WS-Series. Operating Instructions. Pulse DC End Area Coils. Drilco Style WS-Series Coils 1. E s t a b l i s h e d WS-14 WS-12 WS-10 WS-8

Similar documents
Operating Instructions August 2013

Established Operating Instructions. W-IC Series. Inspection Booth. Mobile. January, 2012 W-IC 1

Tube Sheet Pit Gauge

W-Series. Portable MPI Equipment Kits & Accesories. MPI Accessories continued... Distributed By. Yokes. Coils. Kits & Accessories

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

OPERATING INSTRUCTIONS

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

Simplifying Inspection MAGNETIC PARTICLE TESTING ACCESSORIES

Simplifying Inspection MAGNETIC PARTICLE TESTING ACCESSORIES

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

ADI-125/750 ADI-125/1500 ADI-125/2500

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

60 Watt Industrial LED Low Bay Light

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

OWNERS MANUAL JANUARY 2007 ISO

OPERATING INSTRUCTIONS BULLETIN MODEL DA750 March MAGNETIC INSPECTION UNIT

LESTRONIC II BATTERY CHARGER MODEL 19740

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

SPC-PANEL Simplex, Single Phase Pump Control Panel

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

FHC-1D user manual. Features

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Type NR oil switch installation and operation instructions

Patient Care Facility

FD Conveyor for FD 260 Tabber

Manual PN: Rev 01. Otterbine Barebo Inc. Fractional Series 50Hz Installation Manual

Level One Electric Vehicle Charging Station Wall Mount Product Guide

Effective June 1, 2013 This guide supersedes all previous versions

Air Curtain. Installation, Operating and Maintenance Instructions

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge

User s Manual and Operating Instructions

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

MIL-24/2600Q MIL-24/3200DQ

Rental Industry Safety Tester Safe Check 5s

Installation and Operations Manual

ARC 1850 LIST OF FIGURES

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

AUTO CHARGE D PUMP PLUS

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

Model LA 4300 Time Delay OFF Controller

ALUMAREEL. Electrical Cord Reel. Model EC6 100 Model EC Operational, Maintenance and Installation Manual

i400s Calibration Information Introduction

Installation Guide. Marine Filter SURT023M SURT024M

DC to AC Power Inverters

OPERATION MANUAL TWE-375 CAPACITOR DISCHARGE WELDER

DC to AC Power Inverters

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

INSTALLATION INSTRUCTIONS

A2P Single Phase Automatic Industrial Battery Charger

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

Model LA 4400 Time Delay OFF Controller

Pump Installation and Service Manual HRS Hydromatic Retractable System

1 AMP CURRENT SOURCE

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

MaxLite StaxMax LED Flood Lights

ESE Series Cast Iron Sewage Pumps

Electromagnetic Particle Brakes Model: PRB-H

Model LA 4100 Time Delay OFF Controller

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MECHANICAL GAUGES

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

AUTO CHARGE 1200 PUMP PLUS

OWNERS MANUAL IMPORTANT: READ OWNERS MANUAL CAREFULLY MODEL # SQUARE CAT XT OSCILLATING FLOOR MACHINE

INSTALLATION INSTRUCTIONS

POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

IMPORTANT RECEIVING INSTRUCTIONS:

WF-5110R True Sine Wave Inverter

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Electric Actuator Installation, Operation & Maintenance Manual

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

User s Manual and Operating Instructions

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR

Patient Care Facility

OWNERS MANUAL JANUARY 2007 ISO

Item no Smart AC 200 USB. User s Manual

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

WF-5100 Series True Sine Wave Inverters

INSTALLATION INSTRUCTIONS

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Transcription:

E s t a b l i s h e d 1 9 6 5 26509 Township Road 543 Phone: (780) 459-6720 Sturgeon County, Alberta Fax: (780) 459-7837 T8T 1M1 Canada E-Mail: info@westerninstruments.com Web: www.westerninstruments.com WS-14 March 2016 WS-12 WS-10 WS-8 WS-Series Operating Instructions Pulse DC End Area Coils Drilco Style WS-Series Coils 1

WS-Series Coils are operated from either 115 VAC or 230 VAC Power, which is either 50 or 60 Hertz. These Coils induce a Strong DC Magnetic Field, at the specified AC Voltage and Frequency Input, in the ferrous material being tested. The strong DC Pulse from WS-Series Coils induces the DC Field into a workpiece. These Coils conduct electricity in a circular fashion, which induces a Residual Longitudinal Magnetic field in a workpiece orientated axially through the Coil. This equipment should be utilized within the parameters set by the operational specifications within this guide. Description E s t a b l i s h e d 1 9 6 5 1. Coil Housing The Coil Housing is cast from a durable Urethane Rubber, which protects the Aluminum Wire Core. This Robust encapsulant is resistant to cracking and disbonding due to age or high/low temperatures, and is suitable for Dry or Wet Method media. Cast into the top inside portion of the Coil Housing are 2 non-ferrous bars, which are used to mount the Aluminum Control Panel Housing. Standard Coil sizes are 8 (203mm), 10 (254mm), 12 (305mm) or 14 (356mm) Inside Diameter and are selected depending on the size of the Work Piece to be inspected, however their operation and maintenance are identical. Control Panel Housing The Control Housing for WS-Series Coils, is used to mount the Solid State Electronic Controls, and is securely fastened to the molded coil housing with custom internal aluminum fasteners. The Control Housing is of a Welded Aluminum Construction, and fitted with an anodized aluminum Control Panel which is used for mounting the Coil s On off Switch and Energize Button. The entire Control Panel Housing assembly acts as a heat sink to dissipate heat from the electrical / electronic controls which increases the duty cycle. Operators should not be alarmed when the Control Panel or Housing becomes warm to the touch. Exposure to Bath (Carrier) fluids should be minimized, as they will cause failure to seals or other components. mounted to the Control Panel. 2. Duty Cycle The Duty Cycle (maximum duration) for periodic operation is set to avoid overheating of the Internal Aluminum Wire Coil and controls. Warm (or hot) Coil Wires have an increased resistance, and will reduce the overall Ampere Turn output of the Coil. WS-Series Models should not be activated, using the Energize Button for more than 5 seconds at a time. The activation time should be followed by an equal or longer cool down (or off) cycle. This 50% duty cycle is set to protect the Wire Coil and the Control Components from overheating. If the unit is used for extended periods of time, with short periods of activation the operator should be mindful of the temperature of the Coil and Control housing. If the operator has any concern about the actual or planned operation of the Coil, Western Instruments or the Distributor should be consulted. WS-Series Coils 2

3. Field Characteristics WS-Series Coils are considered a Full Wave DC device as they induce a strong Residual Magnetic Field in a Work Piece positioned though the Centerline of the Coil. A transverse Field may be introduced, if the Work Piece is short enough, by placing it perpendicular and inside the Coil s annulus. WP-Series Coils are designed to comply with specifications requiring Residual or Active Fields. Full Wave DC Coils induce a Residual Magnetic field that penetrates the work piece more deeply, however these residual fields are still sensitive to surface defects. When inspecting with a Residual Field, inspection media tends to adhere to the entire target area of the work piece, due to the reduced particle mobility. The operator may need to adjust the way the inspection media in put onto the workpiece. Media application at right angles to the field is beneficial. Furthermore the amount of inspection media placed on the surface of the workpiece may need to be adjusted. An excess may make an indication unclear and not enough media may not fully cause an indication to be made visible. The intensity of a DC Field, by it s nature, is fixed but the Coil does Pulse the field providing some stimulus for the particles to migrate to defects. 4. Operation With the Coil placed on the Work Piece, such as a threaded end of a pipe, or if the Work Piece is small it can be held within the inside of the coil. If held and if it is short enough to be rotated within the coil, a longitudinal or transverse field can be induced into the Work Piece. Application of particles, depending on the specification and skill of the operator, are applied while the Coil is Energized or after the field is set-up in the Work Piece. Active Field Inspection requires less skill by the operator in the application of the particles. With Residual Field Inspection there is no particle migration and greater skill and care must be taken in the application of the inspection media. The residual Field Induced by a WS-Series Coil can be measured at the end of workpiece with a simple Pocket Magnetometer. There is typically no Field escaping from a smooth surface so the end must be used. A Hall Effect Magnetometer can be placed at the root of the thread to measure escaping Flux. While a Hall Effect Magnetometer will measure such a magnetic Field from Tong Marks or Marks in the Slip area, but seasoned inspectors will use a Pie Gauge or Castrol Strips for prove up, but a simple Pocket Magnetometer at the end will indicate enough field 5. Maintenance: After extended use, WS-Series Coil Housing (Urethane Encapsulant) should be cleaned with a mild soap solution. The Control Housing and Control Panel should only we wiped down with a damp cloth of the same solution. The unit should be visually inspected regularly for any damage that could cause harm to the operator, or the material being inspected. Special attention should be paid to; the control switches/boots; and the power cord (cable) assembly. Any potential problems to these assemblies must be reported to the distributor or Western Instruments for instructions on corrective action. Other than routine maintenance, the operator can expect a long service life. Depending on the Industry or in-house specification utilized, and the type of service (field or shop) the Coil output should be Verified at regular intervals (yearly). Furthermore, during this verification (calibration) the field produced by the coil should be tested to ensure there is no reduction in the performance of the unit. However, the customer s Quality Manual or a Reference Specification may require more frequent Calibrations. The distributor or Western Instruments should be contacted for any specific instructions on maintenance, due to the specific environment of operation. Repairs, that need to be carried WS-Series Coils 3

out on the product, should be performed by a qualified service organization or Western Instruments. Throughout this manual, various internal control parts are referred to. Below is a guide to specific control components; Attention: Operators should not remove the Control Panel or loosen / tighten fasteners on Control Box Warning; The Capacitor stores enough Energy to cause injury Power Breaker Output Transistor Transistor Driver Board Rectifier Pulse Module The Control Panel should only be removed by qualified personnel. When reinstalling the Control Panel to the Control Housing, extra care must be taken to manage the wiring harness, so individual wires are not pinched (or shorted) between the Panel and Housing. Do not loosen any fasteners on the outside of the Control Housing. Qualified Personnel are those Technicians (or Engineers) who can do PCB Diagnosis and Board Level Repairs. It doesn t mean someone who is good at fixing things, or can use a soldering iron. The WS-Series Controls are complex and have a lot of stored energy WS-Series Controls exposed for Illistration Control Panel Energize Button Charging Power Stage AC Power Cord Strain Relief Control Housing Control Panel Fastener (4) Charging Controller Capacitor Wiring W-Series 230 Volt Models, are designated by a K placed after the Serial Number and the Model number (e.g. WC-6K), are shipped without an AC Power Plug as there is no international standardization. When installing an AC Power Plug onto the AWG 16-3 Power Cord (SOOW), the following is the identity of the 3 Color Coded Conductors; WS-Series Coils 4

Green Ground White - Neutral Black Live The power outlet (Mains) shall be fully grounded, with 3 terminals, one which is a Ground (Earth). Care must be taken to insure the proper installation of an AC Power Plug, and if there is any question, contact your distributor or Western Instruments. If an AC Plug in not installed before use, any warranty is void. Warranty: Western Instruments warrants all WS-Series Coils against defects in materials and workmanship for a period of 1 year from receipt by the end user. Consumable items are warranted against defects in materials and workmanship for 30 days from receipt by the end user. If Western Instruments receives notice of such defects during the warranty period, Western Instruments will either, at its option, repair, replace, or condemn products that prove to be defective. Any warranty is void if the unit has been modified in any way, mistreated, or if it has been repaired by an unqualified individual or agency. The end user agrees that any equipment s disposition, when returned for warranty work, is at the full discretion of Western Instruments as to whether a claim is under warranty or due to misuse. Western Instruments warranty shall overlook normal wear, however does not include operation outside the environmental specification of the product. Any warranty work is FOB Western Instruments, and any returned units shall include a written description, by the end user, of the fault. Western Instruments makes no other warranty, either expressed or implied, with respect to this product. Western Instruments specifically disclaims any liability arising from the use of this equipment. For the correct use of Western Instruments WS-Series Coils, refer to the Operating Instructions, furthermore we recommend formal training by qualified personnel. Western Instruments highly recommends the end user exercises all possible safety precautions, including the use of protective equipment, while operating this or other industrial equipment. WS-Series Coil Nomenclature Handle Power Breaker Power Switch Energize Button Front or End of Coil Centroid or Centerline Coil Thickness (Depth) Control Panel Control Housing Side of Coil Outside Diameter Inside Diameter Urethane Rubber Housing WS-Series Coils 5

Specifications: Model: WS-Series; 60 Hz WS-8, WS-10, WS -12, WS-14 50 Hz WS-8K, WS-10K, WS -12K, WS-14K Voltage: 115 VAC - 60 Hz 230 VAC - 50 Hz (Nominal). Current: 60 Hz Models WS-8, WS-10, WS-12, WS-14-15 Amps (Inrush Current) 50 Hz Models WS-8K, WS-10K, WS-12K, WS-14K - 15 Amps (Inrush Current). Capacity: 115kVAC x 60Hz WS-8 21,000 Amp Turns DC, 1,100 Gauss at Centroid. WS-10 18,000 Amp Turns DC, 750 Gauss at Centroid. WS-12 17,000 Amp Turns DC, 600 Gauss at Centroid. WS-14 16,000 Amp Turns DC, 450 Gauss at Centroid. 230VAC x 50Hz WS-8K 21,000 Amp Turns DC, 1125 Gauss at Centroid. WS-10K 18,000 Amp Turns DC, 800 Gauss at Centroid. WS-12K 17,000 Amp Turns DC, 620 Gauss at Centroid. WS-14K 16,000 Amp Turns DC, 470 Gauss at Centroid. ID Size: WS-8 8 (203mm), WS-10 10 (254mm), WS-12-12 (305mm), WS-14-14 (356mm). Depth: All Coils are 3 ⅝ (92mm) Deep. Weight: WS-8-14 pounds (6.4kg), WS-10-15 pounds (7.0kg), WS-12-17 pounds (7.7kg), WS-14-19 pounds (8.5kg). Established 1965 26509 Township Road 543 Phone: (780) 459-6720 Sturgeon Count, Alberta Fax: (780) 459-7837 T8T 1M1 Canada E-Mail: info@westerninstruments.com Web: www.westerninstruments.com WS-Series Coils 6