Q-AIRE-V125, EV125F & EV125FH 125mm diameter Filtered Inlet/Extract Air Valve. n Low profile. n Adjustable for commissioning purposes

Similar documents
IAQ-V mm Ø Carbon Filtered Supply Valve

XS Fans Switches & Sensors

MRXBOX-VSC Visual System User Control Installation and Maintenance

NALTF & NALTRF Belt Drive Roof and Plantroom Twinfans

3ph Belt Drive, Run & Standby, Roof & Plantroom Twinfans

Drimaster365. Low Energy Positive Input Ventilation Unit. Installation and Maintenance Details. 150mm dia. Flexible Ducting

Installation and Maintenance

Terminator Input. (TIA) GRP Roof/Wall Input/Supply Fans. Installation and Maintenance

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

AXUS AXR. Roof Mounted Axial Fan for Smoke Control Installation and Maintenance. Handling

AXS. Installation and Maintenance. AXUS Swift Circular Long Cased Axial Flow Fans. 1.0 Introduction. 3.0 Installation And General Advice. 2.

QUIETSCROLL TWIN FAN RANGE

DX Ceiling Fan Kit 50Hz/60Hz Supply / Extract Units Installation and Maintenance

NALSF & NALSRF Belt Drive Roof and Plantroom Single Fans

MARK TEN. Belt Drive Roof Mounted Extract Fans. Installation and Maintenance. Standby motor when fitted. Anti-vibration mountings

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

Terminator. TRA/TRM/TRC Roof Extract Fan. Installation and Maintenance

DX Window Fan Kit 50Hz/60Hz Supply / Extract Units Installation and Maintenance

Melody 1 Platform Lift

SP2 Options Installation and Maintenance Instructions

Installation Instructions and User Guide. Tel : NEWTEAM 100 SERIES THERMOSTATIC MIXER SHOWER

HIGH TEMPERATURE TWIN SQUIF FANS

TA-2 RANGE OF THERMAL ANEMOMETERS

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Actuators for Fire and Smoke Protection Dampers

Installation Manual TWM Performance Short Shift Kit 2006 and up Toyota Yaris

GS-AQ1000 VOC Indoor Air Quality Sensors

Timing Chain - Renew ( )

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

Actuators for Fire Protection Dampers

Installation, Operation & Maintenance

Installation Manual TWM Performance Full replacement short shifter assembly Civic all trims and models

HILLSTONE DC LOAD BANK

INSTRUCTION MANUAL. AMS 1500 One Piece. Negative Pressure Unit (AMS-1500 NPU 230V)

Actuators for Fire and Smoke Protection Dampers

SatchwellTM ALMS, ALXS, ALES SPRING RETURN LINEAR ACTUATORS. Satchwell FEATURES

MPS14 Rack Mount Power Supply

SERIES PG. Perforated Face

Actuators for Fire and Smoke Protection Dampers

Timing Chain Renew ( ) Renew. Section Title. Special Tools. Proprietary Tools Scraper Engine support bar

ROMpak Series. Keeping the World Flowing. Installation Manual. Valve Actuators

PSS 5000 Standard & Compact (For systems with CPB50x)

Rimac Spring Tester Retro-Fit Kit

CONTACTS EGR VALVE TESTER 66248

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V)

Air duct switching damper

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

STOP IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED TO ACTIVATE YOUR LIMITED LIFETIME WARRANTY GO TO: CORSAPERFORMANCE.

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

INSTALLATION OVERVIEW: Connector, 7-pin. Clips w/plastic Ties. Plastic Ties. Connector, 52-pin. Step 22 a) Step 21 a) Step 23. Step 24.

Exhaust System Installation for the Ford Mustang PN s ,140584,140585,140589,140590,140591

RECTANGULAR EXTRACT FANS

XT INSTRUCTION MANUAL

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

BATHROOM EXTRACT FANS DECOR-100 Series

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

Contents. AQ Instruction Manual

##CFG BWOP Manuals## Quasar elite HD-LED Mobile Models Assembly Guide

Installation for the Ford Mustang V-6 PN s , ,

Safety Precaution. Notation. Meaning of symbols WARNING CAUTION

The Powermatic User Guide Test Sieve Shaker

Source Capture Air Purification System

Exhaust System Installation for the Ford Mustang PN s , , , , , , , ,

Exterior Pump Range INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

Installation Manual Volvo C30 T5 Front Mount Intercooler System

Warning. Document ref: A October 2015

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Breezair TBA 550 Installation Manual

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

User Instruction Manual

2. Remove the four bolts and lift the panel off. The white cap of filter module is underneath. It looks like this (seen removed from the tank).

INSTRUCTION MANUAL MAGNA RAIL

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

User Instruction Manual

Exhaust System Installation for Corvette, C6 or Z06 PN s , 11811, 11812, 11814, 11815, 11816, 11917

3/8 Universal Joint Phillips Head Screwdriver

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Compact Sine Inverter

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

Mira Mode Shower and Bath Fittings

Exhaust System Installation for the Ford Mustang PN s , , , , , , , ,

Exhaust System Installation for Audi S4, S5 & S5 Sportback PNs ,

1901 Thermostatic Shower Mixer

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

SERVICE MANUAL OF SERVOMOTORS HD/HR RANGE

Installation for Honda Civic Type R PN

OPERATIONAL INSTRUCTIONS

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Automatic Pill Dispenser. (Model 3/07) Instructions

Alternating Current Revolution per minute Protective Earth Ground. Protected from dripping water Fuse Attention, Consult Accompanying Document

IN & TM Series User Manual

SmartX MF and MS

Temperature Controller (Heat Pumps)

ELECTRICAL. Moisture Meter User Guide

Insertion Thermostat

##CFG BWOP Manuals## Astramax Mobile Models Assembly Guide

Transcription:

Q-AIRE-V125, EV125F & EV125FH 125mm diameter Filtered Inlet/Extract Air Valve Installation Guide The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 Introduction This 125mm dia. inlet/extract valve can be used either on its own or fitted with a filter or humidistat control circuit board or both. The filtered valves Q-AIRE-EV125F and Q-AIRE-EV125FH are adjustable and lockable and require no adjustment after a filter change. The valves are supplied with an airflow screen which can be inserted into the main body of the valve to deflect the airflow away from walls, or away from other obstructions such as smoke alarms. The Q-AIRE-EV125FH Extract Valve comes with an inbuilt humidity sensor which simply uses the Ecosmart SELV cable to connect back to the Nuaire Ecosmart compatible fan unit. This is available where the specification calls for room mounted humidity sensors. The sensor is behind the filter to extend the sensor to prevent it from getting dirty. 2.0 Main features n Low profile n Adjustable for commissioning purposes n Decorative panel to cover commissioning screw n Spring loaded to prevent vibration n Valve removable without disturbing commissioning position n Supplied with airflow screen to enable air to be directed away from obstacles n Valve damper removable to allow filter access n Optional humidity PCB for connection to ventilation unit n Humidity set point accessible on damper removal Fig 4. Components. Fig 1. Q-AIRE-V125 Supply / Extract Valve without filter. Humidity PCB Filter Main Body Fig 2. Q-AIRE-EV125F Extract Valve complete with filter. PCB Cover Valve Damper Airflow Disc Airflow Screen Fig 3. Q-AIRE-EV125FH Extract Valve complete with filter and humidistat. Spring and adjustable screw Decorative Panel Nuaire: A Trading Division of Polypipe Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA T: 029 2088 5911 F: 029 2088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk 1 14. 09. 17. Leaflet Number 671687

3.0 Installation Installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory governing regulations. Installation as a supply valve: Cut a 145mm Dia. hole in the ceiling where the valve is to be situated Line up on main body and fit damper to main body (see fig 5) Position main body/damper into the hole and mark the fixing position (see fig 5) Remove damper, fit ducting to main body and screw to ceiling (see fig 6) See important note and fig 7 re fixing within 1 metre of a wall If required fit Airflow screen to flow disk (fig 7) Fit damper assembly to main body by aligning the triangle symbols, then press together and twist damper assembly clock wise, (you will hear a click when damper is in a locked position. (see fig 8) Once all valves are in position they can be commissioned using the adjustment screw (see fig 9). On completion clip decorative panel in place (see fig10). If a valve is situated within 1 metre of an obstruction (eg a wall or smoke alarm) then the airflow screen should be fitted to guide the airflow away from the obstruction (see fig 7). This is achieved by fully unscrewing the damper assembly, sliding the airflow screen into place ensuring a positive fit (clicks into place). Once in its locked position re-tighten the fixing screw. Fig 7. If required fit Airflow screen to flow disk. If the valve is 1 metre or less to an obstruction or wall. Position main body/damper so that one of the Tri-sectors points towards the obstruction. It can then be blanked off using the airflow screen. Fig 5. Fit damper to main body and position in the hole. Main body. The airflow screen. Damper. Fig 6. Remove damper, fit ducting to main body and screw to ceiling. Fig 8. Fit damper assembly to main body by aligning the triangle symbols, then press together and twist damper assembly clockwise, (you will hear a click when damper assembly is in a locked position. Alignment markers 2 14. 09. 17. Leaflet Number 671687

3.0 Installation cont. Fig 9. Once all valves are in position they can be commissioned using the adjustment screw. The gap between the airflow disk and the main body determines the airflow that can pass through the valve. This gap can be adjusted using the screw on the underside of the flow disk (clockwise to reduce the gap and flow), (anti-clockwise to increase the gap and flow). 4.0 Connecting the Q-AIRE-EV125FH to a Nuaire MVHR or MEVDC fan Unit The Q-AIRE-EV125FH Extract Valve comes with an inbuilt humidity sensor which simply uses the Ecosmart SELV cable to connect back to a Nuaire Ecosmart fan unit. This is available where the specification calls for room mounted humidity sensors (See section 5.0). Note: Unsuitable for use with MEVAC range and MEVDC2 product. The plastic male plug has moulded tabs or protrusions on one side to match and lock it to the board mounted socket thereby ensuring that correct electrical connection is made, so its imperative that the cables are offered to the right side of the plug in precisely the right sequence. Do not force the plug in to the socket. Fig 11. Using the Data Cable supplied, plug one end into the valve PCB. Adjustment screw. Fig 10. Once the airflow is set, fit the decorative facia panel onto the airflow disk. Plug one end Data Cable into the valve PCB. A 10m data cable is supplied with the valve, with other lengths available. Please see Guidance Notes 5, enclosed with data cable for more details. Route the cable back to the fan unit, ensuring that it is separated from mains voltage carrying cables. Ensure there is at least a 50mm separation between data and mains carrying cables If data and mains cables have to be crossed be sure that they cross at 90 o to each other Plug the opposite end of the cable into your Nuaire fan unit (Unit must be isolated) following the fan units Installation and Maintenance Guide. Further information can be found in the Guidance Notes 5 enclosed with the data cable. 3 14. 09. 17. Leaflet Number 671687

5.0 Adjusting the Q-AIRE-EV125FH Humidity Sensor Adjusting the sensor set points - Adjustable RH setting 65-85% Assuming the Valve(s) are installed, adjustment of the RH set points are achieved by removing the damper assembly (see fig 9). To expose the humidistat location (fig 12). Fig 12. Humidistat location. Indication LED Adjustment Dial % A Using a small screwdriver, gently turn the adjustment dial either clockwise or anti-clockwise to increase or decrease the set point. Minimum RH Setting = 65% RH. When adjustments are made to the sensor, the Indication LED light on the sensor will flash on and off to show the set point. First, flashes will indicate the set point in TENS, then after a short pause the LED flashes will indicate UNITS. For example seven flashes and three flashes show a RH set point of 73% (shown in the lookup table on the right). 6.0 Maintenance The filter can be changed quickly by simply removing the damper assembly, and then the filter. Having re-placed the filter, the damper assembly is the simply re-postioned without any adjustment of the commissioned set point taking place. Fig 13. Remove the damper assembly to change the filter. Maximum RH Setting = 85% RH No of times %RH (Tens) No of time LED flashes %RH (Units) LED flashes (After a small pause) 6 60 % 0 0 % 7 70 % 1 1 % 8 80 % 2 2 % 3 3 % 4 4 % 5 5 % 6 6 % 7 7 % 8 8 % 9 9 % 7.0 Replacement of Parts Should any part need replacing, Nuaire keep extensive stocks for quick delivery. When ordering spare parts, please quote the product code. Filter Part Number: Q-AIRE-FILTERKIT 8.0 Warranty The 5 year warranty starts from the day of delivery and includes parts and labour for the first year and parts only for the remaining 4 years. This warranty is void if the equipment is modified without authorisation, is incorrectly applied, misused, disassembled, or not installed, commissioned and maintained in accordance with the details contained in this manual and general good practice. The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions of Sale. Customers purchasing from outside of the UK should contact Nuaire International Sales office for further details. 9.0 After Sales Enquiries For technical assistance or further product information, including spare parts and replacement components, please contact the After Sales Department. Telephone 02920 858 400 4 14. 09. 17. Leaflet Number 671687

90 Installation Guide 10.0 Dimensions (mm) Fig 14. Side view. 180.2 172.5 143.8 125 Duct Size 68.1 171.1 - (Optional filter fitted) Fig 15. Top view. 18.0 - Closed 38.0 - Open (max) 6 143.8 160 PCD 5 14. 09. 17. Leaflet Number 671687