Systemair Fire Dampers

Similar documents
Systemair Fire Dampers

PKI-C Cartridge Fire Dampers

PKIR3G, PKIS, PKIS3G and PKIS3GA

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

Fire Safety Products. Product Overview

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

SMOKE CONTROL DAMPERS

Rectangular fire damper TFER 30. pag. C-10

CFSD Series. Product Description

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

ESAS Smoke control damper

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

M A D E L. FOK-EIS-180 Fire dampers CE

7/S5 FIRE DAMPER FD40. v 2.9 (en)

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

For installation into ductwork

Fire dampers ETCE and ETCS TECHNICAL DATA

Motorized Fire Dampers

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

Smoke damper EKO-SRB1

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Rectangular smoke damper (remote controlled)

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

Fire damper FK120/FK90 TECHNICAL DATA

Fire/smoke damper EKO-SRBG1

TYPE EK-EU SMOKE CONTROL DAMPER

Fire/smoke damper EKO-JBG2

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

SMOKE DAMPER - CLASS F MODEL BMSD

Fire, Smoke, and Combination Fire Smoke Dampers

Introduction to Johnson Controls Dampers

CURTAIN TYPE FIRE DAMPER

TECHNICAL-OPERATIONAL DOCUMENTATION. FIRE SAFETY VALVES type V370 and RK370

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Fire Dampers Catalogue

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

Series HCD Airfoil Control Damper

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

products 22 º C Ventilation Air Conditioning Refrigeration Inside PROVIDED BY HEINEN & HOPMAN

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

series FSD-FLD Fire and smoke dampers UL Approval

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

Actionair Control and Shut Off Dampers

TECHNICAL-OPERATIONAL DOCUMENTATION RK370M FIRE SAFETY VALVES

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

Power consumption In operation At rest For wire sizing

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

CRE60 XF9499. Røgevakueringsspjæld Ø100-Ø630. AiR Ξ FORCE CRE60 XF9499 FORCE:

Fire damper. Type FKA-3.8. GB/en. Installation and operating manual. according to Declaration of Performance. DoP / FKA-3.

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Fire/combustion gas damper EKO-JBL

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Mechanical mixing box MBM

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Bevent Rasch BSK Fire /04/2017

MULTI-LEAF & SHUT-OFF DAMPERS Product Catalogue

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

series CEVH Smoke Evacuation Damper

CONSTANT AIR FLOW CONTROLLER

3. Dimensions and weights Placement and installation Pressure lost Material... 14

Fire/combustion gas damper EKO-JBG

Multileaf damper with actuator

Actuators for Fire and Smoke Protection Dampers

CR2. Circular fire damper C1-C 04/2010

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Power consumption In operation At rest For wire sizing

RETROFIT TERMINAL UNITS

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

VAV TERMINAL BOXES TYPE: BA BT

Actuators for Fire and Smoke Protection Dampers

British Standard institute-bs Valve Standards

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

Marine Fire and Gas Dampers

AL-Maraj Central A/C Systems Accessories Mfg Co.

Installation, Operation and Maintenance Manual

Actuators for Fire Protection Dampers

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Transcription:

Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class Dimensions Operation type Connection types Mounting flanges PK-I-R-EI- 60S, 90S and 120S ZV DV1 to DV9 - T - P Description As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. PKIR and PKIS fire dampers are intended to be embedded into fire partition walls or ceilings. Installation of these units is described in the Installation, Operation and Maintenance manual for rectangular and circular fire dampers. As standard, all dampers can be supplied with a manual actuator, optional accessories, e.g. microswitches, electromagnets, or a servo-driven actuator and communication control units. Ordering Codes for Rectangular FD: Fire resistance class Dimensions Operation type NOTES: E = Casing integrity I = Thermal insulation S = Smoke leakage PK-I-S-EI- 90S and 120S ZV DV1 to DV9 - T - Fire Dampers ith a Manual Actuator Fire damper automatically sets itself to closed position if the thermal fuse link gets ruptured or a signal is given to the electromagnet to release the damper blade from an open to closed position. After the closure, the damper blade is mechanically secured in the closed position and can only be opened manually. The fast blow fuse releases the link mechanism as soon as the air temperature in the duct system reaches 72 C and the damper blade closes within 10 seconds.. Servo-driven Fire Dampers Fire dampers can be equipped with a servo that closes the damper blade on demand of the Building Management System or based on a signal received from the thermoelectric fuse. Servo fitted fire dampers are standardly equipped with an electrothermal fuse which, when having reached or exce eded the ambient temperature of 72 C with a tolerance of ±1.5 C, activates the servo and closes the damper blade within 20 seconds.

2 / 7 Fire safety products Installation, Operation and Maintenance Fire dampers must be installed, operated and maintained according to the Installation, Operation and Maintenance manual Operating Conditions Dampers equipped with manual actuating mechanism and thermal fuse with a low melting alloy may be operated in a workplace where the operating temperatures fall in the range between -10 to 65 C. A damper equipped with a manual actuating mechanism and an electromagnet may be operated in a workplace where the temperature falls in the range of -10 to 40 C. Dampers equipped with a servo and a thermal fuse may be operated in a workplace with the ambient operating temperatures within the range between -10 to 65 C. The active fire-proof sealing must not be exposed to direct contact with water. The maximum air flow speed is 12 m/s with clean air without mechanic or chemical contamination with uniform flow, without condensation, ice coating and ice. The maximum allowable pressure difference in front and behind the closed blade is 1200 Pa. The device is not actuated until the ambient temperature reaches 65 C. In case of need of adjustment for higher temperatures in the working place it is advisable to consult such demands with the producer and indicate them in the purchase order accordingly. In terms of their construction, the dampers are designed for use with a horizontal, vertical or angled blade axis. Transportation, Storage and Operating conditions It is necessary to transport the dampers by such means of transport that provide a cover and secured on pallets. hen handling the dampers during transportation, the dampers must be protected against damage and weather conditions. The damper blades must be transported in the COSE position. It is recommended to store these products in a closed, dry, area where the temperature falls within the range of -10 C to +50 C. The temperature during storage, transportation and operation must not exceed 65 C! Material used and disposal The product contains steel, zinc, calcium-silicate board, graphite fire-proof laminate, polyurethane foam and ethylene-propylene dry rubber. These are processed in compliance with local regulations. The product does not contain any dangerous materials, with the exception of the solder s miligram quantity that contains Pb. arranty The manufacturer provides a 24-month warranty period starting on the date of expedition. Appendix Any demands regarding deviations from the above mentioned technical specifications and conditions shall be discussed with the manufacturer. The manufacturer reserves the right to perform any modifications of the product without prior notice, provided that such changes have no effect on the quality and performance of the product. The most recent state of our products is available at www.imos-systemair.sk Damper Codes and Types ZV; Basic model with manual crank and an actuating mechanism with spring return release driven by a fusible thermal link set to 72 C. DV1; ZV + closed position indication with a 24 V contact switch DV1-2; ZV + open and closed indication with 24 V contact switches DV2; ZV + closed position indication with a contact switch 230 V DV2-2; ZV + open and closed indication with 230 V contact switches DV3; ZV + 24 V AC electromagnetic re lease mechanism activated) DV4; ZV + 230 V AC electromagnetic release mechanism activated) DV5; ZV + 24 V AC electromagnetic release mechanism activated) plus 24 V switch indicating the damper s closed position DV5-2; ZV + 24 V AC electromagnetic release mechanism activated) plus 24 V switches indicating the damper s closed and open position DV6; ZV + 230 V AC electromagnetic release mechanism activated) plus 230 V switch indicating the damper s

Fire safety products 3 / 7 closed position DV6-2; ZV + 230 V AC electromagnetic release mechanism (release takes place when the electromagnet is activated) plus 230 V switches indicating the damper s closed and open position DV3B to DV6B-2; the same as DV3 to DV6-2 with electromagnet in interruption connection (release takes place by the interruption of the current in the electromagnet) Servo-operated Fire Dampers: Installation Accessories Set of 8 cover plates made from calcium-silicate boards (when using during installation please see the Installation, Operation and Maintenance manual - there are four front and four back cover plates). Ordering code for round cover plates: PRR-ND, ND = nominal diameter. Ordering code for rectangular cover plates: PRS--, = width, = hight DV7; spring return servo-operated fire dampers (230 V AC) without electro-thermal fuse, with auxiliary switches DV7-T; spring return servo-operated fire dampers (230 V AC) with electro-thermal fuse and auxiliary switches DV9; spring return servo-operated fire dampers (24 V) without electro-thermal fuse with auxiliary switches DV9-T; spring return servo-operated fire dampers (24 V) with electro-thermal fuse and auxiliary switches METO - PG20 adapter ordering code: MPA--, =width, =hight DV9-ST; spring return servo-operated fire dampers (24 V) without electro-thermal fuse, with auxiliary switches and Belimo BKN230-24 supply and communication unit. DV9-T-ST; spring return servo-operated fire dampers (24 V) with electro-thermal fuse, auxiliary switches and Belimo BKN230-24 supply and communication unit DV9-; spring return servo-operated fire dampers (24 V) with auxiliary switches and cables for the Belimo BKN230-24 supply and communication unit DV9-T-; spring return servo-operated fire dampers (24 V) complete with electro-thermal fuse, auxiliary switches and with the cables for the Belimo BKN230-24 supply and communication unit Meto-PG clutch - ordering code: MPC, item number: 15476 Connection Type P by mounting flanges If needed compensation of thermal dilatations use please our attenuators TV, TVK Ordering code for round attenuator: TVK-ND, ND=nominal diameter ( = 150 mm for all dimensions). Ordering code for rectangular attenuator: TV--, =width, =hight ( = 150 mm for all dimensions).

4 / 7 Fire safety products PKIR-EI30&E60S, -EI60S, -EI90S and -EI120S e offer a wide range of dampers and dimensions with fire resistance of 60, 90 and 120 minutes for circular ductworks. Circular fire dampers are certified according to the EN 15650, tested in accordance with the EN 1366-2 and classified according to the EN13501-3: Name Range of actuator types Dimension range (mm) Installation Fire resistivity PKIR EI30S&E60S DV7 to DV9-T- ø 100 to 630 PKIR EI60S ZV, DV1 to DV9-T- ø 100 to 630 PKIR EI90S ZV, DV1 to DV9-T- ø 100 to 1000 PKIR EI120S ZV, DV1 to DV9-T- ø 100 to 800* All circular fire dampers PKIR have CE certificate: 1396-CPD-0061 * The pressure drop is very high by smaller then ø200 Solid wall wet or dry Solid wall wet or dry Solid wall wet or dry Solid wall wet Flexible wall wet EI 30 (ve i o) S E 60 (ve ho i o) S EI 60 (ve ho i o) S EI 90 (ve ho i o) S EI 120 (ve ho i o) S EI 180 (ve i o) S DN 100 125 160 180 200 225 250 280 315 355 400 450 500 560 630 710 800 900 1000 450 500 540 600 * (mm) 37,5 87,5 * 5 27,5 52,5 77,5 107,5 142,5 182,5 227,5 277,5 327,5 Q (kg) 3,6 4 4,8 5,2 5,6 6,5 7 8,4 9,4 10,6 12,8 15,5 17,9 20,4 23,7 27,6 33,8 39,8 46,6 * overhang of the open blade including sealing and gap by opening Tab. 1: Dimensions and weights for manually operated circular fire dampers DN 100 125 160 180 200 225 250 280 315 355 400 450 500 560 630 710 800 900 1000 450 500 * (mm) 42,5 87,5 137,5 187,5 * 5 27,5 52,5 77,5 107,5 142,5 182,5 227,5 277,5 327,5 Q (kg) 3,6 4 4,8 5,2 5,6 6,5 7 8,4 9,4 10,6 12,8 15,5 19,4 21,9 25,2 29,1 35,3 41,3 48,1 * overhang of the open blade including sealing and gap by opening Tab. 2: Dimensions and weights for servo-operated circular fire dampers

Fire safety products 5 / 7 3 4 6 5 199 (EI60S) 203 (EI90S) 203 (EI120S) 1 6 4 3 5 199 (EI60S) 203 (EI90S) 203 (EI120S) 1 2 45 45 2 45 / 2 + 90 45 180 /2+105 180 + 110 + 121 Fig. 1: Manually operated circular fire damper construction for sizes ø 100 to 225 mm Fig. 2: Manually operated circular fire damper construction for sizes ø 250 to 1000 mm 9 7 6 45 2 45 199 (EI60S) 203 (EI90S) 203 (EI120S) 180 Fig. 3: Servo-operated circular fire damper construction / 2 + 80 + 110 1 8 Damper Parts Description: 1. Damper blade 2. Casing 3. Release mechanism 4. Electromagnet 5. Terminal switch 6. Inspection (control) opening 7. S e r v o 8. Thermo-electrical fuse 9. Supply and communication unit Belimo BKN230-24 PKIS-EI90S and EI120S e offer a wide range of dampers and dimensions with fire resistance of 90 and 120 minutes for rectangular ductworks. Rectangular fire dampers are certified according to the EN 15650, tested in accordance with the EN 1366-2 and classified according to the EN13501-3: Name Range of actuator types Dimension range (mm) Installation Fire resistivity PKIS EI90S PKIS EI120S ZV, DV1 to DV9-T- ZV, DV1 to DV9-T- All rectangular fire dampers PKIS have CE certificate: 1396-CPD-0062 * The pressure drop is very high by smaller then 200 200 all supporting constructions: Solid wall wet or dry 100 100 to 1000 1000 rigid wall / ceiling: 100 100 to 1600 1000 all supporting constructions: Solid wall we 100 100* to 1000 1000 Flexible wall wet rigid wall / ceiling: 100 100* to 1600 1000 EI 90 (ve ho i o) S EI 120 (ve ho i o) S

6 / 7 Fire safety products / (mm) 200 250 300 350 400 450 500 550 600 700 800 900 1000 1100 1200 1400 1500 1600 200 8,41 9,41 10,41 11,46 12,42 13,39 14,45 15,42 16,38 18,41 20,44 22,37 24,40 26,43 28,36 32,43 34,46 36,39 250 9,40 10,52 11,64 12,75 13,85 14,96 16,16 17,27 18,38 20,59 22,90 25,12 27,33 29,54 31,86 36,28 40,39 42,71 300 10,37 11,64 12,89 14,03 15,28 16,53 17,78 19,03 20,27 22,77 25,26 27,66 30,16 32,65 36,05 40,94 43,43 45,93 350 11,36 12,75 14,13 15,42 16,81 18,20 19,49 20,88 22,27 24,95 27,73 30,40 33,08 37,76 40,44 45,89 48,57 51,35 400 12,32 13,85 15,28 16,81 18,24 19,77 21,20 22,73 24,16 27,13 30,09 34,95 37,91 40,87 43,83 49,75 52,71 55,67 450 13,29 14,96 16,53 18,10 19,67 21,34 22,92 24,49 26,06 29,30 34,35 37,59 40,73 43,98 47,12 53,51 56,75 59,89 500 14,35 16,06 17,78 19,49 21,20 22,92 24,63 26,34 28,06 31,48 36,81 40,23 43,66 47,09 50,61 57,46 60,89 64,31 550 15,32 17,17 19,03 20,88 22,63 24,49 26,34 28,20 30,05 35,56 39,27 42,98 46,59 50,29 54,00 61,32 65,03 68,74 600 16,28 18,28 20,17 22,17 24,16 26,06 28,06 29,95 33,85 37,74 41,63 45,52 49,51 53,40 57,29 65,08 69,07 72,96 700 18,21 20,49 22,67 24,85 27,03 29,20 31,38 35,46 37,64 42,09 46,45 50,81 55,26 59,62 63,98 72,79 77,14 81,50 800 20,24 22,70 25,06 27,53 29,99 34,25 36,71 39,17 41,53 46,45 51,27 56,19 61,01 65,84 70,76 80,50 85,32 90,14 900 22,27 24,92 27,56 30,20 34,85 37,49 40,13 42,78 45,52 50,81 56,19 61,58 66,87 72,25 77,54 88,31 93,60 98,99 1000 24,20 27,13 30,06 32,98 37,71 40,63 43,56 46,49 49,41 55,26 61,01 66,87 72,72 78,47 84,32 95,93 101,78 107,63 Add 3 kg weight for the versions equipped with a servo Tab. 3: Dimensions and weights for the rectangular fire dampers EI90S / (mm) 200 250 300 350 400 450 500 550 600 700 800 900 1000 1100 1200 1400 1500 1600 200 8,83 9,88 10,94 12,04 13,06 14,07 15,19 16,21 17,23 19,36 21,50 23,53 25,67 27,81 29,84 34,11 36,25 38,29 250 9,87 11,05 12,22 13,38 14,54 15,70 16,96 18,12 19,28 21,59 24,01 26,33 28,65 30,97 33,39 38,02 42,24 44,66 300 10,90 12,22 13,52 14,72 16,02 17,32 18,62 19,92 21,22 23,82 26,43 28,93 31,53 34,13 37,63 42,73 45,33 47,94 350 11,94 13,38 14,82 16,16 17,60 19,05 20,39 21,83 23,27 26,06 28,94 31,72 34,51 39,29 42,07 47,74 50,53 53,41 400 12,96 14,54 16,02 17,60 19,09 20,67 22,15 23,74 25,22 28,29 31,35 36,32 39,39 42,45 45,52 51,65 54,72 57,78 450 13,97 15,70 17,32 18,95 20,57 22,30 23,92 25,54 27,17 30,52 35,67 39,02 42,26 45,61 48,86 55,46 58,81 62,06 500 15,09 16,86 18,62 20,39 22,15 23,92 25,69 27,45 29,22 32,75 38,18 41,71 45,24 48,77 52,41 59,47 63,00 66,53 550 16,11 18,02 19,92 21,83 23,64 25,54 27,45 29,36 31,27 36,88 40,69 44,51 48,22 52,04 55,85 63,38 67,19 71,01 600 17,13 19,18 21,12 23,17 25,22 27,17 29,22 31,17 35,11 39,11 43,11 47,10 51,20 55,20 59,19 67,19 71,28 75,28 700 19,16 21,49 23,72 25,96 28,19 30,42 32,65 36,78 39,01 43,57 48,03 52,50 57,06 61,52 65,98 75,01 79,47 83,93 800 21,30 23,81 26,23 28,74 31,25 35,57 38,08 40,59 43,01 48,03 52,96 57,99 62,92 67,84 72,87 82,82 87,75 92,68 900 23,43 26,13 28,83 31,52 36,22 38,92 41,61 44,31 47,10 52,50 57,99 63,48 68,87 74,37 79,76 90,74 96,13 101,63 1000 25,47 28,45 31,43 34,41 39,19 42,16 45,14 48,12 51,10 57,06 62,92 68,87 74,83 80,69 86,65 98,46 104,42 110,38 Add 3 kg weight for the versions equipped with a servo Tab. 4: Dimensions and weights for the rectangular fire dampers EI120S (mm) (mm) (mm) EI90/120S EI90S EI120S 300 22 12 400 72 62 500 112 600 22 172 162 800 272 262 1000 222 372 362 EI90S / (mm) 100 150 200 250 300 400 500 600 800 100 5,5 6,1 6,8 7,5 8,2 9,5 10,9 12,3 15,0 150 6,1 6,9 7,6 8,4 9,1 10,6 12,1 13,6 16,6 200 8,1 8,9 250 8,7 9,7 300 9,4 10,4 400 10,7 11,9 * overhang of the open blade including sealing and gap by opening Tab. 5: Blade overhang in fully open position Add 3 kg weight for the versions equipped with a servo Tab. 6: eights of low-profile rectangular fire dampers (Fig. 4 and 6)

Fire safety products 7 / 7 6 3 4 5 2 1 3 4 8 6 7 2 1 8 + 65 4 3 5 2 2 1 3 4 + 80 223 + 65 255 145 = 400 EI90S = 410 EI120S + 138 + 60 + 65 + 80 255 145 = 400 EI90S = 410 EI120S + 65 + 130 Fig. 4: Manually operated rectangular low profile fire damper construction for sizes in tab. 6 Fig. 6: Servo-operated rectangular low profile fire damper construction for sizes in tab. 6 9 6 8 7 2 2 1 7 255 145 = 400 EI90S = 410 EI120S + 80 + 120 255 145 = 400 EI90S = 410 EI120S + 80 + 140 Fig. 5: Manually operated rectangular fire damper construction for sizes in tab. 3, 4 Damper Parts Description: 1. Damper blade 2. Casing 3. Release mechanism 4. Electromagnet Fig. 7: Servo-operated rectangular fire damper construction for sizes in tab. 3, 4 5. Terminal switch 6. Inspection (control) opening 7. Servo 8. Thermo-electrical fuse 9. Supply and communication unit Belimo BKN230-24 Technical parameters Durability test Testing pressure Safe position - 50 cycles manual / 10000+100+100 cycles servo operated - without a change to the required attributes - 300 Pa - Closed Possible installations - Vertical/horizontal, solid/flexible wall, wet/dry (see classification tables on the pages 4 and 5) Airflow direction Side protected from fire - Optional - Optional 72 C as standard, other options based on requirements Closure - Manual - by springs after the thermal fuse melts - Servo operated - by springs in servo after the thermo-electrical fuse interruption Ambient temperature Repeated opening Closed/open indicator Suitability for ambience Inspection possibility Maintenance - In case of a 72 C thermal fuse, the temperature should be a maximum of 65 C, minimum -10 C - It is possible to open the device manually when it is cold - manual - 24 V DC / 230 V AC microswitches in versions DV1 to DV6-2 - servo operated microswitches included in servo versions DV7 to DV9-T- - Inside only - After opening of the inspection lid in round separat in rectangular 200 mm after removing activating mechanism - Not needed Pressure drops and noise levels are accessible in PKI selector S.