Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Similar documents
Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

Model Number Structure

Small Limit Switch D4V

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Subminiature Basic Switch

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Manual Reset Limit Switch

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Safety Limit Switch

Pre-wired Models D4C- (1) (2) (3) (4)

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

HL (AZH) LIMIT SWITCHES

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Safety-door Switch. Ordering Information

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Multiple Plunger Limit Switch

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Model Number Structure

HL (AZH) Limit Switches

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Hinged Safety Door Switch

Miniature Limit Switches

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

Multiple Limit Switch

Ordering Information. Text PCB Power Relay G5LE

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Safety Limit Switch

OMRON Z LIMIT SWITCH

2NC (slow-action) Direct. Model. opening

HL (AZH) Limit Switches

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Model Number Structure

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

Robust General-Purpose Limit Switch WL

SL (AZ3) Micro Limit Switches

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications.

Model Number Structure

Subminiature Basic Switch

AM1 (NZ BASIC) SWITCHES

Best-selling Basic Switch Boasting High Precision and Wide Variety

DL (AZD1) Mini Limit Switches

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Inductive Proximity Sensor

Best-selling Basic Switch Boasting High Precision and Wide Variety

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

D4DL. Guard Lock Safety-door Switch. Model Number Structure

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

Model Number Structure

Switching Power Supply

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

BZSeries. Basic Switches

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form

Mechanical Key Switch

Low-torque Basic Switch

Installation Instructions: K-Safe-T-Drift

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

LJASeries. Limit Switches with Positive Opening Mechanism

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

BZSeries. Basic Switches

Limit Switches with Positive Opening Mechanism

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

A22NK. Key-type Selector Switches

SL1Series. Compact Horizontal Limit Switches

Best-selling Basic Switch Boasting High Precision and Wide Variety

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Transcription:

Enclosed Switch Economical, High Utility Enclosed Switch High precision and long life (10,000,000 mechanical operations) through employment of the moving spring used in OMRON Z Basic Switch. Sealed with gasket diaphragm to provide high sealing property without use of any adhesive or pin. Suitable for applications demanding higher mechanical strength, dustproof and drip-proof properties than those on basic switches. Panel mount versions have the same operating position as Z Basic Switch. Resin molded terminal versions are available. Ordering Information Model Number Legend - 1 1. Actuator 5000: Panel mount plunger 5020: Panel mount roller plunger 5040: Panel mount crossroller plunger 1020: Short hinge lever 1000: Hinge lever 2000: Hinge roller lever 2020: Short hinge roller lever 3030: One-way action short hinge roller lever List of Models Panel mount plunger Actuator -5000 Model Panel mount roller plunger Panel mount crossroller plunger Short hinge lever Hinge lever Hinge roller lever -5020-5040 -1020-1000 -2000 Short hinge roller lever -2020 One-way action short hinge roller lever -3030 1. Use molded terminal models (refer to page 209) when using the Switch under one of the following conditions: a) dusty, b) high amount of dripping oil, or c) high humidity 2. Micro-load models are available. e.g. Standard model Micro-load model -5020-5020-C 1

Specifications Ratings Rated voltage Non-inductive load Inductive load Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 125 VAC 10 A 3 A 1.5 A 10 A 5 A 2.5 A 250 VAC 10 A 2.5 A 1.25 A 10 A 3 A 1.5 A 480 VAC 3 A 1.5 A 0.75 A 2.5 A 1.5 A 0.75 A 8 VDC 10 A 3 A 1.5 A 6 A 5 A 2.5 A 14 VDC 10 A 3 A 1.5 A 6 A 5 A 2.5 A 30 VDC 6 A 3 A 1.5 A 5 A 5 A 2.5 A 125 VDC 0.5 A 0.4 A 0.05 A 0.05 A 250 VDC 0.25 A 0.2 A 0.03 A 0.03 A Inrush current NC 30 A max. NO A max. 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. Lamp load has an inrush current of 10 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current. 5. The above ratings were tested under the following conditions according to JIS C4508. Ambient temperature: 20±2 C Ambient humidity: 65±5% Operating frequency: 20 operations/min Approved Standard Ratings UL/CSA A300 Rated voltage Carry current Current Volt-amperes Make Break Make Break 120 VAC 10 A 60 A 6 A 7,200 VA 720 VA 240 VAC Micro load: 0.1 A, 125 VAC 0.1 A, 30 VDC EN60947-1 and EN60947-5-1 250 V, 10 A (AC-12) 30 A 3 A 2

Characteristics Degree of protection Life expectancy Operating speed Operating frequency Insulation resistance Contact resistance Dielectric strength Rated insulation voltage (U i ) Pollution degree (operating environment) Protection against electric shock IP67 (NEMA250: 6.6P) Mechanical: 10,000,000 operations min. Electrical: 500,000 operations min. 0.05 mm/s to 0.5 m/s (at panel mount plunger) Mechanical: 120 operations/min Electrical: 20 operations/min 100 MΩ min. (at 500 VDC) mω max. (initial value) 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and non-current-carrying part 1,000 VAC 3 (IEC947-5-1) Class II PTI (tracking characteristics) 175 Switch category Rated operating current (I e ) Rated operating voltage (U e ) Vibration resistance Shock resistance Ambient temperature D (IEC335) 10 A 250 VAC Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note) Destruction: 1,000 m/s 2 min. Malfunction: 100 m/s 2 min. (in case of plunger) (see note) Operating: 10 C to 80 C (with no icing) Ambient humidity Operating: 35% to 95% Weight Approx. 71 g (at panel mount plunger) Less than 1 ms under a free state at the operating limits. Approved Standards (Except Molded Models) UL (File No. E76675)/CSA (File No. E45258) Operating Characteristics Model -5000-5020 -5040-1020 -1000-2000 -2020-3030 OF 5.88 N 5.88 N 2.55 N 1.67 N 1.96 N 2.94 N 2.94 N max. RF min. 0.98 N 0.98 N 0.34 N 0.25 N 0.39 N 0.39 N 0.39 N PT max. 1.6 mm 1.6 mm --- --- --- --- --- OT min. 5 mm 5 mm 2.5 mm 4 mm 5 mm 2 mm 2 mm MD 0.2 mm 0.2 mm 1.7 mm 3 mm 3 mm 1.5 mm 1.5 mm max. OP 21.8± 33.4±1.2 mm 25±1 mm 25±1 mm 40±1 mm 40±1 mm 50±1 mm 1.2 mm FP max. --- --- 33 mm 36 mm 51 mm 47 mm 57.2 mm 3

Engineering Data (Reference Data) Life expectancy (x 10 4 operations) Mechanical Life Expectancy (-5000) 10,000 5,000 2,000 1,000 500 200 Operating temperature: 20±2 C Operating humidity: 65±5% No load Operating frequency: 120 operations/min 100 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 10 Overtravel (mm) Operation Contact Form Life expectancy (x 10 4 operations) Electrical Life Expectancy 10,000 7,000 5,000 3,000 1,000 700 500 300 100 70 50 30 10 0 2 125 VAC cosφ=1 125 VAC cosφ=0.4 Operating temperature: 20±2 C Operating humidity: 65±5% Operating frequency: 20 operations/min 4 250 VAC cosφ=1 250 VAC cosφ=0.4 6 8 10 12 COM NO NC Dimensions 1. All units are in millimeters unless otherwise indicated. 2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Panel Mount Plunger -5000 (See note 2) 16 dia. (See note 1) M12 x 1 mounting screw Two hexagon nuts (thickness: 3 width: 17) 8.4 dia. 1. Stainless steel plunger 2. The length of the imperfect threads is 1.5 mm maximum. Panel Mount Roller Plunger -5020 12.7 dia. 5 (See note 2) 16 dia. M12 x 1 mounting screw Two hexagon nuts (thickness: 3 width: 17) 1. Stainless steel roller 2. The length of the imperfect threads is 1.5 mm maximum. 4

Panel Mount Crossroller Plunger -5040 M12 x 1 mounting screw Two hexagon nuts (thickness: 3 width: 17) 12.7 dia. 5 (See note 2) 16 dia. 1. Stainless steel roller 2. The length of the imperfect threads is 1.5 mm maximum. Short Hinge Lever -1020 t = 1 (see note) Stainless steel lever Hinge Lever -1000 t = 1 (see note) Stainless steel lever Hinge Roller Lever -2000 t = 1 12.7 dia. 7.5 (see note 2) 1. Stainless steel lever 2. Plastic roller Short Hinge Roller Lever -2020 t = 1 12.7 dia. 7.5 (see note 2) 1. Stainless steel lever 2. Plastic roller 5

One-way Action Short Hinge Roller Lever -3030 t = 1 Angle of roller swing: 90 14 12.7 dia. 7.5 (see note 2) 1. Stainless steel lever 2. Plastic roller Mounting Holes Two 4.3 dia. or M4 screw holes 25.4 ± 0. Molded Models Molded Models The molded terminal model is available with right-hand, left-hand and underside leads and is recommended for use where the Switch is exposed to dust, oil, or moisture. (2) Leads Supplied Leads (3) (1) Nominal cross-sectional area When placing your order for the Switch specify the required length of V.C.T. cable in addition to the model number of the Switch Example: Standard type: -5040 Location of lead outlet: Underside Length of lead: 1 m (V.C.T. lead) When placing your order for the above Switch specify the model number as -5043 (V.C.T 1 m) Suffix by Location of Lead Outlet Location of lead outlet Right-hand Left-hand Underside Finished outside diameter connections V.C.T. (Vinyl cabtire cable) 1.25 mm 2 Triple conductor: 10.5 mm dia. Black: COM White: NO Red: NC Model COM, NC, and NO - 1-2 - 3 Standard length 1, 3, 5 m Protective Cover ZC55 Cover (ZC55-0002H): The following three parts are supplied as a set. ZC Seal Rubber (SC-1404C) Rubber packing Seal rubber 6

Precautions Correct Use Operating Method Excessive dog angle, operating speed, or overtravel (OT) may damage the actuator. Check that OT has a sufficient margin. The actual OT should be rated OT x 0.7 to 1. Handling Do not expose the Switch to water exceeding 60 C or use it in steam. Do not use the Switch in oil or water. An 8.5- to 10.5-dia. cable can be applied as seal rubber for the lead wire outlet. (Use two- or three-core cable of VCT1.25 mm 2.) When detaching the Protective Cover, insert a screwdriver and apply a force in the opening direction. Do not use excess force to remove the. Doing so may cause deformation in the fitting section and reduce the holding force. Screwdriver Mounting When mounting the Switch with screws on a side surface, fasten the Switch with M4 screws and use washers, spring washers, etc., to ensure secure mounting. Mounting Holes Two, 4.3-dia. or M4 screw holes When mounting the Panel Mount-type Switch (DCMC-5000, 5020, or 5040) with screws on a side surface, remove the hexagonal nuts from the actuator. When mounting the panel mount type on a panel, be careful not to tighten to an excessive torque. Tightening the screws to a torque exceeding 4.91 N m will cause the plunger to fail. Mounting Hole Dimensions -5000-5020, 5040 12.5 +0.2 0 dia. 12.5 +0.2 0 dia. 5 +0.2 0 Protective Cover 13 +0.2 0 When mounting the Protective Cover to the case, align the on the case and then press the down to mount it firmly. If the is pressed down in an inclined position, rubber packing will deform and thus affect the sealing capability. Correct Tightening Torque A loose screw may cause malfunctions. Be sure to tighten each screw to the proper tightening torque as shown in the table. No. Type Torque 1 screw 0.78 to 1.18 N m 2 Panel mounting screw 2.94 to 4.92 N m 3 Side mounting screw 1.18 to 1.47 N m Rubber packing Rubber packing ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. C027-E1-7 7