HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

Similar documents
Zinc Oxide Surge Arrester EXLIM R

Zinc-Oxide Surge Arrester TEXLIM Q-C

Zinc Oxide Surge Arrester PEXLIM Q

GENERAL. CONSTRUCTION External

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Surge arrester POLIM-H..SD

MEDIUM VOLTAGE NETWORKS

3EK7 Medium Voltage Silicone Insulated Surge Arresters

Surge arrester POLIM-H.. ND

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

Surge arrester POLIM-C.. HD

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

3EK7 Distribution Class Surge Arresters. Answers for energy.

Directly Molded Polymer Surge Arresters

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge arresters Product overview

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5

Surge arrester POLIM-H..N

3EK7 Distribution Class Surge Arresters. Answers for energy.

Energy Division. PCA Single Column Polymeric Surge Arrester

High Voltage Surge Arresters Buyer s Guide Section PEXLIM P-Y

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

GE TRANQUELL Surge Arresters

High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK

EE 741 Over-voltage and Overcurrent. Spring 2014

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

Voltage limiting device HVL

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

High Voltage Surge Arresters Station Class

VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)

Voltage limiting device HVL

Surge Arrester 3EL2 superior protection up to 550 kv

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

High Voltage Surge Arresters Buyer s Guide Section Line Surge Arrester PEXLINK

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

132/11 kv, 25 MVA MOBILE SUBSTATION

3EQ Composite Housed Surge Arresters

Bowthorpe EMP LV/MV Outdoor Surge Arresters

Surge Arresters. Supply Program. Answers for energy.

Minnesota Power Systems Conference Insulation Coordination Tutorial November 6, 2014

UltraSIL polymer-housed VariSTAR station-class surge arresters

power cable accessories

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

Technical Specification

Station Class Polymeric Surge Arresters

Protection and Disconnection Equipment for High and Medium Voltage and Transformers Line

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

ENERGY /// TRANSMISSION LINE SURGE ARRESTERS IEC. Bowthorpe EMP Transmission Line Surge Arresters (IEC)

Independent Testing Laboratory for High Voltage Equipment

PRODUCT CATALOGUE. Overhead System

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Polymer Insulator. ITEM 15kV 25kV 35kV 69kV. Section length(l) 330±15mm 445mm 539mm 888mm. Min. arcing distance 215mm 300mm 340mm 701

POLYMER INSULATOR. Index

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Changing of the guard Polymer replaces porcelain for surge arresters

PORCELAIN INSULATORS

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

3EP6 porcelain surge arrester

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

ANSI DESIGN TEST REPORT Report No. EU 1512-HR-00.5 Type PDV 100 Optima Heavy Duty Distribution Class Surge Arrester

Overview Overvoltage protection

Transformer bushings, type GOH. Technical guide

GROUP D. Switch & Protective device.

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Technical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks

GE TRANQUELLTM Surge Arresters

Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks

surge arresters overvoltage limiters Low voltage limiters catalogue 2017

OHIO BRASS AIKEN, SC, USA

Compact Gas Insulated Switchgear (GIS) up to 145kV 126kV,145kV Compact Gas Insulated Switchgear (GIS)

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Silicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

Transmission Porcelain Surge Arresters

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

REPORT OF TEST ON Elastimold Molded Vacuum Reclosers (MVRs)

43-SDMS-01 SPECIFICATIONS FOR

High Voltage Surge Arresters Buyer s Guide

Modular Substation Technical Data. Modular Substation. Technical Data TGOOD

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

Overview about research project Energy handling capability

Vacuum Circuit Breaker VS1

Outdoor vacuum breaker for railway applications - FSK II

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Surge Arresters. UltraSIL Housed VariSTAR Surge Arresters 5 ka and 10 ka Class 1 IEC for MV Systems to 36 kv FEATURES.

Transcription:

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION Applications: (Polymer housed MOA for 110kv) (The polymer housed MOA for 10kv) (Porcelain housed MOA for 220kv) (35kv MOA without gaps for middle phase) (110kv MOA without gaps for suspension tower) (110kv MOA with gap for dead-end tower) 1 / 15

Pictures: (0.22KV-10KV Surge Arrester with Polymer housing) 6KV-10KV Surge Arrester with porcelain housing 6-36KV Surge Arrester with polymer housing, disconnector and bracket 2 / 15

(Base mounting Type, 35KV) (Base mounting Type, 110KV) (110KV-220KV) Transmission line MOA for 10~220Kv 3 / 15

Surge Arrester Core 4 / 15

General Description Metal oxide surge arrester of rated voltage 3.8-750kV are protective apparatus used for protecting AC transmission and transformation equipment against damage from atmospheric overvoltage and switching overvoltage. The products are manufactured according to manufacturing technology transferred from HITACHI Ltd. of Japan. Compared with silicon carbide surge arrester, metal oxide surge arrester has superior protective characteristics, good reliability, high discharge capacity, and simple construction etc. thus, assuring the best overall protection for transmission and transformation equipment. Usually, the arrester is connected between system and ground in parallel with protected equipment. At continuous operating voltage, zinc oxide resistors appear to be an extremely high resistance, the resistive current through the arrester is of the order of microamperes. In appearance of a lightning stroke or switching surge on the system, the residual voltage across the terminals of the surge arrester will be limited to a certain permissible value because of the excellent non-linearity of resistors, and high surge energy of the line will be absorbed, thus the insulation of electrical equipment is protected. The zinc oxide surge arrester can be used in the following conditions: ambient temperature -40 to +40 ; altitude above sea level up to 1000m; withstanding 8º earthquake intensity (horizontal acceleration 0.2g). Anti-vibration type, anti-pollution type and plateau type arrester are available for special application. Anti-vibration type arresters are adaptable for using in an area with 9º earthquake intensity (horizontal acceleration 0.4g); anti-pollution type arresters for light or heavy polluted condition; and plateau type arresters for relative high altitude area. Performance The zinc oxide surge arrester show an excellent protective performance, high capability to withstand lightning and switching surge, good response characteristics to steep lightning impulse and superior anti-pollution property. The performance of the arresters meets the requirement of IEC 60099-4(2000), IEEEC62.11 and JEC (Japan standard),and other standards are available. 5 / 15

Superior protective characteristics Electronic Alliance Owing to the high non-linearity and excellent steep response characteristics of zinc oxide resistors, both the steep wave front residual voltage and switching residual voltage of the zinc oxide surge arrester have been reduced. Thus the corresponding protective margins have been increased, and the protective margins for steep wave front surge, standard lightning and switching surge are approximately the same. Therefore, the best overall protection for electrical apparatus is provided. The zinc oxide arresters are especially suitable for application to low surge impedance system, such as multiple lines, capacitor banks or cable, where conventional SiC arresters can hardly be applied satisfactorily. Perfect overvoltage energy absorption capability The non-linearity coefficient of zinc oxide resistors is about 30-50. In fact no following current can be observed during lightning surge operating duty test. Hence the energy absorbed by the arrester is very small. Capability against multiple lightning is greatly improved. High overvoltage energy absorption capability The zinc oxide arresters can absorb all kinds of energy of lightning and switching surge. The overvoltage energy absorption capability of our zinc oxide surge arrester is as follows: Nominal system voltage (kv) 110-220 330 500 Discharge capacity 2ms, rectangular wave (A) 800 1000 1500 Long duration discharge class (IEC standard) Class2 Class3 Class5 Energy absorption capability (kj/kv) 3 5 8 Energy absorption capability limit (kj/kv) 9.2 11.2 15 Both nominal current operating duty test for 20 times and combined operating duty stability test have been passed successfully according to standard IEC. 6 / 15

High temporary overvoltage withstanding capability Temporary power frequency overvoltage may be caused by single line-to-ground faults, capacitive charging effects for long transmission line and load rejection effect, etc. After an initial energy of 3kJ/kV rating, 5kJ/kV rating and 8kJ/kV rating has been respectively injected into the arresters of 110-220kV, 330kV and 500kV, the zinc oxide surge arresters still possess capability to withstand a temporary power frequency overvoltage 1.1U R 10s, 1.15U R 2.5s, as shown in Figure 1. Reliable long term operating stability Since the zinc oxide surge arresters have no gaps, the zinc oxide resistors are exposed to a longterm load of normal operating voltage and all kinds of overvoltage. Therefore operating stability is of critical importance for zinc oxide arresters. Zinc oxide resistors of different size have passed accelerated aging test under 115 for 1000 hours according to IEC standard. A service life of more than 100 years may be expected at an ambient temperature of 40. Excellent anti-pollution performance Because the zinc oxide arresters have no series gaps, the influence of contaminants on porcelain surface upon the performance of arresters is greatly reduced, eliminating all the problems caused by series gaps, such as the reduction of spark-over voltage and degradation of the performance of interrupting following current. 7 / 15

About Disconnector The polymer housed MOA with disconnector for 3-10kV The polymer housed MOA with disconnector for 3-10kV is equipped with the insulation base and bracked. The top bolt of disconnector is directly connected with the bottom of MOA. The below bolt is connected with ground lead.fig7 shows the product's full assemblage. The disconnector shall operate at the power frequency short circuit while MOA's failure under the abnormal conditions. As the dotted line showed in Fig2,the grounding end of the disconnector breaks away automatically, and the failed MOA is separated from the system, that means the MOA needs to be replaced. To do so, the disconnector should has the rapidly operation characteristic, withstand current impulse and operating duty without working. -------------------------The polymer housed MOA with disconnector for 3-10kV------------------------- 1:Time versus current operation characteristic of disconnector The disconnector must operate at the fault current. Disconnector operation test has been performanced on high power test centre of Electrical Power Research lnstitute, P.R.China for values of current 800A,200A,20A,5A according to IEC Standard.Result of test is given in the right table Current 800A 200A Sample NO. 1 2 3 4 5 6 7 8 9 10 Operation 0.0160.0120.0180.0120.0190.0260.0760.0180.0680.066 time(s) Current 20A 5A& Sample NO. 11 12 13 14 15 16 17 18 19 20 Operation time(s) 50 35 2 1.5 24 46 529 595 98 316 8 / 15

2:The disconnector's ability for the current impulse and operating duty without working The disconnector is in series with the MOA. The disconnector shall has no operating while MOA is under the normal conditions, to guarantee the MOA can show its fine functions. The disconnctor shall withstand the following item according to GB11032: (1):Long duration current impulse test without operating. (2):Operating duty test without operating. (3):Type test made by Power lndustry Ministry Electric Power Appearance Quality lnspection & Test Centre, shows the superior performance of withstanding 2ms 150A,and operating duty with 4/10 s 65kA. 3:The installation of MOA with disconnector The bellow shows the connection of polymer housed MOA with disconnector for 3-10kV.dotted line shows the situation of the grounding part's disconnection while the disconnector operation. Note :Distribution MOA, station MOA and MOA for capacitors is connected directly with disconnector by insulation base 9 / 15

DISCONNECTOR INSTALLATION 1. MOA 2. INSULATION BASE 3. DISCNNECTOR 4. 30CM SOFT GROUNDING 5. INSTALATION BRACKET 10 / 15

THE PARAMETERS OF SURGE ARRESTORS Type Parameters HY5W-9/25.5 HY5W-12/34 HY5W-15/42.5 HY5W-18/51 HY5W-24/68 1 Max. Continuous operating voltage, U MCOV, kvr.m.s. 7.2 9.6 12 14.4 19.2 2 Rated voltage, U R, kvr.m.s. 9 12 15 18 24 3 Rated discharge current, ka peak value 5 5 5 5 5 4 Min. D.C. reference voltage, U 1mA, kv 13 17.2 21.5 25.8 34.4 5 Max. residual voltage at steep impulse 1/10μs, kv 6 Max. residual voltage at lighting impulse 8/20μs, kv 7 Max. residual voltage at switching impulse 30/60 μs, kv 8 Withstand capability at current impulse 2ms, A 9 Withstand capability at current impulse 4/10μs, ka 10 Housing insulation level at lighting impulse, kv 11 Housing insulation level at power frequency in wet 1 min., kv 12 Mechanical strength, torsional/ cantilever (N.m / N) 29.3 39.1 48.9 58.7 78.2 25.5 34 42.5 14.4 19.2 / / / / / 75 75 75 75 75 65 65 65 65 65 60 75 75 105 125 23 30 30 40 50 35/250 35/250 35/250 35/250 35/250 13 Creepage distance, mm 227 291 351 419 540 14 Dimension Diameter of sheds, mm 88 88 88 88 88 Number of sheds, pcs 3 4 5 6 8 Height of arrestors, mm 205 235 265 295 355 Weight of arrestors, kg 0.87 1.06 1.25 1.43 1.80 11 / 15

TypeParameters 1 Max. Continuous operating voltage, Electronic Alliance THE PARAMETERS OF SURGE ARRESTORS U MCOV, kvr.m.s. HY10W-15/42.5 HY10W-24/68 HY10W-30/85 HY10W-33/93.5 HY10W-36/102 12 19.2 24 26.4 28.8 2 Rated voltage, U R, kvr.m.s. 15 24 30 33 36 3 Rated discharge current, ka peak value 10 10 10 10 10 4 Min. D.C. reference voltage, U 1mA, kv 21.5 34.4 43 47.3 51.6 5 Max. residual voltage at steep impulse 1/10μs, kv 6 Max. residual voltage at lighting impulse 8/20μs, kv 7 Max. residual voltage at switching impulse 30/60 μs, kv 8 Withstand capability at current impulse 2ms, A 9 Withstand capability at current impulse 4/10μs, ka 10 Housing insulation level at lighting impulse, kv 11 Housing insulation level at power frequency in wet 1 min., kv 12 Mechanical strength, torsional/ cantilever (N.m / N) 48.9 78.2 97.8 107.5 117.3 42.5 68 85 93.5 102 36 57.8 72.2 79.5 86.7 250~400 250~400 250~400 250~400 250~400 100 100 100 100 100 75 125 145 145 170 30 50 60 60 70 60/250 60/250 60/250 60/250 60/250 13 Creepage distance, mm 355 545 675 675 740 14 Dimension Diameter of sheds, mm 103 103 103 103 103 Number of sheds, pcs 5 8 10 10 11 Height of arrestors, mm 240 330 390 390 420 Weight of arrestors, kg 1.69 2.58 3.16 3.25 3.55 12 / 15

THE PARAMETERS OF SURGE ARRESTORS TypeParameters 1 Max. Continuous operating voltage, U MCOV, kvr.m.s. HY10W-42/119 HY10W-60/170 33.6 48 2 Rated voltage, U R, kvr.m.s. 42 60 3 Rated discharge current, ka peak value 10 10 4 Min. D.C. reference voltage, U 1mA, kv 60.2 86 5 Max. residual voltage at steep impulse 1/10μs, kv 6 Max. residual voltage at lighting impulse 8/20μs, kv 7 Max. residual voltage at switching impulse 30/60 μs, kv 8 Withstand capability at current impulse 2ms, A 9 Withstand capability at current impulse 4/10μs, ka 10 Housing insulation level at lighting impulse, kv 11 Housing insulation level at power frequency in wet 1 min., kv 12 Mechanical strength, torsional/ cantilever (N.m / N) 136.8 195.5 119 170 101.2 144.5 250~400 250~400 100 100 185 221 80 110 60/250 60/250 13 Creepage distance, mm 875 1250 14 Dimension Diameter of sheds, mm 103 103 Number of sheds, pcs 13 18 Height of arrestors, mm 480 630 Weight of arrestors, kg 4.12 5.66 13 / 15

THE PARAMETERS OF SURGE ARRESTORS Type Parameters 1 Max. Continuous operating voltage, U MCOV, kvr.m.s. HY10W-90/232 HY10W-72/201 HY10W-90/240 72.5 57 70 2 Rated voltage, U R, kvr.m.s. 90 72 90 3 Rated discharge current, ka peak value 10 10 10 4 Min. D.C. reference voltage, U 1mA, kv 5 Max. residual voltage at steep impulse 1/10μs, kv 6 Max. residual voltage at lighting impulse 8/20μs, kv 7 Max. residual voltage at switching impulse 30/60 μs, kv 8 Withstand capability at current impulse 2ms, A 9 Withstand capability at current impulse 4/10μs, ka 10 Housing insulation level at lighting impulse, kv 11 Housing insulation level at power frequency in wet 1 min., kv 130 103 132 271 231 276 232 201 240 190 173 207 600 600 600 100 100 100 450 310 450 185 132 185 12 Mechanical strengthcantilever,( N) 1412 780 1412 13 Creepage distance, mm 2055 1860 3100 14 Dimension Diameter of sheds, big/small, mm 146/126 146/126 210/170 Number of sheds, pcs 11/10 10/9 14/13 Height of arrestors, mm 1010 915 1370 Total weight, kg 20 19 42 14 / 15

THE PARAMETERS OF SURGE ARRESTORS Type Parameters 1 Max. Continuous operating voltage, U MCOV, kvr.m.s. HY10W-120/325 HY10W-138/375 Y10W-120/325 Porcelain 96 111 96 2 Rated voltage, U R, kvr.m.s. 120 138 120 3 Rated discharge current, ka peak value 10 10 10 4 Min. D.C. reference voltage, U 1mA, kv 5 Max. residual voltage at steep impulse 1/10μs, kv 6 Max. residual voltage at lighting impulse 8/20μs, kv 7 Max. residual voltage at switching impulse 30/60 μs, kv 8 Withstand capability at current impulse 2ms, A 9 Withstand capability at current impulse 4/10μs, ka 10 Housing insulation level at lighting impulse, kv 11 Housing insulation level at power frequency in wet 1 min., kv 175 202 175 356 450 356 325 375 325 267 335 267 600 600 600 100 100 100 450 520 450 185 210 185 12 Mechanical strengthcantilever,( N) 1412 1412 3120 13 Creepage distance, mm 3100 3540 3200 14 Dimension Diameter of sheds, big/small, mm 210/170 210/170 302/272 Number of sheds, pcs 14/13 16/15 12/11 Height of arrestors, mm 1370 1474 1734 Total weight, kg 42 47 182 15 / 15