On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E

Similar documents
On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E Pamphlet

Proportional Solenoid for Hydraulics ATEX + IECEX

Proportional Solenoids for Hydraulics G RC Y 037, 045, 063

DC Single-Acting High Performance Solenoids

Electromagnetically actuated shotbolt lock unit G SC X... B01

Proportional solenoid valve for pneumatic application V PR M

Proportional solenoid valve for pneumatic application V PR M

Solenoid Operator 0516 / 1216

Solenoid Operator 0513 / 1213

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Limit switch attachments DAPZ

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

3/2 and 4/2 directional seat valves with solenoid actuation

Solenoid System FLANGE MOUNTING VERSION

GEMÜ 205 Electrically operated solenoid valve

Lifting / Lowering valve type HSV and HZV

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Type 60,61L. Electric Bolt Lock - Industrial

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

COMBISTOP NEW. Spring applied brakes

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Technical Data Sheet

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Directional Control Valve Series D3W Soft Shift

Proportional Solenoids

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Series 26d Ball Valve

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Lifting / Lowering valve type HSV

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

EVI 5 S13 Solenoid System

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot control unit with end position lock for the remote control of directional valves

3/2 and 4/2 directional seat valves with solenoid actuation

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

3/2-way Rocker Solenoid Valve for pneumatic systems

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

System 13. ü ( System 13

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Installation and Operating Instructions for ROBA-stop -silenzio Type 896. _. Sizes

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

System 6. ü ( System 6

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Modulating control valve PN16 with magnetic actuator

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

APPLICATION OF SYSTEM 8

Solenoid coils VACF Type codes

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Lenze. Drives with worm gearboxes 52.

Installation and Operating Instructions for ROBA-stop -silenzio Type 896._3_. Sizes

System Line. AC Single-Stroke Solenoids

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

Operating Instructions

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

3/2-way Solenoid Valve for pneumatics

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Safety for Hydraulics

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

BALL VALVE SERIES Pneumatic actuator - Actreg

97100 NAMUR. Technical data

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

HERION SERIES Indirect solenoid actuated soft seal

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)

Solenoid valves VZWM-L, NPT

System 6. Solenoid Coils Armature Assemblies Valve Systems

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Directional Control Valve Series D1VW

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

Servo solenoid valves with on-board electronics (OBE)

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

To order, quote model number from table overleaf, e. g for a DN 25 valve.

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Transcription:

SPECIALISTS IN ELEKTROMAGNETIC DEVICES QUALITY SINCE 1912 On/Off- Solenoid to RL 94/9/EG (ATEX 95) 4 Product group G HP E To DIN VDE 0580 and RL 94/9/EG (ATEX 95) Pressure-tight armature space, rated operating pressure 250 bar Magnetic force/stroke characteristic Quick floating times Pushing type Mounting via central thread Simple exchange of the coil without opening the hydraulic circuit Coil winding to insulation classification H Electrical connection and protection class if mounted properly: Connection cable Li12Y11Y 3 x 1.5 Protection class to DIN VDE 0470/EN 60 529 - IP67 Explosion protection II 2G EEx m II T4 Supplementation of permission for dust guard, 2D, is being prepared. Manual override Special designs on request Application examples: Actuation of hydraulic and special valves Fig. 1: G HP E 037 AMX A01 Magnet-Schultz GmbH & Co. KG Postfach 1665 D 87686 Memmingen Allgäuer Straße 30 D 87700 Memmingen Telefon ++49 (0) 8331 10 40 Telefax ++49 (0) 8331 10 43 33 info@magnet-schultz.de www.magnet-schultz.com

Technical Data G HP E 037 AMX A01 Operating mode S1 (100 %) FM N Rated Voltage UN Rated Current IB Rated Power P20 Ambient temperature Ta 24 V 0.72 A 17.3 W - 20 to + 50 C 80 70 60 50 40 30 Mounting on hydraulic valve with multiple mounting in single operation: minimum size: 46 x 46 x 66 mm on base plate material: iron or material with equal, or better heat derivation respectively. The indicated technical data refer to a power supply from the A.C. mains supply via bridge rectifier. By appropriate measures it is to be ensured that the given maximum values, especially the control current level, are not exceeded. On request the coil winding can be adjusted to other current and resistance values. The magnetic-force values in the diagram refer to 90 % of the rated voltage (UN = 24 V) and in hot condition, according to DIN VDE 0580. For other voltages the magnetic force may deviate. Owing to natural dispersion the magnetic-force values may deviate by + 10 % from the listed values. On request, the armature space can be de-aerated and the pushrod can be adjusted. Mech. modifications of the flange are possible on request. The solenoid interior and armature bearing are resistant to all neutral fluids that are commonly used in hydraulics. Please contact us if you intend to use other operating media. 20 10 0 0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 s mm Fig. 2: magnetic force / stroke characteristic G HP E 037 AMX A01 Please notice the relevant operating manuals which are delivered with each device. An EC declaration of conformity of the manufacturer is enclosed once. Please be sure that this device ist suitable for your application. We kindly ask to notice the DIN EN 60079-14 for the application. Note on the RoHS guideline 2002/95/ EC The devices presented in this document do not fall into the scope of regulation 2002/95/EC ( RoHS ) and do not become part of products which fall into the scope according to our state of information. In case of surfaces zinc coating with yellow chromating and zinc iron with black chromating separate agreements are necessary for application according RoHS. 2 The edition of the present pamphlet cancels the former ones.

Magnetic Body (dimensions for your information) disc min. 0.1 jutted out Fig. 3: Coil 924618 (FHMPE037924618) inscription according to LB924617 37 Tube (dimensions for your information) closing torque 12 tp 14 Nm emergency manual override actuation force max. 20 N without pressure energized armature Fig. 4: Tube 923692 (FHTP037923692) 3

Proportional Solenoid, complete cable + end sleeve DIN 46228 - A 1.5-7 connecting line Li12Y11Y 3 x 1.5 mm² round sealing ring 19 x 2.5 70 Sh-A NBR FHTS923692 FHMSE037924617 fixing nut closing torque 5 +1 Nm fitting socket wrench set SW 26 (12 kt DIN 3124) Fig. 5: Proportional Solenoid G HP E 037 AMX A01 Wiring diagram The solenoid shown is not a ready-to-use device in the sense of DIN VDE 0580. The general requirements and protective measures to be taken by the user, are included in DIN VDE 0580. The use of the shown device in safety relevant applications needs always the written agreement of MSM. 4

Single Components consecutive number quantity description Ident-No. 1 1 magnetic body f. 24 VDC FHMSE924617-001 2 1 tube FHTS037923692 3 1 round sealing ring 19 x 2.5 70 Sh-A NBR 781754 4 1 fixing nut 472793 Fixing Nut Fig. 6: Fixing Nut 472793 suitable socket wrench SW26 (bihex DIN 3124) O-Ring to be used: 19 x 2.5 70 Shore A closing torque 5 +1 Nm 5

Type code Equipment group Basic construction Modifications Size Arrangement Basic protection Design number G HP E 037 A MX A01 Only available as complete unit! Order Example Type G HP E 037 AMX A01 Voltage 24 V DC Operating mode S1 (100 %) Specials Please do not hesitate to ask us for application-oriented problem solutions. In order to find rapidly a reliable solution we need complete details about your application conditions. The details should be specified as precisely as possible in accordance with the relevant - technical explanations. If necessary, please request the support of our corresponding technical office. Subject to our standard conditions. 6 Printed in Germany 022008/04 Ss