CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

Similar documents
Fiber optic splice closure

CS Fiber Optic Splice Case. Instruction

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

INSTALLATION INSTRUCTIONS

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

COYOTE STP (Service Termination Point)

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

Installation Instructions Table of Contents

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

Environmental Distribution Center (EDC-06P-NH)

FOSC-400A4 INSTALLATION INSTRUCTION

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

COYOTE STP (Service Termination Point)

M14 AUTOMOTIVE SPARK PLUGS AND WIRES CONVERSION KIT INSTALLATION INSTRUCTIONS

8400 Series Fiber Distribution System

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

INSTALLATION INSTRUCTIONS

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

Materials List: Tools List:

2-row and All-row systems included.

FL2000 Termination/Splice Panels User Manual

Owner smanual. Banks Ram-Air Super-Scoop Chevy/GMC Pickups. with Installation Instructions

Installation Instructions Z-Gate Shifter

CENTRAL VACUUM SYSTEMS

Power Connection Kit installation instructions

Lexus ES Fine Mesh and Adaptive Cruise Control Fine Mesh Grilles Upper and Lower Replacements

FOSC-100 B/H FOSC-100 B2/H

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

100A Series Low Power FM Antenna

Technical Support (707)

HIGH FLOW COLD AIR INTAKE SYSTEM INSTALLATION INSTRUCTIONS D , D A

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

SWING DOOR SOFT ENCLOSURE (part# 16733)

Fiber Connector Shelf (CCS)

SPORTSTER SADDLEBAG KIT. i i02212

SUT-450-I ASSEMBLY REQUIREMENTS

Checker Unload Checkstand Installation Instructions

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Combine Cover Manual

Installation Instructions QUICKSILVER CONSOLE SHIFTER Fits: Chevelle / El Camino

Fiber Splice Panel Rack Mount User Manual

Installation Instructions Sport Shifter

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

VITALink Taped Splice Pigtail Crimp

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

Assembly Instructions

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

ET-PWR-END-KIT Installation Instructions (part #JSR00)

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

PEDCAP-R-2, R-3 & R-4S/4L-INT

IMPORTANT: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

Installation Instructions Right Hand Drive Megashifter

Slide on the heat shrink tubing and connect the wire to the color matched cable on the Junction Box, making sure to line up the cable properly

Light Truck MegaShifter

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

and Original Series Pickup Lift Mounting Instructions Fullsize Nissan Titan Trucks present T-420 BOLT-ON GUSSET PART#5257

Your Legal Fuel Tank Source.

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

WAVETRAX USER MANUAL

install o IIVIPORTANT - Savethese -&WARNING - -&WARNING - This appliance must -&WARNING - Before beginning the Mode_s PB970, PB975

Hurst VMATIC3 INSTALLATION

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

SUT-250-S (These instructions are used for SUT-250-SCLC also)

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

Installation Instructions Supertop for Truck

Clutch Operated Roller Shade with Fascia Installation Instructions

INSTRUCTION, TRAIL CHARGER KIT P/N

BLACK BOX. Fully assembled, ready-to-use wallmount cabinets. Elite Wallmount Cabinet User s Manual. Customer Support Information

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

DRYING SYSTEM ASSEMBLY AND OPERATING MANUAL

Z-Gate Universal Shifter

TRAC-Station BT Installation Instructions

SYSTIMAX 360 FTP Evolve Panel Instructions

FULL LENGTH HEADERS/ CATTED HEAD PIPES

Please read these instructions completely before proceeding with installation. Read all maintenance guidelines on page 7 before operating the vehicle.

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

TCI FastGate Shifter Installation Instructions

BLACKBIRD INSTALLATION SUPPLEMENT

3 Reenterable Encapsulated PST Dome Closure

PRO RATCHET UNIVERSAL SHIFTER

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

FlexJet - Flex Cable Replacement

Transcription:

CommScope MULTILAYERED 289-TYPE 63-460-32-03 BUILDING ENTRANCE PROTECTOR (BEP) Issue 5, February 2004 Material ID 847 364 882 INSTALLATION INSTRUCTIONS General This instruction sheet provides procedures for mounting and wiring the 289-type BEP. How to Contact Us To find out more about Carrier Apparatus products, visit us on the web at: http://cw.commscope.com/ For technical assistance regarding Carrier Apparatus products: contact your local CommScope account representative or Commscope technical support at -800-344-0223. Report any missing or damaged parts to CommScope customer service in Omaha, Nebraska, at -866-539-2795. Tools Required Level Flat- or cross-head screwdrivers, KS- or 26-type tool Tape measure or other measuring device Drill with a /8-inch (3.2 mm) wood bit. HOLE PATTERN FOR MOUNTING A SINGLE UNIT 7 IN. (78 mm) MINIMUM CAPACITY OF UNIT DISTANCE SEE TABLE /8-IN. (3.2 mm) DIAMETER PILOT HOLES 25 PAIR 50 PAIR 00 PAIR 5-IN. (27 mm) ½-IN. (292 mm) 24 ½-IN. (622 mm) WALL OR OTHER OBSTRUCTION AT LEAST 50 IN. (270 mm) FROM THE GROUND STEP A MOUNTING PROCEDURE, SINGLE-UNIT CONFIGURATION. Locate and drill two /8-inch (3.2 mm) diameter pilot holes as shown. Mounting template may also be used to locate two holes. 2. Install two lag screws (provided with unit) into pilot holes, leaving /8-inch (3.2 mm) clearance between screw head and mounting surface. On shingled or otherwise uneven surfaces, adjust lag screws to provide minimum play of unit. 3. Guide slots in left-side mounting brackets into clearance gap between screwheads and wall. Push unit to left as far as possible, allowing unit to drop down and seat on vertical slots located in side mounting brackets. 2007 CommScope, Inc. All Rights Reserved Printed in U.S.A. Page

63-460-32-03 4. Open unit door and, using holes in rear surface of unit as template, drill two holes with /8-inch (3.2 mm) diameter drill bit. Install two lag screws provided with unit. Tighten screws securely. See figure on next page. 5. Insert two hole plugs provided with unit. Remove any debris generated by drilling holes. STEP B MOUNTING PROCEDURE, STACKED CONFIGURATION. For mounting first 00-pair BEP, locate and drill two /8-inch (3.2 mm) diameter pilot holes as shown. 2. Install first 00-pair BEP as described in items 2 and 3 under "STEP A - MOUNTING PROCEDURE, SINGLE-UNIT CONFIGURATION." 3. Install two additional screws into hanger brackets located on top of first BEP. 4. Open unit door and, using holes in rear of unit as template, drill two holes with /8-inch (3.2 mm) diameter drill. Install two lag screws provided with unit. Tighten screws securely. 5. Insert two hole plugs provided with unit. Remove any debris generated by drilling holes. 6. Remove hood of first BEP after removing four wing nuts from inside of first BEP. (Save four wing nuts for later use in securing second BEP). 7. Remove plastic caps that were hidden under hood of first BEP. 8. Uncover studs located at bottom of protector unit to be stacked on top of first BEP. 9. Mount second BEP on top of first BEP by inserting bottom studs into corresponding holes of first BEP. Install four wing nuts onto four studs. 0. Open door of second BEP and, using holes in right rear-surface of unit as template, drill two holes with /8-inch drill. Install two wood screws and flatwashers provided with second unit. Tighten screws and insert two hole plugs provided with unit. Remove any debris generated by drilling holes.. For stacking additional units, repeat Steps 6 through of this page. Page 2

Issue 4, 63-460-32-03 WALL OR OTHER OBSTRUCTION 2 GUIDE LEFT-SIDE MOUNTING BRACKETS (REAR OF UNIT) ONTO LAG SCREWS MOUNTED ON WALL 6 REMOVE HOOD 3 7 IN. MIN. (78 mm) FIRST MOUNTING POSITION 24-/2 IN. (622 mm) 2 6 IN. (406 mm) 2 GROUND LEVEL 4 5 HOLE PATTERN FOR MOUNTING TWO OR THREE PROTECTORS IN A STACKED CONFIGURATION 2 289-TYPE BEP NO. 6 GROUND WIRE FURNISHED WITH PROTECTOR -IN. (254 mm) CORE WRAP SPLICE CHAMBER COVER 5 LOCALLY APPROVED BONDING CLAMP 5 HEX NUT 3 IN. (76 mm) 0 IN. (254 mm) FLATWASHER EXT. TOOTH LOCKWASHER 4 CABLE BOTTOM CABLE ENTRY Page 3

63-460-32-03 STEP 2 WIRING PROCEDURE, SINGLE- AND MULTIUNIT CONFIGURATION. Insert incoming cable through supplied cold shrink tubing, then into splice chamber of bottommost BEP. 2. Strip sheath from cable, 6 inches (52 mm) past entry gate into splice chamber. Free conductor length should be sufficient to reach top of uppermost BEP. Note: When terminating gel-filled cable, remove all filling compound from exposed conductors. Tightly wrap vinyl tape twice around first 3 inches (7.6 cm) of loose conductors extending beyond cable jacket. 3. Tighten incoming cable to bottommost strain relief bracket, using snap-lock clamp, provided with unit. 4. Fasten incoming cable to wall about 0 inches (254 mm) before BEP. 5. Install bond clamp (customer supplied) on incoming cable per local practices. Note: For gel-filled cable, tightly apply three wraps of vinyl tape around last 3 inches (76 mm) of cable jacket, bond clamp, and first 3 inches (76 mm) of loose conductors. Center of bond clamp must be left exposed to make contact with ground strap. 6. Connect No. 6 gauge (4 mm) flexible ground strap provided in bottommost splice chamber to bond clamp. Make sure ground strap is touching metal of bond clamp. Note: Only ground strap closest to cable entry point will be used to ground incoming cable. Ground straps of all other BEP units will be unused. 7. Terminate cable conductors onto splicing connectors used. 8. Dress splicing connectors and conductors neatly into splice chamber. Be careful to avoid any sharp bends or kinks in conductors. 9. Use short length of No. 6 gauge (4 mm) solid conductor wire to bridge grounds from top protector to middle protector and from middle protector to bottom protector. 0. Provide No. 6 gauge (4 mm) solid conductor from approved building ground to network ground.. Close splice chamber covers and secure top layers in closed position by using either KS- or 26-type tool, depending on type of security screw used on protector unit. 2. Close cover of outside enclosure. Page 4

Issue 4, 63-460-32-03 STEP 3 INSTRUCTION FOR CIRCUIT WIRING. Slide rear half of plastic cable bracket into mounted "U" shaped bracket. 2. Secure output customer cable to wall about 0 inches (254 mm) below bottom of protector. 3. Strip sheath from cable 5 inches (27 mm) past entry gate. Free conductor length should be long enough to reach farthest customer bridge of topmost protector. 4. Remove cable seal core to match diameter of cable to be used. 5. Wrap black cable seal (provided with unit) around cable and seat into rear of cable bracket assembly. 6. Slide front half of cable bracket assembly into slot until it contacts rear half of bracket. 7. Secure two halves of cable bracket assembly together using tie wrap (provided with unit). 8. Squeeze two strain-relief extensions tight against cable and secure using snap-lock clamp (provided with unit). "U" SHAPED BRACKET HALF OF CABLE BRACKET ASSEMBLY REAR 8 8 SNAP-LOCK CLAMP 6 HALF OF CABLE BRACKET ASSEMBLY FRONT 5 CABLE SEAL 7 TIE WRAP Page 5

63-460-32-03 STEP 3 INSTRUCTION FOR CIRCUIT WIRING (CONT) 9. Route customer wires to customer bridges through wiring troughs located on right-hand side of unit and front right-hand edge of RJ chassis. 0. Unplug assigned RJ plug.. Loosen two screws on assigned customer bridge. 2. Strip about /2 inch (2.7 mm) from ends of customer wires. 3. Wrap stripped green wire clockwise around TIP screw between two washers; then, wrap stripped red wire clockwise around RING screw between two washers. 4. Tighten screws, making sure stripped part of wires are not touching. 5. Plug RJ plug into jack. ID NUMBERS OF CUSTOMER BRIDGE WIRING RINGS (RING) SCREW CUSTOMER BRIDGE (TIP) SCREW RJ PLUG TOP VIEW Page 6

Issue 4, 63-460-32-03 STEP 4 REPLACEMENT OF RJ JACK ASSEMBLY AND CUSTOMER BRIDGE Replacement of Customer Bridge/RJ Jack Assembly:. Locate customer bridge to be replaced. 2. Unplug RJ plug from RJ jack. 3. Remove customer bridge/rj jack assembly by pressing in and out on front latch with flat screwdriver. 4. Install new customer bridge by first inserting back tab into slot, then pressing down on front latch. 5. Plug RJ plug into RJ jack. Replacement of RJ Jack Assembly With or Without Electronic Packages:. Locate RJ jack assembly to be replaced. 2. Unplug RJ plug from RJ jack assembly. 3. Remove RJ jack assembly by pressing in and out on front latch with flat screwdriver. 4. Pull out on disconnected RJ jack assembly until at least 6 inches (52 mm) of red and green wires become exposed and accessible. 5. Hold red and green wires in place so that they will not slip back into RJ chassis once they are cut off from old RJ jack assembly. 6. Cut off red and green wires at point closest to old RJ jack assembly. 7. Use Lucent Technologies 700-type splicing connector, or equivalent connector, to splice red and green wires to new RJ jack assembly. 8. Insert spliced wires back into RJ chassis. Then install new RJ jack assembly by first inserting back tab into slot, then pressing down on front latch. 9. Insert RJ plug into new RJ jack assembly. FRONT LATCH BACK TAB BACK TAB DANGER: Station protectors have the risk of electrical shock. Protectors are not to be used without the arrester assembly (protector) installed as per UL 497, paragraph 27.8. CUSTOMER BRIDGE FRONT LATCH AJ PLUG Page 7

63-460-32-03 Protector Modules Recommended for Use in all 289 type BEPs Protector Code Material ID Description Sneak Current Rating @ 25 Degree C DC Voltage Breakdown Impulse Sparkover Voltage 3BEW 04 40 47 Gas tubes N/A 265-425 V 200-800 V 4BEW 04 40 856 Gas tubes + Heat Coils Carry 350 Ma 265-425 V 200-800 V Operate in <20 seconds at 540 ma 3CS 05 54 756 Solid State, Balanced N/A 220-300 V 220-300 V 4CS 04 386 545 Solid State + Heat Coils, Carry 350 ma 220-300 V 220-300 V Balanced Operate in <20 seconds at 540 ma 7AAOT 08 5 97 Solid State, Bi Mod N/A 265-400 V 265-400 V 7ABOT 06 945 074 Solid State, Balanced N/A 265-400 V 265-400 V 7CBOT 06 945 538 Solid State, Balanced + Heat Carry 350 ma 265-400 V 265-400 V Coils Operate in <20 seconds at 540 ma 7AB6A 07 098 96 Solid State + MTU + Half N/A 265-400 V 265-400 V Ringer 7AB6B 07 670 028 Solid State + Half Ringer N/A 265-400 V 265-400 V 7AB6C 07 9 62 Solid State + MTU N/A 265-400 V 265-400 V NOTE: For the full range of protector modules available to you, contact your Lucent Technologies account representative. IMPORTANT: UL* PROTECTOR SHOULD BE INSTALLED IN ACCORDANACE WITH NEC, NCS, ANSI/NFPA 70 (ARTICLE 800 SECTION C). * Registered trademark of Underwriter Laboratories, Inc. Registered trademark of National Fire Protection Association. Page 8