Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Similar documents
Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-331 Combination Fire Smoke Dampers

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

VCD-23. Low Leakage CONTROL DAMPER

VCD-23 Low Leakage CONTROL DAMPER

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-20 3V CONTROL DAMPER

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model VCD-43 Extruded Airfoil Blade Control Damper

VCD-23. Flange Options. Size Limitations

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Thermal Isolation. Break

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

AMD-33 Air Measuring Station with VCD-33 Control Damper

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

HCD-230 Industrial Control Damper

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Fusible Link (replaceable) Horizontal Mount

Fusible Link (replaceable) Horizontal Mount

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

HVAC Control & Balancing Dampers

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Air Measuring Products AMD AMS IAQ

HVAC Control & Balancing Dampers

SD-1250 and SD-1600 Series Smoke Dampers

Motorized Fire Dampers

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

Installation, Operation and Maintenance Manual

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

Installation, Operation and Maintenance Manual

CFSD Series. Product Description

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Fire, Smoke, and Combination Fire Smoke Dampers

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

SMOKE DAMPER - CLASS F MODEL BMSD

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Fire Dampers Catalogue

FOR USE IN SOLUTION AIR HANDLING UNITS

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

BC Motorized Fire Smoke Dampers MSFD-GB-30C1-A MSFD-GB-30C1-A LISTED

ID-141x 12-Gauge Hat Channel Industrial Damper

Series HCD Airfoil Control Damper

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

LOW LEAKAGE VOLUME CONTROL DAMPER

Part # Installation,Operation and Maintenance Instructions

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

MULTI-BLADE FIRE DAMPERS

AIR DUCT ACCESSORIES

BD-1600 Balancing/Zone Control Damper

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

Introduction to Johnson Controls Dampers

LLOYD INDUSTRIES INC.

Blast Protection Damper

Installation, Operation, and Maintenance Instructions

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

MODEL 151B FIRE DAMPER

MULTI-BLADE FIRE DAMPERS

Blast Protection Damper

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Transcription:

R Model Application Model is a 304SS combination fire smoke damper with 3V style blades. The is qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa). This damper may be installed vertically (with blades running horizontal) or horizontally and is rated for airflow in either direction. Ratings UL 555 Fire Resistance Rating Fire Rating: 1 1 2 hours Dynamic Closure Rating: Actual ratings are size dependent Velocity: Up to 2,000 fpm (10.2 m/s) Pressure: Up to 6 in. wg (1.5 kpa) UL 555S Leakage Rating Leakage Class: I Operational Rating: Actual ratings are size dependent Velocity: Up to 2,000 fpm (10.2 m/s) Pressure: Up to 6 in. wg (1.5 kpa) Temperature: Up to 350 F (177 C) - depending upon the actuator Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL 555 1 1 2 Hour Fire Resistance Rating *W & H dimensions furnished approximately 1/4 in. (6mm) undersize. Add sleeve thickness for overall sleeved damper dimension. Right hand is shown. Left hand drive is available. Construction Standard Optional Frame Material 304SS - Frame Material Thickness 16 ga. (1.5mm) - Frame Type 5 in. x 1in. (127mm x 25mm) - hat channel Blade Material 304SS - Blade Material Thickness 16 ga. (1.5mm) - Blade Type 3V - Linkage 304SS out of airstream, concealed in jamb - Axle Bearings 304SS - Axle Material Plated steel - Blade Seals Silicone - Jamb Seals 304SS - Closure Device RRL RRL/OCI, TOR, PRV, or Fusible link Closure Temperature 165 F (74 C) 212 F (100 C), 250 F (121 C), 350 F (177 C) Features Frames are constructed with reinforced corners. Low profile head and sill are used on sizes less than 17 in. (432mm) high. Model meets the requirements for fire, smoke, and smoke dampers established by: National Fire Protection Association NFPA Standards 80, 90A, 92A, 92B, 101, & 105 International Building Codes (IBC) CSFM California State Fire Marshal Fire Damper Listing (#3225-0981:0103) Leakage (Smoke) Damper Listing (#3230-0981:0104) New York City (MEA listing #260-91-M) See complete marking on product. UL 555 & 555S Classification R13317 Maximum Size W & H Size Single Multiple Sections Section Horizontal Vertical 4 in. wg (1 kpa) Inches 8 x 6 24 x 30 or 22 x 36 48 x 30 88 x 72 mm 203 x 152 610 x 762 or 559 x 914 1219 x 762 2235 x 1829 6 in. wg (1.5 kpa) Inches 8 x 6 24 x 30 48 x 30 88 x 48 mm 203 x 152 610 x 762 1219 x 762 2235 x 1219 Installation instructions available at www.greenheck.com.

Options & Options for FSD-311V: OCI (Open Closed Indication switches) Electric or pneumatic actuators Transitions (R, C, O) POC retaining angles Test switches - GTS (Greenheck test switches) - Momentary - Toggle Sealed transitions and sleeves Security bars Smoke detectors H* W* RH Data LH This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.2 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. D 4 (W) (H) 3.14 Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. 6D Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system.

R Data AMCA Figure 5.2 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) 500 0.04 500 0.02 500 0.01 500 0.01 1000 0.14 1000 0.07 1000 0.04 1000 0.06 1500 0.31 1500 0.16 1500 0.09 1500 0.13 2000 0.55 2000 0.29 2000 0.16 2000 0.23 2500 0.86 2500 0.45 2500 0.25 2500 0.36 3000 1.24 3000 0.65 3000 0.36 3000 0.52 3500 1.69 3500 0.89 3500 0.49 3500 0.70 4000 2.20 4000 1.16 4000 0.64 4000 0.92 48 in. x 12 in. (1219mm x 305mm) 500 0.03 1000 0.10 1500 0.23 2000 0.41 2500 0.63 3000 0.91 3500 1.24 4000 1.62 AMCA Figure 5.3 6D 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) 500 0.02 500 0.01 500 0.01 500 0.01 1000 0.09 1000 0.04 1000 0.03 1000 0.04 1500 0.20 1500 0.09 1500 0.06 1500 0.10 2000 0.36 2000 0.16 2000 0.11 2000 0.17 2500 0.56 2500 0.25 2500 0.17 2500 0.27 3000 0.81 3000 0.35 3000 0.24 3000 0.39 3500 1.10 3500 0.48 3500 0.33 3500 0.53 4000 1.44 4000 0.63 4000 0.42 4000 0.70 48 in. x 12 in. (1219mm x 305mm) 500 0.02 1000 0.07 1500 0.16 2000 0.29 2500 0.45 3000 0.64 3500 0.88 4000 1.14 AMCA Figure 5.5 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) 500 0.06 500 0.03 500 0.03 500 0.03 1000 0.22 1000 0.14 1000 0.12 1000 0.13 1500 0.50 1500 0.31 1500 0.26 1500 0.30 2000 0.89 2000 0.54 2000 0.46 2000 0.53 2500 1.39 2500 0.85 2500 0.73 2500 0.83 3000 2.00 3000 1.22 3000 1.05 3000 1.19 3500 2.72 3500 1.66 3500 1.42 3500 1.62 4000 3.55 4000 2.17 4000 1.86 4000 2.11 48 in. x 12 in. (1219mm x 305mm) 500 0.04 1000 0.17 1500 0.38 2000 0.67 2500 1.04 3000 1.50 3500 2.05 4000 2.67 Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

Application Data Actuators and Accessories Space Envelopes Externally mounted actuators always require space outside of the damper sleeve. The S dimension illustrates the clearance required for various available actuators. On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the sleeve. B and T dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high, do not require these worst case clearances. If space availability above or below the damper sleeve is limited, each damper size should be individually evaluated. B* B* T* S Actuator Type/Model With With PiggyBack RRL, RRL/OCI, or TOR RRL, RRL/OCI, or TOR No Yes 120 Volt AC FSLF120 (-S) Belimo 3 1 2 in (89mm) 0 6 in. (152mm) NA FSNF120 (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) FSTF120 (-S) Belimo 3 1 2 in. (89mm) 0 6 in. (152mm) NA MS4104 Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS4109 Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS4120 Series Honeywell 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) GND-22X.1 Siemens 12 3 4 in. (324mm) 0 6 in. (152mm) NA 24 Volt AC FSAF24 (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) NA FSAF24-BAL (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) NA FSLF24 (-S) Belimo 3 1 2 in (89mm) 0 6 in. (152mm) NA FSNF24 (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) MS8104 Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS8109 Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS8120 Series Honeywell 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229m) GND-12X.1 Siemens 12 3 4 in. (324mm) 0 6 in. (152mm) NA 230 Volt AC FSLF230 (-S) Belimo 3 1 2 in (89mm) 0 6 in. (152mm) NA FSNF230 (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) MS4604 Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS4609 Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS4620 Series Honeywell 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) GND 321.1 Siemens 12 3 4 in. (324mm) 0 6 in. (152mm) NA Pneumatic (25 psi min.) 331-4551 Siemens 7 1 2 in. (191mm) 0 6 in. (152mm) NA 331-2976 Siemens 12 3 4 in. (324mm) 0 6 in. (152mm) NA 331-2856 Siemens 2 1 2 in. (64mm) 0 9 in. (229mm) NA * For dampers 18 in. (457mm) or more in height these dimensions are 0 in..

Application Data Damper Sleeve Dimensional Data The drawings below and corresponding table show the position of th e damper when mounted in a factory sleeve. The standard mounting locations provide enough space for the mounting of actuators, controls an allow space for installation of retaining angles and duct connections. The standard location of a damper mounted in a factory sleeve ( A dimension) is shown below. The damper can be positioned at other locations within a range of 6 in. (152mm) to 12 in. (305mm) for the A dimension. LH Right hand drive is shown. Left hand drive available upon request. 6 in. (152mm) RH Varies 3 3/4 in. (95mm) 5 3/8 in. (136.5mm) A Damper Location 5 in. (127mm) Sleeve/Sideplate Length 1 1/2 in. (38mm) max. in. (mm) "A" Dimension Standard Maximum All Dampers* 7 3 16 (183) 12 (305) When H is 11 in. (279mm) or less with OCI, RRL, or TOR 12 (305) 12 (305) *With the exception of dampers 10 in. high (254mm) or less. NOTE: Entire damper frame is not required to be installed within the wall. The damper blades, when closed should be contained within the wall. Damper Sizing Information Dampers larger than maximum single section size are supplied as a factory assembly of two or more sections of equal size. The following figures show maximum damper section size and assembly configurations for multi-section dampers. Single Section Double Section 30 in. (762mm) 30 in. (762mm) (1270mm) 24 in. (610mm) 24 in. (610mm) 48 in. (1219mm) 32 in. (813

Transitions & Specifications When a combination fire smoke damper is being used in conjunction with round and oval ductwork, the can be supplied in a factory sleeve with round or oval transitions on both ends of the sleeve. Dampers should be ordered to the duct dimensions. D* + 2 in. (51mm) +Ts W* + 2 in. (51mm)+T s W* + 2 in. (51mm)+T s D* + 2 in. (51mm)+T s 2 1/8 in. (54mm) H* + 2 in. (51mm)+T s 2 1/8 in. (54mm) H* H* + 2 in. (51mm)+T s 2 1/8 in. (54mm) H* 16 in. (406mm) D* 16 in. (406mm) W* 16 in. (406mm) W* TYPE R TYPE O TYPE C * These dimensions are furnished approximately 1 4 in. (6mm) undersize, except round and oval dimensions which are approximately 1 8 in. (3mm) undersize. Specifications Combination fire smoke dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall meet the requirements of NFPA 80, 90A, 92A, 92B, 101, and 105 and further shall be tested, rated and labeled in accordance with the latest edition of UL standards 555 and 555S. Damper shall have a UL 555 fire rating of 1 1 2 hours and be of low leakage design qualified to UL 555S. Each damper/actuator combination shall have a UL 555S elevated temperature rating of 250 F (121 C) minimum and shall be rated to operate at maximum design air flow at its installed location. Each damper shall be supplied with an appropriate actuator installed by the damper manufacturer at the time of damper fabrication. Damper actuator shall be (specified select one of the following) electric type for 120 or 24 volt operation or pneumatic type for 25 psi minimum (30 psi maximum) operation. Damper blades shall be 16 ga. (1.5mm) 304 stainless steel 3V type with three longitudinal grooves for reinforcement. Damper frame shall be 304 stainless steel formed into a structural hat channel shape with reinforced corners. Bearings shall be 304 stainless steel rotating in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tighter seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. Damper must be rated for mounting vertically or horizontally (with blades running horizontal) and be UL 555S rated for leakage and airflow in either direction through the damper. Each damper shall be supplied with 165 F (74 C) RRL. The damper manufacturer s submittal data shall certify all air performance pressure drop data is tested in accordance with the AMCA Certified Ratings Program for test figures 5.2, 5.3, and 5.5. Damper air performance data shall be developed in accordance with the latest edition of AMCA Standard 500-D. The basis of design is Greenheck model Copyright 2016 Greenheck Corporation Rev 8 November 2016