Characteristics Application System Optical Turbidimeter Processing Indication, switching, measuring Process connection Welded nozzle, Milk-pipe connection Media Liquids, viscous media Pressure range -1..+10 bar Continuous turbidity measurement Brewery Diary Food- and beverage industry Machine building Pharmacy industry Cosmetic industry Biotechnology Media temperature 0..+90 C, CIP-/SIP-capable, 120 C < 30 min 2 pi-ma-truebung_e V1.00-00
Function The turbidity measurement method is based on the optical principle of light scattering. The device emits a light beam. This applies to particles in the fluid and parts of the light will be reflected (scattered). In the opposite to the light source is a light sensor, receiving with increasing scattering ( higher proportion of particles greater turbidity ) less and less light. The following images show the effect : Advantage The parts coming into contact with the media complies with FDA requirements and are CIP-/SIP capable. Steam sterilization for a short time up to 120 C. No mechanical moving parts Compact construction design for food and hygiene compliance Independent of pressure, temperature and density changes Maintenance-free Installation without gaps and cavity-free Detection of liquids such as milk or beer Mounting The following notes must be observed : The measuring tube must be completely filled Air bubbles and foam formation should be avoided The installation near inspection glasses should be avoided No sedimentation in the near of the optic itself Installation The following instructions must be observed: The measuring tube must be completely filled Air bubbles and foaming must be prevented. Installation near viewing glasses must be avoided. Sediments may not deposit near the lens. From knowledge of the emitted and the received light, the integrated microcontroller computes the turbidity as a percentage of the maximum measurement value. This value can be converted with an integrated conversion table into a material-specific concentration values, or in the formazine based unit FAU. The values for the current output, the two switching outputs and the optional connected LC display derived from this result. There are a variety of parameters in the operating menu to fit the turbidimeter for the best result in the application. For instance : because of the programmable time behavior, short-term disturbances in the medium courses no uncontrolled switching operations or troubled measured values at the current output. As an example, measurement diagrams for various dairy products Position Characteristic Danger bubbles or partly filled pipe Ideal good measurement result Ideal good measurement result Danger open line section Danger bubbles or partly filled pipe Mistakes reserved, technical specifications subject to change without notice. pi-ma-truebung_e V1.00-00 3
Turbidimeters MAT433 / MAT437 Dimensions Wide measuring range for scanning high turbidity level Absorption turbidity measurement according to EN ISO 27027 2 switch outputs, function programmable Analog output 0/4..20 ma Parametrization via GHMware and internal mini USB interface Wide view LED status display (MAT433) Graphic LC-Display with capacitive buttons (MAT437) Characteristics The turbidimeters MAT433 and MAT437 are used for phase detection in food and beverage industry. The absorption measurement principle according to EN ISO 27027 is designed to measure very high turbiditys. The turbidity is output as a percentage of the maximum measurement value. This value can be converted with an integrated conversion table into material-specific concentrations or into the formazine based unit FAU. Technical data Power supply Supply voltage Electrical connection : 18..30 V DC, max. 3 W : M12 plug or cable gland M16x1.5 polyamide (PA) or stainless steel (1.4305) CE-conformity : EN 61326-1:2013 Ambient conditions Ambient temperature : -10..+60 C Climatic class : EN 60068-2-38:2009 Vibration class : EN 60068-2-6:2008, GL test 2 Sensor Measuring range : 0 100 % Absorption, scalable in material specific concentration units, 0 4000 FAU Accuracy : +/- 2 % Process temperature : 0..+90 C, 120 C < 30 min Process pressure : 0..10 bar Process material : 1.4404, sapphire glass Process connection : welded connection acc. EN 10357:2013 series A (former DIN 11850, series2), Milk pipe thread acc. DIN 11851 (optional) Outputs Analog output : active 0/4..20 ma, burden < 600 Ω Switching outputs : 2 x transistor PNP / NPN programmable max.30 V DC, 100 ma Response time : programmable 0,01.. 10 s Display MAT433 : LED's, 3 colors, programmable Display MAT437 : Graphic LC-Display, lighted white/red 4 capacitive buttons Case : round stainless steel housing Ø 59 mm Material : 1.4305 LED / LCD window : acrylic glass (PMMA) Protection class : IP67 / IP69K Dimensions MAT433 DN H1 [mm] H ges [mm] D [mm] DIN EN 10357 Series A L [mm] VARINLINE - housing with welded nozzle L [mm] milk-pipe thread nozzle DIN 11851 DN25 112 191 29x1,5 180 238 DN40 118 203 41x1,5 180 246 DN50 124 215 53x1,5 180 250 DN65 132 231 70x2 250 330 DN80 139,5 246 85x2 250 340 DN100 149 265 104x2 250 358 Dimensions MAT437 DN H1 [mm] H ges [mm] D [mm] DIN EN 10357 series A L [mm] VARINLINE - housing with welded nozzle L [mm] milk-pipe thread nozzle DIN 11851 DN25 120 199 29x1,5 180 238 DN40 126 211 41x1,5 180 246 DN50 132 223 53x1,5 180 250 DN65 140 239 70x2 250 330 DN80 147,5 254 85x2 250 340 DN100 157 273 104x2 250 358 Connection diagrams M12 plug Terminal clamps and USB Mini-B plug Cable colors (plug): 1 = brown 2 = white 3 = blue 4 = black 5 = gray 4 pi-ma-truebung_e V1.00-00
Displays Order Code 1. 2. 3. 4. 5. 6. MAT433 - - - - - - 1. Nominal diameter 025 DN25 040 DN40 050 DN50 065 DN65 080 DN80 100 DN100 2. Optical path length 06 6 mm 3. Process connection 1 Welded nozzle (incl. VARINLINE housing) 2 Process connection according to APT article 4. Electrical connection 0 M12-plug (standard) 1 Cable gland M16x1,5; polyamide (PA) 2 Cable gland M16x1,5; stainless steel (1.4305) 5. Optionen 00 Without Options 6. Certificate acc. DIN EN 10204. Specify when requested WZ2.2 Certificate of conformity 2.2 Process adaptions Additional milk-pipe-adapter weld on the VARINLINE -case of the MAT43x. 1. 2. 3. 4. APT - - - - 1. Process connection 3 Milk pipe DIN11851 two-sided thread nozzle 2. Nominal diameter 3 DN25 4 DN40 5 DN50 6 DN65 7 DN80 8 DN100 3. Optionen 0 Without Options 1 Two-sided cone nozzle with union nut 2 Thread- / cone nozzle with union nut 4. Certificate acc. DIN EN 10204. Specify when requested WZ2.2 Certificate of conformity 2.2 1. 2. 3. 4. 5. 6. MAT437 - - - - - - 1. Nominal diameter 025 DN25 040 DN40 050 DN50 065 DN65 080 DN80 100 DN100 2. Optical path length 06 6 mm 3. Process connection 1 Welded nozzle (incl. VARINLINE housing) 2 Process connection according to APT article 4. Electrical connection 0 M12-plug (standard) 1 Cable gland M16x1,5; polyamide (PA) 2 Cable gland M16x1,5; stainless steel (1.4305) 5. Options 00 Without Options 6. Certificate acc. DIN EN 10204. Specify when requested WZ2.2 Certificate of conformity 2.2 Accessory ACI211 USB connection cable ACH connection cable VARINLINE is a registered trademark of GEA Tuchenhagen GmbH, Büchen, Germany pi-ma-truebung_e V1.00-00 5
6 pi-ma-truebung_e V1.00-00
pi-ma-truebung_e V1.00-00 7
Headquarter GHM GROUP CORPORATE Schloßstraße 6 88453 Erolzheim GERMANY Phone +49 7354 937233-0 info@ghm-group.de www.ghm-group.de Centers of Competences GHM GROUP Greisinger Hans-Sachs-Straße 26 93128 Regenstauf GERMANY Phone +49 9402 9383-0 info@greisinger.de www.greisinger.de GHM GROUP Honsberg Tenter Weg 2-8 42897 Remscheid GERMANY GHM GROUP Martens Kiebitzhörn 18 22885 Barsbüttel GERMANY GHM GROUP Imtron Carl-Benz-Straße 11 88696 Owingen GERMANY Delta OHM S.r.l. a socio unico GHM GROUP Delta OHM Via Marconi 5 35030 Caselle di Selvazzano Padova (PD) ITALY Phone +39 049 8977150 info@deltaohm.com www.deltaohm.com Valco srl GHM GROUP VAL.CO Via Rovereto 9/11 20014 S. Ilario di Nerviano Milano (MI) ITALY Phone +39 0331 53 59 20 valco@valco.it www.valco.it GHM GROUP International Austria Office Austria Breitenseer Str. 76/1/36 1140 Vienna AUSTRIA Phone +43 660 7335603 a.froestl@ghm-messtechnik.de Brazil & Latin America GHM Messtechnik do Brasil Ltda Av. José de Souza Campos, 1073, cj 06 Campinas, SP 13025 320 BRAZIL Phone +55 19 3304 3408 info@grupoghm.com.br Czech Republic / Slovakia GHM Greisinger s.r.o. Ovci hajek 2 / 2153 158 00 Prague 5 Nove Butovice CZECH REPUPLIC Phone +420 251 613828 Fax +420 251 612607 info@greisinger.cz www.greisinger.cz Denmark GHM Maaleteknik ApS Maarslet Byvej 2 8320 Maarslet DENMARK Phone +45 646492-00 Fax +45 646492-01 info@ghm.dk www.ghm.dk France GHM GROUP France SAS Parc des Pivolles 9 Rue de Catalogne 69150 Décines-Charpieu (Lyon) FRANCE Phone +33 4 72 37 45 30 a.jouanilou@ghm-group.fr India GHM Messtechnik India Pvt Ldt. 209 Udyog Bhavan Sonowala Road Gregaon ( E ) Mumbai - 400 063 INDIA Phone +91 22 40236235 info@ghmgroup.in www.ghmgroup.in Italy for Greisinger & Delta OHM GHM GROUP Delta OHM Via Marconi 5 35030 Caselle di Selvazzano Padova (PD) ITALY Phone +39 049 8977150 a.casati@ghm-messtechnik.de Italy for Honsberg, Martens, Val.co GHM GROUP Val.co Via Rovereto 9/11 20014 S. Ilario di Nerviano Milano (MI) ITALY Phone +39 0331 53 59 20 alessandro.perego@valco.it Netherlands GHM Meettechniek BV Zeeltweg 30 3755 KA Eemnes NETHERLANDS Phone +31 35 53805-40 Fax +31 35 53805-41 info@ghm-nl.com www.ghm-nl.com South Africa GHM Messtechnik SA (Pty) Ltd 16 Olivier Street Verwoerdpark, Alberton 1453 SOUTH AFRICA Phone +27 74 4590040 j.grobler@ghm-sa.co.za...and more than 100 qualified distributors! Visit us at: www.ghm-group.de