Pressure Relief Valve DB12 CE

Similar documents
Flow Control Valves and Flow Control Valves with reverse flow check DV/DRV

Pressure Compensated Flow Control Valves SRVR/SRVRP

Proportional Pressure Reducing Valve PDM08130

Check Valves, Size Spherical Poppet-type, Screw-in Design Series RKVE l/min, 350 bar (500 bar)

Flow control valve type SJ

3- and 4-Way Ball Valves KH3/KH4

Internal Gear Pumps Installation Manual

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Clamping and drive module

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Shut-off valve type AVT and AVM

PAHT pump PAHT X

Priority valve Type LPS

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

Vane pumps, direct controlled Type PV7...A

Service manual. Gear pumps - series T3S

SDUH350. Oil Filtration and Coolant Handling Specialists. Removes Contaminants. Extends Oil Life. Reduces Component Wear.

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Rexroth Hydraulics. Fixed displacement vane pumps Types PVV and PVQ RE /11.97

Releasable check valve type HRP

APP S 674 pumps APP S / APP S APP S

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

Applications. mineral oil according to DIN (other fluids on request) at 25 l/min (fully open) and 32 mm 2 /s: 155 bar

Vane pump, direct operated

VINCKE HYDRAULIC PUMPS

Industrial Valves Check Valve ZW RV / ZW RP - Modular

Industrial Valves Flow Control Valve ZW SDR - Modular

HYDAC (Three-Phase Current) Compact Power Units CO1

Check Valve, Size 04 16

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Subplates (AP) and multi-station subplates

HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

Releasable check valve type RH

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

RE / Central Hydraulics Valve LT43 for Tractors with Priority Function for Steering and Trailer Brake and Pilot Oil Valve.

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

Feed Pumps Direct Drive Series 1.1.

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

Process Inline Filter Medium / High Pressure PFM / PFH

Throttle valve type ED, throttle restrictor check valve type RD and RDF

Feed Pumps VP / VPB / VPBM

Axial Piston Fixed Displacement Pump KFA

HYDAC DC Compact Power Units DC1

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

6 to14/2 ways/positions bankable flow diverters flangeable

5.1 MEDIUM HEAVY DUTY SERIES SIZE 2

IGP /117 ED INTERNAL GEAR PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

External Gear Pumps Series F

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES

Operating Instructions

Priority valve LPS. Data sheet. Series 1 x

Hydraulic Valves. Experience plus ideas

Proportional Throttle Valves Series TDL

Directional Control Valves

6 to14/2 ways/positions bankable flow diverters flangeable

SBA Accumulator Safety Blocks

Compact hydraulic power unit Type BKA

Proportional Pressure Relief Valve Series RE*T

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

Proportional flow control valve 2-way versiontype 2FRE 6...RC

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

Service manual. Gear pumps - series QHD

Steering unit LAGZ. Data sheet. Series 2 x

6 to14/2 ways/positions bankable flow diverters flangeable

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Change-Over Pressure Filter DFDK

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

Central Hydraulics Valve for Tractors with Priority Function for Steering, Trailer Brake and Pilot Oil Valve

External gear pump Series G

Throttle valve and shut-off valve type CAV

Combination pumps Type BKP

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

Sectional Directional Control Valve RS 220

6/2 ways/positions flow diverters

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Suction Filter Pi 200

up to size 381 up to PN 0.5 bar up to T = 80 C Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TSE

Pressure controlled the 2-way directional valve type CNE

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048

Medium Pressure Filter Pi 3000

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

Steering unit LAGC. Data sheet

HYDAC Fluidtechnik: Industrial Valves FLOW CNTROL VALVE COMPENSATED PRESSURE VP-SR X.XXX.0/01.09 E / D E /08.

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium:

2.3 MEDIUM HEAVY DUTY SERIES

Pressure limitation and feed valve, pilot-operated Type MHDBN...Y

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

APP pumps APP / APP / APP / APP (W) / APP / APP / APP 21-43

Transcription:

Pressure Relief Valve DB12 CE up to 120 l/min Connection housings

1. DESCRIPTION 1.1. GENERAL According to DIN-ISO 1219, HYDAC pressure relief valves DB12-CE are valves for oil hydraulic systems to control pressure across the inlet by opening the outlet against a spring force. The valve is designed as a direct-operated pressure relief valve in seat valve construction. This provides very good opening/closing characteristics and enables user units to be sealed leakage-free. Further advantages of these valves are as follows: cavity dimensions to ISO 7789 low hysteresis and high stability ensure accurate pressure control optimum system adaptation owing to various pressure ranges limited setting range means that the spring cannot be blocked, thereby maintaining the pressure relief function the damping unit ensures that a stable operation is maintained over the whole capacity range and that the noise level is kept to a minimum small pressure increase at increased flow rate over the whole application range due to hydrodynamic lift support on the spring plate mechanical lift stop ensures operational safety even when pressure peaks cause an overload their compact design saves space when installing in connection housings, control blocks etc., especially in confined installation conditions. simple installation due to servicefriendly cartridge valve technology According to the Pressure Equipment Directive 97/23/EC, safety devices to prevent excess pressure (safety valves) form part of pressure vessel equipment. Pressure relief valves DB12 CE comply with the Pressure Equipment Directive 97/23/EC. The pressure relief valves are set, inspected and sealed by the factory-authorized inspector in accordance with the order specifications (pressure setting). A B C D E F Adjustment device with lift stop Valve body Spring Spring plate with hydrodynamic lift support Valve seat Closing cone with damping piston 1.2. FUNCTION The valve consists essentially of a valve body with built-in valve seat, a hardened and polished closing cone and the adjustment device for setting the initial spring tension. The spring applies this force to the closing cone and pushes it against the valve seat. On the opposite side of the closing cone, the system pressure acts via port 1 of the valve. If the hydraulic pressure force is below the pre-set spring tension, the valve is closed. If the hydraulic pressure force exceeds the pre-set spring tension, the closing cone is lifted off the valve seat and the operating fluid flows from pressure port 1 to tank port 2. This limits the pressure across port 1. To ensure that stable operation is maintained, the closing cone is rigidly connected to the damping piston which has to displace oil via an aperture with each movement of the closing cone. Each time, this produces an opposing damping force to the direction of movement. 1.3. APPLICATION HYDAC pressure relief valves DB12-CE are used as safety valves to limit pressure to the maximum permissible, according to Pressure Equipment Directive (PED) 97/23/EC. 1.4. NOTES Warning For correct operation, the application range and the ambient parameters must not be exceeded. Lead seal must not be broken. Pressure setting must not be altered. Plastic cap must not be damaged. Type code must remain visible and legible so that clear identification is possible. The type of valve must be clearly identifiable from the type code, see 2.1.2. Danger If the connections are incorrect, the safety function of the valve is disabled, see 2.1.1 and 3. When fitting the valves into control blocks and housings, the given torque values must be observed, see 3. Tank pressure (port 2) must be p 2 max = 0 bar. Dismantling the valve is not permitted. Only appropriate tools must be used to fit the valve. After a breakdown in the system (e.g. fire) the DB12 valve must be replaced for safety reasons. 2

2. TECHNICAL SPECIFICATIONS 2.1. GENERAL 2.1.1 Designation and symbol Pressure relief valve 2.1.2 Model code (also order example) Pressure relief valve Component approval mark DB12120A-010 - CE0034.ENISO4126.6L. Q.p Qmax Max. permissible flow rate of pump (see table for use with model code in l/min) p pressure setting in bar Standard models: Stock no. Model code (= order no.) 3108627 DB12120A-010-CE0034.ENISO4126.6L.110.210 3108635 DB12120A-010-CE0034.ENISO4126.6L.110.330 Please quote stock number when ordering. Non-standard models are custom-built (minimum order quantity 50 pieces). Delivery for non-standard models is longer and the price is higher. Table for use with model code (see also 2.2.7 Application range): p (bar) Q max (l/min) 30 65 35 65 40 72 50 80 60-80 80 95 90 100-105 95 110-150 110 160-250 110 260-350 110 360-400 110 2.1.3 Type of construction Cone-seat valve, direct-operated 2.1.4 Type of mounting Cartridge valve 2.1.5 Mounting position Optional 2.1.6 Weight 0.42 kg 2.1.7 Direction of flow From 1 to 2, pressure relief function From 2 to 1, shut-off leakage-free 2.1.8 Ambient temperature range min. 20 C max. +80 C 2.1.9 Materials Valve body: high tensile steel Closing element: hardened and polished steel, wear-resistant Seals: FPM and Teflon 3

2.2. HYDRAULIC DETAILS 2.2.1 Nominal pressure inlet (port 1): outlet (port 2): DB12-CE: up to 0 bar 2.2.2 Operating pressure ranges up to 150 bar up to 250 bar up to 350 bar for s, see 2.2.8 Pressure, dependent on flow rate 2.2.3 Pressure fluid Mineral oil to DIN 51524, part 1 and 2 2.2.4 Operating fluid temperature range min. 20 C max. +80 C 2.2.5 Viscosity range min. 10 mm²/s max. 380 mm²/s 2.2.6 Filtration Max. permissible contamination level of the operating fluid to ISO 4406 class 21/19/16 (NAS 1638 class 10). We therefore recommend a filter with a minimum retention rate of β 20 = 100. The fitting of filters and regular replacement of elements ensures correct functioning, reduces wear & tear and increases the service life. 2.2.7 Application range operating pressure p in bar permissible range Pressure range... 250 bar Pressure range... 350 bar flow rate in l/min Pressure range... 420 bar 2.2.8 Pressure, dependent on flow rate measured at ν = 28 mm 2 /s and t oil = 50 C Pressure range... 150 bar 4

3. DIMENSIONS DB12 4. NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. SW32 torque 50 +10 Nm CAVITY DIMENSIONS 12120A (TO ISO 7789) Geometry Cartridge form tools Tool Stock no. Countersink 175 002 / 162 128 Reamer 174 874 Tap 1002625 Plug gauge in preparation 5