Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Similar documents
Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Series 250 Pneumatic Control Valves Type and

Type 3271 Pneumatic Actuator. Actuator area: cm². Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Series 240 Type 3349/3379 Pneumatic Control Valve Type 3349 Aseptic Angle Valve

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions

Mounting and operating instructions EB Pneumatic Control Valve Type and Type Globe Valve Type 3522 ANSI Class 300

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Type 3379 Pneumatic Actuator. Mounting and Operating Instructions EB 8315 EN

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

T EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Strainers with flanged connections Type 2 N Type 2 NI. Type 2 N/2 NI Strainers. Mounting and Operating Instructions EB 1015 EN

Mounting and Operating Instructions

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

Valve Series V2001 Three-way Valve Type 3323

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)

Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175 and 750 cm². Type 3271 Type Mounting and Operating Instructions EB EN

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

T 8053 EN Type and Type Pneumatic Control Valves Type 3252 High-pressure Valve

Pressure Reducing Valve Type 2114/2415

Mounting and Operating Instructions EB 8392 EN. Series 3710 Type 3710 Reversing Amplifier

T EN Type 3349 Aseptic Angle Valve With USP-VI diaphragm

Pneumatic Control Valve Type and Type Micro-flow Valve Type 3510

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Series V2001 Valves Clean Tech Type 3321CT Globe Valve with pneumatic actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Series 250 Pneumatic Control Valve Type and Type High Pressure Valve Type 3252

Series 240 Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8256 EN. Type 3286 Steam Conditioning Valve

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Series 240 Pneumatic On-off Valve Type 3351

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Mounting and Operating Instructions EB 8052 EN. Type 3251 Valve

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Series 240 Pneumatic Control Valve Type and Type Three-way Valve Type 3244

Pneumatic Control Valve Assembly Type 3331/3278

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Application Pressure reducing valves for the food and pharmaceutical industries

Mounting and Operating Instructions EB 8252 EN. Type 3281 Steam Conditioning Valve

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Series 240 Types PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve

Data Sheet T EN

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Series 240 Pneumatic Control Valve Type DWA, -7 DWA, -9 DWA Globe Valve Type 3241 DWA

Mounting and operating instructions EB EN. Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

Mounting and operating instructions EB 8220 EN. Pneumatic Butterfly Valve Type 3335/AT and Type 3335/3278. Fig. 2 Type 3335/AT

Declaration of Conformity as per Directive 97/23/EC

Series 240 and 250 Valves with perforated plug

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Type 3273 Hand-operated Actuator Type 3273 Side-mounted Handwheel

ANSI version. The valve closes when the differential pressure rises

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Pneumatic Rotary Actuator Type 3278

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Series 2371 Pressure Regulators Excess pressure valves for the food and pharmaceutical industries

Maxifluss Rotary Plug Valves VETEC Types 73.3/M and 73.7/M

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Maxifluss Rotary Plug Valve. VETEC Type 72.1/R, Type 72.3/R and Type 72.4/R

Company Standard Mounting Instructions for Type Valves with Type AT Actuator

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Series 240 Electric Control Valve Type 3241/3274 Globe Valve Type 3241 Electric Control Valve Type 3244/3274 Three-way Valve Type 3244

USER INSTRUCTIONS. Kämmer SmallFlow / / SP Low and Micro Flow Valves. Installation Operation Maintenance

Maxifluss Rotary Plug Valves VETEC Types 72.3/R and 72.4/R

Pneumatic Butterfly Valve Type 3335 / AT

USER INSTRUCTIONS. Kämmer SmallFlow - Series / Low and Micro Flow Valves. Installation Operation Maintenance. Experience In Motion

Operating and installation instructions

Series 3331 Pneumatic Control Butterfly Valve Type 3331/BR 31a

Pneumatic Shut-off Butterfly Valve Type 3335/BR 31a

Transcription:

Type 3347-1 and Type 3347-7 Pneumatic Control Valves Type 3347-7, cast body with welding ends Type 3347-7, bar stock body with threaded connections Mounting and Operating Instructions EB 8097 EN Edition May 2016

Definition of signal words DANGER! Hazardous situations which, if not avoided, will result in death or serious injury WARNING! Hazardous situations which, if not avoided, could result in death or serious injury NOTICE Property damage message or malfunction Note: Additional information Tip: Recommended action 2 EB 8097 EN

Contents 1 General safety instructions...4 2 Design and principle of operation...6 3 Assembling valve and actuator...9 3.1 Assembly and adjustment...9 3.2 Option of preloading springs for "actuator stem extends"...10 3.3 Different rated travels of valve and actuator...10 4 Installation...11 4.1 Notes on installation...11 4.2 Signal pressure line...11 5 Operation...11 6 Maintenance...12 6.1 Replacing sealing parts and plug...12 7 Description of nameplates...14 8 Inquiries...15 EB 8097 EN 3

General safety instructions 1 General safety instructions The control valve must be mounted, started up, or serviced by fully trained and qualified personnel only; the accepted industry codes and practices are to be observed. Make sure employees or third persons are not exposed to any danger. All safety instructions and warnings given in these mounting and operating instructions, particularly those concerning installation, start-up and maintenance, must be strictly observed. The control valves comply with the requirements of the European Pressure Equipment Directive 97/23/EC. Valves with a CE marking have a declaration of conformity which includes information about the applied conformity assessment procedure. The declaration of conformity can be viewed and downloaded at http://www.samson.de. To ensure appropriate use, only use the valve in applications where the operating pressure and temperatures do not exceed the specifications used for sizing the valve at the ordering stage. The manufacturer does not assume any responsibility for damage caused by external forces or any other external factors. Any hazards that could be caused in the valve by the process medium, the operating pressure, the signal pressure or by moving parts are to be prevented by taking appropriate precautions. Proper shipping and storage are assumed. For installation and maintenance, make sure the relevant section of the pipeline is depressurized and, depending on the process medium, drained as well. Depending on the field of application, allow the valve to cool down or heat up to reach ambient temperature before starting any work on it. When working on the valve, make sure that the pneumatic air supply as well as the control signal are disconnected to prevent any hazards caused by moving parts. Be particularly careful if the actuator springs are preloaded. Such actuators are labeled correspondingly and can also be identified by three long bolts protruding from the bottom of the actuator. Before starting any work on the valve, relieve the compression from the preloaded springs. 4 EB 8097 EN

General safety instructions According to the ignition risk assessment performed in accordance with EN 13463-1:2009, section 5.2, the non-electrical control valves do not have their own potential ignition source even in the rare incident of an operating fault. As a result, they do not fall within the scope of Directive 2014/34/EU. ÎÎ For connection to the equipotential bonding system, observe the requirements specified in section 6.4 of EN 60079-14 (VDE 0165 Part 1). EB 8097 EN 5

Design and principle of operation 2 Design and principle of operation The Type 3347 Angle Valve can be combined with either a Type 3271 Pneumatic Actuator or a Type 3277 Pneumatic Actuator with integral positioner attachment. The standard valve body is designed for welding into pipelines. Other versions can be equipped with threaded or flanged ends, or clamp connections. The control valve is fitted with an easily detachable clamp connection between valve body and bonnet. The body free of dead space is suitable for CIP (Cleaning-In-Place). The control valves are mainly designed for use as control or on/off valves in the food industry. The medium flows through the valve in the direction indicated by the arrow. The plug (3) is moved by changing the signal pressure acting on the diaphragm of the actuator. The plug stem (6) with plug (3) and actuator stem (8.1) are connected by the stem connector (7) and sealed by a PTFE seals (5.1 and 5.3). In the special version with steam line connection, an additional spring-loaded PTFE ring packing (4.2) is used. In this case, the plug stem can be cleaned through the connection of a steam line. Fail-safe position Depending on how the compression springs (8.3) are arranged in the actuator, the valve has two different fail-safe positions: Actuator stem extends: when the signal pressure is reduced or the air supply fails, the springs move the actuator stem downward and close the valve. The valve opens when the signal pressure is increased enough to overcome the force exerted by the springs. Actuator stem retracts: when the signal pressure is reduced or the air supply fails, the springs move the actuator stem upward and open the valve. The valve closes when the signal pressure is increased enough to overcome the force exerted by the springs. Legend for Fig. 1 1 Valve body 1.1 Centering ring 1.2 Body gasket 1.3 Compensating ring 3 Plug 4.1 Spring (special version) 4.2 Packing (special version) 4.3 Washers (special version) 5 Valve bonnet 5.1 Stem seal 5.2 Body and stem seal 5.3 Wiper ring 5.4 Clamp 5.5 Travel indicator scale 6 Plug stem 6.1 Stem connector nut 6.2 Lock nut 7 Stem connector 8 Actuator 8.1 Actuator stem 8.2 Ring nut 8.3 Compression springs 9 Signal pressure connection 10 Compression-type fitting 6 EB 8097 EN

Design and principle of operation Type 3271 Actuator Type 3277 Actuator 7 5.5 5.3 8.3 8 8.2 8.1 6.1 6.2 6 8 8.1 5 8.2 9 5.4 5 5.2 1.3 3 1 Special version with steam line connection Version with cast body 6.2 6 10 5.3 4.2 5.1 5.4 1.2 1.1 4.3 4.1 4.3 3 1 Fig. 1: Sectional drawings EB 8097 EN 7

Design and principle of operation Compliance The Type 3347 Valve bears the EAC mark of conformity: 8 EB 8097 EN

Assembling valve and actuator 3 Assembling valve and actuator The basic pneumatic actuator can be replaced by a pneumatic actuator with additional handwheel or by an electric actuator. The standard pneumatic actuator can be replaced by a smaller or larger actuator for all nominal valve sizes. If the travel range of the actuator is larger than the travel of the valve, the springs in the actuator are preloaded by SAMSON so that the travel ranges match. 3.1 Assembly and adjustment Proceed as follows if the valve and actuator have not been assembled by SAMSON or if the actuator is to be replaced by an actuator of another type or size: 1. Loosen the lock nut (6.2) and stem connector nut (6.1) on the valve. Firmly press the plug together with the plug stem into the seat. Thread down the lock nut and stem connector nut. 2. Remove the clamps of the stem connector (7) and the ring nut (8.2) from the actuator (8). 3. Slide the ring nut over the plug stem. 4. Place the actuator onto the valve bonnet (5) and secure it with the ring nut (8.2). 5. Read the bench range (e.g. 0.2 to 1 bar) and the actuator's fail-safe action (e.g. "actuator stem extends") from the actuator's nameplate. The fail-safe action "actuator stem extends" or "actuator stem retracts" is marked by FA or FE on the Type 3271 Actuator, and by a corresponding symbol on the nameplate of the Type 3277 Actuator. The lower value corresponds to the lower bench range value to be adjusted, whereas the upper value corresponds the upper bench range value. NOTICE During assembly, make sure that the stem seal (5.1) is not damaged. The maximum possible actuator travel must not exceed the maximum permissible valve travel (see adhesive label on the yoke). 6. For actuators with "actuator stem extends" fail-safe action, apply a signal pressure that corresponds to the lower bench range value (e.g. 0.2 or 0.4 bar) to the connection on the bottom diaphragm chamber. For actuators with "actuator stem retracts" fail-safe action, apply a signal pressure that corresponds to the upper bench range value (e.g. 1 bar) to the connection on the top diaphragm chamber. 7. Screw on the stem connector nut (6.1) by hand until it touches the actuator stem (8.1). Turn it a further ¼ turn and secure this position with the lock nut (6.2) 8. Position clamps of the stem connector (7) and screw them tight. EB 8097 EN 9

Assembling valve and actuator 9. Align travel indicator scale (5.3) with the tip of the stem connector; for actuators with fail-safe action "actuator stem extends" align it with lower marking (valve closed) and for actuators with fail-safe action "actuator stem retracts" align it with top marking (valve open). Note on removing an actuator When removing an actuator with "stem extends" fail-safe action from a valve and especially an actuator with preloaded springs, apply a signal pressure that is slightly higher than the lower bench range value (see actuator nameplate) to the lower signal pressure connection to allow the ring nut (8) to be loosened. 3.2 Option of preloading springs for "actuator stem extends" To achieve a greater positioning force, the springs of the actuators can be preloaded by up to 25 % of their travel or their bench range. When a preload of, e.g. 0.1 bar, is desired for a bench range of 0.2 to 1 bar, the lower bench range value is shifted by 0.1 bar to 0.3 bar (0.1 bar correspond to a preload of 12.5 %). When adjusting the valve, set the lower bench range value to 0.3 bar. Write the new bench range with preloaded springs of 0.3 to 1.1 bar on the nameplate. 3.3 Different rated travels of valve and actuator WARNING! Actuators that have already been preloaded by the manufacturer without mounting the valve are labeled correspondingly. Additionally, they can be identified by three longer bolts with nuts protruding from the bottom diaphragm case. NOTICE Always use actuators with preloaded springs when the valve's rated travel is smaller than the rated travel of the actuator. 10 EB 8097 EN

Installation 4 Installation 4.1 Notes on installation The valve must be installed in the upright position with the actuator on top. NOTICE For valves with welding ends, after loosening the clamp (5.4), remove the entire valve construction from the valve body before welding it into the pipeline. 4.2 Signal pressure line Connect the signal pressure line for valves with actuator with fail-safe action "actuator stem extends" to the connection on the bottom diaphragm case, and for valves with actuator with fail-safe action "actuator stem retracts" to the connection on the top diaphragm case. In the Type 3277 Actuator, the lower signal pressure connection is located at the side of the yoke under the bottom diaphragm case. Make sure the valves are installed free of stress. Check to ensure the plug stem moves smoothly. Flush the pipeline thoroughly before installing the valve. If the valve bonnet is designed for connection to a steam line, connect the compression-type fittings to the steam supply line. NOTICE A pressure in the steam line connection (steam or sterile fluid) that is higher than the pressure in the valve itself may affect the process medium inside the valve due to it be mixed with the steam (or sterile fluid). Observe the relevant hygiene regulations. 5 Operation The actuator's direction of action can be reversed, if required. Refer to the mounting and operating instructions of the pneumatic actuator: u EB 8310 X for Type 3271 and Type 3277 EB 8097 EN 11

Maintenance 6 Maintenance If the valve leaks, the wiper (5.3), steam seal (5.1), or PTFE V-ring packing (4.2) (in the version with steam line connection) might be defective. If the valve does not close tightly, tight shutoff may be impaired by dirt stuck between the seat and plug or by damaged facings. We recommend removing the parts, cleaning them, and, if necessary, replacing them with new ones. 12 WARNING! Before performing any work on the control valve, make sure the relevant plant section has been depressurized and, depending on the process medium, drained as well. When used at high temperatures, allow the plant section to cool down to ambient temperature. As valves are not free of cavities, remember that residual process medium might still be contained in the valve. We recommend removing the valve from the pipeline or the entire valve construction when the valve is welded into the pipeline. Before starting any work on the valve body, disconnect the signal pressure and remove the signal pressure line as well as the actuator. During disassembly or assembly of the valve, make sure that the stem seal (5.1) is not damaged. The plug must not be moved beyond the valve travel. 6.1 Replacing sealing parts and plug NOTICE Before starting any work on the valve body, remove the actuator from the valve. 1. Apply a signal pressure that is higher than the lower bench range value to the actuator (see nameplate). 2. Remove the stem connector clamps (7) between the actuator stem and the plug stem and unscrew the ring nut (8.2). 3. Lift the actuator off the valve. 4. Remove nuts (6.1 and 6.2). 5. Remove the clamp (5.4). Remove the valve bonnet (5) together with plug (3) and centering ring (1.1). 6. Pull the plug out of the valve bonnet. Make sure that the stem seal (5.1) is not damaged. 7. Use a suitable tool to force out damaged parts, e.g. wiper (5.3) and stem seal (5.1). In version with steam line connection, also remove packing (4.2), washer (4.3), and spring (4.1). Clean the packing chamber. 8. Check the surface of the plug stem to ensure it is free of score marks and still has a mirror finish. Repolish the surface without any flaws to ensure the stem seal cannot get damaged. 9. Apply a suitable lubricant to the new parts and plug stem. EB 8097 EN

Maintenance Contact your nearest SAMSON subsidiary or the SAMSON After-sales Service department for information on suitable lubricants. 10. Place the stem seal initially in the opposite direction with the lip facing toward the thread end over the plug stem to stretch the lip of the stem seal slightly. Carefully pull the stem seal off again. 11. Slide a new centering ring (1.1) with gasket (1.2) over the plug stem (not necessary for the bar stock body version). 12. Carefully slide the stem seal, centering it, over the thread end of the plug stem. The stem seal must fit tightly, but slide easily over the plug stem. 13. Insert the plug stem with stem seal and centering ring (1.1) into the valve bonnet. 14. Push the wiper (5.3) over the plug stem into the valve bonnet. 15. Carefully place the valve bonnet onto the valve body. 16. Apply a suitable lubricant to the clamps (5.4) and the flanges of the valve bonnet and valve body. 17. Place the clamp in position and tighten the clamp screw. 18. Hit the clamp lightly with a plastic hammer and tighten the clamp screw again. Repeat this procedure several times until all parts fit properly to achieve a leaktight body. If the weight of the bonnet in the version with steam line connection is too light to put the clamp back on, slightly compress the packing springs over the bonnet beforehand. 19. Screw the lock nut (6.2) and stem connector nut (6.1) onto the plug stem (6). 20. Mount the actuator and adjust the upper and lower bench range values as described in section 3.1. EB 8097 EN 13

Description of nameplates 7 Description of nameplates SAMSON 3347 2 0062 1 3 Made in France 10 DN 4 5 P max 20 C = 6 T max = 7 K VS 8 Serial-No. 9 1 Type designation with revision index 2 Compliance with food industry requirements, if applicable 3 PED compliance, if applicable 4 Nominal size 5 Body material 6 Maximum pressure (bar or psi) 7 Maximum operating temperature ( C or F) 8 Valve flow coefficient according to DIN or ANSI: % = equal percentage or Lin = linear 9 Serial number 10 Year of manufacture ÎÎ Actuator nameplate: see the associated actuator documentation. 14 EB 8097 EN

Inquiries 8 Inquiries Please submit the following details: Type designation and serial number Version and nominal size of the valve Pressure and temperature of the process medium Flow rate in m³/h Bench range (spring range) of actuator, e.g. 0.2 to 1 bar Installation drawing Note: Refer to Data Sheet u T 8097 for dimensions and weights. EB 8097 EN 15

SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 3 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 Fax: +49 69 4009-1507 samson@samson.de www.samson.de EB 8097 EN 2016-10-24 English