Electrak powertrack / underfloor busbar system

Similar documents
adaptable, reliable underfloor power

Electrak power track underfloor power distribution systems

Underfloor Busbar. Betatrak Underfloor Busbar. 82

Underfloor to desk 231

Betatrak Compliance Standard

Arena-Walsall power track system standard

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

FLOOR DISTRIBUTION SYSTEMS

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

Snake Bus Power Distribution

Calculation of the Cross-sectional Areas of Circuit Live Conductors

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

Interact Underfloor Power

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

KAP A Plug-in Busbar Distribution System IEC ME 04

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Floor boxes... choice, flexibility and easy installation

PART 10 ELECTRICAL INSTALLATIONS

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

PSU EN54-4 Power Supplies

elevate your flexibility

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

DX³ RCCBs - ID 4P up to 100 A

Electronic Circuit Breaker ESS20-0..

PART 8 ELECTRICAL INSTALLATIONS

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

Powerline. Single Power Connectors. Ten 47 Limited

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

ype UP T Busplugs Low Voltage Switchboard Equipment

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on right side

STERLING BUSBAR. Sterling Busbar is cable management made easy. It is a 63Amp. single phase system for use in standard or clean earth power

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Powerline QC. Single Power Connectors. Ten 47 Limited

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

Cellwatch Electrical Installation

Duraplug. wiring devices portable power

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

Plexo 3 weatherproof cabinets

SELECT MEMBERSHIP NUMBER Full Installation 75% new and 25% alteration to exsisting

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET

DX³ 4-pole RCBO 6000 A/10 ka

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

WavePro LT Busway Cost effective solution for electrical distribution

TX³ RCCBs 2P up to 100 A

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

FR-3S Fire Resistant Cables

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

Floor outlet boxes British Standard

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

BUSBAR TRUNKING SYSTEMS a

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

Powerline. Single Power Connectors. + Ten 47. Ten 47 Limited

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

DX³ RCBO 6000 A Phase + Neutral, neutral right side

FUSEHOLDERS. Type Fuse Size (mm) Page. Type Fuse Size (mm) Page

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

EC400 Power Control System

Distribution Blocks & Bus-bar Solutions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

XL Distribution enclosures WORKSHOP SPECIFICATIONS

20 HUBER+SUHNER RADOX SOLAR

Unarmoured Single-Core Cables to BS6883

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

Swifts cable ladder ancillary items

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Electrical. Earthing & Bonding. Installation Techniques. Learning Notes MODULE 2.2 UNIT PHASE:2

Viking 3 - Screw connection Disconnect terminal blocks

Snap-in covers I Voltage taps

THERMOCOUPLE CABLES THERMOELECTRICITY

Intelligent Choice for Prestigious Buildings

HX Range Catalogue. Contact. About Anord Mardix.

Electronic Circuit Breaker ESS20

Modular contactors and relays

045 : 2000 CEB STANDARD

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

PY, SPY; FSQC, FP; EPC; AP

Unified requirements for systems with voltages above 1 kv up to 15 kv

8WH2 Spring-Loaded Terminals

MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY

Guidelines How To Wire DRH Modules

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number

Low Voltage Systems. MNS BS - front & rear access switchboards Tested, tried & trusted solutions. Power and productivity for a better world TM

Transcription:

design and installation n General installation notes Electrak powertrack is a compact system that can be installed in floor voids as low as 48 mm Feed units are provided with one or two 25 mm diameter holes suitable for MICC, armoured cables or single core cables in conduit Track lengths connect together and to feed units using the integral connectors on each length Lengths should always be secured using the integral floor fixing brackets ; three on the 3 6 m length and two on 2 4 m, 1 8 m or 1 2 m lengths n Special fixing brackets Electrak special fixing brackets are available to raise the system by 21 mm. Ensure brackets are spaced 600 mm apart and always have support under the integral connectors and feed units. Failure to do so may undermine the integrity of the system Cat. No. DZ1210 raised off-floor fixing brackets are spaced at 600 mm centres along the busbar run. Also use bottom half of bracket under feed unit and flexible interlink Cat. No. DZ1230 raised off-floor fixing brackets are always used under integral connectors. Busbar is secured to raised brackets using the integral fixing bracket Access to power is provided along the busbar length by simply plugging tap-off units into shuttered socket outlets. These tap-off units feed all types of conventional floor service outlet boxes or feed workstations directly through the floor via insulated conductors contained in flexible metal or VO rated nylon conduit. When connecting tap-offs directly through the floor via grommet outlets to workstations care must be taken to ensure that the tap-off length is adequate The dual system has both standard and low noise / clean earth systems incorporated. As well as dual tap-offs, both standard and low noise / clean earth tap-offs can be plugged into any socket outlet along the busbar length. The dual tap-off incorporates both standard and low noise cables Optimum layout flexibility is achieved by positioning busbar lengths a maximum of 5 2 m apart and 2 5 m from the wall, and by connecting the 3 m tap-off units to floor outlet boxes. This means every part of the floor area can be served. Flexible interlinks can be used to overcome obstructions or used as corners if required 99 mm 50 mm Cat. No. DZ1210 7 mm Ø Integral connector 21 mm to underside and 36 mm to top of busbar length Integral fixing bracket screws to special bracket 185 mm Cat. No. DZ1230 7 mm Ø n Dimensions 93 75 250 109 118 68 46 46 47 32 15 2 x 25 Ø 25 Ø 65 End view A End view B 92 Integral fixing bracket fixing centres Example floor layout 2 5 m 5 2 m socket outlet points every 300 or 600 mm along busbar run 5 2 m 3 m flexible tap-off unit floor service outlet box feed unit 5 2 m integral connectors 18

n Product configuration Flexible interlink Flexible interlink boxes must be securely fixed inline to surface so no movement can take place after fixing Depress tap-off side clips and push down Tap-off Push down Side clip Remove dust cover from end entry socket before use Interlink feed entry socket. Remove dust cover label Make sure both tapoff side clips are fully pushed home on both sides of tthe bar Screw fix to surface Feed unit (Cat. No. DF1010) Sub-cabling. Feed unit (Cat. No. JF2010 and JF2010R) Sub-cabling Clean earth 19

design and installation (continued) n Product configuration (continued) Feed unit (Cat. No. KF3010) Sub-cabling Dual tap-off connection (dark green) Protective earth must always be connected via the earth terminal block Feed unit protective earth terminal and earth bond Connections L1, N1, CE = low noise L2, N2, PE = standard Connections L1, N1, CE = low noise L2, N2, PE = standard Clean earth 2 x 25 mm Ø cable conduit fixing hole Feed unit (Cat. No. NF4010) Sub-cabling 3 phase tap-off connection Feed unit (Cat. No. YF5010 and YF5010R) Sub-cabling 20

installation (continued) 1 Fix feed unit to surface Feed unit Direction of busbar run Make chalk line to align busbar lengths 2 Connect busbar length to feed unit Remove dust cover Integral connector Busbar length Push down Feed unit Make sure connector clips are fully pushed home on both sides Push down Additional length 3 Connect additional busbar lengths Remove dust cover before connecting additional lengths First fixing bracket Tap-off outlets reusable plastic dust covers 4 Secure busbar lengths to surface Pull out fixing bracket lugs and screw fix on both sides All integral fixing brackets must be fixed to surface at 1 2 m fixing centres from first bracket on each busbar length 21

technical data n Standards Approved to ASTA Standard 138 BS EN 61534-22 : 2014 and IEC 61534-22 : 2014 Manufactured within an approved ISO 9001 : 2008 and ISO 14001 : 2004 facility Assessed Quality Assurance Certificate No. 2029 Electrak powertrack / underfloor busbar fully complies with the requirements of BS 7671 : 2008 + AMD 3 : 2015 (IET Wiring Regulations) n Ambient temperature rating factors The current carrying capacity for a powertrack / underfloor busbar (In) is affected by the ambient temperature For Electrak powertrack / underfloor busbar the ambient rating factor Ka is equal to 1 for ambient temperatures up to and including 35 C Iz = Ka In Where : Iz = effective current carrying capacity for continuous service under particular installation conditions Ka = ambient temperature factor In = nominal current carrying capacity For ambient temperatures exceeding 35 C the values of Ka and Iz are given in the following tables Powertrack / underfloor busbar system Ambient 20 C 25 C 30 C 35 C 40 C 45 C 50 C Ka 1 0 95 0 85 0 80 Iz 63 A 59 A 53 A 50 A 32 A unfused tap-off (using thermosetting 90 C cables) Ambient 20 C 25 C 30 C 35 C 40 C 45 C 50 C Ka 1 0 95 0 85 0 80 Iz 32 A 30 A 27 A 25 A 13 A fused tap-off (using 2 5 mm 2 thermosetting 90 C cables) Ambient 20 C 25 C 30 C 35 C 40 C 45 C 50 C Ka 1 Iz 13 A n Earth fault loop impedance BS 7671 : 2008 + AMD 3 : 2015 IET Wiring Regulations require accurate determination of the total earth loop impedance, which must be sufficiently low to allow the protective device to operate within the specified time, which for socket outlets is 0 4 seconds. The values relevant to Electrak for calculating the earth fault loop impedance are shown in the electrical test data table, see opposite n Durability Electrak systems are superbly designed and extremely robust. They can be expected to stand up to all normal site conditions. Electrak powertrack / underfloor busbar has been short circuit strength tested by ASTA n Installations with high protective conductor currents All unfused tap-offs comply with Regulation 543 7 without the need for additional earth conductors. Regulation 543 7 1 103 (ii) states a single copper protective conductor having a cross-sectional area of not less than 4 mm 2, complying with the requirements of Regulations 543 2 and 543 3, the protective conductor being enclosed to provide additional protection against mechanical damage, for example, within a flexible conduit For installations with high protective conductor currents requiring fused tap-offs, a 543 7 compliant tap-off must be used. Normally fused tap-offs incorporate 1 5 mm 2 conductors, however in our fused 543 7 tap-offs, the 1 5 mm 2 earth conductor is replaced with a 4 mm 2 conductor and are therefore compliant with Section 543 7 1 103 (ii) n 32 A tap-off unit The 3 m 32 A tap-off unit comprises an unfused tap-off with 2 6 m of flexible metal conduit with integral 4 mm 2 LSOH conductors These units are designed to comply with regulation 434 2 1 of the IET Wiring Regulations by virtue of the following : maximum length of cable is 3 m it is factory assembled and fully tested item with cable installed in high quality Fault condition protection for the tap-off assembly and the floor box socket outlets is delivered by the circuit protection device Disconnection time for socket outlets is 0 4 seconds (Regulation 411 3 2 2). The Electrak system meets this requirement Tap-off units in excess of 3 m should only be used if they contain a fuse or the busbar run is protected by a protective device not exceeding 32 A References : BS 7671 : 2008 incorporating amendment No. 3 : 2015 Appendix 8 Current carrying capacity for powertrack systems Appendix 4 Table 4B1 Rating factors for thermosetting cables Appendix 4 Table 4E1A Single core 90 C thermosetting insulated cables (non-armoured) 22

Volt drops (live and neutral) Busbars 3 0 mv/a/m Cable connector 0 4 mv/a Integral connector 0 4 mv/a 32 A tap-off 0 4 mv/a + 4 mm 2 cable 11 mv/a/m Flexible corner assembly 1 5 mv/a + 10 mm 2 cable 4 0 mv/a/m Mechanical data E24 E28 E28R Number of conductors 3-6 3 Busbar conductor cross sectional area 13 mm 2 13 mm 2 Housing cross sectional area (copper equivalent) 13 mm 2 13 mm 2 Cable terminal capacity 16 mm 2 16 mm 2 Tap-off cable 32 A 4 mm 2 4 mm 2 Tap-off cable 13 A fused 1 5 mm 2 2 5 mm 2 Tap-off conduit, up to 4 conductors 16 mmø 20 mmø Tap-off conduit, 5 and 6 conductors 20 mm 2 N/A Flexible corner cable (tri-rated, high temperature) 10 mm 2 10 mm 2 Flexible corner conduit 25 mmø 25 mmø IP rating 40 40 Earth fault loop impedance Phase busbar 1 5 mω/m Earth busbar 1 5 mω/m Earth housing 1 1 mω/m Earth busbar and housing 0 8 mω/m Cable connector 0 4 mω Integral connector 0 6 mω 32 A tap-off 0 6 mω + 4 mm 2 cable 11 mω/m Flexible corner assembly 1 5 mω + 10 mm 2 cable 4 0 mω/m Rated conditional short-circuit current 16 KA Ambient temperature 25 C Electrical test data Rated current 63 A Rated voltage 230/400 V~ Frequency 50/60 Hz Conductor resistance - live and neutral 3 0 mω/m Conductor impedance 1 5 mω/m Material specifications Housing - busbar lengths Galvanised steel, natural finish Busbars High conductivity copper (Tinned version is electro-tin plated) Busbar insulator PTFE Integral connectors / Tap-off outlets Flame retardant polycarbonate Tap-off outlet entry shutter Acetal Tap-off housing Flame retardant polycarbonate Integral connector blades Copper (Tinned version is plated) Tap-off blades Copper (Tinned version is plated) Tap-off/flexible corner conduit, metal Electro-galvanised steel Tap-off cable LSOH to BS 7211 Flexible interlink cable Tri-rated to BS 6231 Feed box/flexible interlink boxes Galvanised steel Feed connector terminals/earth block Brass (Tinned version is plated) Fixing brackets Galvanised steel 13 A tap-off, fuse To BS 1362, ASTA approved 23