HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

Similar documents
HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

HS1E Series Full Size Solenoid Locking Switches

Door Interlock Switches

HS6B Series Subminiature Interlock Switch

Door Interlock Switches

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

HS5E Series Miniature Solenoid Locking Switches

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Door Interlock Switches

HS6E - L 4 4 B 01 - G

HS1C Interlock Switches with Solenoid

HS6E Subminiature Interlock Switches with Solenoid. Double Installation. Part Number. Cable Length (+) ( ) A2 A1

HS1L Interlock Switches with Solenoid

HS1C-P Interlock Plug Unit with Door Lock

HS5D Miniature Interlock Switches

Solenoid Locking Safety Switches

HS5D Miniature Interlock Switches

HS1E-K Interlock Switches with Solenoid (3-circuit)

Solenoid Locking Safety Switches

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

Door Interlock Switches

Standard Interlock Safety Switches

Interlock Switches. Safety. Selection Guide HS6B Subminiature HS5D Miniature HS2B Full Size...

HS5E Miniature Interlock Switches with Solenoid

HS1E Interlock Swithes with Solenoid

Head Removal Detection Function for Safer Performance

Section. Safety Products Selection Guide...B-2

SG-B1 SERIES / SG-A1 SERIES

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Door Interlock Switches

Standard Interlock Safety Switches

HS5E Miniature Interlock Switches with Solenoid

HS5E Miniature Interlock Switches with Solenoid

HS6B HS6E. Angled connection. cable. Compact with three poles of contacts. (HS6B) Small interlock switch with five poles and solenoid.

ct O en n Tr ve Solenoid Indicator (1) TÜV rating AC V, 3A 3 Mounting Examples

Safety device new products line up. Introducing a safety door switch with solenoid interlock that is among the world s thinnest*

HS6E Subminiture Interlock Switches with Solenoid

HS6B Subminiature Interlock Switches

Hinged Safety Door Switch

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

Interlock Switches Interlock Plugs

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

2 Specifications and Ratings. Applicable Standards. Operating Condition. Thermal Current Ith 10A Contact Ratings. Operating Speed

Safety Limit Switch

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

HL (AZH) Limit Switches

HL (AZH) LIMIT SWITCHES

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Safety-door Switch. Ordering Information

Manual Reset Limit Switch

PRODUCT SPECIFICATION. Stack Lights. Series.

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

DL (AZD1) Mini Limit Switches

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

HL (AZH) Limit Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4BS CSM_D4BS_DS_E_8_4

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

Think Automation and beyond... IDEC Safety Interlock Switches

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

D4GS-N CSM_D4GS-N_DS_E_7_2

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Safety switches with separate actuator

22mm XW E-Stops. UL File #E68961 CCC No Specifications

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

LR-LX-LK-LW Safety Switches with separate actuator

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

HS7A-DMC Non-contact Interlock Switches

Miniature Switches & Pilot Devices

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

AF40... AF96 3-pole contactors Technical data

SFS-UFS Single Foot Switches

VL (AZ8) Limit Switches

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

VL (AZ8) Mini Limit Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

D4BL. Guard Lock Safety-door Switch

PRODUCT SPECIFICATION. Foot Switches. Series.

Safety Limit Switch

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

LK Position Switches TECHNICAL DATASHEET.

D4NH CSM_D4NH_DS_E_7_1

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

Cable (Rope) Pull Switches Lifeline 4

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web: -

F3S-TGR-KHL1/-KHL3/-KHL3R

Mechanical Min. 20 million operations. Min. 2 million operations for the Model SL1-B. Min. 2 million operations for high oil. (All values assume overt

Model Number Structure

Transcription:

HSB Series Full Size Interlock Switch HSB features: Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available with or without an indicator (red or green) Flexible Installation: Two actuator entries and three conduit ports are provided Select from two circuit configurations (NO-NC or NC). Degree of Contact Protection: IP67 Body Model HSB (alum. die-cast housing) EN088 EN6097-5- IEC6097-5-. The special key wrench (HS9Z-T) for removing the cover and manual unlocking is included with the switch.. Order the actuators separately (not supplied with the switch). Keys and Accessories Appearance Part Number Description HS9Z-A HS9Z-A HS9Z-A3 HS9Z-T HS9Z-P Contact Configuration NC-NO NC *Torx is a registered trademark of Camcar Textron. Pilot Light Without With red LED With green LED Without With red LED With green LED Straight (Mainly for sliding doors) Right-angle (Mainly for rotating doors) Adjustable Key Wrench (included with switch) Conduit Opening Plug GS-ET-5 BG standard in Germany Part Numbers Part Number HSB-R HSB-R-R HSB-R-G HSB-0R HSB-0R-R HSB-0R-G Direct Opening Action Part Number Key HSB - 0 R - R Housing Color R (Red) Indicator Color R (Red), G (Green) IndicatorRated Voltage (V DC) Blank (without indicator) Configuration : NO-NC 0: NC Not necessary to specify color if indicator option not chosen. Overview X Series E-Stops Door Interlock Switches Enabling Switches Barriers AS-Interface Safety at Work

AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview Specifications Conforming to Standards Operating Temperature Storage Temperature Operating Humidity Altitude IEC6097-5-, EN6097-5-, GS-ET-5, UL508 5 to +70 C (no freezing) to +80 C 85% RH maximum (no condensation),000m maximum Rated Insulation Voltage (Ui) 300V (between LED and ground: 60V) Impulse Withstand Voltage (Uimp) Insulation Resistance Electric Shock Protection Class Pollution Degree Degree of Protection Vibration Resistance Shock Resistance Operating Extremes Damage Limits Operating Speed Positive Opening Travel Positive Opening Force Thermal Current (Ith) Rated Operating Current (Ie) Operating Frequency Mechanical Life Electrical Life Conditional Short-circuit Current kv (between LED and ground:.5 kv) Between live and dead metal parts: 00 MΩ minimum Between live metal part and ground: 00 MΩ minimum Between live metal parts: 00 MΩ minimum Between terminals of the same pole: 00 MΩ minimum Class I (IEC6) 3 (IEC6097-5-) IP67 (IEC6059) 0 to 55 Hz, amplitude 0.5mm p-p 60 m/sec (approx. 6G),000 m/sec (approx. 00G) m/sec maximum mm minimum 0N minimum 0A 900 operations/hour,000,000 operations 00,000 operations (rated load) 00A (IEC6097-5-) Recommended Short Protection 50V, 0A fuse (Type D0 based on IEC6069-, 6069-) Indicator Weight Operating Voltage Current Light Source Lens Color Operating Voltage (Ue) 30V 5V 50V AC DC V DC 0 ma LED lamp Red or Green ( mm dia. Lens) Approx. 80g Resistive load (AC) Inductive load (AC5) Resistive load (DC) Inductive load (DC3) 0A 0A 8A A 0A 5A.A.A 6A 3A.A 0.6A

HSB Door/ Switch Status Door Application Examples and Diagrams HSB- (NO-NC) Diagram Main Aux. HSB-0 (NC) Diagram Main Aux. Status Status Door Closed Machine ready to operate 3 + + - - 3 Main Auxiliary Door opened Machine cannot be started 3-: Closed 3-: Open -: Open -: Closed Main Auxiliary + + - - 3-: Closed 3-: Open -: Closed -: Open. Main : used to enable the machine to start only when the main circuit is closed. Auxiliary : used to indicate whether the main circuit or door is open or closed.. Terminals + and - are used for the LED indicator, and are isolated from door status. Wire the terminals only when needed. 3 3 Main Auxiliary Main Auxiliary Overview X Series E-Stops Door Interlock Switches Enabling Switches Barriers AS-Interface Safety at Work

AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HSB - using the straight actuator (HS9Z-A) (Horizontal Mounting) Slot Plug (Note) (Vertical Mounting) 5.3 RP 30 3.8 9 Cover 7. 9 9.3 9.3 Cover (red) Dimensions (mm) HSB - using the Right-angle actuator (HS9Z-A) (Horizontal Mounting) 30 RP 68.8 36.5 RP 30 6 36.5 9 3.8 6 0 Conduit Port 0 Conduit Port G/ G/ 9.5 5 Plug the unused actuator insertion slot using the slot plug supplied with the interlock switch. Straight HS9Z-A -M6 Screws Mounting Holes Cover -M5 Screws 6.5 ±.0 Adjustable.5 Slot Plug (Note) (Vertical Mounting) 6.5 6 Cover RP 30 9.5 36.5 5 0 Conduit Port G/ Cover 9.5 ±.0 -M5 Screws Dimensions Right-angle HS9Z-A Mounting Holes -M6 Screws The actuator angle is adjustable (0 to 0 ) for hinged doors. The minimum radius of the door opening can be as small as 00mm. Angle Adjustment 5 9.5 36.5 0 Conduit Port G/ 8.5 ±.0. 9. 0 Using the screw (M3 hex socket head screw), the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: (0 ) to 0 5 6 5 6 7..5.5 7.5 ±.0.5 9. Cover (red).5 9.5 5 Angle-adjustable HS9Z-A3 (Note) 8 Stop Film (attached) 5 0 Door hinge 33 max. () Angle Adjustment Screw (M3 hexagon socket head screw) The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the entry slot of the safety switch. Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm) After adjusting the actuator angle, apply loctite or the like to the adjustment screw to prevent it from loosening. 9. 30 5 6 5 35 5 6 5 35 58 7 58 -M6 Screws

Safety Precautions In order to avoid electric shock or a fire, turn the power off before installation, removal, wire connection, maintenance, or inspection of the switch. If relays are used in the circuit between the safety switch and the load, consider degrees of the danger and use safety relays, since welded or sticking contacts of standard relays may invalidate the functions of the safety switch. Regardless of door types, do not use the safety switch as a door stop. Install a mechanical door stop at the end of the door to protect the safety switch against excessive force. Do not apply excessive shock to the switch when opening or closing the door. A shock to the door exceeding,000 m/sec (approx. 00G) may cause the contacts of the switch to chatter, and a malfunction of the switch may occur. For connection of wires, unscrew the cover. Unnecessary loosening of other screws may cause a malfunction of the switch. For Rotating Head Directions The heads of the HS5E/HS5B can be rotated in 90 increments after removing the screws on the corners of the head. Prevent entry of foreign objects into the switch during removal of the head. Tighten these screws with torque designated in the instruction sheet. Improper torque may cause errors. Factory Setting Minimum Radius of Hinged Doors When using the interlock switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (HS9Z-A55). Wire Connection Head can be rotated. The HSB has 3 conduit ports, which are closed as a part of the molded switch housing. Make an opening for wire connection by breaking one of the conduit-port knockouts on the switch housing using a screwdriver. When breaking the conduit port, take care not to damage the contact block or other parts inside the switch. Operation Precautions - for all series HS5E/HS5B Precautions HSB Precautions Do not place a PLC in the circuit between the safety switch and the load. The safety security can be endangered in the event of a malfunction of the PLC. Do not disassemble or modify the switch. It may cause a breakdown or an accident. Prevent foreign objects such as dust and liquids from entering the switch while connecting conduit or wiring. If the operating atmosphere is contaminated, use a protective cover to prevent the entry of foreign objects into the switch through the actuator entry slots. Entry of a considerable amount of foreign objects into the switch may affect the mechanism of the switch and cause a breakdown. Do not store the switches in a dusty, humid, or organic-gas atmosphere. Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A5 When the door hinge is on the extension line of the interlock switch surface: When door hinge is on the extension line of the actuator mounting surface: Cracks or burrs on the conduit entry may deteriorate the housing protection against water. When changing to another conduit port, close the unused opening with an optional plug (Part No. HS9Z-P). Overview X Series E-Stops Door Interlock Switches Enabling Switches Barriers AS-Interface Safety at Work

HSE Precautions AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview Wire Connection Make an opening for wire connection by breaking one of the conduit-port knockouts on the switch housing using a screwdriver. Before breaking the knockout, temporarily remove the connector-fixing lock nut from the switch. When breaking the knockout, take care not to damage the contact block or other parts inside the switch. Cracks or burrs on the conduit entry may deteriorate the housing protection. When changing to the other conduit port, close the unused opening with an optional plug (accessory). Manual Unlocking Plug Type No. HS9Z-P Remove the screw located on the unlocking entry at the side of the switch using the key wrench included with the switch. Then insert a small screwdriver into the switch to push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). Insert a small screwdriver into the elliptical hole on the back of the switch, then push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). Regardless of door type, do not use the safety switch as a locking device. Install a locking device independently, for example, using a metal latch (also applicable to HSE). The safety switch cover can be only removed with the special key wrench supplied with the switch or with the optional screwdriver (also applicable to HSB and HSE). Remove the screw located on the unlocking entry at the side of the switch using the key wrench included with the switch. Then insert a small screwdriver into the switch to push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). Caution: After the unlocking operation, put the screw back into the unlocking entry for safety. HSC Precautions. This unlocking method is intended for an escape from a machine when a person is locked in. For access to the unlocking entry, an access hole should be opened on the mounting panel. When opening the hole, apply proper protection against water or other foreign objects.. Caution: After the unlocking operation, put the screw back into the unlocking entry for safety. Screwdriver M5 Screwdriver 3.5 6 Unlock Normal Position Unlock Manual Unlocking Position

Operation Precautions Applicable Crimping Terminals (Refer to the Crimping Terminal or shown in the drawing below.) HSC Terminals No. to 6: Use solid or stranded wires only (crimping terminals not applicable). Terminals No. 7 and 8: Crimping Terminal Ground Terminal: Crimping Terminal HSB Ground Terminal: Crimping Terminal Other Terminals: Crimping Terminal HSB, HS5B, and HSE Crimping Terminal 3.6 min. 3.5 max. ø3.6 min. 6.9 max. Crimping Terminal Use an insulation tube on the crimping terminal. Crimping Terminal Wire Approx. mm Crimping Terminal Insulation Tube Installation Examples (see the diagrams below) Mounting on Sliding Doors Door HS9Z-A Door Stop Mounting on Hinged Doors HS9Z-A Latch 3.5 min. 3.8 max. ø. min. 7.6 max. HS9Z-A Applicable Connectors (As shown below) Use connectors which maintain the IP67 protection. Applicable Connector Dimensions Flex Conduit: VF03 (Japan Flex) www.nipolex.co.jp Steel Connector (G/): ALC-03 (PF3.5): RBC-03PG3.5 G/ Recommended Screw Tightening Torque HSC: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( or 6 pcs of M5 hex socket head cap screws) HSB: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( or pcs. of M5 hex socket head cap screws) HSB: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( pcs of M5 hex socket head cap screws) HS5B:.0±0. N-m (approx. ± kgf-cm) ( pcs of M hex socket head cap screws) HSE: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( or 6 pcs of M5 hex socket head cap screws) (HS9Z-A/A) 5.0±0.5 N-m (approx. 50±5 kgf cm) ( pcs. of M6 hex socket head cap screws) (HS9Z-A5/A5).0±0. N-m (approx. 0± kgf cm) ( pcs of M hex socket head cap screws).0±0. N-m (approx. 0± kgf cm) ( pcs of M Phillips screws) The screws are supplied by the user. Applicable Wire Size HSC: 0.5 to 0.75 mm (Terminals No.,, 5 to 8).0 to.5 mm (Terminals No.3,, and grounding terminal) HS5B: 0.5 to.5 mm HSE: 0.5 to.5 mm 9 mm max. 30 mm max. Overview X Series E-Stops Door Interlock Switches Enabling Switches Barriers AS-Interface Safety at Work

AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview Angle Adjustment Using the screw (M3 hex socket head screw), the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: (0 ) to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. Minimum Radius of Hinged Door When using the interlock switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (HS9Z-A55). Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A5 When the door hinge is on the extension line of the interlock switch surface: When door hinge is on the extension line of the actuator mounting surface: When using the HS9Z-A55 Angle Adjustable When door hinge is on the extension line of the interlock switch surface: 50 mm When door hinge is on the extension line of the actuator mounting surface: 70 mm Use a cable gland with a degree of protection IP67 G/, PG3.5, M0 9 max. When Using Flexible Conduits (Example) Flexible conduit example: VF-03 (Nihon Flex) Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ RLC-03 (Nihon Flex) PG3.5 RBC-03PG3.5 (Nihon Flex) M0 RLC-03EC0 (Nihon Flex) 30 max. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the entry slot of the safety switch. Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm) After adjusting the actuator angle, apply loctite or the like to the adjustment screw so as to prevent its loosening. Horizontal Swing Vertical Swing Applicable Cable Glands all dimensions in mm Angle Adjustment for the HS9Z-A55 Using the angle adjustment screw, the actuator angle can be adjusted (see figures on page 370. Adjustable angle: 0 to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the interlock switch. After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not loosen. When Using Multi-core Cables (Example) Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ SCS-0* (Seiwa Electric) PG3.5 ST3.5 (K-MECS) M0 ST-M0X.5 (K-MECS) ALS-6** (Nihon Flex) ABS-**PG3.5 (Nihon Flex) ALS-**EC0 (Nihon Flex) Different cable glands are used depending on the cable sheath outside diameter. When purchasing a cable gland, confirm that the cable gland is applicable to the cable sheath outside diameter. When using a /-NPT cable gland, use the HS5B interlock switch with M0 conduit port (Part No.: HS5B-***BM) together with an adapter (Part No.: MA-M/NPT 0X.5 5-00, K-MECS) and a gasket (Part No.: GP M0, K-MECS). Install a gasket between the interlock switch and the adapter. Apply sealing tape between the cable gland and the adapter to make sure of IP67 protection for the enclosure.