Phase-Adaptive Power Module with 3-Wire Fluorescent Input

Similar documents
3-Wire Fluorescent Power Module

Phase-Adaptive Power Module

Switching Power Module

Phase-Adaptive Power Module

LP Dimming Panels. GRAFIK Systems

GRX-TVI Ten Volt Interface

GRX-TVI Ten Volt Interface

GRX-TVI Ten Volt Interface

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module

Maestro Wireless Dimmers and Switches

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

Wired Vareo Local Lighting Controls

Wired Maestro Local Controls

DIN Power Module - Phase Adaptive

GP Dimming Panels 230 Volt (CE)

DIN Rail Power Module

LCP128T Spec Grade Dimming System

Maestro Wireless Dimmers and Switches

GP Dimming Panels 230 Volt (CE)

HomeWorksR QS Wired MaestroR Architectural Local Controls

Vive Maestro Wireless Dimmers and Switches

Controls. CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES

Adaptive Power Module

Maestro Wireless Dimmers

Installation Instructions Please Read Before Installing. Overview. Important Notes. Designer-Style Maestro Remotes HD-RD, -RS 120/127 V ~, 50/60 Hz

HomeWorks QS RF C L Hybrid seetouch Keypads

Adaptive Power Module

Model Number Description Voltage Load Type Minimum Load Maximum Load. Incandescent / Halogen. General Purpose Fan

RadioRA 2 Maestro Local Controls

HomeWorks QS Designer RF Maestro Local Controls

Maestro Wireless Dimmers and Switches

Maestro C.L multi-location dimmer 150W CFL/LED or 600W. Inc/Hal 120V In White Vive Enabled

SAVE THESE INSTRUCTIONS

RadioRA 2 Maestro Local Controls

SAVE THESE INSTRUCTIONS

EcoSystemT 5-Series LED Driver ( V~, CE)

Fluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase.

Maestro Wireless Local Controls

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

EcoSystemR Multiple Control Input Ballasts

Residential Systems Control of LED Lighting (120V)

Lumea C L Dimmer. Wallbox Controls

Skylark C L Dimmer. Skylark. C L Dimmer. Wallbox Controls

Installation Instructions

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

Ariadni 250 W C L Dimmer

HomeWorks QS Power Supply with Wire Harnesses

ALD Dimmer Enclosures

Skylark Contour C L Dimmer

RADIORA2 C.L Multi-Location Dimmer 150W CFL/Led or 600W Inc/Hal 120V In White. 6 to 277 VAC lights/3 VAC fan/3 VAC light and fan

INCANDESCENT/HALOGEN/MAGNETIC LOW VOLTAGE

EcoSystem Multiple Control Input Ballasts

Primary controls RadioRA 2 designer dimmers and switches

Diva 250 W C L Dimmer

Installation & User Instructions

Skylark C L Dimmer. Skylark. Wallbox Controls. Dimmer for CFL and LED dimmable bulbs.

Skylark C L Dimmer. Skylark. C L Dimmer. Wallbox Controls

Skylark Contour C L Dimmer

4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! Description. System Specifications. Installation Instructions Occupant Copy

EcoSystem Multiple Control Input Ballasts

RTA-RX-F-SC and RTA-RX-F-SC-347

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

GVR GROUPS. Control4 Outlet Dimmer and Switch. Control4 Wireless Outlet Dimmer LOZ-5D1 Control4 Wireless Outlet Switch LOZ-5SI

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371

Diva C L Dimmer. Wallbox Controls. Dimmer for CFL, LED, Halogen, and Incandescent dimmable bulbs.

Diva Dimmer - Gloss Finish, Fluorescent or LED Dimming with. Poles 1 Voltage Rating 277 0% to 90% humidity, non-condensing. Indoor use only.

OUTDOOR TRACK. LABELS Assembled in America

TOUCH THE FUTURE OF LIGHTING CONTROL

Touch the future of lighting control

Wiring Diagram Index. Find product, model #, and wiring diagram # Then find wiring diagrams on pgs

DRDHNJ Recessed LED Downlight General New Construction Junction Box

AYCL153PHWH 1P/3W CFL/Led Dimmer White

L4B-F-RF Round Fixed Frame In BRO

Elegance Electrician s Installation Guide

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Compact SE Overview. High-Performance Dimming. Ballast

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube

Diva 250 W C L Dimmer

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Dimmer, reverse-phase, 3-way/single-pole

Installation Instructions

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells

AYCL153PHWH 1P/3W CFL/Led Dimmer White. Ariadni CÂ L Dimmer, CFL/LED (Screw-based),

DRD2 Recessed LED Downlight General New Construction Junction Box PRODUCT SPECIFICATIONS

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming

Diva Dimmer - Gloss Finish, Fluorescent or LED Dimming with

INSTALLATION. **Microprocessor Status LED:

ECO-T LED RECESSED TROFFER USER MANUAL

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

Hi-lume Premier 0.1% EcoSystemTM / 3-wire Constant Voltage 24 V- LED Driver with Soft-on, Fade-to-BlackTM

High Bay Luminaire Series

Ceana dimmers. Traditional wallplate opening in (73 mm)

DRD2X & OneFrame Concrete Apex Series Recessed LED Downlight

Aperture. Color Quality. 90+ CRI, 2-step SDCM. 2700K 3000K 3500K 4000K Spot (20 ) Narrow Flood (30 ) Flood (40 ) 4000cd (Spot 750 lm) Dimming

DRD2 Recessed LED Downlight General Remodel 4", 5", 6" Aperture

Quick Start Guide TS 910 & TS 920

SAVE THESE INSTRUCTIONS

OneFrame & DRD2 Recessed LED Downlight General New Construction DRDHNJD Deep Junction Box

Transcription:

369-358c 1 03.19.12 Description When connected to a 20 A circuit breaker, provides capacity on a 3-wire fluorescent dimmer for a full 16 A load of lighting. May be used to dim incandescent, halogen, electronic low-voltage (ELV), magnetic low-voltage (MLV), neon/cold cathode, or LutronR Tu-WireR lighting sources. Phase-adaptive technology automatically selects leading-edge or trailing-edge dimming for lowvoltage transformers. Up to 3 power modules may be controlled by a single dimmer. Models require control voltage. Models available for only or 120 277 V~ load voltage. ot for use with non-dim loads. Works with versions of: LutronR 3-wire fluorescent dimmers (consult Lutron for ViertiR); see approved list in the dimmers & switches specification guide at www.lutron.com GRAFIK EyeR QS control units* GRAFIK EyeR 3000 Series control units** LP, LCP, and GP dimming panels** HomeWorksR and HomeWorksR QS remote power panels** EcoSystemR interface C5-BMJ-xxx *Set to fluorescent module load type **Set to 3-wire fluorescent load type Model and Capacities Control Voltage Voltage Capacity Model umber Only 120-277 V~ 16 A PHPM-WBX-DV-WH Only 16 A PHPM-WBX-120-WH Job ame: Model umbers: Job umber:

Specifications Power Control voltage: voltage: only for PHPM-WBX-120-WH 120 277 V~ for PHPM-WBX-DV-WH Capacity: Full 16 A : 1920 W 120 277 V~: 1920 4432 W Frequency: 50 / 60 Hz, phase-to-neutral. (output) power: Phase independent of control device/control voltage. Sources/ Types Operates these sources with a smooth continuous Square Law dimming curve: Incandescent (tungsten) Halogen MLV transformer (iron core) ELV transformer (solid-state) (must be manufacturer approved for reverse-phase control dimming) eon/cold cathode LutronR Tu-WireR fluorescent dimming ballasts Incandescent and ELV sources may be controlled on the same circuit/control zone. Up to 30% of the unit s capacity may be used for incandescent lighting. Incandescent and MLV sources may be controlled on the same circuit/control zone. Up to 30% of the unit s capacity may be used for incandescent lighting. ELV and MLV sources may OT be controlled on the same circuit/control zone. PHPM-WBX not for use with non-dim loads. Use switching power module (PHPM-SW-DV-WH) for non-dim loads. Minimum load on power module is 10 W. Output must be directly connected to the load. side switching is not recommended. 369-358c 2 03.19.12 Key Design Features Automatically selects between forward phase/ leading edge (i.e., MLV) and reverse phase/ trailing edge (i.e., ELV) dimming/output based on connected load. Patented RTISST circuitry compensates in real time for incoming line voltage variations: Compensates for +/-2% change in RMS voltage/ cycle and +/-2% Hz change in frequency/second. Provides air-gap off. Module protects itself during most temporary overcurrent and over-voltage conditions. Two LEDs on front of unit provide diagnostic information (visible when faceplate is removed). Terminals Each terminal accepts up to two 12 AWG (2.5 mm 2 ) wires. Environment 32 to 104 F (0 to 40 C). Relative humidity less than 90% non-condensing. Indoor use only. Maximum heat output of module: 135 BTU. Mounting Surface or recess mount. Power module is UL tested and approved for use in spaces designed for environmental air handling. Job ame: Model umbers: Job umber:

Dimensions and Mounting Mount in 2-gang U.S. wallbox 3.5 in (89 mm) deep or 4 x 4 in (102 x 102 mm) junction box 2.1 in deep (53 mm). Indoors only. This device generates heat; mount only where ambient temperature is 32 to 104 F (0 to 40 C). Mount with arrows facing up to ensure adequate cooling. Allow 4.5 in (114 mm) above and below faceplates when mounting several modules in a vertical layout. Units may butt together when mounted in a horizontal layout. Mount so line (mains) voltage wiring is at least 6 ft (1.8 m) from sound or electronic equipment and wiring. Mount within 7 of true vertical. Mount to 2-gang U.S. wallbox Mount to 4 x 4 in (102 x 102 mm), 2.1 in (53 mm) deep U.S. junction box 369-358c 3 03.19.12 1.2 in (30.5 mm) 1.4 in (35.5 mm) Mount to 4 x 4 in (102 x 102 mm), 2.1 in (53 mm) deep U.S. junction box with barrier (for 277 V~ loads if required by local electrical code) 5.1 in (129.5 mm) 6.3 in (160 mm) Barrier Job ame: Model umbers: Job umber:

Wiring 369-358c 4 03.19.12 Pull 12 AWG (2.5 mm 2 ) copper (Cu) wires (75 C/167 F minimum) for input power and load circuit. Strip 1/2 in (12 mm) insulation from wires before connecting. Run separate neutral for load circuit - no common neutrals. May be used with GFI breaker protected loads. circuit wiring (from GFI breaker to power module to load) must be run in its own non-metallic conduit, or nuisance tripping may occur. Maximum 100 ft (30.5 m) between power module and load. May be used with AFI breaker protected loads. Maximum load on AFI circuit is 1000 W. Exceeding 1000 W may cause nuisance tripping of AFI breaker. Single Power Feed for Control and Sides ote: The power module may be on the same circuit/control zone as the control device only if the total load does not exceed the rating of the breaker. Circuit breaker 3-wire fluorescent dimmer SH (red wire) Cap off Control eutral (yellow or orange wire) Legend Hot/Live eutral SH Switched Hot Dimmed Hot Ground ot Used Job ame: Model umbers: Job umber:

Wiring 369-358c 5 03.19.12 Separate Power Feeds for Control and Sides The load breaker may be on a different phase than the control breaker. SH (red wire) Cap off 3-wire fluorescent dimmer } Control breaker (yellow or orange wire) breaker wiring (see ote below) Control eutral Legend Hot/Live eutral SH Switched Hot Dimmed Hot Ground ot Used ote: feed: for PHPM-WBX-120-WH; 120 277 V~ for PHPM-WBX-DV-WH Job ame: Model umbers: Job umber:

Wiring Multiple Power Modules to a Single Control Device 369-358c 6 03.19.12 Shown with separate feeds for control and loads. All breakers must be turned off prior to installing or servicing the modules. Up to 3 power modules may be wired to a single dimmer. wiring for Power Module #1 (see ote below) breaker SH (red wire) Cap off 3-wire fluorescent dimmer (yellow or orange wire) Control eutral } Control breaker wiring for Power Module #2 (see ote below) breaker Control eutral wiring for Power Module #3 (see ote below) breaker Control eutral ote: feed: for PHPM-WBX-120-WH; 120 277 V~ for PHPM-WBX-DV-WH Job ame: Model umbers: Job umber:

Multi-location Wiring 369-358c 7 03.19.12 ote: The power module may be on the same circuit/control zone as the control device only if the total load does not exceed the rating of the breaker ( only). Circuit breaker wiring (see ote below) Control eutral Legend Hot/Live eutral SH Switched Hot Dimmed Hot Ground ot Used (yellow or orange wire) 3-wire fluorescent dimmer (main dimmer) SH (red wire) Cap off 3-wire fluorescent dimmer (accessory/ companion dimmer or 3-way switch) For specific wire colors, see the wallbox lighting controls catalog at www.lutron.com/wallbox catalog ote: feed: for PHPM-WBX-120-WH; 120 277 V~ for PHPM-WBX-DV-WH Job ame: Model umbers: Job umber:

Wiring to a GRAFIK EyeR QS Control Unit 369-358c 8 03.19.12 Separate Power Feeds for Control and Sides The load breaker may be on a different phase than the control breaker. Set load type to fluorescent power module GRAFIK EyeR QS control unit 1 2 3 4 5 6 L } Wire to appropriate zone Control breaker breaker wiring (see ote below) Control eutral Legend Hot/Live eutral SH Switched Hot Dimmed Hot Ground ot Used ote: feed: for PHPM-WBX-120-WH; 120 277 V~ for PHPM-WBX-DV-WH Job ame: Model umbers: Job umber:

Wiring to an EcoSystemR C5-BMJ Interface 369-358c 9 03.19.12 Separate Power Feeds for Control and Sides Control side must be The load breaker may be on a different phase than the control breaker. ote: feed: for PHPM-WBX-120-WH; 120 277 V~ for PHPM-WBX-DV-WH Orange () White () Red (cap off) Green breaker wiring (see ote above) Control eutral C5-BMJ Only Black () Distribution Panel* ( only) Legend Hot/Live eutral SH Switched Hot Dimmed Hot Ground ot Used *ote: C5-BMJ must be powered from a distribution panel to ensure proper voltage to the Zone In terminal of the PHPM-WBX interface. Job ame: Model umbers: Job umber:

Wiring a Power Module to an LP, LCP, GP, or HomeWorksR Panel 369-358c 10 03.19.12 Up to three phase-adaptive power modules may be wired to an output of a LutronR dimming panel. The load type for the output must be set appropriately on the panel s circuit selector (for an LP or GP panel), controller (for an LCP panel), or HomeWorksR software (for a HomeWorksR panel). Wire to appropriate output wiring (see ote below) Zone In Control eutral (1) 14 to 10 AWG (2.0 to 4.0 mm 2 ) (1) 14 to 10 AWG (2.0 to 4.0 mm 2 ) Dimmed Hot eutral H ote: if used with PHPM-WBX-120-WH power module 120 277 V~ if used with PHPM-WBX-DV-WH power module Set load type to 3-wire fluorescent Branch circuit breakers eutral lug Power (Hot/Live) (3) 14 to 2/0 AWG (2.0 to 70 mm 2 ) eutral (1) 14 to 2/0 AWG (2.0 to 70 mm 2 ) Job ame: Model umbers: Job umber: