HYDRAULIC AND LUBE OIL FILTERS RFM Series

Similar documents
Low Pressure Filters

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

Low Pressure Filters

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

Low Pressure Filters

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

MEDIUM PRESSURE FILTERS

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

MEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

Series RFL In-Line Filter

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS Series HF2P

Series RFLD Duplex In-Line Filter

Duplex Pressure Filters

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS

NFH Low Pressure Filters

SPIN-ON FILTERS & ELEMENTS

Return Line Filter RFM with 4-Hole Mounting

NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports

Return Line Filter RFM with 4-Hole Mounting

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

FILTER ELEMENTS. Overview of Elements PN# / / FIL

Return Line Filter RF

Stainless Steel Pressure Filters Housings, Elements, Indicators & Sizing

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

Breathers. BF...3 & BF...4 Series INNOVATIVE FLUID POWER. ø D1 HEX. Specifications. Hydraulic Symbols. Model Code. Dimensions BF P 3 G 10 W 1.0 /.

Stainless Steel Pressure Filters

Return Line Filter RF

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

OFFLINE FILTRATION SYSTEMS

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Change-Over Inline Filter RFLD Weld Version

HPK04 Max Flow: 120 gpm (454 lpm)

HMK05/25 DURAMAX Spin-Ons

Return Line Filter HF4R up to 450 l/min, up to 10 bar

OVERVIEW OF RESERVOIR ACCESSORIES

Filters. HF4R Series. Service and Parts. Index. Inlet. Outlet. ø7 (ø177.8mm) Bolt Circle ø6.25 (ø158.8mm) ø0.44 (ø11.1mm) 4 Places Equally spaced

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

Change-Over Inline Filter RFLD Welded Version

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Be sure to order the correct number of elements: OLF 15 = 1, OLF 30 = 2, OLF 45 = 3, OLF 60 = 4

CUSTOM CLAMPS. Head Bolt Arrangements. Model Code B3-5 A1 B1 A1HB B1HB S1 HRSGBLPU 30 A1 373 ST

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

FPK04 Max Flow: 100 gpm (379 lpm)

Fluid Cooling Industrial COLW Series

Change-Over Pressure Filter DFDK

FPK02 In-Line Cartridge Filters

Pressure Filter DF...K P, DF...M P, Flange Mounted

RF4 Series. Return Line Filters

Filters. RFD Series. Change-Over Return Line Filter Service and Parts. 2. Element Replacement. 2.1 Element Removal

PT Series Tank Top Filters

Medium Pressure Filters

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

12CS/50CS Series. Coreless Spin-on Filters

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

Low & High Pressure ProGuard Filters

RFL Cast Series Service and Parts

Duplex Filter NFD (for NFD UHE (ultra-high efficiency), see NF Series) Service and Parts

10 Hydraulic Filters

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series. Medium Pressure Filters

10 Hydraulic Filters

12CS/50CS Series Coreless Medium Pressure Filters

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information

Return Line Filter RFM with 2-Hole Mounting

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-in filtration.

World Pressure Filters A new standard in 7,000 psi pressure filters

NF, NF UHE, NFD UHE & NF MMP with 2600 R element (for Ecomicronfit ( D) element version, see NF 1314/2614 Eco-Fit Series) Service and Parts

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

World Pressure Filters. A New Standard in 7,000 psi Pressure Filters

World Pressure Filters A New Standard in 7,000 psi Pressure Filters

MPD Series. Medium Pressure Duplex

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

MPD Series. Medium Pressure Duplex

Moduflow. ILP and RFP Low Pressure Filters. Series

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld

LPF Series Service and Parts

SPIN-ON FILTER - LOW PRESSURE LINE

MPD Series Medium Pressure Filters

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Medium Pressure Filters

CFU. Compact Filter Unit. hyprofiltration.com/cfu

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

12AT/50AT Series Spin-On Filters

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

12AT/50AT Series. Spin-On Filters. Global Filtration Technology

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar

IL8 Series. Medium Pressure Filters

FLOW CONTROL VALVES A5-1 PN# / / ACC

Transcription:

HYDRAULIC AND LUBE OIL FILTERS RFM Series Low Pressure In-Tank Return Line Filters psi up to gpm Technical Details Mounting Method 7/9///8 mounting holes - filter housing Features The compact and lightweight design make RFM filters especially suitable for mobile applications. RFM filters are constructed of polyamide plastic housing and lid. RFM 9///7 drop in replacement for Tank Topper filters. s 7-8 aluminum alloy is water tolerant - anodization is not required for water based fluids (HWBF). The filter bowl on models - 7 also serves as a contamination basket - removed to change element. Models,,, and 8 have filter elements equipped with separate, reusable contamination baskets. Cavities for clogging indicators are standard. s 7/9///8 available with - or -bolt tank flange. s 97 & added for increased flow capacities they also utilize separate bypass assemblies Applications Hydraulic Symbol RFM s 97 & coming in Agricultural Automotive Construction A T T A T /7/9///8//7/ ///8/97/ Port Connections 9/ 7//8 /7 / /8 97/ Direction of Flow Inlet / Outlet mounting holes - filter housing SAE-8 /.9 SAE- / SAE- /. Smooth Port SAE- / Open Bottom SAE- / NPT / SAE Flange, Code / NPT / SAE Flange, Code / G / BSPP SAE Straight Thread / NPT / NPT Threaded / NPT M / SAE Code Flange / NPT M Side inlet and bottom outlet. Mat. of Construc. Head Bowl Lid /9//7//8 /7 ///8 97/ Flow Capacity - gpm ( lpm) 7 - gpm (7 lpm) 9 - gpm (9 lpm) - gpm ( lpm) - gpm ( lpm) 8-9 gpm (8 lpm) - gpm ( lpm) Housing Pressure Rating Max. Oper. Press: Proof Pressure: Fatigue Pressure: Burst Pressure: Element Collapse Pressure Rating BN/HC (size 97 & only) BN/HC (size -8 only), W/HC ECO/N, BN/AM, P/HC, AM V Fluid Temperature Range Fluid Compatability Steel Steel 7-7 gpm (7 lpm) - 87 gpm ( lpm) - gpm ( lpm) - 7 gpm ( lpm) 8 - gpm (8 lpm) 97-8 gpm (9 lpm) - gpm ( lpm) Steel psi ( bar), psi (.9 bar) (s 97 & ) 8 psi ( bar) psi ( bar) @ million cycles - >8 psi ( bar) /8 psi (7 bar) 97/ Consult Factory psid ( bar) 9 psid ( bar) psid ( bar) psid ( bar) - to F (- to C) Compatible with all petroleum oils and synthetic fluids rated for use with Fluoroelastomer seals. Contact HYDAC for information on special housing and element constructions available for use with water glycols, oil/water emulsions, and HWBF. Indicator Trip Pressure P = psi (. bar) - % P = 9 psi ( bar) -% (standard) P = 7 psi ( bar) -% (optional) Bypass Valve Cracking Pressure P = psid ( bar) +% (standard - All s) P = 87 psid ( bar) +% (optional - s 97 & not available) P = psid (.7 bar) +% (s 97 & )

Model Code RFM BN/HC B F F D. X / - V - - L. Filter Type RFM = In-Tank Return Line Filter Element Media BN/HC = Betamicron (Low Collaspe) (not for sizes 9 & ) ECO/N = ECOmicron (Low Collaspe) (not for sizes /7) BN/AM = Betamicron Aquamicron MM = Mobilemicron (Low Collaspe) AM = Aquamicron W/HC = Wire Screen, 7, 9,,, 8,, 7,,,, 8, 97, Working Pressure B = psi ( bar) Y = psi (.9 bar) (97 & only) Optional Second Inlet Connection (omit) = no second port N = / NPT Threads (sz. 97 & only) F = / (SAE-) (sz. & only) V = x (SAE ) (sz. & 7 only) G = Threaded Port (sz. 97 & only) K = / SAE Flange (code ) (sz. & only) M = / SAE Flange (code ) (sz., 8, 97 & only) Inlet Connection/Port ( Inlet) C = / (SAE-) (sz., 9 & only) N = / NPT Threads (sz. 97 & only) D = (SAE-) (sz. 7, & 8 only) Z = Customer Specific E = / (SAE-) (sz. & 7 only) F = / (SAE-) (sz., 7,, & only) G = Threaded Port (sz. 97 & only) K = / SAE Flange (code ) (sz. & only) M = / SAE Flange (code ) (sz., 8, 97 & only) Filtration Rating (microns),,, = BNHC, ECO/N, = P/HC, = BN/AM, 7, 9 = W/HC = AM, = MM,,, = BN (sz. 97 & only),,, = BNHC (sz. only), = MM (sz. only) Type of Clogging Indicator A, B, BM, C, D, E, F, FD Type Number = no indicator, no ports - = clogging indicator positions (see chart) Modification Number (latest version always supplied) Inlet Port Configuration = SAE Straight Thread O-Ring Boss Ports (RFM -) = SAE Code Flange (sizes -8) Seals (omit) = Nitrile (NBR) (standard) V = Fluoroelastomer (FPM) Bypass (omit) = psid (standard) B.7 = psid (97 & only) B KB = = Bypass 87 psid ( bar) No Bypass not available with ECO/N Supplementary T = Filter Breather (RFM 7, 9,,, & 8 only) SOH = Anodized for high water based fluids, phosphate esters, and C = Outlet Check Valves (RFM, 97 & only) skydrol fluids (sz. 97 & only) DTxx = Down tube (xx length in inches - up to inches) L = bolt (sizes 9-8) DSxx = Dip stick (xx length in inches) M = Indicator with Deutsch Connector (FD indicator only) SOH = Modification of BN elements for phosphate esters L, L8, L, L = Lamp for D-type clogging indicator (LXX, XX = voltage) Replacement Element Model Code R BNHC / V, 7, 9,,, 8,, 7,,,, 8, 97, Filtration Rating (micron),,, = BNHC, ECO/N, = P/HC, = BN/AM, 7, 9 = W/HC = AM, = MM Element Media BNHC, ECO/N, P/HC, BN/AM, W/HC, AM, MM Supplementary Details (omit) = standard V = Fluoroelastomer (FPM) seals RFM s 97 & coming in Clogging Indicator Model Code VR B. X /. Indicator Prefix VR = Return Filters (sizes to 8) VMF = Mobile Filters (sizes to 7, 97 &) Trip Pressure. = psid (. bar) = 9 psid ( bar) = 7 psid ( bar) (optional) (N/A for 97 & ) Type of Indicator A = no indicator, plugged port B/BM = Visual pop-up (auto/manual reset) C = Electric switch D = Visual / electrical switch E = Visual pressure gauge F = Electric pressure switch FD = Electric pressure switch w/deutsch Connector Modification Number Supplementary Details M = Deutsch Connector (male) Seals (omit) = Nitrile (NBR) (standard) V = Fluoroelastomer (FPM) (For additional details and options, see Clogging Indicators section.) Model Codes Containing RED are non-stock items Minimum quantities may apply Contact HYDAC for information and availability

RFM s 97 & coming in Clogging Indicator Locations /-L....... Standard..X Clogging Indicator left back 9 to Inlet.X.X.X Clogging Indicator left back to Inlet.X 9 to Inlet.X 9 to Inlet RFM 9/. Plug RFM /9//-L..X.X. Standard. RFM /7. Plug. Plug.X Clogging Indicator left back.x.x.x Clogging Indicator right back. Standard. Plug RFM /. Standard..X Clogging Indicator left 9 to Inlet.X Clogging Indicator right 9 to Inlet.X Clogging Indicator on Top.. Standard..X Clogging Indicator left 9 to Inlet.X Clogging Indicator right 9 to Inlet.X Clogging Indicator on Top.

RFM s 97 & coming in Dimensions RFM 9/ RFM 7.7 (mm) RFM 8.98 (8mm).9 (mm) RFM 8.7 (9mm) RFM 9 7.87 (mm) RFM. (8mm) w/ oil separator. G /8 (8.mm) (G /8 adapter supplied with indicator) w/out oil separator.89 (7.mm) RFM 9/. (mm).9 (8mm) G /8 (G /8 adapter supplied with indicator) RFM 7.8 (mm) RFM 8. (mm).8 (8mm). (mm).8" (7mm) RFM 9.7 (7mm) RFM. (mm)." (mm). (mm) RFM 9/. (9mm).7 (mm) RFM 9/. (8.mm) RFM 8.7 (7mm) Hose Barb (mm) ø. (mm)." (7mm) /-L Clearence Required RFM 7.9 (mm) RFM 9. (mm) RFM8.8.9 (mm) (8mm) RFM9.7 (mm) RFM 7.8 (mm) RFM 8. (mm) RFM 8.7 (7mm) RFM 9. (9mm) /8 NPT Option ø.9 (ø7.mm) / - UN-B SAE- Port Tank ø.7 (ø78mm) ø.89 (ø7.mm). (mm) /-L Tank ø.7 (78mm) ø.7 (mm) ø.9 (mm). (9mm) ø.77 (ømm) 7 9 8 7 8 97 Weight (lbs.)...9....8 7.9.8 7....7. Dimensions shown are for general information and overall envelope size only. Weights listed are without element. For complete dimensions please contact HYDAC to request a certified print.

RFM s 97 & coming in RFM /-L 9.7 (8mm) ø. (ømm) places G /8 Places / - UNF-B SAE-8 ø.7 (ømm). (.9mm).8 (7.mm) 8. (9.mm).9 (9.9mm). (77mm).87 (7.mm). (77mm). (.mm) Hex ø.7 (ø78mm) Bolt Circle ø.7 (ø8.7mm) I.D. ø.9 (ø.8mm) O.D. RFM 9//-L.8 (mm). + ( + mm) RFM 9 9.8 (mm) RFM.9 (9mm). (79mm) RFM 9.7 (7mm) RFM 9.8 (mm) Tank ø. (ømm) ø. (ømm). -. (. -. mm). (mm) RFM /9//-L RFM ø. (mm) RFM 9/ ø. (8.mm) Tank RFM ø. (9.mm) RFM 9/ ø. (mm) RFM ø.7 (78mm) RFM 9/ ø. (9mm) 7 9 8 7 8 97 Weight (lbs.)...9....8 7.9.8 7....7. Dimensions shown are for general information and overall envelope size only. Weights listed are without element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions RFM /7 RFM /.78 (9mm) RFM.8 (mm) RFM 7.9 (mm) G /8 (G /8 adapter supplied with indicator).8 (mm) RFM s 97 & coming in Indicator Port G / RFM. (mm) RFM. (8mm). (mm).8 (98mm).88 (8mm) Clearance for Element Removal RFM.9 (mm) RFM 8. (mm) 7.87 (mm) Indicator Port G /".9 (mm). (mm) RFM 9.9 (mm) RFM 7. (8mm) RFM.77 (7mm) RFM 9.9 (mm) RFM.8 (mm) RFM 8. (8mm) open bottom ø.9 (mm) Threaded Outlet NPT ø.8 (mm) RFM /7////8 RFM /7. (.mm) RFM /.88 (mm).7 (7mm) Threaded Outlet G / ø. (mm) Dimensions RFM 97/. (8mm). (87mm) RFM 97 7.7 (mm) RFM. (9mm) RFM 97.8 (79mm) RFM. (mm). (8mm) ø. (ømm). (mm) thick BUNA N Gasket ø.88 (ø7mm) Hole in Tank for Installation RFM /7.7 (7mm) RFM /.97 (77mm) 8. (mm) RFM 97/ Bolt Circle / Tank Cutout.7 max. (7mm) ø. (ømm) on a 8.8 (mm) bolt circle mounting holes For Pipe/Straight For -Bolt Flange Std. Port Optional Dirt Alarm or Electric Switch RFM /7//. (mm). (.mm) Optional Port ø9. (ømm) ø.88 (ø7mm) for Tank ø8. (ømm) Bolt Circle ø. (ømm) x s equally spaced 7 9 8 7 8 97 Weight (lbs.)...9....8 7.9.8 7....7. Dimensions shown are for general information and overall envelope size only. Weights listed are without element. For complete dimensions please contact HYDAC to request a certified print.

Sizing Information Total pressure loss through the filter is as follows: Assembly P = Housing P + Element P Housing Curve: Pressure loss through housing is as follows: Actual Specific Gravity Housing P = Housing Curve P x.8 Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see sizing section on page 9) RFM /-L Housing 8...... 8 8 RFM 9/ & RFM 9//-L Housing 7 8 7 7 RFM s 97 & coming in... & /-L Housing 8...... RFM / 7 Housing 7 7 78 8... RFM / Housing...... 7 Housing...... 8 RFM 97 / Housing 8 8 w/check Valve w/o Check Valve.. Element K Factors Actual Viscosity (SUS) x Actual Specific Gravity P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x (From Tables Below) SUS.8...R...BNHC (Betamicron Low Collapse) µm µm µm µm.9 7.9.78...... 8.8..79.97...9. 7.8.9..9...9....9.....9 8.8... 97........ R MM µm µm 7.. 9..8..7..9 8.8.7.. 7...78.9....9 8.. R ECO/N (ECOmicron ) µm µm µm µm 9....7.7.9.77.89.7.9.. 8..7.7..8....8.9. 8.78... R W/HC (Wire Screen)...R...P/HC (Paper) R AM...R...BN/AM,, 7,, 9, µm, µm A µm µm 7. 7....8.77..8..8.7.7..9...9. 8. 8.7 8. All Element K Factors in psi / gpm. Copyright HYDAC TECHNOLOGY CORPORATION HYCON Division TECH DATA FIL-7