PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

Similar documents
Electrical... 5 Start-up... 6 Digital Pressure Switch Programming and Instructions... 7 Maintenance... 8 PRODUCT NUMBERING SYSTEM PHASE SERIES

PRODUCT NUMBERING SYSTEM SERIES PHASE. HD: Heavy Duty (15,000+ hour life) SD: Standard Duty (5,000+ hour life) LD: Light Duty (2,000+ hour life)

C T h e A d va n t a g e

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

6 Litre Oil-Less Air Compressor

Portable Electric/Gas Compressor Operating Instructions

6L Oil-less Air Compressor 53103

Portable Oil Free Silent Series Compressor Operating Instructions

ESE Series Cast Iron Sewage Pumps

See Warranty on page 6 for important information about commercial use of this product.

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Enclosed Electric Rotary Screw Compressor Installation Guide

Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

PARTS MANUAL FOR TWO STAGE AIR COMPRESSOR

OPERATING SERVICE MAINTENANCE MANUAL

Iron Horse Air Compressor part breakdown - IHD6160V1 Item Description IHD6160V1 IHD6160V1 Call for the Customer Service Department.

SUNC3000 / Item #40885

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

Installation and Operating Manual

SHALLOW WELL JET PUMP

AIR COMPRESSOR IDENTIFICATION

STAR STOP SHALLOW WELL JET PUMP

QUALITY MISTING PUMPS

Electric Reciprocating Compressor. Installation Guide

QUALITY MISTING PUMPS

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

HALLMARK INDUSTRIES INC

NECO Pumping Systems

User s Manual D-Series Blowers and Exhausters

END SUCTION CENTRIFUGAL PUMPS

Pump Owner s Manual. PLEASE! Read All Instructions Carefully Before Installing Pump

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

ADI-125/750 ADI-125/1500 ADI-125/2500

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

AUTO CHARGE D PUMP PLUS

AIR COMPRESSOR IDENTIFICATION

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Model C230 Pump Controller

StormPro BA Series Sump Pump

DC to AC Power Inverters

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

DC to AC Power Inverters

HEAVY DUTY ONBOARD AIR SYSTEM

Wash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010. Owner s Manual #

MOTORIZED FOLDING CAMPER WINCH

D-Series Blowers and Exhausters

AIR COMPRESSOR AC5161B AC5161BP. User Manual

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

MEDIUM DUTY ONBOARD AIR SYSTEM

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

Models & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø

User s Manual and Operating Instructions

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

M-3025CB-AV Fuel Pump

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

Air Storm Fans AS-57EBDBP AS-57EBDBP-HE

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

Read this entire manual before operation begins.

MODEL EGA200 OWNERS MANUAL

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Operating Instructions - Electric Pow'r-Riser Models

GARDEN HOSE UTILITY PUMP

WELDING FUME EXHAUSTERS & ARMS

StormPro BCV400 Sewage Ejector Pump

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

OWNERS MANUAL JANUARY 2007 ISO

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

LAWN SPRINKLER, IRRIGATION PUMP

Utility Distribution Systems Installation, Operation, and Maintenance Manual

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

110 Volt/12 Volt Portable Inflator

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

High Frequency SineWave Guardian TM

DISCLAIMER: SPECIFICATIONS:

1/4 ANGLE DIE GRINDER

MODEL EGA130 OWNERS MANUAL

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions

High Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570

Air Compressor. Owner s Manual

INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS

Atlas PV-9WP Addendum

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

PORTABLE AIR COMPRESSOR

Read this entire manual before operation begins.

MODEL EGA220 OWNERS MANUAL

Transcription:

TABLE OF CONTENTS Product Numbering System and Specifications... Safety... Receiving and Inspection... Installation... Electrical...6 Start-up...7 INTRODUCTION The compressor you have purchased is a combination of nearly 00 different components, all of which have been carefully designed, engineered, and assembled to ensure a long, dependable, trouble-free life. The product has been fully tested at the factory and has gone through quality-control inspection prior to shipping. Like any mechanical piece of equipment, it is necessary to fully understand the proper use of its operation and application. Misuse of this valuable and helpful air-power source may shorten its expected life as well as void the warranty of the entire unit. We ask you take the time to read this manual to ensure the dependable service you can expect from your C-Aire compressor. Failure to do so can cause serious injury and may void all warranties. Please take special notice of the safety precautions and safety information contained in this manual. Compressed air, like electricity, is a very helpful and necessary tool. However, compressed air can be extremely dangerous and harmful when it is not understood or is misused. PRODUCT NUMBERING SYSTEM Maintenance...7 Valves and Switches...8 Troubleshooting...8 Warranty...9 Parts Diagram...0 Air Compressor Basics... Back Cover S60 R LD P HD 75 65 35 500 750 900 300 700 SD 300 LD 60 6 MOUNTING OPTIONS B: Baseplate H: Horizontal Tank V: Vertical Tank (Only on S500 and larger) R: Riser Mount SERIES HD: Heavy Duty (5,000+ hour life) SD: Standard Duty (5,000+ hour life) LD: Light Duty (,000+ hour life) PHASE : Single Phase 3: Three Phase VOLTAGE 5 (Available on S500 and smaller) 30 (08/30v) 60 ADDITIONAL OPTION P: Prewired Power Cord S: Prewired Magnetic Starter U: 30-0psi Adjustable Pressure Switch D: Digital Pressure Switch (Also available in PU and SU) Not all combinations are possible. WHISPER QUIET - 60dB DESIGNED TO LAST YEARS BASED ON RUN TIME OF 30 MINUTES PER DAY SPECIFICATIONS: Must be used with an Air Pressure Maintenance Device. HP SYSTEM CAPACITY PRESSURE SWITCH CFM PUMP CYLINDERS VOLTS PHASE RUNNING AMPS BREAKER SIZE TANK SIZE OUTLET DIMENSIONS WEIGHT 0 PSI 60 GALLONS 0 PSI 50 GALLONS 0 PSI 00 GALLONS ON @55PSI, OFF @0PSI.35 @90PSI CYLINDER, OIL FREE CERAMIC COMPOSITE 5 7.5 5 AMP RECOMMENDED GALLON / NPT 36 x0.5 x7 LBS.

SAFETY DEFINITIONS DANGER: Indicates a hazardous situation that, if not avoided, will result in death or serious injury. WARNING: Indicates a hazardous situation that, if not avoided, could result in death or serious injury. CAUTION: Indicates a situation that will or could cause minor injury or property damage. GENERAL PRECAUTIONS Read the Owner s Manual before operating. DANGER: Do not use compressed air for breathing air applications. Beware of high voltage: disconnect lockout/tagout electric supply before servicing. Ground compressor per codes. WARNING: Beware of high-pressure air: do not bypass, modify, or remove safety/relief valves. Beware of hot surfaces: allow unit to cool before servicing. Do not operate with safety guards removed. CAUTION: Never operate the compressor near flammable liquids or vapors. Do not direct the air stream at body. Drain tank air every day to decrease risk of bursting. NOTE: Per UL 50:6.7 C-Aire recommends a maximum of 70% duty cycle for its compressors. RECEIVING AND INSPECTION Upon receipt, inspect the unit for damage and missing parts. If either is apparent, make notations on the delivery receipt, before signing the receipt. Ask the carrier how to file a claim for shipping damages. If concealed damage is discovered (after receiving the unit), notify the carrier within 5 days of receipt, in writing. INSTALLATION SELECTING A LOCATION: C-Aire compressors are to be installed and operated in a clean, dry, well-lighted, and well-ventilated area. Mounts to risers.5 -, concrete or cinder block walls or studs on a drywall. Provide at least 00 cubic feet of fresh air per hp. Ideal operating temperatures are between 3 F and 00 F. Avoid excessively humid areas, as moisture may form in the pump, producing sludge and causing moving parts to wear prematurely. NOTE: The dry pipe/sprinkler system compressor is to be installed in accordance with the Standard for Installation of Sprinkler Systems, NFPA 3. CAUTION: If temperatures consistently drop below 3 F, install the compressor in a heated area. (INSTALLATION CONTINUED ON NEXT PAGE)

CAUTION: Never operate the compressor in temperatures below 0 F or above 0 F. WARNING: A compressor should never be used in an area where toxic, corrosive, or volatile agents may be present. MOUNTING THE COMPRESSOR CAUTION: Remove the compressor from the shipping packaging before mounting. CAUTION: Do not mount riser mount unit horizontally. MOUNT TO RISER. Install mounting bracket on riser. Hang unit on mounting bracket 3. Bolt unit to mounting bracket. Install air filter assembly 3 (INSTALLATION CONTINUED ON NEXT PAGE)

MOUNT TO CONCRETE WALL C-Aire compressors are to be installed and operated in a clean, dry, well-lighted, and well-ventilated area.. Hammer drill holes for hollow wall anchor. Put hollow wall anchor into holes 3. Tap hollow wall anchor into cinder block with hammer. Attach mounting bracket to wall with bolt and washer into anchor 5. Locate hangers on back of unit 6. Hang unit onto the mounting bracket 7. Slip bolt through unit to mounting bracket 8. Tighten bolt to unit and mounting bracket 9. Install air filter assembly (INSTALLATION CONTINUED ON NEXT PAGE)

MOUNT TO CINDER BLOCK C-Aire compressors are to be installed and operated in a clean, dry, well-lighted, and well-ventilated area.. Hammer drill holes for hollow wall anchor. Put hollow wall anchor into holes 3. Tap hollow wall anchor into cinder block with hammer. Attach mounting bracket to wall with bolt and washer into anchor 5. Locate hangers on back of unit 6. Hang unit onto the mounting bracket 7. Slip bolt through unit to mounting bracket 8. Tighten bolt to unit and mounting bracket 9. Install air filter assembly 5 (INSTALLATION CONTINUED ON NEXT PAGE)

MOUNT TO DRYWALL C-Aire compressors are to be installed and operated in a clean, dry, well-lighted, and well-ventilated area.. Attach xs to studs in drywall. Attach mounting bracket to wall with bolt and washer into anchor 3. Hang unit onto the mounting bracket. Slip bolt through unit to mounting bracket 5. Tighten bolt to unit and mounting bracket 6. Install air filter assembly INLET AND DISCHARGE PIPING CAUTION: Do not operate unit without inlet-air filtration. If the air is dirty, pipe the filter to a source of clean air. Do not install piping with a diameter lower than that of the pump intake. CAUTION: Do not use PVC plastic in the discharge line. Use hand-welded or threaded steel or copper pipes and cast-iron fittings that are safe for the discharge pressure and temperature. ELECTRICAL WARNING: Compressor installation must be performed by a qualified electrician in accordance with the National Electrical Code (NEC) or the Canadian Electrical Code (CEC), the National Electrical Safety Code (NESC) OSHA code, and/or any local or state codes having precedence. Be sure of proper wire sizing and that the circuit breaker and the distance from the breaker is within suggested range. (ELECTRICAL CONTINUED ON NEXT PAGE) 6

Confirm your electrical-supply voltage matches what is required for the motor. WARNING: The compressor must be grounded. Grounding reduces the risk of electric shock. Certain C-Aire models are equipped with a cord that has a grounding wire with a grounding plug. The plug must be plugged into an outlet that is installed and grounded in accordance with all local codes and ordinances. WARNING: Improper installation of the grounding plug will result in a risk of electric shock. When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat-blade terminal. The insulated wire with a green outer surface and yellow stripes is the grounding wire. NOTE: The installation, electric motor, wiring, and all electrical controls must be in accordance with NFPA 70-996 National Electric Code, National Electric Safety Code, and state and local codes. WIRING DIAGRAM Failure to abide by the national, state, and local codes may result in physical harm and/or property damage. Wire to motor Wire to power source DANGER: High voltage may cause personal injury or death. Disconnect and lockout/tagout, per OSHA regulation 90.7, all electrical power supplies before opening the electrical enclosure or servicing. Wire to power source DANGER: Never assume a compressor is safe to work on if it is not operating. It could restart at any time. Always disconnect/lockout/tagout before servicing. CAUTION: Dry pipe sprinkler compressor must be wired to a reliable power source to be compliant with NFPA 3. PRESSURE SWITCH START UP NOTE: There is no need to break-in your compressor. It has been tested and run at the factory by qualified personnel. When operating the compressor for the first time, do the following:. Perform an inspection of the compressor to ensure there are no obstructions that might interfere with moving parts.. Release any remaining tank pressure by slowly opening the manual drain valve. 3. Connect the compressor to the power source (the compressor will start). MAINTENANCE WARNING: Before performing maintenance, release air pressure from the system and disconnect/lockout/tagout the main power supply. WEEKLY MAINTENANCE Drain moisture from your air compressor s tank WEEKLY! CAUTION: Open the drain valve slowly to release the moisture, as pressure in the tank can cause the moisture to expel at very high velocity. Check for any unusual noises, vibrations, or permanent leaks from the unloader valve. BIANNUAL MAINTENANCE TURN OFF POWER, and check and tighten all electrical connections. Change air-intake filter(s). Check to make sure all bolts are tight. 7

VALVES AND SWITCHES - Compressor will not operate - Knock occurs while compressor is loading - Tank does not hold pressure when compressor is turned off - Tank pressure builds up slowly - Fuses or breaker trip - Reset mechanism cuts out repeatedly. Fuses of proper size blow. TROUBLESHOOTING - No electrical power - Loose wire connections - Pressure switch not making contact - Overload/stripped - Connection rod bearings - Wrist pins, wrist pin bearings - Loose connecting rod nut - Suction and discharge valves - Check all fittings - Make sure Petcock is closed - Faulty Check Valve - Dirty air filter - Blown cylinder head gasket - Worn or broken suction/discharge valves - Air leaks - Wrong size fuses or breaker - Wrong size wire - Motor starting under load - Loose wires - Compressor is being overworked - Variable overload on compressor started needs adjusting - Motor overload - Malfunctioning or improperly adjusted pressure switch or pilot valve - High ambient temperature - Turn on power - Tighten connection - See pressure switch adjustment - Reset overload - Replace rod - Replace complete piston assembly - Tighten - Replace Valves - WARNING: Bleed tank. Disassemble Check Valve assembly, clean or replace faulty parts. - DANGER: Do not disassemble Check Valve with air in tank - Clean or replace filter element - Install new gasket - Install new valve - Tighten joints - Check fuse/breaker size - Check volts/amps - Make sure pump is unloading when compressor shuts off - Check electrical connections - Compressor should not run more than 6 out of 0 minutes on average - Call C-Aire - Shut down immediately to avoid damage - Adjust or replace - Provide ventilation - Overheating compressor - Poor ventilation - Relocate compressor - Internal pump problem - Have unit serviced - Water in air receiver - Condensation in the air receiver - Drain daily or install an Automatic Tank Drain 8

WARRANTY C-Aire Inc. warrants its compressors to be free from defects in material and workmanship subject to the following provisions: STANDARD WARRANTY DURATION: months from date of purchase. WHAT THE WARRANTY COVERS DURING THE WARRANTY DURATION: All components on the compressor except for those items listed in the section titled What is excluded from warranty coverage. WHAT IS EXCLUDED FROM THE WARRANTY COVERAGE: A) Air intake filters and compressor oil, which are maintenance items. B) Failure due to improper installation, including absence of mounting pads, and insufficient power. C) Oil leaks will be covered under warranty for a period of 60 days from purchase. D) Freight damaged items. (REJECT THE SHIPMENT or note damage on Bill of Lading) E) Any labor, freight or transportation charges that are not pre-approved by C-Aire. F) Labor charges incidental to the installation, electrical connections, repair, service, adjustment, removal, or replacement. G) Misuse or abuse. H) C-AIRE HAS NO OBLIGATION UNDER THESE WARRANTIES OR OTHERWISE (REGARDLESS OF THE FORM OF ACTION) FOR SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSS OF USE, LOST PROFITS, LOST INCOME, WHETHER SUFFERED BY THE BUYER OR A THIRD PARTY. HEAVY DUTY SERIES WARRANTY: C-Aire warrants its compressor pumps from the Heavy Duty Series (noted by the HD in its part number) to be free from defects in material and workmanship for a period of 36 months from the date of purchase. The 3 year warranty for HD units only covers the compressor pump. All other components are covered under the Standard Warranty Duration, which is months from date of purchase. C-AIRE S OBLIGATIONS: C-Aire will repair or replace, at C-Aire s option, defective parts, pay reasonable labor costs of replacing or repairing the defective part, and pay ground freight for the return of defective parts and shipment of the replacement part(s). ALL LABOR AND FREIGHT MUST BE PRE-APPROVED AND ARRANGED BY C-AIRE. PURCHASER S OBLIGATION: ) Properly install and start up the compressor using the checklist located at the back of this Owner s Manual. (Keep Installation Checklist for future reference.) ) Ensure the compressor is sized properly for the application. (the compressor should run no more than 7 out of 0 minutes on average.) 3) Maintain proof of purchase and Installation Checklist. WARRANTY CLAIMS: Please contact C-Aire at -800-76-7 or 65-6-30. Please have your completed Installation Checklist available. 9

ITEM NO. PART NO. RM 60R-000 RM 60R-000 3 RM 60R-0003 RM 60R-000 5 RM 60R-0005 6 RM 60R-0006 7 RM 60R-0007 8 RM 60R-0008 9 RM 60R-0009 0 RM 60R-000 RM 60R-00 RM 60R-00 3 RM 60R-003 RM 60R-00 5 RM 60R-005 6 RM 60R-006 7 RM 60R-007 8 RM 60R-008 9 RM 60R-009 0 RM 60R-000 RM 60R-00 RM 60R-00 3 RM 60R-003 RM 60R-00 5 RM 60R-005 6 RM 60R-006 7 RM 60R-007 8 RM 60R-008 9 RM 60R-009 30 RM 60R-0030 3 RM 60R-003 3 RM 60R-003 33 RM 60R-0033 3 RM 60R-003 35 RM 60R-0035 36 RM 60R-0036 37 RM 60R-0037 38 RM 60R-0038 39 RM 60R-0039 0 RM 60R-000 RM 60R-00 RM 60R-00 3 RM 60R-003 RM 60R-00 6 RM 60R-006 7 RM 60R-007 8 RM 60R-008 9 RM 60R-009 50 RM 60R-0050 5 RM 60R-005 5 RM 60R-005 53 RM 60R-0053 5 RM 60R-005 55 RM 60R-0055 56 RM 60R-0056 57 RM 60R-0057 58 RM 60R-0058 59 RM 60R-0059 60 RM 60R-0060 6 RM 60R-006 ITEM NO. 3 5 6 7 8 9 0 3 5 6 7 8 9 0 3 57 58 59 Description QTY Plastic Cover Filter Cover Filter Element Filter Base O Ring ø5 Gasket Pipe Hexagon Socket Screw Cylinder Head Gasket M*8 Screw Locking Block Valve Plate Valve Disc Valve Plate Washer M*8 Screw O Ring Cylinder M6*6 Screw 56 ITEM NO. 3 5 6 7 8 9 30 3 3 33 3 35 36 37 38 39 0 9 0 3 5 5 6 7 9 8 5 6 7 8 0 7 8 55 6 39 38 36 37 7 35 3 6 60 0 3 3 33 3 Air Compressor Exploded Parts Diagram S60R-LD-5P Description QTY ITEM NO. Description QTY ITEM NO. Description QTY Pressure Plate Piston Ring Connecting Rod Bearing Hexagon Socket Screw Crankcase Bushing Capacitor M*60 Stud ø Spring Washer Protecting Cover Self-tapping Screw Fan Blade ø Outside Spring Crank Throw Stator Rotor Bearing ø5 Outside Spring M*0 Screw 3 6 7 8 9 50 5 5 53 5 55 56 57 58 59 60 6 Capaciter Cover Power Cord Metal Hose Check Valve Strain Relief Copper Tube Pressure Switch Tank Drain Valve Hex Screw Washer Mounting Plate Nut Pressure Gauge Vibration Dampener Washer Nut Mounting Bracket Hex Screw Safety Valve 0 6 63 6 65 66 67 68 69 70 7 7 73 7 75 76 77 78 79 80 8 9 6 3 30 50 5 5 53 5 9 0

AIR COMPRESSOR BASICS Best practices: Tank mounted, direct driven compressors Tank mounted = reserve supply of air Air Source On 55psi air pressure- Off 0psi air pressure Air Pressure Maintenance Device System pressure 3-0psi Low Pressure High Pressure Dry Pipe Valve Water in system MODEL SERIAL # MFG. # Make a permanent record of the Model and Serial Number of your compressor by filling in the fields above. You ll save time and expense by including this reference identification on replacement part orders. 380 West st Street, Dresser, WI 5009 // 800.76.7//65.6.30//www.c-aireinc.com