Training Bulletin New Model Introduction

Similar documents
TECHNICAL SERVICE GUIDE

Pro and Designer Series Ventilation

TECHNICAL SERVICE GUIDE

36 & 48 ISLAND AND WALL CANOPY RANGE HOODS

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Section 7 - Troubleshooting Guide

IMPORTANT SAFETY INSTRUCTIONS

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

PARTS & SERVICE MANUAL

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

INDEX Section Page Number Remarks

INDEX D1776 DISHWASHER (DW953)

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

Electronic Refrigerator Diagnostics

MODEL SCA Installation and Operation Manual Important:

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

PROFESSIONAL WALL HOODS PH30ZS, PH36ZS, PH42ZS, PH48ZS, PH54ZS

SERVICE NOTEBOOK VIPR (DOWNDRAFT)

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

IMPORTANT SAFETY INSTRUCTIONS

Designer Wall Range Hood Installation. Installation Tutorial Video

Cover. L5v2 Plug-In Conversion Module(PCM) Diagnostic Trouble Codes

Theimer Printing Light Assemblies VIOLUX 4002T VIOLUX 6002T VIOLUX 8002T. Instruction Manual

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

No Operation of air conditioner Explanation

AIRSTREAM - BATTERY CONTROL CENTER - Diesel

FiveFish Studios PSU-2448Plus+ Assembly Guide

Assembly Instructions MP-P2 Power Supply and Chassis Base Plate

MICROWAVE OVEN HOOD COMBINATION

DCX2496 Linear Power Supply mod by

5. Alignment and Adjustments

EMERGENCY VEHICLE BATTERY MANAGER PS2024

SERVICE MANUAL IMPINGER COUNTERTOP OVEN MODEL 1300 SERIES

Electronic Service Manuals

CATALOG OF REPLACEMENT PARTS

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

SERVICE MANUAL (INTERNATIONAL)

Troubleshooting Guide: 355 Lights (24V)

Troubleshooting Guide: 355 Lights (12V)

PARTS AND SERVICE MANUAL

CATALOG OF REPLACEMENT PARTS

Hayward error codes and troubleshooting

SUPER CAPACITOR CHARGE CONTROLLER KIT

HDC Inc. Left. Right. Pivits Universal mounting threaded for shoulder bolt and stud clip. 2 each per kit

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

ATLAS Wheel Balancer Electrical Flow Chart

ALU-29CF Portable Light NSN:

Subject Underhood G System Error Codes and Symptoms System or Parts affected

Mobile Diesel Heaters TOR / MIR Technical Training Course

QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC)

IFD AIR CLEANER SERVICE MANUAL

NE-1027 NE Microwave Oven. BTQ (U.K.) ETG (Continental Europe) ORDER NO.PHAMOS C2


Electronic Circuit Breaker ESS20-0..

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

RigMaster Power Service and Repair Manual Document # S901009

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

Range Hoods Removing Control Switches Removing Blower Motor Wiring Diagrams

9.2, 9.2s, 9.20, 9.20s Treadmill

MODEL ELC-12/40-CVM-D BATTERY CHARGER

CATALOG OF REPLACEMENT PARTS

OPERATING INSTRUCTIONS AND SERVICE MANUAL FOOTBALL SCOREBOARD MODEL MP-3455 WITH MP-3000 CONTROL

Order Number MOP C2. Microwave Oven

EB Conveyor Maintenance Guide

PHOENIX MINI-GUARDIAN

Troubleshooting 3Z8 038 Rev B

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

HAN-L62 MOUNTING PLATE

Installation Instructions

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

AUTOMATIC FOODSERVICE EQUIPMENT. AUTOMATIC ELECTRIC BROILER MODELS 824E & 850E and 624E & 650E. B-Series Broiler OWNER S MANUAL

FMV156DBF FMV156DCG FMV156DQF FMV156DSF

Fan Coil Unit (FCU) Fan Motor Control

NIDAC EMC Communicating Motor

Installation Instructions

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

Battery Control Center - Diesel

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Body Electrical System

2. Milk does not heat and the heater is not hot. a. Is there power getting to the pasteurizer heater? Check the incoming voltage to the contactor

Name: ACORN Inc. Address: 6450 Kingspointe Parkway, Unit 1, Orlando, Florida, IMPORTANT!

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

AUTOMATIC FOODSERVICE EQUIPMENT. AUTOMATIC ELECTRIC BROILER MODELS 952E, 932E and 922E OWNER S MANUAL

BLOWER VACUUM SWITCH FAILED OPEN

Wall Mount Chimney Style. Island Mount Chimney Style. Wall Mount Professional Style. Insert Mount Professional Style

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Transcription:

GE Monogram GE Consumer Service Training Training Bulletin New Model Introduction October 2001/ TB-14-01 ZV950SDSS Wall-Mount Euro-Style High Performance Vent Hood Purpose To introduce the new wall-mount Euro-style High Performance vent hood, Model ZV950SDSS and describe the differences from the previous wall mount version ZV750SY, as referenced in Training Manual Pub. No. 31-9043. Design differences are product shape and new graphics control panel. Features For 36" cooktop surfaces 660 CFM dual blower rating Vertical exhaust Electronic touch controls 4 speeds 4 halogen lamps with 6 lighting levels Low light/night light setting 3 removable filters with filter cleaning reminder Automatic delayed fan shut-off (5/10/20 mins.) Service Instructions TO ACCESS COMPONENTS: 1. Remove two screws from top duct cover at ceiling and slide top cover down. 2. Lift and remove both duct covers. Set covers aside. TO REMOVE S: For access to lighting and wiring 1. Push tab back. 2. Tip the filter down. 3. Slide filter out. TE: Review Operation & Service Diagnostic Flow Chart before removing any components. OPERATION OF FRONT PANEL CONTROL PUSHBUTTONS AND LED DISPLAY Fan Keypad Operation 1- ON/OFF Remembers the last fan speed used 2 - Decreases speed 3 - Increases speed 4 - High speed Boost 5 - Delayed shut-off Choose 5, 10 or 20 minutes by pushing this button (see item 10). Hood Light Keypad Operation 6 - Light ON/OFF Remembers the last light level used 7 - Dims light 8 - Brightens light Display LEDs 9 - Lights after 30 hours of ON time to remind you to clean the metal grease filters. The light blinks until the filters are replaced. Then the timer resets automatically. 10 - Indicates delayed time setting 11 - Fan operating symbol INSTALLATIONS WITH 10 FT TO 14 FT DUCT COVERS: 1. Remove two screws from top duct cover, slide top piece down. 2. The bottom duct piece is secured with wall anchors. Remove screws and washers, lift off both pieces and set aside. Inner Duct Top View Wall Anchors Outer Duct 1 2 3 4 9 11 10 5 6 7 8 05 10 20 N.D. 112-08

ELECTRONIC CONTROL DESCRIPTION The electronic hood control system consists of Capacitor the following parts: 1) Entry/Display Assembly 2) Control PCB 3) Triac 4) Fuse Holders 5) Motor Capacitor 6) Induction Fan Motors Transformer 7) Transformer Fuses, Triac, 8) Halogen Lamps Motor 9) Filter Microswitch Connections Frame with Control Panel Slides Out For Service CAUTION: Components on the electronic control are electrically HOT when voltage is connected to the hood. Control PCB Box 1) ENTRY/DISPLAY ASSEMBLY The replacement assembly has a PCB mounted in a plastic enclosure with (8) push buttons. It consists of the Fan Touch Control, Lamp Touch Control and the Display PCB. TO CHECK OPERATION OF CONTROL PCB: Check that all six connectors are locked Motor Capacitor Control PCB in place, no leads are broken and connector solder joints are not broken on PCB copper side. Right Blackbox 3) The triac controls the four hood lamps and is mounted in a blackbox in the left chimney area. Triac has an isolated case, which is mounted with two screws. IMPORTANT: Triac wire connection must be correct or lamp flickering could occur. Triac can be checked for electrical short by removing the black lead and measuring the resistance between the two 1/4" terminals (terminals with black and brown wires). Resistance should be greater than 1M ohm. Transformer Brown Triac Access to this assembly is by removing internal screws on the chassis sides and sliding the frame outward about 6 inches. The display assembly may then be removed by unplugging the ribbon cable, loosening the thumbscrews, and sliding the display box assembly out of the frame. Remove 2 Inside Screws Strain Relief Motor Connections Fuse Holders Black Orange Blower Arm Mounting Screws (2 Front, 2 Rear) Left Blackbox Unplug Ribbon Cable Ribbon Cable IMPORTANT: Before replacing the assembly, check the operation of the hood by plugging the new Entry/Display Assembly into the existing ribbon cable. If the unit does not work, replace the control board first and then recheck to determine if the existing Entry/Display Assembly is functioning properly. 2) CONTROL PCB This PCB has the AC to DC power supply, microprocessor and fan relays and is located in the right blackbox in the hood chimney area. TE: The five green connectors are locking type. Use a small flat blade screwdriver to unlock as follows: Insert screwdriver in the center of the space between the plug and connector receptacle on the PCB. Push down on the screwdriver and pull out the plug at the same time. 2 4) FUSE HOLDERS The fuse holders are an in-line type, which is in series with 12V AC from the transformer and is located in the left blackbox. An open fuse may be caused by a lamp failing or wrong wattage lamp. TE: The fuses are 5 x 20 mm and rated at (5) A, 125V AC. (WB27X10542). 5) CAPACITOR The capacitor is mounted on right chimney and plugs into the Control PCB connector CN3. Fan Motors Rear Filter Channel Change Lamps (4)

6) INDUCTION FAN ASSEMBLY Motors are four speed capacitor run induction types, each rated at 120V AC/1.8A. ASSEMBLY Remove rear filter channel (2 screws and tabs) Remove motor leads from connector in left blackbox and loosen strain relief Remove (4) screws from top of chassis Remove (1) retainer screw from underside of motor base (see illustration below) Lower motor down (recommend (2) person job) Motor stator winding resistances: Orange-Red = 17 ohms Blue-Black = 17 ohms Blue-White = 8.5 ohms Motor connections are located in the left blackbox. Blower Retainer Screw 7) TRANSFORMER The transformer provides 12V AC to the hood lamps and the Control PCB power supply. It is attached by screws from the top of the chassis. 8) HALOGEN LAMPS The four halogen lamps are the push-in type rated at 12V AC/20W. The equivalent GE lamp is a Q20MR16/C/CG40 - BAB (W808X10002). 9) MICROSWITCH (Located in front center filter channel) Microswitch is mounted in the filter area and senses when filters are removed which causes the red display light to blink continually. The red display light turns ON after 30 hours of fan operation to remind the user to clean the filters. Make sure the filter is seated properly when installed or filter light will blink. 10) IMPLEMENT HOLDER RODS To access Implement Holder Rods, remove Entry Display Assembly by following the instructions in Step 1. Screws (2) holding the implement holders can now be removed from the outside. Order replacement Part WB03X10148. 11) REINSTALL DUCT COVERS If 10 ft. to 14 ft. duct covers, reinstall screws and washers. Secure duct cover to the ceiling bracket. Differences in Accessing and Servicing 1. Dual Blower Package: A 660 CFM blower assembly replacement as an assembly only. Service Improvements: The rear hood chassis channel can be removed with (2) screws to facilitate easier blower removal. There is a motor retainer screw holding the motor to the chassis so that the motor will not fall when the (4) mounting bolts are removed from the top of the chassis. The motor connections to the control board are located in a terminal block in the left blackbox on top of the chassis. 2. Display Control Location and Alignment: Now located in a pull-out control panel enclosure. Service Improvements: Access to the display gained by removing (2) screws and then sliding the control enclosure out. Alignment collars are molded to the display control box cover to slide into the control panel holes which aids in positioning of display-to-control panel. 3. Motor Capacitor: Located on right side above the chassis. Service Improvements: Instead of soldered terminals, now has PUSH-ON terminals. 4. Fuse Holders: As a reliability improvement, instead of (1) 8 amp fuse, the ZV950 has (2) - 5 amp fuses one for each set of (2) lamps. 5. Low Voltage Transformer: Located on left side above chassis. Service Improvement: Easily removable by (2) screws attaching LVT to the left side control bracket. 6. Power Control: The control circuit and power board are identical to the ZV750 model. 7. Implement Holder Rods: To access Implement Holder Rods, remove Entry Display Assembly (see Step 1, page 2). Screws (2) holding the implement holders can now be removed from the outside. Order replacement Part WB03X10148. 8. Diagnostic Flow Chart: Identical to the ZV750 chart with the addition of 2 fuses instead of one. 9. Mini Manual: Accessed by exactly the same method as the ZV750. Lift and remove the lower decorative duct cover, mini manual located in an envelope on the left blackbox cover. 10. High Ceiling Kit: There is a decorative duct cover accessory kit ZX14SD available for ceiling heights greater than 10 ft. and up to 14 ft. An 8 foot ceiling duct cover is supplied with the ZV950 model, both are installed in the same manner. 1-7/8" Cover Recess Into Top of Hood 25-1/2" to 30" for 10 ft. to 13 ft. Ceilings 30" Min. for 14 ft. Ceilings 36" Min. 10" Hood Height 3

CAUTION WARNING DISCONNECT POWER BEFORE SERVICING DO T TOUCH ELECTRICAL OR UNGROUNDED METAL PARTS WHILE SERVICING WITH POWER CONNECTED. SERVICE DIAGSTIC FLOW CHART PUSH BUTTONS STUCK? PUSH BUTTONS STUCK? UNSTICK/ADJUST TE #2 ENTRY/DISPLAY SUBASSEMBLY REMOVE LEAD ORDER/ INSTALL FAN ALWAYS ON? ON? FLICKERING? FIX/ ORDER CHECK/MODIFY CONNECTIONS FLICKERING? RED DISPLAY LIGHT BLINKING? FAN BLADES BLOCKED? CONTROL PCBS REMOVE/ RE-SEAT RIGHT INSPECT PCB IN BOX TE #1 ENTRY/DISPLAY ASSEMBLY & CONTROL PCBS CONTROL DEAD? CHECK IF 120V AC IS PRESENT AT TERMINAL BLOCK (IN LEFT BOX) ORDER/ INSTALL TRANSFORMER ORDER TURN HOUSE CIRCUIT BREAKER OFF, THEN ON IS CONTROL OPERATION INSPECT PCB IN BOX TE #1 ENTRY/DISPLAY ASSEMBLY & CONTROL PCBS = ~ 120V AC AT TRANSFORMER PRIMARY? FIX WIRING FIX WIRING REMOVE RIGHT CHECK/ADJUST MICROSWITCH Note #1 Check parts in the blackbox as follows: All six connectors are locked in place and no leads are broken. Connector solder joints are not broken on PCB copper side. Fuses are OK. Capacitor (25uf 250V AC); Check that cap is not open or shorted by using VOM. Note #2 Check for button protrusion through the hood holes and that buttons have movement. RED DISPLAY LIGHT BLINKING? RED DISPLAY LIGHT BLINKING? = ~ 120V AC AT? FUSES IN BOX REPLACE UNIT W = ~ 12V AC AT CONNECTOR (CN4B) IN BOX? SCHEMATIC DIAGRAM GREEN GREEN 120V AC CONTROL PCB M M CN1 CN2 CN3 CN5 LINE GND NEUT. RED RED CN4B CN4A GREEN SCHEMATIC ZV950 120V CN2 CN1 TRANSFORMER CN3 CAP. BROWN EMI RELAYS 25 µf 250V AC 12 VAC GREY CN4B CN5 5A125V - 5X20MM FUSES BROWN (2) RED LOW VOLTAGE POWER SUPPLY MICROPROCESSOR CIRCUIT CN4A VIOLET MICRO- SWITCH ISOLATED A1 G 2 LAMPS 12V AC 20W A2 2 LAMPS 12V AC 20W 4

Consumer Issue List Listed below are issues that may arise and cause concern for the consumer. Please review the list to prevent unnecessary and costly service calls/repairs. Area of Concern Possible Causes What To Do Fan does not operate A fuse may be blown or a circuit Replace fuse or reset when the switch is on breaker tripped circuit breaker. Fan fails to Fan blade striking the hood shell circulate air Check for excessively soiled filter Clean filters in hot soapy water or wash in dishwasher. Fan operates but Check to be sure the filter is clean If replacing the filter does not moves air slower correct the problem, call for than normal service. Fan keeps going The motor is probably overheating and Check to be sure the filter off and on turning itself off. This can be harmful to is clean. If off and on cycling the motor continues, call for service. Fan filter light is Filters are not in place or not properly Replace the filters. on or is blinking seated If the filters are in, adjust them in place. ZV950SD1 Parts List Item Description Catalogue Number Qty. 1 Panel Frame WB63X10023 1 9 Grease Filter WB02X10396 3 14 Condenser WB17X10013 1 26 Lamp Bulb WB08X10014 4 56 Air Outlet WB07X10491 1 57 Non Return Flap WB02X10800 1 77 Display Window WB02X10801 1 113 Monogram Logo WB02X10364 1 (Substitute WB02X10364) 1 118 Bottom Duct Cover WB38X10063 1 119 Upper Duct Cover WB38X10064 1 130 Front Panel WB07X10492 1 133 Implement Holder Rod WB03X10148 2 166 Printed Circuit Board WB27X10553 1 200 Halogen Lamp Assembly WB08X10024 4 208 L.V. Transformer WB17X10002 1 223 Switch Button WB03X10149 1 250 Ring Nut WB01X10002 4 252 Microswitch Box WB07X10003 1 253 Microswitch WB24X10001 1 254 Microswitch Cover WB07X10004 1 479 Triac WB02X10402 1 2300781 5 amp Fuse WB27X10542 2 2300674 Fuseholder WB02X10647 2 CAS06001979 Blower Assembly WB26X10116 1 ASA080810476 Installation Hardware WB02X10802 1 AQI06107312 Display Board Assembly WB03X10150 1 31-20785 Mini Manual 1 49-80095 Installation Instructions 1 49-80102 Owner s Manual 1 31-9043 Training Manual 1 5

Parts Exploded View 6