting projects must have a simple payback (without incentives) of at least one year. Lighting projects must qualify for at least $100 in incentive funding in order to apply for Energy Trust incentives. All submitted projects are subject to an Energy Trust review, which will look at the measures in relation to Illuminating Engineering Society (IES) recommendations for minimum light levels and appropriate ratios for the customer s space type and functions. If light levels appear to meet minimum IES recommendations and the specified lighting wattages exceed the measure specifications listed below, Energy Trust will make the final determination as to whether a specified measure qualifies for prescriptive incentives (as listed below) or custom incentives. TLED: Trade ally (or installer) must verify the conditions of existing lampholders and replace damaged, corroded, and/or cracked lampholders. External Driver TLED versions: labeling is recommended to indicate the fixture has been retrofitted with a TLED and fluorescent lamps should not be installed as replacements. Internal Driver TLED versions: must affix a label in a prominent location on the interior of the fixture in compliance with UL requirements. The label must indicate the fixture has been retrofitted with a TLED and fluorescent lamps should not be installed as replacements. The maximum incentive provided by Energy Trust for any custom lighting incentive will never exceed 25 per kwh saved or 50% of total eligible line item cost. Additional requirements may apply. Contact us for details. * Subject to change without notice Program Information 190L v2015.2 150701 Page 1 of 5
Section 1 Fluorescent Fixture to New LED Fixture or Fixture Retrofit Kit (tombstones are removed; Non-TLED) Example application: Replace four-lamp T12 recessed troffer with 60 watt LED troffer fixture Two-lamp 2 U-bent T12 to LED fixture, 36 watts or less $ 25 per fixture Two-lamp 4 T12 to LED fixture, 36 watts or less $ 31 per fixture Three-lamp 4 T12 (or T8) to LED fixture, 45 watts or less $ 42 per fixture Four-lamp 4 T12 (or T8) to LED fixture, 60 watts or less $ 45 per fixture Two-lamp T8 to 2 x2 or 1 x4 LED recessed fixture with high performance volumetric lens, over 100 lumens/watt, and 25 watts or less. $ 60 per fixture Two-lamp T8 to 2 x4 LED recessed fixture with high performance volumetric lens, over 100 lumens/watt, and 25 watts or less. $ 75 per fixture T12 (or three- or four-lamp T8) to 2 x2 or 1 x4 LED recessed fixture with high performance volumetric lens and over 100 lumens/watt. $ 60 per fixture T12 (or three- or four-lamp T8) to 2 x4 LED recessed fixture with high performance volumetric lens and over 100 lumens/watt. $ 75 per fixture Additional incentives available for qualifying LED fixtures connected to controls and dimming devices See section 11 LED products not listed here may qualify for custom incentives if they meet certain criteria. See Section 12 for information about custom incentives. Volumetric definition: minimum of 15% of the zonal lumens between 60 and 90 degrees, without high glare at the lower angles. Projects will be reviewed to verify whether light levels appear to be appropriate for the proposed space in accordance with program requirements. See Section 2 & 3 for Tube LED retrofit kits. Section 2 Existing 4-Foot T12 Fluorescent Fixture (Retrofit Options) Example application: Four-lamp T12 recessed troffer to two-lamp 32 watt CEE qualified T8 high performance lamps and ballast troffer retrofit A. Lamp and ballast retrofits (existing ballast must be removed or replaced): T12 to TLED lamp-for-lamp retrofit with new T8 ballast or external or internal LED driver (1) $ 10 per lamp (1) Delamping combination; incentive based on number of lamps installed before project T12 three-lamp to three 25 or 28 watt T8 CEE lamps and low ballast factor ballast $ 20 per fixture T12 four-lamp to four 25 or 28 watt T8 CEE lamps and ballast $ 20 per fixture T12 three-lamp to two T8 CEE lamps and ballast (2) $ 25 per fixture T12 four-lamp to three T8 CEE lamps and ballast (2) $ 25 per fixture T12 four-lamp to two T8 CEE lamps and ballast (2) $ 30 per fixture (2) When using 25 or 28 watt T8 CEE lamps on delamping combinations above $ 6 fixture B. Fixture upgrade/kits (conversions): T12 three or four-lamp to two reduced wattage CEE lamps (25 or 28 watt), fixture or kit, with low ballast factor ballast and high-performance lens kit (fixture efficiency 80%) $ 42 per fixture T8 lamp must be CEE qualified; TLED products must be QPL listed and meet DLC minimum requirements (existing T12 ballast removed or replaced). Program Information 190L v2015.2 150701 Page 2 of 5
Section 3 Existing 4-Foot T8 Fluorescent Fixture (Retrofit Options) Example application: Three-lamp T8 recessed troffer to two-lamp CEE qualified 28 watt T8 recessed troffer with CEE qualified low ballast factor ballast A. Lamp and ballast retrofits (existing ballast must be removed or replaced): T8 to TLED lamp-for-lamp (22 watt or less lamp) and new T8 ballast or external or internal LED driver type (1) $ 8 per lamp (1) Delamping TLED (22 watt or less lamp); incentive based on number of lamps installed before project Four-lamp T8 to four reduced wattage (25 or 28 watt) T8 CEE lamps and low ballast factor ballast B. Fixture upgrade/kits (conversions): T8 three or four-lamp to two reduced wattage T8 CEE lamps (25 or 28 watt) with low ballast factor ballast & reflector T8 three or four-lamp to two reduced wattage T8 CEE lamps (25 or 28 watt), fixture or kit, with low ballast factor ballast and high-performance lens kit (fixture efficiency 80%) $ 15 per fixture $ 25 per fixture $ 42 per fixture T8 lamp must be CEE qualified; TLED products must be QPL listed and meet DLC minimum requirements. TLED with existing T8 ballast, see section 6. Section 4 Existing 2-Foot U-Bent Fluorescent Fixtures or Pin-Base CFL Fixtures (Retrofit Options) * Example application: Replace two T8 U-bent lamps and ballast in a 2 x 2 recessed troffer with two-18w TLED U-bent lamps and new external LED driver (i.e. fluorescent ballast removed) T8 Existing: 2 U-bent to TLED kit/fixture retrofit with new T8 ballast or external or internal LED driver type $ 8 per lamp T12 Existing: 2 U-bent to TLED kit/fixture retrofit with new T8 ballast or external or internal LED driver type (1) $ 10 per lamp (1) Delamp T12 or T8 to TLED kit/fixture retrofit Pin-base CFL to LED kit (replacing CFL Hardwire type), removes fluorescent ballast $ 4 per lamp T8 Ballast versions: must replace with new electronic ballast or driver; see section 6 for leaving existing ballasts with TLED lamps. TLED products must be QPL listed and meet DLC minimum requirements. Section 5 Existing 8-Foot Fluorescent Lamp Fixture (Retrofit Options) Example application: 8' two-lamp T12 strip fixture to 8 two-lamp TLED kit with ballast removed. T8 Existing: 8 fixture to 8 TLED Kit/Fixture (remove or replace existing ballast) (1) $ 16 per lamp T12 Existing: 8 fixture to 8 TLED Kit/Fixture (1) $ 20 per lamp T12 Existing: 8 fixture to 4 TLED Kit/Fixture (1) $ 10 per lamp T8 Existing: 8 fixture to 4 TLED Kit/Fixture (remove or replace existing ballast) (1) $ 8 per lamp (1) Delamping TLED combinations above; incentive count based on existing lamps first 8 Fluorescent combinations See custom section 12 TLED requires new T8 ballast or external or internal LED driver. TLED products must be QPL listed and meet DLC minimum requirements. Lamp lengths not reviewed by DLC must meet Energy Trust QPL policy requirements. * Mock-up for participant approval may be required to determine appropriate aesthetics, distribution, and light quality. Program Information 190L v2015.2 150701 Page 3 of 5
Section 6 Relamp Only: Existing Linear Fluorescent Fixture (no ballast change out required): Example application: 4 fixture w/32-watt T8 lamps replacing w/28-watt CEE T8 lamps only (1-for-1). No ballast change out. T5HO fixture with 54 watt lamps to 47-51 watt lamps $ 2 per lamp T5HO fixture with 49-51 watt lamps to 44-46 watt lamps $ 2 per lamp T5HO fixture with 54 watt lamps to 44-46 watt lamps per lamp 4 T8 fixture with 32 watt lamps to 28 watt RW CEE T8 lamps; or 28 watt RW T8 lamps to 25 watt RW CEE T8 lamps $ 1 per lamp 4 T8 fixture with 32 watt lamps to 25 watt RW CEE T8 lamps $ 2 per lamp 4 T8 fixture with 32 watt lamps to 22 watt or less TLED (tubes) operating with existing fluorescent ballast must be QPL listed * (2 U-bent fixtures also available) $ 4 per lamp Pin-base CFL to Pin LED operating with existing fluorescent ballast - must be QPL listed, saving 3 watts or more per lamp $ 2.50 per lamp CEE high-performance product must be qualified and listed for Reduced Wattage T8 products; TLED products must be QPL listed and meet DLC minimum requirements. Replace 4-Foot T8 and T5HO fluorescent lamps with Reduced Wattage lamps that save more than 3-watts per lamp. Section 7 Light Emitting Diode (LED) Lighting Products (Interior Fixtures Ambient/Task Lighting) Example application: Replace incandescent track head PAR lamp with screw-base LED replacement PAR lamp Recessed Canister Downlights: Qualified and listed ENERGY STAR LED product (must replace 150 watt or less incandescent) - other configurations may qualify as a custom incentive and $ 30 per fixture may be approved on a case-by-case basis Qualified LED PAR/Directional replacement lamp with integral driver: < 20 watts lamps $ 15 per lamp Qualified LED PAR/Directional replacement lamp with integral driver: 20 watts or greater $ 20 per lamp Qualified LED Screw-in decorative lamp (flame tip, torpedo, globe, etc.): > 2 watts replacing incandescent of 40 watts or less per lamp Qualified LED Screw-in A Lamp, Medium base (replace incandescent of 100 watts or less) $ 10 per lamp LED Refrigeration Case Lighting: T12 or T8 to LED (hardwire retrofit) - use LED Case Lighting tab in lighting calculator tool LED Refrigeration Case Lighting (new cases) - use 120G form $ 10 Motion Sensor on Refrigerated LED Cases, Side bar (single) or Mullion (double) $ 2 $ 20 LED Refrigerated Case Lighting or Motion Sensors on LED Refrigeration Cases: Contact program representative for additional requirements (access the LED Case Lighting tab in the lighting tool to calculate the incentive for LED case lighting fixture retrofits), must hardwire LED. All screw-in type LED lamps listed in section above must be ENERGY STAR qualified and listed. All LED PAR/Directional lamps in section above must replace incandescent for a prescriptive incentive. Specialty/Decorative LED lamps < 2 Watts are exempt from the QPL requirement but must have a minimum warranty of 3-years, must qualify as a custom lamp measure, and may be approved on a case-by-case basis. LED lamps/fixtures not listed here may qualify for custom incentives if they meet certain criteria. See Section 12 for information about custom incentives. * Mock-up for participant approval may be required to determine appropriate aesthetics, distribution, and light quality. Program Information 190L v2015.2 150701 Page 4 of 5
Section 8 Compact Fluorescent and Cold Cathode Lighting (Replaces Incandescent Only) Example application: Recess canister downlight with pin based two-21 watt CFL lamps (42W fixture) Compact Fluorescent (or cold cathode) with a screw base (dedicated base strongly recommended) $ 2 per lamp Hard-wired compact fluorescent fixture with electronic ballast 26 watts and less $ 20 per fixture Hard-wired compact fluorescent fixture with electronic ballast greater than 26 watts $ 30 per fixture Section 9 Exit Signs LED or photoluminescent only (must replace incandescent versions) $ 20 per fixture Section 10 Exterior Existing HID Including Parking Garage, Canopy Mounted, Pole Mounted, and Wall Mounted Example application: Replace 70 watt HID wall pack with 30 watt LED wall pack A. Exterior fixtures and retrofit kits (non-screw-in): HID, nominal lamp wattage 70 100 watts, to LED, 40 watts or less $ 75 per fixture HID, nominal lamp wattage of 150 175 watts, to LED, 90 watts or less $ 125 per fixture HID, nominal lamp wattage of 200 250 watts, to LED, 110 watts or less $ 175 per fixture HID, nominal lamp wattage of 320 400 watts, to LED, 150 watts or less $ 275 per fixture HID, nominal lamp wattage of 750 1000 watts, to LED, 400 watts or less $ 400 per fixture B. Lamp conversions: The following must remove or by-pass ballast and are limited to non-utility owned fixtures as retrofit or part of a new fixture: HID to LED screw-in replacement lamp Omni-directional (all wattages) 0 per lamp HID to LED screw-in replacement lamp Directional (all wattages) $ 60 per lamp HID to LED screw-in replacement lamp High Bay (all wattages) $ 75 per fixture Replace High Intensity Discharge (HID) fixture with LED luminaire or retrofit kit from QPL. Street/Roadway lighting not included here - see PI 190L-SL addendum. Section 11 Lighting Controls Example application: Integral warehouse aisle occupancy sensor mounted on T5, LED, or T8 High Bay fixture Occupancy Sensor, wall switch (interior) $ 35 per sensor Vacancy Sensor, wall switch (interior) - equipment not readily disabled by occupant $ 35 per sensor Occupancy Sensor (interior), fixture mount 0 per sensor Occupancy Sensor (interior), ceiling/corner/surface mount (hard-wired or wireless) $ 125 per sensor Exterior Occupancy Sensor, fixture or pole mount (wired or wireless), must reduce fixture to 50% of original wattage or less in unoccupied mode using dimming, step, bi-level, or on/off. $ 60 per sensor Section 12 Custom Lighting If you are considering a lighting project and do not see your equipment listed, then contact us to discuss whether your project may qualify for custom incentives (including lighting controls). Each custom lighting measure must be reviewed and pre-qualified by Energy Trust and must pass a cost-effectiveness analysis. Call us for more information. Program Information 190L v2015.2 150701 Page 5 of 5