CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Similar documents
CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

E-RATED/MEDIUM VOLTAGE FUSES

Medium voltage fuses Medium voltage fuses

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

Low-Peak 600V Class RK1

General Purpose US Fuses

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Gears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.

IEC Standard Back-Up Fuse-Links

3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

Special Purpose Fuses

Mica Element Support. Compacted Quartz Sand. Length B

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Medium Voltage Fuses

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

N0N A 250V One-Time Class H Fuse

FX Full-Range Current-Limiting Fuse

6,3* 1,6 No Printed circuitboard Brass, Nickel plated MR 5-6 Y Yes Yes 5x20 &6x32

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

North American Power Fuses

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

PT Medium voltage fuses for potential and small power transformers

Accessories. For product data sheets, visit

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

X-Limiter full-range current-limiting fuse

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

Medium Voltage Metal-Enclosed Switches

NH Solid Blades 690 VAC sizes 000 to 3

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Product Selection Guide

Section Contents. Page. Introduction... 72

Medium Voltage. Section Contents. Page. Introduction...100

Low voltage, branch circuit fuses

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

K-Limiter high ampere Companion II fuse

R-Rated medium voltage fuses for motor circuit protection

R-Rated medium voltage fuses for motor circuit protection

Limitor -G General Purpose Fuses

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

T CLASS T FUSE BLOCKS

High Speed Fuses. Section Contents Page

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Low Voltage, Branch Circuit Rated Fuses

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Industrial Control Transformers

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

A. Submit manufacturer's literature and technical data before starting work.

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

PROTECTION AND CONTROL

Semiconductor Fuses European Fuses

onlinecomponents.com

Medium Voltage Metal-Enclosed Switches

3.2. Current Limiting Fuses. Contents

Fuse/Var Technical Data

SWITCHGEAR DIVISION PRODUCT PROFILES

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

High voltage current limiting Fuse links type CEF

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

Bussmann. Circuit Protection Solutions

Product Catalog Medium Voltage Fuses. Circuit Protection

Protistor size 70 gr 690VAC (IEC)

NX indoor current-limiting fuses

Critical Power Switchboards. Selection and Application Guide

Ferrule fuses. High Speed Fuses

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

Medium voltage fuses - European Fuses

Each of these factors, as they apply to the selection of Types CLE and CLS current limiting fuses, is briefly outlined on the following pages.

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Molded Current-Limiting Fuse

PANELBOARDS C1/C2 SECTION 6

S&C Manual PME Pad-Mounted Gear

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Semiconductor (AC) fuses

Transcription:

SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as well as easy installation and replacement. They are UL listed as general purpose current-limiting fuses and are for use indoors (or outdoors in a weatherproof enclosure). The unique time-current characteristic of Ferraz Shawmut E-rated fuses allows them to be closely sized to transformer full load rated current, as recommended by IEEE guidelines, without being affected by normal magnetizing inrush current. CL- 14 fuses are typically sized at transformer rated current of 133%, thereby providing superior overall protection. Features/ Benefits UL Listed for compatibility with UL listed equipment Clip-Lock mounting for reliable high integrity connection into circuit Current limiting for superior equipment protection HIGHLIGHTS: E-Rated UL Listed 5.5kV Complies with ANSI C37.46 APPLICATIONS: Protection for 5.5kV or 15.5kV transformers or distribution systems Blown-fuse indicator gives positive identification of open fuse Non-venting for silent operation Metal Embossed Catalog Number and manufacturing date for lasting identification Ratings Approvals DEFINITIONS: E-rating E-rated fuses operate as follows: 100E or less - must melt in 300 seconds (5 mins.) at 200 to 240% of E (ampere) rating. Over 100E - must melt in 600 seconds (10 mins.) at 220 to 264% of E (ampere) rating. Example - A 100E fuse must melt in 300 seconds with an applied current of 200 to 240 amperes. General Purpose Current-Limiting Fuse A general purpose current-limiting power fuse is one that is capable of interrupting all currents from its rated interrupting rating down to the current that causes melting of the fusible element in one hour. E 22 A055C AC: 10E to 600E 5.5kV, 63kA I.R. Sym. A155C AC: 10E TO 300E 15.5kV, 50kA I.R. Sym Clip-Lock Clips for Fuses: 228-700-520 (One pair of clips) UL Listed to JEEG, Fuses Over 600 Volts UL File # E143362

E-RATED / MEDIUM VOLTAGE FUSES / A055C 5.5kV Clip-Lock Mounted Catalog Numbering System A 0 5 5 C 2 D 0 R 0-4 5 0 E Ampere Rating Revision/No. Special Features Diameter (D=3 ) No. of Barrels Style (C= Clip Lock Mount) Max. Voltage Rating (055=5.5kV) Amp-trap Fuse Indicator Flush with Surface in Untripped Position E Blown Fuse Indicator Figure A Figure B Figure C Catalog Numbers, Ratings, Dimensions, Series, 5.5kV DIMENSIONS Inches (mm) INTERRUPTING NEW CATALOG OLD CATALOG AMPERE NUMBER OF FIG. RATING NUMBER NUMBER RATING BARRELS A B C RMS SYM.* AMPERES 5.5kV Max. Clip-Lock Style 15.25 (387mm) Clip Centers 3 (76.2mm) Barrel Diameter A055C1D0R0-10E 225-007-937 10E A055C1D0R0-15E 225-007-938 15E A055C1D0R0-20E 225-007-939 20E A055C1D0R0-25E 225-007-940 25E A055C1D0R0-30E 225-007-941 30E 1 A 16.81 16.12 0.5 63,000 A055C1D0R0-40E 225-007-942 40E (427) (410) (13) A055C1D0R0-50E 225-007-943 50E Tripped A055C1D0R0-65E 225-007-944 65E Force A055C1D0R0-80E 225-007-945 80E 2 lbs. A055C1D0R0-100E 225-007-946 100E A055C1D0R0-125E 225-007-947 125E A055C1D0R0-150E 225-007-948 150E 5.5kV Max. Clip Lock Style 21.25 (540mm) Clip Centers 3 (76.2mm) Barrel Diameter A055C1D0R0-200E 225-007-949 200E A055C1D0R0-250E 225-007-950 250E A055C1D0R0-300E 225-007-951 300E 1 A 22.81 22.12 0.5 63,000 A055C1D0R0-400E 225-007-952 400E (580) (562) (13) Tripped A055C2D0R0-450E 225-007-953 450E Force A055C2D0R0-500E 225-007-954 500E 2 B 2 lbs. A055C2D0R0-600E 225-007-955 600E * RMS ASYM. AMPERES = RMS SYM. AMPERES x 1.6 E 23

E-RATED / MEDIUM VOLTAGE FUSES / A055C A055C1DORO 10E to 400E and A055C2DORO 450E to 600E Minimum Melting Time Current Data, 5.5kV Fuses Total Clearing Time Current Data, 5.5kV Fuses A055C1DORO 10E to 400E and A055C2DORO 450E to 600E E 24

E-RATED / MEDIUM VOLTAGE FUSES / A055C A055C1DORO 10E to 400E and A055C2DORO 450E to 600E Peak Let-Thru Current Data, 5.5kV Fuses Maximum Instantaneous Peak Let-Thru Amperes E Available Current in RMS Symmetrical Amperes E 25

E-RATED / MEDIUM VOLTAGE FUSES / A155C 15.5kV Clip-Lock Mounted Catalog Numbering System A 1 5 5 C 1 D 0 R 0-8 0 E Ampere Rating Revision/No. Special Features Diameter (D=3 ) No. of Barrels Style (C= Clip Lock Mount) Max. Voltage Rating (155=15.5kV) Amp-trap Fuse Indicator Flush with Surface in Untripped Position Blown Fuse Indicator Figure A Figure B Figure C Catalog Numbers, Ratings, Dimensions, Series, 15.5kV DIMENSIONS Inches (mm) INTERRUPTING NEW CATALOG OLD CATALOG AMPERE NUMBER OF FIG. RATING NUMBER NUMBER RATING BARRELS A B C RMS SYM.* AMPERES 15.5kV Max. Clip-Lock Style 18.25" (464mm) Clip Centers 3" (76.2mm) Barrel Diameter A155C1D0R0-10E 225-007-967 10E A155C1D0R0-15E 225-007-968 15E 19.81 19.12 0.5 A155C1D0R0-20E 225-007-969 20E (504) (486) (13) A155C1D0R0-25E 225-007-970 25E 1 A Tripped 50,000 A155C1D0R0-30E 225-007-971 30E Force A155C1D0R0-40E 225-007-972 40E 2 lbs. A155C1D0R0-50E 225-007-973 50E 15.5kV Max. Clip-Lock Style 21.25 (540mm) Clip Centers 3 (76.2mm) Barrel Diameter A155C1D0R0-65E 225-007-974 65E A155C1D0R0-80E 225-007-975 80E 1 A 22.81 22.12 0.5 A155C1D0R0-100E 225-007-976 100E (580) (562) (13) A155C2D0R0-125E 225-007-977 125E 2 B Tripped 50,000 Force A155C3D0R0-150E 225-007-978 150E 2 lbs A155C3D0R0-200E 225-007-979 200E. A155C3D0R0-250E 225-007-980 250E 3 C A155C3D0R0-300E 225-007-981 300E * RMS ASYM. AMPERES = RMS SYM. AMPERES x 1.6 E 26

E-RATED / MEDIUM VOLTAGE FUSES / A155C A155C1DORO 10E to 100E / A155C2DORO 125E / A155C3DORO 150E to 300E Total Clearing Time Current Data, 15.5kV Fuses E Minimum Melting Time Current Data, 15.5kV Fuses A155C1DORO 10E to 100E / A155C2DORO 125E / A155C3DORO 150E to 300E E 27

E-RATED / MEDIUM VOLTAGE FUSES / A155C A155C1DORO 10E to 100E A155C2DORO 125E A155C3DORO 150E to 300E Peak Let-Thru Current Data, 15.5kV Fuses Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes E 28