Pathfinder. Emergency LED lighting system

Similar documents
1 Mackwell Company Profile. 2 Emergency Lighting XYLUX XYVEX TEMPUS. 3 Emergency Monitoring System N-Light Connect N-Light EC

All our Eterna Emergency Exit Signage comply with current Exit Signage Regulations using the Signs Directive format.

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

Central Battery Systems Loadstar AC/DC Systems

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Arla Foods, Aylesbury Litex LED IP65. 2 Industrial and Hazardous Area

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

Central Battery Systems

FORMULA. w w w. b e g h e l l i. c o m PROFESSIONAL EMERGENCY LUMINAIRE

Central Battery Systems

30-450kW. Now Available. Ultima Compact Chiller Range kW. > Ultima Compact Chiller Range. Free-Cooling models up to 450kW.

EMERGENCY LIGHTING SPACING TABLES

Emergency Lighting Products Limited

power made simple kva RANGE Performance I Durability I Serviceability

Existalite ZV 4-pole self-contained emergency lighting conversion module

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Est FlexiPower Mini UPS FPX Mini kVA

PIB5 PIB6 PIB7. Pg

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents

2

7 Lighting Technology

Lithium-ion battery systems for ABB UPS solutions Reliable, lightweight and compact UPS energy storage for critical applications

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

PSU EN54-4 Power Supplies

Beam lights & conversion kits

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

INSTALLATION INFORMATION

S4 WIRE ROPE HOISTS EXPERIENCE THE DIFFERENCE

BH500 BH100 BH400 BH200 BH300 BH600 BH900 BH1100 BH700 BH1000 BH800. Series. Series. Series. Series. Series. Series. Series. Series. Series.

Reliant luminaires. Edge-lit exit sign available in 3 Colours. 40% Energy saving. 4 Years maintenance free. Easy first-fix installation

Options. Lamp and Control Gear Options. Materials. Specification. Photometric Data Cat. No. RXS1L-1CWZ. Installation Notes.

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

smartest light Sicherheitstechnik GmbH

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

Emergency lighting units EM LED Light Engines

6 Linergy LED+ Industrial IP20 CONTROLS

DIESEL Engine Fire Pump Controllers Features

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

MLD-44S/g V AC/50-60Hz. MLD-28S/g. MLD-34S/g

SAVE THESE INSTRUCTIONS

Electronic Fluorescent Ballasts

LED Emergency Lighting Core Range. Core LED emergency lighting range Small text. Low energy LED solutions for compliant emergency lighting

5 Linergy LED. Industrial. Mains lighting IP20

Outdoor emergency lighting

5 Linergy LED. Industrial. Mains lighting IP20

premium charge Innovative charging technology Made in Germany

trak power premium charge

RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION

Compact Sheet-Steel Light Fittings Series 6114

Enphase - The smartest choice in solar energy.

Self Contained Emergency Lighting

Going the Distance - Solving Power Reach Issues With Diverse DAS Solutions

Treatment Chamber. Control System. ETS Manual Updated 10/24/05

Uninterruptible Power System

Segen offer the SE2200, SE3000, SE3500, SE3680, SE4000, SE5000 and SE6000 single-phase inverters at great value prices.

SentryGOLD Fully-Automated Fuel Management System

Whitecroft Lighting. Outdoor Lighting

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Silent Gliss. Roller Blind Systems

Free Fall Fire Valve Range & Accessories

@SOLAXEUROPE /SOLAXEUROPE /SOLAXPOWER

» Eco-Friendly. » Intelligent» Space Saving

OPERATING INSTRUCTIONS MCP-MT1

Junction Boxes. & Accessories. A first class range of essential wiring accessories required for any installation

Uninterruptible Power System

airbox User Manual VARIFLOW/VARIFLOW 8 telephone: +44(0) web:

Gate & Door Controller with LCD and Intelligent Technology

EPAS Desktop Pro Software User Manual

Well dimensions are absolute min. plumbed dimensions. Shaft floor to be constructed in accordance to layout drawing

Beghelli PRÄZISA. SicuroLED. Decentral Power System

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Rapier AX Air Break Switch Disconnector. engineering brilliant solutions

» Sophisticated» Reliable» Intelligent

AcuLok TMO. Transformer Mounted Distribution Cabinets

Two lights are better than one. LUMILUX DUO

SNMP dedicated to ORVALDI Solar Infini

TRI acdc1030. A compact, shallow, fixed, triple, LED recessed, downlight luminaire delivering 200lm. IP20

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

Norwich Hostry Norwich, UK. Downlight Lighting

CALL FOR A QUOTE (877)

DATUM ELECTRONICS RS425 NON-CONTACT TORQUE TRANSDUCER PRODUCT OVERVIEW

RXD. 194 Downlights & Spotlights

CONTACT YOUR AUTHORISED STOCKIST

This section covers the comprehensive range of Torque Calibration equipment manufactured by Gedore Torque.

User s Manual CC-MPPT-HV-50

User friendly charging technology. Smart chargers Fiamm Motive Power Premium HF flex Premium HF com

DC TECHNOLOGY OVERVIEW

DPA UPScale RI kw The modular UPS for customized solutions

Industrial Linergy LED

Adam Equipment CPW COMPACT SCALE

PULSE-8: MASTER PULSATION CONTROL

Rotary Screw Compressor Packages

Uninterruptible Power System

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

EMEX Power. EMEX Power. Modular AC/AC Central Battery System. EMEX Power

Transcription:

Pathfinder Emergency LED lighting system

Pathfinder Pathfinder is a self contained central battery LED emergency lighting system designed to create an optimum emergency lighting scheme. Driving Down Energy Consumption LEDs have many advantages over traditional emergency lighting systems. Low energy comsumption and 50,000 hour life means that Pathfinder will dramatically reduce your through life maintenance and running costs, whilst it is not generally recognised that integral emergency luminaires can add significantly to the overall energy comsumption of a lighting installation. The constant trickle charge required to maintain emergency batteries can account for up to 14% of the luminaires overall energy comsumption. This parasitic load can be reduced dramatically by using Pathfinder, as the extremely low energy comsumption requires only a fraction of the power to charge. Energy Consumption 10W 5W 0W Self Contained Fluorescent luminaire Pathfinder Energy consumption of an emergency luminaire Lowest Cost of Ownership Self contained emergency lighting with an individual battery pack and inverter in each luminaire can offer the lowest installed cost for an emergency lighting scheme, however there are two issues which can make the solution very expensive over the full life cycle of an installation: Manual testing via key switches is labour intensive and can be unreliable A four year battery life requires frequent maintenance and replacement Central testing systems can dramatically reduce the cost of emergency testing compared to manual testing, however maintenance and replacement of self contained batteries is still expensive. Conventional central battery central test systems can significantly reduce the cost of battery maintenance and replacement due to ease of access. Pathfinder LED central battery central test offers the lowest energy and life cycle cost solution. Low energy consumption means battery life capacity is only 5% of that for a conventional central battery system. Thousands 300 250 200 150 100 50 0 181 59 17 self contained manual test Cost to administer emergency testing Through life planned maintenance costs including replacement of batteries and electronics at the end of rated life. Initial installed cost includes luminaires, FP200 cable where required, central system components, batteries and installation labour 99 34 self contained central test central battery central test Pathfinder Full Life Cycle costs based upon 300 lighting points over a 25 year cycle 51 73 32 53 2

The pathfinder system Overview Pathfinder is a self contained, low power supply, central battery LED emergency lighting system. The system is capable of conducting automatic testing in accordance with BS EN 2034 and contains a non volatile memory able to store up to 2,000 test events. As Pathfinder is a dedicated emergency system it can be used to create an optimum emergency lighting scheme, that is simple and cost effective to install and is scalable to meet the changing needs of a building. With simple and efficient testing regimes, utilising long life, low maintenance LEDs combined with cost effective installation, Pathfinder will deliver the lowest cost of ownership of any emergency system on the market today. LED Heads Delivering all the benefits of LEDs, the Pathfinder LED Head integrates effortlessly with its surroundings and due to its efficient, effective performance and with the ability to create an optimum emergency lighting scheme, initial installed costs are reduced. IP8 version also available The LED escape route head is especially effective in corridor applications. LED Stairwell For the architecturally demanding applications, the Pathfinder LED Stairwell provides a discreet emergency lighting solution. With a life span of 50,000 hours and robust construction, years of low through life maintenance costs are available. Control Panels PFDPANEL12AH PFDPANEL24AH PFDPANEL48AH With the system utilising low energy LEDs, batteries are incorporated in the control panel and require significantly less space than traditional fluorescent central battery systems. LED Exit Signs Utilising the latest LED technology, Pathfinder Exit Signs are robust and have a much longer life than traditional florescent exit signs. Due to their compact size, Pathfinder Exit Signs offer architectural integration as standard and are less intrusive than comparative fluorescent products. Order legend panels separately, all legend panels comply with the standard BS 52-1 (BS EN ISO 7010) 3 4

Pathfinder specification Overview Pathfinder is a self contained, low power supply, central battery LED emergency lighting system in accordance with BS EN 50171 Central Power Systems. General The Pathfinder self contained, low power supply, central battery LED emergency lighting system must be capable of conducting automatic testing in accordance with BS EN 2034 and contain a non volatile memory able to store up to 2,000 test events. The logbook must be able to be downloaded directly from the panel to a INO stick. With a cabinet size of 800 x 400 x 170 (mm) containing valued regulated lead acid batteries to provide 3 hours emergency duration backup power in the event of mains failure for a total load of 12 Amps. Load to be supplied via four separate circuits with each circuit to have both output terminals fused with serviceable fuse holders. The Pathfinder self contained, low power supply, central battery LED emergency lighting system must be capable of continuously supplying 24V volts from each output circuit whilst running in mains healthy mode. A single 2-core cable from each of the four circuits must be able to supply 24 volts to twenty emergency LED luminaires whilst simultaneously acting as the data control line for each emergency LED luminaire. Each emergency LED luminaire shall have a unique address with mode of operation being determined at the Pathfinder control panel to allow for non-maintained, maintained and switched maintained emergency luminaires on the same circuit. Whilst running in mains healthy mode each emergency LED luminaire shall be able to have a pre-set dimming level determined at the Pathfinder control panel. Dimming parameters must be from 0% to 100% with programmable incremental values of 10%. In the event of mains failure all the emergency LED luminaires shall operate at full output. The Pathfinder control panel must include four input switching circuits to control any switched maintained operation on the output circuits. For each luminaire a description / location must be programmable at the Pathfinder control panel. The programming features of the Pathfinder control panel must be password protected. The Pathfinder control panel display The Pathfinder control panel display must continuously display the system status via a 4 x 20 LCD display and four panel mounted indicator LEDs showing system healthy, battery operation, (general) failure and charge failure. Each output circuit must have two panel mounted indicator LEDs capable of showing circuit on and circuit fail status. Networking Each Pathfinder control panel must be capable of being accessed via an internet browser over a network by way of IP addressing. The Pathfinder control panel should be controllable via an internet browser to allow for remote functional testing, blocking / releasing of the devise and manual reset. The Pathfinder control panel must also allow the system status to be viewed, stored and printed via a web browser. Software Software loaded onto a central PC must be cable of interrogating and controlling networked Pathfinder control panel units and be able to configure all automatic testing and display, store and print all test results. The software must also be capable of automatically sending status reports via email. Loading Chart for Pathfinder LED Units Description Part Number Loading (A) Large Exit Sign 22M (ceiling, wire or rod suspended) PFD CEILING / WALL / SUSPENDED //22M Requires Legend 0.125 LED Exit Sign Recessed Ceiling Mounted PFDRECESSED 0.150 Architectural Exit Sign PFDARCH / CEILING / WALL / SUSPENDED Requires Legend 0.200 LED Exit Bulkhead IP43 PFDEXIT/IP43 Requires Legend or Cover 0.125 LED Exit Bulkhead IP5 PFDEXIT/IP5 Requires Legend or Cover 0.200 Recessed LED including Corridor & IP8 PFDRELED S/W - PFDCOLED S/W - PFDRELEDS/IP8 0.140 Stairwell LED Light PFDSTAIR 0.115 Maximum Cable Runs The maximum lengths of a cable run (for the maximum allowable voltage drop of 3.5V and maximum length for control) are as follows: Note: Output circuit power Radial Cable size Length of cable run Output circuit power Ring Cable size Length of cable run 1.5mm 2 49m 1.5mm 2 98m 2A MAX 74m 2A MAX 148m 1A 147m 147m 1A 294m 294m 2.5mm 2 82m 2.5mm 2 14m 2A MAX 123m 2A MAX 24m 1A 245m 245m 1A 490m 490m The tables above are typical indicative examples only, final design will need to take into account: Number of units Types of units Length of control wiring per channel Location of Panels 5

UK Head Office Whitecroft Lighting Ltd Burlington Street Ashton-Under-Lyne Lancashire OL7 0AX T +44 (0)11 330 811 F +44 (0)11 331 5855 email@whitecroftlight.com London Customer Centre Whitecroft Lighting Ltd 102-108 Clerkenwell Road London EC1M 5SA T +44 (0)11 330 811 F +44 (0)11 331 5855 Rep. Ireland Office Ireland Office Fagerhult Ltd F1 Calmount Park Ballymount, Dublin 12 Ireland T +353 (0)1 42 0200 F +353 (0)1 429 90 info@fagerhult.ie www.fagerhult.ie Middle East Office Fagerhult Middle East P.O. Box 12287 Dubai United Arab Emirates T +971 (0)4 3297120 F +971 (0)4 3297130 info@fagerhult.ae www.fagerhult.ae whitecroftlighting.com