INTEGRID TRACK (120V) SPECIFICATIONS

Similar documents
SURFACE TRACK (120/250V) SPECIFICATIONS

RECESSED TRACK (120V) SPECIFICATIONS

MOUNTING SYSTEMS SPECIFICATIONS

GEMINI HOUSING SPECIFICATIONS

SURFACE CONTROLTrack SPECIFICATIONS

LSI 20 Series 30A, 120V Surface Busway Components 1

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

IMPORTANT SAFETY INSTRUCTIONS

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

NT-300 Series Single Circuit Track System & Accessories

COMPACT BUSWAY 40 & 60 AMP HOUSING

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

INSTALLATION INSTRUCTION W Track Suspension system

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

RELOC Modular Wiring Specialty Lighting and Power Systems

PDI PowerWave 2 Bus System

poollux Power plx-pw60 & plx-pw100

BUSWAY Low Voltage (Pow-R-Flex)

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

Snake Bus Power Distribution

Installation Instruction

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

ELECTRO-MECH SCOREBOARD CO.

Busway Construction. Bus Bars

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

2 CIRCUIT TRACK. Notes: INSTALLATION PROFILE SURFACE TRACK COLOR. Page 1/9. Date :12/06/17 Rev.02 WHITE POWDER COAT SILVER ANODIZED

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Museum Alkmaar - Alkmaar, Netherlands

Product Selection Guide

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Generator Fire Safety: Generator assemblies should be located outside the building.

LED Recessed Troffer Retrofit Kit

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

SECTION PANELBOARDS

Photovoltaic Solar Plan Review

Pow-R-Flex low ampere busway

North America Phase Converters & Electrical Supply

M36 LED Recessed Quickship

PROFILE 50 Up 50 Dn PF1-E. Luminaire PROFILE - 50 UP 50 DN LaED (PF1-E) Type. Project. Product. Notes. Performance Summary

LB - LIGHTING BUSWAY 25-40A

RECESSED WALL WASH MOUNT

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B

Cetra Assembly Instructions

Ciros P-ID-5200 Pendant-Mounted Indirect/Direct

Catalog # Project. Comments. Prepared by. L653 L =12'Nominal Actual length: 140-1/8" [3559mm] W=1 3/8" [3559mm] H =11/16" [17.5mm]

Alphabet By Ledra Brands

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Juno Trac-Lites System A complete and customizable track system with an array of features

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

Industrial Control Transformers

SAVE THESE INSTRUCTIONS

A B C D E F. Tools Required (supplied by others)

Lighting Systems Argus-7

PERIMETER - RECESSED. Regressed 3" BMPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

PERIMETER - RECESSED. Flush BBPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

LIGHTPLANE 1 RECESSED - LP1R

2016 Photovoltaic Solar System Plan Review List

Electric Range installation manual

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

6 Omnitrack 02_Omnit _15.indd 6 27/04/15 13:18

25 kv Apparatus Bushings

New Product Bulletin. PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Lumination TM LED Luminaire LUR Series

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

168 Georgetown Road Canonsburg, PA USA Phone: Toll Free: Fax:

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

INSTALLATION INSTRUCTIONS HYLYTR WALL GRAZER

FACT SHEET Standard: Electrical Safety

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

SURFACE FLUSH FLUSH 5 1 / / /4 2 1 /16

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

RECESSED ASYMMETRIC MOUNT

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

Installation Instructions Central Battery Units

Technical Installation Manual

PROFILE 100 Dn PF1-B. Luminaire PROFILE DN LED (PF1-B) Type. Project. Product. Notes. Performance Summary

MASTERsine Inverter PXA Series Installation Guide

Project. Type. Notes. C custom UNV universal BI bi-level dimming +NL(#) night light circuit (7) O other (6) +GTD(#) generator transfer device (7)

Trac 12/25 and Trac 12 Systems. Two uniquely qualified systems to accept Trac 12 Fixtures

Spring-loaded cover seats against neoprene gasket.

Design Standard. Purpose: Design Standard:

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

Transcription:

INTEGRID TRACK (120V) SPECIFICATIONS GENERAL Integrid Track shall be a combination Track and main runner for mech - anically supporting suspended ceiling systems. Integrid Track shall allow fixtures to be easily focused, switched, dimmed, accessorized and removed as desired. Integrid Track system shall have a twelve year warranty from date of shipment. MECHANICAL Integrid Track shall be constructed of.070 (2mm) extruded alumi num with overall height of 2.19 (56mm) and overall track width of 1.812 (46mm) with overall flange to flange width of 2.50 (64mm). Integrid Track shall have the same overall dimensions and physical appearance for both one and two circuit models. Integrid Track shall be available in 12 foot (3.7m) length, in white high temperature baked paint finish. Integrid Track shall be field cuttable to any length with a single cut. Integrid Track system shall be available with End Feed, End Cap, Straight Mini- Joiner, and Straight Joiner/Feeder as standard components. One Ckt 120V Integrid Track 1 13/16" 1/2" GROUND 2 3/16" Integrid Track shall have pre-punched 0.25 diameter (6mm) mounting holes on 12 inch (305mm) centers for cable suspension mounting. Universal spring steel Cross Tee Clips (14) shall be supplied with each 12 foot (3.7m) track section. These clips shall accommodate the suspension ceiling system cross tees on any centers for any size ceiling tile. 1 1/4" CKT 1 13/16" NEUTRAL 1 7/16" ELECTRICAL Integrid Track and components shall be UL and CUL listed, CE Certified, and comply with the National Electric Code standards for Lighting Track. One and two circuit Integrid Track shall be rated at 120/250 volt, 50/60 Hz, 2400 watts maxi - mum each circuit. Each 20 amp/120 volt circuit shall be comprised of flat copper busbars and have a separate neutral busbar for each circuit busbar. The neutral busbar shall be oversized to be comparable to #10 gauge 30 amp wire to reduce the possibility of overheating due to non-linear loads and harmonics. A separate grounding busbar shall be integral in all track lengths. All busbars shall be insulated to prevent contact with aluminum extrusion. 2 1/2" Two Ckt 120V Integrid Track 1 13/16" Integrid Track shall have electric feed capability through.75 diameter (19mm) 1/2-14NPS threaded hole in both cast alloy End Feed and cast alloy Straight Joiner/Feeder. 1/2" One and two circuit Integrid lighting track with separate neutral busbars shall have the ability to have each circuit separately dimmed as required when using standard voltage and low voltage fixtures with either magnetic or electronic transformers. Track shall have the ability to be dimmed or switched in selected sections in addi - tion to dimming or switching an entire track configuration or track run. GROUND 2 3/16" FIXTURE FITTING INTERFACE Integrid Track shall accept only GE fiber reinforced Lexan fixture fittings which positively lock into track and cannot be energized by integral switch until safety interlock handle is in the closed position. Safety interlock shall also prevent fixture fitting removal from track unless the switch is in the off position. Upon insertion of fixture fitting into track, grounding connection from fixture fitting to track shall be automatically completed before any electrical contact is made with busbars. When removing fixture fitting from track, the grounding connection shall automatically be disconnected last. The fixture fitting shall recess into the track, creating a minimal profile below the track. Fixture fittings for magnetic low voltage fixtures shall be furnished with fuse of the correct ampere rating for integral transformer protection, and shall not be fused as a branch circuit. 1 1/4" CKT 1 NEUTRAL 1 13/16" 2 1/2" CKT 2 NEUTRAL 2 7/16" 08/18 www.lightingservicesinc.com Integrid Track 1

INTEGRID TRACK (120V) CONFIGURATION Straight Run Configuration CEILING TILES CROSS TEE INTEGRID END CAP INTEGRID STRAIGHT JOINER/FEEDER INTEGRID STRAIGHT MINI-JOINER MAIN RUNNER INTEGRID END FEED (USED AS MAIN RUNNER) 08/18 www.lightingservicesinc.com Integrid Track 2

INTEGRID TRACK (120V) COMPONENTS Key Features / Applications UL and CUL listed, CE Certified, Dry Location IBEW union made at LSI plant in USA Combination LSI Track and main runner for mechanically supporting suspended ceiling systems of major ceiling manufacturers Specification grade heavy duty.070 (2mm) extruded aluminum track 12 foot (3.7m) field cuttable lengths One circuit 20 amp or two circuit 40 amp capacity/120/250 volt Copper busbars equivalent to #12 AWG wire used as circuit and ground track conductors Oversized copper busbars equivalent to #10 AWG wire used as neutral track conductors Separate copper grounding busbar used throughout track system White finish Cast alloy End Feed for power input Cast alloy Straight Joiner /Feeder for power input and mechanical joining of track lengths Straight Mini-Joiner for electrically and mechanically coupling track lengths Combination End Cap/Clip for electrically and mechanically ending the main runner which also aligns the track with the wall or ceiling system as needed Universal spring steel Cross-Tee Clip allows suspension ceiling cross-tees to be connected anywhere along the track length. Integrid Track Sections Integrid Track Sections are used in conjunction with an End Feed, End Cap, Straight Joiners and Straight Mini-Joiners. Integrid Track Section lengths are nominal 12 foot (3.7m) which are field cuttable. Integrid Track Sections have integral extruded fins for supporting ceiling tiles. 14 Cross Tee Clips included with each section of track. 12 ft White One Ckt 41330 Two Ckt 42330 11'-11 7/8" Integrid Bridge Track Integrid Bridge Track is a complete portable, field cuttable, surface UniTrack system that mechanically and electrically mounts to and spans parallel runs of Integrid Track. Integrid Bridge Track provides an additional range of striking angles for track lighting fixtures or for centering a fixture over a target located between parallel runs of Integrid Track up to 8 foot (2.4m) on center. 9 ft White One Ckt 31325 9'- 0" Integrid Security Worklight Track Integrid Security/Worklight Track is a separately fed one circuit Integrid Track Section, suitable for most LSI track fixtures, that integrates into any LSI Integrid Track run or configuration at any location. Consult fixture cutsheet. LSI fixtures (add suffix EF) mechanically lock into Integrid Security/Worklight Track by means of special hardware and do not have on/off switches. All One Ckt 18 18 18 Joiner End Feed End Cap Section Section Section White 41350 41351 41352 17 1/2" Integrid End Feed Integrid End Feed is a cast alloy End Feed with integral fin for supporting ceiling tile and aligning Integrid Track with wall or ceiling system. White One Ckt 41300 Two Ckt 42300 4 1/2" 08/18 www.lightingservicesinc.com Integrid Track 3

INTEGRID TRACK (120V) COMPONENTS Integrid End Cap Integrid End Cap is a combination End Cap/Clip and is used for mechanically ending any Integrid Track run, and for aligning the Integrid Track with wall or ceiling system. White One & Two Ckt 40303 1/8" Integrid Straight Joiner/Feeder Integrid Straight Joiner/Feeder is a cast alloy Straight Joiner for mechanically and electrically coupling any two lengths of Integrid Track. White One Ckt 41304 Two Ckt 42304 4 1/2" Integrid Straight Mini-Joiner Integrid Straight Mini-Joiner is used to mechanically and electrically couple any two lengths of track in a straight line. Add.125 (3mm) for Integrid Straight Mini-Joiner when calculating overall lengths of straight runs (overall lengths are not the same as when using Integrid Straight Joiner/Feeder). Not for use as feeder. White One Ckt 41311 Two Ckt 42311 1/8" Integrid Track U-Ground Outlet Integrid Track U-Ground Outlet provides a convenient switched and fused U-Ground receptacle for power and is rated 5A-125V. Non-UL listed. Silver One & Two Ckt 31160 Black One & Two Ckt 31260 White One & Two Ckt 31360 5" Display Hook Display Hook is used to mechanically hang an item from the Integrid Track without electrifying it. Do not exceed 20 lbs. at minimum spacing of two feet (609mm). Silver One & Two Ckt 30761 Weight Support Bar 4 7/8" Weight Support Bar provides a threaded nipple and nuts to mount an item to Integrid Track without electrifying it. Do not exceed 20 lbs. at minimum spacing of two feet (609mm). Nipple size 1/8-27 NPS (.406 diameter). Silver One & Two Ckt 30762 Track Closure Cover 3'- 4" 7'- 4" 11'- 4" Field cuttable Noryl Track Closure Covers are used to enclose the open face of the track, and simply snap into place. Nominal Length 4 Ft 8 Ft 12 Ft Silver 30165 30166 30167 Black 30265 30266 30267 White 30365 30366 30367 08/18 www.lightingservicesinc.com Integrid Track 4

INTEGRID TRACK (120V) INSTALLATION General Notes When installing or using this track system, basic safety precautions should always be followed, including the following: Read all instructions. Do not install this track in damp or wet locations. Do not install any part of the track system less than five feet from floor. Do not install any fixture assembly closer than six inches from any curtain or similar combustible material. Disconnect electrical power before adding to or changing the configuration of the track. Check with a qualified electrician. Do not attempt to energize anything other than lighting track fixtures on the track. To reduce the risk of fire and electric shock, do not attempt to connect power tools, extension cords, appliances and the like to the track. Install per NEC and local codes. Save these instructions. Assembling Insert End Feed, Joiner/Feeder or End Cap END CAP completely into Integrid Track Section and tighten the recessed Phillips head screw. Do not use excessive force when inserting components into Integrid Track Section. Tighten hex head nut and bolt to structurally couple component to Integrid Track Section. Flanges align Integrid Track to ceiling system structure. Mini-Joiner, complete with splice bars, is used for coupling two Integrid Track Sections when feeding is not necessary. HEX HEAD BOLT END FEED THREADED PLUG RECESSED PHILLIPS HEAD SCREW MINI-JOINER HEX HEAD SCREW HEX HEAD BOLT JOINER FEEDER PHILLIPS HEAD SCREW 08/18 www.lightingservicesinc.com Integrid Track 5

INTEGRID TRACK (120V) INSTALLATION General Notes Mounting Hang Integrid Track System with suspension 1/4" MOUNTING HOLES ON 12" CENTERS SUSPENSION WIRE FLANGE wire (by others) from pre-punched 1/4 inch (6mm) mounting holes every 24 inches (610mm). Each wire must be capable of withstanding a 50 lb. pull. Be sure to mount Integrid Track in com pliance with NEC Lighting Track Article #410-101 (Installation) and #410-104 (Fastening) and any other applicable codes. LSI recommends a minimum of two mounting points per section of track. LSI track can be mounted on centers up to 6-0. Field Cutting CUT FLUSH LSI track can be easily field cut using a sharp hacksaw or a chop saw with a blade for nonferrous metals, such as Oldham commercial carbide series metal blade. Together, cut the aluminum track, Noryl insulation and copper with one straight cut. All pieces must be exactly the same length. Be sure to remove any burrs on the aluminum or the copper as this may affect the electrical and mechanical interconnection of components to track. Do not cut track to less than one foot in length. Ceiling Integration Prepare cross tee by flush cutting the end of the cross tee that will be attached to the Integrid Track. Cut the cross tee approximately 5/8 inch (16mm) from the end. Insert tab of the Cross Tee Clip into side slot of the main runner of the Integrid Track and rotate 90. Clip can accept the flush cut ceiling cross tee and can be located to accommodate any spacing of FLUSH CUT CROSS TEE CROSS TEE CLIP HOLE IN CROSS TEE CLIP TAB SIDE SLOT ceiling cross tees. Insert ceiling cross tee into Cross Tee Clip so that it sits firmly in the clip and rests on the Integrid Track flange. Install #6 self tapping screw (by others) through Cross Tee Clip using the clip hole as a guide. Each connection must be capable of withstanding a 180 lb. pull. Mount ceiling cross tees in compliance with Uniform Building Code Section 25.211.2 (Grid Members, Connectors and Expansion Devices). 08/18 www.lightingservicesinc.com Integrid Track 6

INTEGRID TRACK (120V) INSTALLATION Electrical Remove threaded plug from the top of die cast junction box. Remove the cover from the End Feed or the Joiner/Feeder, bring conductors through.75 diameter (19mm) 1/2-14 NPS threaded hole, and attach wires to identified terminals. Joiner/Feeders can be electrically field modified after removal of aluminum cover by rerouting internal pre-wired jumpers. DIE CAST JUNCTION BOX NEUTRAL 1 (SILVER) CKT 1 (BRASS) TRACK GROUNDING TERMINAL (GREEN) NEUTRAL 2 (SILVER) CKT 2 (BRASS) ALUMINUM COVER Installing LSI Fixtures To insert a fixture fitting into the track, the switch must be in the off position, with the handle open. Insert the fixture fitting straight up into the track until it seats evenly, close handle completely, switch on. If using one circuit track, make sure that the brass contacts which protrude from the side of the fittings are inserted facing the copper busbars. If using two circuit track, inserting the fixture fitting in one direction will connect to circuit one. Removing and reversing the direction of the fixture fitting will connect to circuit two. 08/18 www.lightingservicesinc.com Integrid Track 7