Integrated Power Solutions

Similar documents
Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Switchgear Skid, C1192

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Contents. Page INTRODUCTION Power/Vac GUIDE FORM SPECIFICATION thru

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

Solar Power Switchgear & Energy Storage Renewable Energy Systems

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Tradition. Technology. Innovation.

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

TECHNICAL AND APPLICATION GUIDE. SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear

MEDIUM VOLTAGE SWITCHGEAR SECTION

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear

MEDIUM VOLTAGE PRODUCTS

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Three-Phase Pole Mounted Recloser

Metal Clad VCBs ~ Mk1

Horizontal Circuit Switchers

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

SWITCHGEAR DIVISION PRODUCT PROFILES

MASTERCLAD Metal-Clad Indoor Switchgear

Medium & Low Voltage Switchgear. Project Highlights

Electrical Switchgear Replacement Montgomery County Community College

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

C1000 Series Automatic Cap Bank

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

TECHNICAL AND APPLICATION GUIDE. SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Horizontal Circuit Switchers

Power/Vac OEM Express Switchgear

Technical guide. Advance kv medium voltage, metal-clad switchgear

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Publication No.: PSG

University of Houston Master Construction Specifications Insert Project Name

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Metal-Clad Indoor Switchgear

with Vacuum Circuit Breaker HAF

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Basics of Medium Voltage Motor Control Starter Power Components & Starter Types

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

NOTICE OF ADVERTISEMENT FOR BIDS. Furnishing and Delivery of 15kV Sheltered Aisle Switchgear For Wilton Light and Power Wilton, Iowa, 52778

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Power/Vac Switchgear Concepts And Basic Configurations

Underground Distribution Switchgear

Chapter 6 Generator-Voltage System

Extensible Unit - VCE2a

A. Submittals shall be made in accordance with Division 1, Section

The safest, most reliable Switchgear in the market today

Product Specifications for Aluminum Vertical Break Switches

GE Energy Connections Industrial Solutions. DET-882 Application and Technical Guide. SecoGear

7. SERVICES OVER 600 VOLTS

Ampgard The name motor applications rely on

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use.

MESG 12 / 17.5 / 24 / 36 KV

Metal-enclosed medium-voltage power factor correction system

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Section 18. Medium Voltage Equipment. BuyLog Catalog 18-1

Technical Specification for Pole Mounted Capacitor Rack

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Switchgear Arrangement, Torque Requirements, Insulation Systems & Maintenance Intervals. Mike Schmaderer

POWERCON CORPORATION

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Unit Substation Transformers 5 and 15 KV Class

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

Advance 27 ANSI 27 kv switchgear

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

MEDIUM-VOLTAGE SWITCHGEAR

METAL ENCLOSED STANDARDIZED MEDIUM VOLTAGE SWITCHBOARDS, INSULATED IN AIR AND SF6 GAS UP TO 36KV

MaxSG Low Voltage Switchgear

Digital Paralleling. PowerCommand Medium Voltage Digital Paralleling Systems

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Transcription:

Integrated Power Solutions Low & Medium Voltage Distribution Power Distribution Centers Skid-Mounted Substations Custom Control & Automation ESS Metron Proposal 64000V1 DATE: PAGES (including cover): 7 TO: Phone: ATTN: FAX No.: FROM: Email: SUBJECT: Reference: Drawings & specifications provided at time of quote ESS Metron is pleased to offer the following proposal: ITEM #1 15kV & 5kV Switchgear Lineups $.00 ITEM #1A 15kV Switchgear ITEM #1B 5kV Switchgear ITEM #2 Remote Racking Device $.00/ each ITEM #3 Breaker Lift Truck $.00 / each ITEM #4 Breaker Test Cabinet $.00 / each ITEM #5 Remote Breaker Control Panel $.00 / each ITEM #1A 15kV (13.8kV Operating) Switchgear Lineup (NP1-13.8-1/2): 9-Section Switchgear Lineup with the following features: Overall Switchgear Approximate Dimensions: 94 D x 324 W x 95 H Enclosure: Metal Clad Switchgear, N1 (indoor), free standing, front/rear access, front door compression latch mechanisms, hinged front doors, bolted rear panels, powder coat finish, ANSI-61 light gray. Main Bus: 15kV (13.8kV Operating), 1200A, 63kA, 95kV BIL, 3-Phase, 3-Wire, 60HZ, tin plated copper with fluid bed epoxy insulation and boots, porcelain insulators and bus support Ground Bus: ¼ x 2 tin plated copper Space Heaters: 120/240VAC, 300W w/ Thermostat (in each switchgear section) Remote Racking: Remote Breaker Receptacle for each Circuit Breaker, mounted on front door (for use with Portable Remote Breaker Operator, ITEM#2) SECTION 101 Feeder Breaker (52-11): -(1) Protective Relay, SEL 551C, P/N 0551C0BX553X age 1 of 7 ESS Metron 1505 W. Third Ave. Denver CO 80223 Phone 303.592.1903 Last saved: 1/16/2012 10:57:00 AM By: B

SECTION 102 Feeder Breakers (52-9 & 52-7): -(4) Lockout Relay, Electroswitch, 24 Series -(4) Indicating Light, 125VDC, white (LOCKOUT) -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-9 -(3) CT s, 2000:5, single ratio, line side connected, for breaker 52-9 -(1) Zero Sequence CT, 50:5, for breaker 52-9 -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-7 -(3) CT s, 2000:5, single ratio, line side connected, for breaker 52-7 -(1) Zero Sequence CT, 50:5, for breaker 52-7 SECTION 103 Feeder Breakers (52-5 & 52-3): -(1) Transformer Protection Relay, SEL 787, P/N 07870X1ABA0X0X850400 -(4) Lockout Relay, Electroswitch, 24 Series -(4) Indicating Light, 125VDC, white (LOCKOUT) -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-5 -(3) CT s, 2000:5, single ratio, line side connected, for breaker 52-5 -(1) Zero Sequence CT, 50:5, for breaker 52-5 -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-3 -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-3 -(3) CT s, 2000:5, single ratio, line side connected, for breaker 52-3 -(1) Zero Sequence CT, 50:5, for breaker 52-3 SECTION 104 Main Circuit Breaker (52-1) and PT/CPT: -(1) Line PT Drawer: (3) PT s, 14400V-120V, wye, fused (E-Rated), drawout type (Top Compartment) -(1) Line CPT Drawer: (1) CPT, 13800V 120/240, 15 KVA, single phase w/ fuses (E-rated) (Top Compartment) Page 2 of 7

-(1) High-Impedance Differential Relay, SEL 787Z, P/N 0587Z0X325512XX -(3) CT s, 1200:5, multi ratio, bus side connected -(3) CT s, 2000:5, single ratio, line side connected -(1) Zero Sequence CT, 50:5 -(3) Surge arrestors, 15kV, Station Class SECTION 105 Tie Breaker (24-1) and Bus1PT: -(1) Bus PT Drawer: (3) PT s, 14400V-120V, wye, fused (E-Rated), drawout type (Top Compartment) -(3) CT s, 1200:5, multi ratio -(6) CT s, 2000:5, single ratio SECTION 106 Communication Cabinet and Bus2PT: -(1) Bus PT Drawer: (3) PT s, 14400V-120V, wye, fused (E-Rated), drawout type (Bottom Compartment) -(1) SEL 2890MIX -(1) SEL 240700013 Satellite-Synchronized Clock -(2) SEL 35303B0DX211X0XXXXXX -(1) SEL 235-0103 Legacy GPS Antenna -(2) SEL 2886 SECTION 107 Main Circuit Breaker (52-2) and PT/CPT: -(1) Line PT Drawer: (3) PT s, 14400V-120V, wye, fused (E-Rated), drawout type (Top Compartment) -(1) Line CPT Drawer: (1) CPT, 13800V 120/240, 15 KVA, single phase w/ fuses (E-rated) (Top Compartment) -(1) High-Impedance Differential Relay, SEL 787Z, P/N 0587Z0X325512XX Page 3 of 7

-(3) CT s, 1200:5, multi ratio, bus side connected -(3) CT s, 2000:5, single ratio, line side connected -(1) Zero Sequence CT, 50:5 -(3) Surge arrestors, 15kV, Station Class SECTION 108 Feeder Breakers (52-4 & 52-6): -(1) Transformer Protection Relay, SEL 787, P/N 07870X1ABA0X0X850400 -(4) Lockout Relay, Electroswitch, 24 Series -(4) Indicating Light, 125VDC, white (LOCKOUT) -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-6 -(3) CT s, 2000:5, single ratio, line side connected, for breaker 52-6 -(1) Zero Sequence CT, 50:5, for breaker 52-6 -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-4 -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-4 -(3) CT s, 2000:5, single ratio, line side connected, for breaker 52-4 -(1) Zero Sequence CT, 50:5, for breaker 52-4 SECTION 109 Feeder Breakers (52-8 & 52-10): -(3) Lockout Relay, Electroswitch, 24 Series -(3) Indicating Light, 125VDC, white (LOCKOUT) -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-8 -(3) CT s, 2000:5, single ratio, line side connected, for breaker 52-8 -(1) Zero Sequence CT, 50:5, for breaker 52-8 -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-10 -(3) CT s, 1200:5, multi ratio, bus side connected, for breaker 52-10 -(3) CT s, 2000:5, single ratio, line side connected, for breaker 52-10 -(1) Zero Sequence CT, 50:5, for breaker 52-10 Switchgear Accessories: -(1) Standard set of accessories (manual charging handle, gag plate, breaker contact grease) Page 4 of 7

ITEM #1B 5kV (4160V Operating) Switchgear Lineup (NP1-4.16-1/2): 3-Section Switchgear Lineup with the following features: Overall Switchgear Approximate Dimensions: 94 D x 108 W x 95 H Enclosure: Metal Clad Switchgear, N1 (indoor), free standing, front/rear access, front door compression latch mechanisms, hinged front doors, bolted rear panels, powder coat finish, ANSI-61 light gray. Main Bus: 5kV (4160V Operating), 1200A, 50kA, 60kV BIL, 3-Phase, 3-Wire, 60HZ, tin plated copper with fluid bed epoxy insulation and boots, porcelain insulators and bus support Ground Bus: ¼ x 2 tin plated copper Space Heaters: 120/240VAC, 300W w/ Thermostat (in each switchgear section) Remote Racking: Remote Breaker Receptacle for each Circuit Breaker, mounted on front door (for use with Portable Remote Breaker Operator, outlined in Switchgear Accessories) SECTION 101 Main Circuit Breaker (52-1) and PT/PT: -(1) Vacuum Circuit Breaker, 5kV, 1200A, 50kA, 3-Phase, 3-Wire, 125VDC Control (Trip/Close/Charging -(1) Line PT Drawer: (3) PT s, 4200V-120V, wye, fused (E-Rated), drawout type (Top Compartment) -(1) Bus PT Drawer: (3) PT s, 4200V-120V, wye, fused (E-Rated), drawout type (Top Compartment) -(3) CT s, 1200:5, multi ratio, line side connected -(3) CT s, 4000:5, multi ratio, bus side connected SECTION 102 Tie Breaker (24-1): -(1) Vacuum Circuit Breaker, 15kV, 1200A, 50kA, 3-Phase, 3-Wire, 125VDC Control (Trip/Close/Charging -(1) SEL 35303B0DX211X0XXXXXX -(2) Ethernet Switch, NTRON 517FX, P/N 517FX-A-ST-S -(3) CT s, 1200:5, multi ratio SECTION 103 Main Circuit Breaker (52-2) and PT/PT: -(1) Vacuum Circuit Breaker, 5kV, 1200A, 50kA, 3-Phase, 3-Wire, 125VDC Control (Trip/Close/Charging -(1) Line PT Drawer: (3) PT s, 4200V-120V, wye, fused (E-Rated), drawout type (Top Compartment) -(1) Bus PT Drawer: (3) PT s, 4200V-120V, wye, fused (E-Rated), drawout type (Top Compartment) Page 5 of 7

-(3) CT s, 1200:5, multi ratio, line side connected -(3) CT s, 4000:5, multi ratio, bus side connected Switchgear Accessories: -(1) Standard set of accessories (manual charging handle, gag plate, breaker contact grease) MV SWITCHGEAR CLARIFICATIONS / EXCEPTIONS: CLARIFICATION Our offering is based on our best interpretation of the drawings and specifications provided. Pricing is per the above bill of material only. Any deviation will require a pricing adjustment. CLARIFICATION MV Switchgear will be manufactured in accordance with ANSI/IEEE standard (C37.20.2). All Breakers, Frames, Control, Metering and Relaying components will be UL/UR listed. CLARIFICATION 125VDC control power to be provided by others. CLARIFICATION Our offering includes SEL Quickset Design Template LDG0003-01 to be loaded in the SEL 351S relays for MTM transfer scheme. Relay coordination study and final relay settings are by others. CLARIFICATION HRG system is not located in the proposed switchgear and is not included in our offering. CLARIFICATION Provisions will be made for bus duct connection for breakers 52-1 and 52-2 in ITEM#1B. Bus duct is to be provided by others. EXCEPTION Relay Coordination Study is not included in our offering. EXCEPTION Exception is taken to all references to arc resistant switchgear. EXCEPTION Field Services are not included in our Offering. Terms and Conditions: COMMODITY METAL PRICE DISCLAIMER Due to highly unstable commodity metal prices related to factors beyond our control, ESS Metron is unable to hold its prices firm for longer than 30 days. We are making every effort to minimize the impact of such variations and appreciate your understanding. Orders placed later than 30 days after quotation are subject to a price revision based on most current metal commodity pricing. Shipment: Warranty: FOB: Quote Validity: Payment Terms: Engineering Design Submittal Drawings: Fabrication, Assembly and Wiring: One (1) year from date of commercial use or operation, or eighteen (18) months from date of delivery by Seller, whichever comes first. FOB - Factory, Denver, Colorado. Freight prepaid and allowed. Prices Valid Thirty (30) Days from the date of this Proposal All Payments are NET 30 Days after invoice issue Page 6 of 7

If you have any questions or comments, please do not hesitate to contact me. Sincerely, Brock Blue ESS Metron bblue@essmetron.com Phone: 720-236-2579 Page 7 of 7