McQuay Central Station Air Handler Medium Pressure MSL

Similar documents
McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay Climate Control Singer

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

Complete HVAC Capability

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

FHP MANUFACTURING PARTS PRICE LIST

FHP MANUFACTURING PARTS PRICE LIST

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

McQuay Singer Climate Control. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage C. Last Manufactured: 1990

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

REPAIR PARTS. DAR090/120 Commercial Air Handlers DAR0904AA DAR1204AA. This manual is to be used by qualified technicians only.

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Crane Inspection Log. Mailing Address: P.O. Box Tulsa, OK Phone: (918) Fax: (918)

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin McQuay. Rooftop Heat Pump. WRWA, WRGA, WRWC, WRGC WRWD, WRGD, WRWH, WRGH Designs 1, 2. Replacement Parts List No New 03/2011

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

REPAIR PARTS. DAT Commercial 2-Speed Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-D4022.

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1)

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

REPLACEMENT PARTS MANUAL

SERVICE PARTS LIST FOR MITSUBISHI ELECTRIC PACKAGED AIR-CONDITIONERS

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

REPLACEMENT PARTS MANUAL

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1)

MODEL OF AIRCONDITIONER CCW PARTS LIST

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

REPLACEMENT PARTS MANUAL

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017

QUICKAIRE. Belt Drive Air Handling Units. P.O. Box 956 Paoli, PA (800) FAX (610)

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH301 WH361. Models: Contents. General Notes. Important. Description

REPLACEMENT PARTS MANUAL

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

McQuay Climate Control Singer. Water Source Heat Pump. VF, VG, VP Vintage C. Last Manufactured: 1982

Transcription:

Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revision History...3 Nomenclature Serial Number...4 Model Number...5 Coil Notes...6 Contractor Coil Code Strings...6 Blower Fan Section Daigram...7 Components...8 Air Handler; MSL Size 190 Vintage C Rev. B 09/16 RPL 552237 / Page 2

Parts List Revision History Revision Date Description 10/81 New. 07/83 New RPL. 12/90 New RPL. A 08/16 Rebrand Daikin. Change from PDF to Indd. Change p/ns- convert to nine digit system. Page 5- Add code index. B 09/16 Page 4- Add Serial number (Page Added). Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 Air Handler; MSL Size 190 Vintage C Rev. B 09/16 RPL 552237 / Page 3

Nomenclature Serial Number 3 Z F 12345 00 Plant Identification 3 = Faribault, MN 9 = Scottsboro, AL Engineering Revision Sequence Number Year of Manufacture A = 1971 R = 1986 B = 1972 S = 1987 C = 1973 T = 1988 D = 1974 U = 1989 E = 1975 V = 1990 F = 1976 W = 1991 G = 1977 X = 1992 H = 1978 Y = 1993 J = 1979 Z = 1994 K= 1980 5 = 1995 L = 1981 6 = 1996 M = 1982 7 = 1997 N = 1983 8 = 1998 P = 1984 Q = 1985 Month of Manufacture A = January J = September B = February K = October C = March L = November D = April M = December E = May F = June G = July H = August Air Handler; MSL Size 190 Vintage C Rev. B 09/16 RPL 552237 / Page 4

Nomenclature Model Number MSL 190C 1 12 AL 11 Y YY Y H YYYY Y RD4V1 Y Y YYYY A N Code 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 YYYY P2 YYYY SBD1 YYYYYYYYYYY YYYYYYYYYYY YYYYYYYYYYY Y Code 19 20 21 22 23 24 25 26 Code 01= Unit Type- Central Air Handler MSL= Medium Pressure, Single Zone, Low Pressure Coil Code 02= Unit Size/Vintage 190C= Single Fan, Nom. 90 Sg. Ft. Cabinet Code 03= Fan Discharge 1= Top Horizontal 4= Upblast Code 04= Electric Power Supply 12= 208/60/3 27= 460/60/3 29= 230/60/3 28= 380/50/3 Code 05= Starting Option AL= Across Line PW= Part Winding Code 06= Insulation and Liners 11= 1", 3/4# Insulation, Drain Pan & Floor Liners 12= 1", 3/4# Insulation, Drain Pan & Door Liners 13= 1", 3/4# Insulation, Drain Pan, Floor & Door Liners 21= 1", 3/4# Insulation, Floor Liners 22= 1", 3/4# Insulation, Door Liners 23= 1", 3/4# Insulation, Floor & Door Liners Code 07= Electrical Power Package Y= None Code 08= Aways YY Code 09= Aways Y Code 10= Fan Motor Type H= High Efficiency Motor Y= Standard Motor Code 11= Aways YYYY Code 12= Access/Spacer Section A= With 1 Secton Upstream Y= No Section Code 13 Fan, Motor & Drive R D 4 V 1 Fan RPM Discharge 1= Top Horizontal,CW 4= Upblast, CW Variable Inlet Vane A= Airfoil V= Airfoil with Vanes Fan RPM Range (With 1800 Nom. RPM Motor) Fan Wheel Diameter D= 40" Airfoil E= 44" Airfoil F= 48" Airfoil Motor Horsepower M= 15HP Q= 30HP T= 60HP N= 20HP R= 40HP U= 75HP P= 25HP S= 50HP W= 100HP Code 14= Aways Y Code 15= Aways Y Code 16= Aways YYYYY Code 17= Filter Section A= 2" Throwaway- Angular B= 2" Cleanable- Angular C= Bag Filter Section (45% Nom. Eff.) w/o Prefilters D= Bag Filter Section (45% Nom. Eff.) with Prefilters E= Bag Filter Section (95% Nom. Eff.) with Prefilters F= A & B, w/o Filters G= 2" Pleated Throwaway- Angular (35% Nom. Eff.) H= C, D, & E w/o Filters Y= None (No Section) Code 18= Mixing Box N= Back & Top Dampers M= Back & Bottom Damper Y= None Code 19= Aways YYYYY Code 20= Dummy Coil Casing P2= Between 2-Row Preheat & Cooling Coils P4= Between 4-Row Preheat & Cooling Coils P6= Between 6-Row Preheat & Cooling Coils P8= Between 8-Row Preheat & Cooling Coils R2= Between 2-Row Cooling & Reheat Coils R4= Between 4-Row Cooling & Reheat Coils R6= Between 6-Row Cooling & Reheat Coils R8= Between 8-Row Cooling & Reheat Coils YY= None Code 21= Aways YYYY Code 22= Coil Section S B D 1 Connection Location D= Drive Side (RH) E= Opposite Drive Side (LH) Face & Bypass B= Internal Face & Bypass Y= None Section S= Single L= Stagered W= Wide Single Y= None YYYY= None Code 23= Preheat Coil- Aways YYYYYYYYYYY Code 24= Cooling Coil- Aways YYYYYYYYYYY Code 25= Heating Coil- Aways YYYYYYYYYYY Code 26= Disconnect Switch- Aways Y Code SY* SB* LY* LB* WY* 1 84 - - 108 108 90 2 78 - - 102 102 84 3 72 - - 96 96 78 4 66 66 90 90 - - 5 60 60 - - 84 - - 6 54 54 - - 78 - - 7 - - - - - - 72 - - Air Handler; MSL Size 190 Vintage C Rev. B 09/16 RPL 552237 / Page 5

Coil Notes & Sample Contractor Coil Code Strings Note: ALL Central Station Air Handlers use "Contractor" style coils. Contractor Coils are ordered as SEPARATE LINE ITEMS on the GO/General Order (Example: 976230-017), so they DO NOT have standard nine digit Daikin Applied part numbers. When a replacement Contractor Coil is required a Contractor Coil Quote needs to be prepared. To quote a replacement Contractor Coil it is necessary to obtain model and serial number information from the unit nameplate and then contact Daikin Applied. If the unit has more than one coil it will be necessary to confirm which coil(s) are needed BEFORE quoting. Note that the sample code strings shown below are incomplete and DO NOT furnish enough information to correctly quote a Contractor Coil. GO and/or serial number information is required in order to properly quote a Contractor Coil. In some instances, coils were manufactured separately from the unit and may have a unique serial number such as 9Z12345-00. A coil with a serial number starting with a "9" was built in Scottsboro AL and may or may not have been installed in a unit before shipment. COIL TYPE Water: 5M, 5W, 5K, 5P, 5Q Booster: 5B CIRCUITING Water: Q = 1/4 Serpentine H = 1/2 Serpentine L = 3/4 Serpentine S = 1 Serpentine M = 1-1/2 Serpentine D = 2 Serpentine B = 3 Tube Center Sample Contractor Coil Code Strings Booster: S = 1 Circuit D = 2 Circuit B = 3 Tube Center Coil Notes 5W H - 10 02 C - 033.00-090.00 FINNED LENGTH (INCHES) FIN HEIGHT (INCHES) FIN DESIGN B = 01, 02, 03 & 04 ROW E-F5 C = 01, 02, 03 & 04 ROW HI-F5 ROWS DEEP (01, 02, 03, 04) FINS PER INCH (06, 07, 08, 09, 10, 11, 12, 13, 14) 5 SA - 12 02 C - 033.00-090.00 FINNED LENGTH (INCHES) TUBE O.D.: 5 = 5/8 inch 8 = 1 inch FIN HEIGHT (INCHES) COIL TYPE: 5SA = Single tube, opposite end connection 5JA,8JA = Distributing tube, same end connection 8RA = Distributing tube, opposite end connection 5HA = High pressure construction, single tube, opposite end connection 5GA,8GA = High pressure construction, distributing tube, same end connection 8TA = High pressure construction, distributing tube, opposite end connection FIN DESIGN: B = 01 & 02 ROW E-F5 C = 01 & 02 ROW HI-F5 B = 01 ROW HI-F8 (1 ) ROWS DEEP: HI-F5, E-F5 (01, 02) HI-F8 (01) FINS PER INCH: HI-F5, E F5 (06, 07, 08, 09, 10, 11, 12, 13, 14) HI-F8 (03, 04, 05, 06, 07, 08, 09, 10, 11, 12, 13, 14) COIL TYPE Water: 5M, 5W Evaporator: 5E CIRCUITING Water: H = 1/2 Serpentine L = 3/4 Serpentine S = 1 Serpentine M = 1-1/2 Serpentine D = 2 Serpentine Evaporator: N = Normal F = Face Control R = Row Control J = Interlaced K = Interlaced Face Control 5W S - 10 06 C - 18 x 45 FINNED LENGTH (INCHES) FIN HEIGHT (INCHES) FIN DESIGN C = HI-F5 B = E-F5 ROWS DEEP ( 02, 03, 04, 05, 06, 08, 10, 12) FINS PER INCH (06, 07, 08, 09, 10, 11, 12, 13, 14) Air Handler; MSL Size 190 Vintage C Rev. B 09/16 RPL 552237 / Page 6

Blower Fan Section Diagrams 40 Diameter Fan Size 7 4 1 CW 5 6 2 CCW 44 & 48 Diameter Fan Size 7 4 3 5 6 Air Handler; MSL Size 190 Vintage C Rev. B 09/16 RPL 552237 / Page 7

Ref. No. N/S Motors, Sheaves & Belts * Blower Fan Section Components Part Description Part Number 1 Blower Wheel, CW 003194701 1 2 Blower Wheel, CCW 003194801 1 3 4 N/S 5 6 7 Fan Size 40" 44" 48" Blower Wheel 023392420 1 Blower Wheel 023392421 1 Inlet Funnel Assy 031940905 2 Inlet Funnel Assy 017898911 2 Inlet Funnel Assy 017898912 2 Inlet Vane Assy, CW 032739700 1 Inlet Vane Assy, CCW 032739100 1 Inlet Vane Assy, CW 024029729 1 Inlet Vane Assy, CCW 024029730 1 Inlet Vane Assy, CW 024029731 1 Inlet Vane Assy, CCW 024029732 1 Drive Shaft 041744000 1 Drive Shaft 041740200 1 Drive Shaft 041273300 1 Bearing, Pillow Block, 2 15/16" 020648609 2 Bearing, Pillow Block, 3 7/16" 020648614 2 Bearing, Pillow Block, 3 15/16" 020648615 2 Scroll Housing Assy 041743800 1 Scroll Housing Assy 041008200 1 Scroll Housing Assy 041272100 1 Discharge Housing Assy- Top Horizontal 042011901 1 Discharge Housing Assy- Top Horizontal 041741501 1 Discharge Housing Assy- Top Horizontal 041272201 1 Discharge Housing Assy- Upblast 043842801 1 Discharge Housing Assy- Upblast 043287901 1 Discharge Housing Assy- Upblast 044294201 1 Discharge Housing Assy- Top Horiz. w/variable Inlet Vanes 042011902 1 Discharge Housing Assy- Top Horiz. w/variable Inlet Vanes 041741502 1 Discharge Housing Assy- Top Horiz. w/variable Inlet Vanes 041272202 1 Discharge Housing Assy- Upblast w/variable Inlet Vanes 043842802 1 Discharge Housing Assy- Upblast w/variable Inlet Vanes 043287902 1 Discharge Housing Assy- Upblast w/variable Inlet Vanes 044294202 1 N/S= Not Shown. * Contact Daikin with unit model & serial number. Air Handler; MSL Size 190 Vintage C Rev. B 09/16 RPL 552237 / Page 8