Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Similar documents
display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control

INSERTION flow sensor for continuous flow measurement

Paddle-wheel flow controller with optical principle for On/Off control

Inline Paddle Wheel Flow Switch

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Insertion magnetic inductive flowmeter

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Flow switches for insertion installation

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Solenoid valve. Technical data Orifice 1/4 4 Body materials Actuator material Seal material Media Viscosity. Control medium Port connections

Digital ph transmitter

2/2-way Solenoid Valve with servo diaphragm

Digital ph transmitter

Advantages. Options VHS06

Positive displacement flowmeter for continuous flow measurement

INSERTION flowmeter with paddle wheel, ELEMENT design

INSERTION Adaptor for analysis

Fluid Control System with Quarter-Turn Ball Valve for normal, aggressive and ultra-pure fluids. TOP Control System 265X

Inductive conductivity meter

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

INLINE fitting with paddle-wheel for flow measurement

Level switches Series LC40 Float level switch for liquids

Miniature Float Switches

Direct-acting 2/2-way plunger valve

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

INLINE fitting with paddle-wheel for flow measurement

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material

Simple float switch TCL001/8181

INLINE sensor-fitting with paddle wheel for flow measurement

2/2 or 3/2 way direct acting rocker solenoid valve

Flowmeter DFM

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Operating Instructions for Plastic Flow Meter. Model: KSK

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

flow switches J with pipe tees (inline) J Direct installation (insertion) J for hvac applications J with interchangeable paddles J For air flow

Plastic tube variable area flowmeter for liquids and gases

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

FLOW SWITCHES. With pipe tees (inline) Direct installation (insertion) For OEM applications Flow monitors. Including products with:

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

Flap-Type Flow Meter Prall

For industrial applications For marine applications With proximity switch. Piston type flow switches

2/2- and 3/2-way solenoid valve for aggressive fluids

Positive displacement batch controller

Flow switches Series AD/VH

2/2-way Globe Valve for media up to +180 C, DN

Direct-acting 2/2- or 3/2-way pivoted armature valve

Fluid Control System with Diaphragm Valve For Polluted, Dirty, Aggressive and Ultra-Pure Fluids

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Inductive conductivity meter

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

2/2-way Solenoid Valve for liquids and gases

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

Signet 2551 Magmeter Flow Sensor

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

PSF50 Paddle flow switch

SIKA Flow Switches -1-

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

KM-165, KM-185, KM-200 OVERVIEW. Flow Monitor & Flow Indicator. Features. Operation

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

2/2-way Globe Valve for media up to +180 C, DN

Servo-operated 2/2-way solenoid valves Type EV220A

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

Cable Plug acc. to DIN EN , Form A

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Probe holders for analytical probes

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

SIKA Flow Switches -1-

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

flow x3 flow monitoring

DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

Direct-acting 3/2 way plunger valve

HYDRUS ULTRASONIC METER

3/2-way Solenoid Valve, direct-acting, NC or NO

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

3/2-way Solenoid Valve for pneumatics

PROCESS & AUTOMATED VALVES

Clogging Indicators. Description. Page 393. Application Monitoring the contamination of pressure and high pressure filters.

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

2/2 Pressure operated valves

,

Wafer check valve RSK 500

Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide

FLOWX3 F3.60M.S Insertion Magmeter

Function Continuous control version: Type 8630 Position control or process control with an integrated PID controller

Ordering Guide. Ordering Guide. May Water Control Solutions

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

Transcription:

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control INLINE Quarter-Turn ON/OFF Control System for Monitoring and Switching Mechanical adjustment of set point No contact to Fluid thanks to INLINE Quarterturn Technique This mechanical single paddle Sensor/Switch is specially designed for monitoring minimum/maximum values of flow. The switching point can be set by turning a spring screw. The switching is done by a moving magnet and a reed contact. The connection to the process in the piping is done with the easy to connect quarter-turn technique of the INLINE fittings. Process Specification Pipe diameter DN 5 DN Switching range see table Fitting Bürkert INLINE fitting S Housing material PC+% glass fiber Sensor element reed contact on single paddle Monitoring - Min./Max. values Electrical Specification Reed contact output: Max. switching voltage Max. switching current Max switching power Recommended max. cable length 3 VDC, VAC A W m shielded, section.4...5 mm Alarm Valve Electrical Connections Optional EaseOn cable plug Cable plug 3 wire, plug in-turn off DIN 436A Environment Specifications Fluid temperature max. 55 C Ambient temperature max. +55 C Fluid pressure max. PVC, PP, PVDF: PN Metal fitting: PN6 Type of protection IP 65 with connector pluged in Standards EMI EN 8-, 8-, - Fluid Control Systems

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control Ordering table for SE (electronic SE and sensor fitting S build the ) ON/OFF Flow Control System, mechanical, magnetic paddle INLINE type Output Connector Item-No. read contact NO Connector cable plug DIN, PG9 438 87 L read contact NC Connector cable plug DIN, PG9 438 88 V Fittings with Magnetic Sensor Paddle - PVC, PVDF, PP, Stainless Steel or Brass (see datasheet fittings S) Dimensions Variable dimensions Magnetic paddle flow switch type Range Fitting Fluid velocity (water) Flow rate or DN (m/s) (l/mn) (m 3 /h) (mm) min max min max min max 5.65 ->.9 6.9 9.5.4.57 75 5. <-. 6.4 8.5.38.5 48.5.35 ->.55 6.6.4..6.5 <-.45 4.7 8.5.8.5 3.8 ->.8 8.5 3.5.5.8 3.5 <-. 7..5.4.63 3 5. ->..8 7.7.7.6 5.3 <-. 8.8 4.7.53.88.5 ->.45 8.8 33.9.3.4. <-.35 5. 6.4.9.58 3.65 ->.9 3.4 43.4.88.6 44 3.55 <-.7 6.5 33.8.59.3.49 ->.59 58. 7. 3.48 4. 54.36 <-.5 4...5 3..75 ->. 56.5 75.4 3.39 4.5. <-.9 45. 67.9.7 4.7 Electrical connection - Reed contact version Switching range table for fitting PVC, PVDF, PP, SS, Brass for DC switching use free wheeling diode to avoid sparking on the reed relay contact. SE reed contact D Load Z free wheeling diode Switching range Switching range 7 7 for switching of high capacitive loads (like lamps, long lines, )use a current limiting resistor. SE reed contact not connected + - see instruction manual /SE for more details R Load 3 Flow rate increases Flow rate decreases 3 Flow rate increases Flow rate decreases Reed contact Reed contact 3 not connected DN5 DN DN5 DN3 DN DN3 DN DN In case of special application requirements, please consult for advice. We reserve the right to make technical changes without notice. 9-GB/ -96

S BRASS, INLINE Quarter-Turn ON/OFF Control System for Monitoring and Switching in Combination with SE unit No Leakage due to Single Paddle inside the fitting (INLINE Quarter-Turn Technology) Contact Free Switching of Reed Contact by Magnetic Transmission The fitting S has the single paddle to detect the flow built in. This leads to a very leak proof construction, which we call the INLINE Quarter-Turn Technology. The switching point is transmitted contact free by a magnetic field. The detecting unit SE can be snapped-on or removed without opening the pipe of the process. The switching point can be set on the unit SE. Process Specifications Pipe diameter DN 5 up to DN to install Temperatures Ambient Storage Fluid up to +55 C up to +55 C up to +55 C Materials Seal FPM (standard) EPDM (on request) Fitting Brass Screws Stainless Steel (36L -.44) Pressure class PN6 Measuring range (see diagram) Paddle (range ) DN5.65 up to.9 m/s DN.35 up to.55 m/s DN5. up to. m/s DN3.65 up to.9 m/s DN.75 up to. m/s Paddle (range ) DN3. up to.3 m/s DN.5 up to.45 m/s DN. up to. m/s Burkert Quarter Turn Application: (together with SE) Monitoring - Min./Max. Values Alarm Valve Fluid Control Systems

Specifications - Ordering Chart (Other Versions on Request) Description Brass Fitting World Wide with internal threaded port connection with external threaded port connection Orifice DN 5.. 5. 3. 3.. 5.. 5. 3. 3.. Process Connection G / G G /4 G / G /4 G / G G G /4 G / M55 x G / M55 x M64 x Switching Range Item No. 438 63 U 438 64 V 438 65 W 438 66 X 438 67 Y 438 69 A 438 7 F 438 7 U 438 9 U 438 9 R 438 9 J 438 93 K 438 94 L 438 96 N 438 97 P 438 98 Y Brass Fitting ASEAN with internal threaded port connection 5.. 5. 3. 3.. Rc / Rc 3/4 Rc Rc /4 Rc / Rc /4 Rc / Rc 438 8 P 438 8 Q 438 83 R 438 84 J 438 85 K 438 87 M 438 88 W 438 89 X Brass Fitting NAFTA with internal threaded port connection 5.. 5. 3. 3.. NPT / NPT 3/4 NPT NPT /4 NPT / NPT /4 NPT / NPT 438 7 V 438 73 W 438 74 X 438 75 Y 438 76 Z 438 78 B 438 79 C 438 S

Dimensions for Fittings - Brass Fitting with internal threaded port connection Brass C DN 5 DN 5 L G G, Rc and NPT Fitting with external threaded port connection Brass B L G G Orifice DN Internal Threaded Port External Threaded Port Example of type with internal threaded port connection (S + SE) C G L B G L 5 5 5 5 5 5 3 3 3 85. 85. 85. 95. 95. 95. 5. 5. 5.... 3. 3. 3.... G / NPT / Rc / NPT 3/4 Rc 3/4 G NPT Rc G /4 NPT /4 Rc /4 G / NPT / Rc / G NPT Rc 6. 7. 5. 7. 8.3 6.3 3.5 8. 8. 3.5.. 3.5. 9. 7.5 4. 4. 84. 84. 84. 94. 94. 94. 4. 4. 4. 9. 9. 9. 9. 9. 9. 49. 49. 49. G G G G /4 G /4 G /4 G / G / G / M55 x M55 x M55 x M64 x M64 x M64 x.5.5.5 3.5 3.5 3.5 4. 4. 4. 8. 8. 8. 9. 9. 9....

Dimensions for Fittings with Magnetic Sensor Paddle - Brass Example: Fitting with weld ends and SE DN 5 screw for switching point adjustment Switching Range Table for Fitting Brass Switching Range 7 Switching Range 7 Orifice Dimensions DN F 5 5 3. 97. 97.. 5.. F = Center to Top DN 5 F 3 DN5 DN DN5 DN3 DN 3 DN3 DN DN Inner Materials of all Brass Fittings Fitting with internal threaded port connection. Body Brass. Paddle PVDF 3. Shaft Stainless Steel (36L -.44) 4. O-Ring FPM (EPDM on request) 3 4 N 5 In case of special application requirements, please consult for advice. We reserve the right to make technical changes without notice. -GB/ -9