Filters. HF2P 79.4 Series Service and Parts. Index P Clogging. Indicator Port G 1/

Similar documents
Filters. HF3P Series Places 60 b c x d DP 4 Places Flange

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information

Filters. HF4R Series. Service and Parts. Index. Inlet. Outlet. ø7 (ø177.8mm) Bolt Circle ø6.25 (ø158.8mm) ø0.44 (ø11.1mm) 4 Places Equally spaced

Filters. DFP, DFPF Series. 2. Element Replacement. 2.1 Element Removal

HFM Series Service and Parts

Filters. RFD Series. Change-Over Return Line Filter Service and Parts. 2. Element Replacement. 2.1 Element Removal

MDF Series Service and Parts

LF & LFF Series Service and Parts

LPF Series Service and Parts

RKM Series Service and Parts

RFL Cast Series Service and Parts

DF, DFF & DFFX Series Service and Parts

RFN Series Service and Parts

Duplex Filter NFD (for NFD UHE (ultra-high efficiency), see NF Series) Service and Parts

NF, NF UHE, NFD UHE & NF MMP with 2600 R element (for Ecomicronfit ( D) element version, see NF 1314/2614 Eco-Fit Series) Service and Parts

DFDK Series Service and Parts

Selector Valve RV 713

Monoblock Directional Control Valve RM 230

Replacement Elements

Stainless Steel Pressure Filters Housings, Elements, Indicators & Sizing

Spare parts list Inline filter FLND switchable

Spare Parts List Filter NFD Change-Over Version

Stainless Steel Pressure Filters

Spare Parts List Return line filter RF

Spare Parts List Mobile Spin-On Filters MF/MFD. Flow rates up to 300 l/min Pressure range up to 8 bar Material: Aluminium / Sheet Steel

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

Spare parts list Return line filter RFM with 2-hole attachment

Spare Parts List Return Line Filter RFM with 4-hole attachment

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

HIGH PRESSURE FILTERS

Return Line Filter HF4R up to 450 l/min, up to 10 bar

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

MEDIUM PRESSURE FILTERS

HIGH PRESSURE FILTERS

Directional Control Valve. Formerly the RSM290 Series. Technical data. Pressures / Flows Max. operating pressure set per port:

HIGH PRESSURE FILTERS

Change-Over Pressure Filter DFDK

Pressure Filter DF...K P, DF...M P, Flange Mounted

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

HIGH PRESSURE FILTERS Series HF2P

Series RFL In-Line Filter

Series RFLD Duplex In-Line Filter

Duplex Pressure Filters

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Return Line Filter RF

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

NFH Low Pressure Filters

World Pressure Filters. A New Standard in 7,000 psi Pressure Filters

World Pressure Filters A New Standard in 7,000 psi Pressure Filters

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Change-Over Inline Filter RFLD Welded Version

World Pressure Filters A new standard in 7,000 psi pressure filters

Change-Over Inline Filter RFLD Weld Version

15/40/80CN Series Coreless Medium Pressure Filters

EN / Modern Duplex Filters for Large Engines

Return Line Filter RF

NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports

Process Inline Filter Medium / High Pressure PFM / PFH

MultiRheo Filter MRF 1/2/3/4/5/6/7

PT Series Tank Top Filters

FILTER ELEMENTS. Overview of Elements PN# / / FIL

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

HYDRAULIC AND LUBE OIL FILTERS RFM Series

Return line and Suction Boost Filter RKM

Return Line Filter RFM with 4-Hole Mounting

12CS/50CS Series. Coreless Spin-on Filters

Return Line Filter RFM with 4-Hole Mounting

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Electrohydraulic Drive System EHC-A

Process screen basket filter PRFS

15P/30P Series High Pressure Filters

12CS/50CS Series Coreless Medium Pressure Filters

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Automatic Back-Flushing Filter for Process Technology AutoFilt RF3.

HYDAC Quality for Pall Housings: Ecomicron 2-fit.

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

MultiRheo Filter MRF 1/2/3/4/5/6/7

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

2/2-Way Pressure Relief Valve CX DBV (Right-Angle Design)

Components and Systems for the Automotive Industry

Oil Solutions. GA/BGAH Series Medium Pressure Filters. Global Filtration Technology. Filtration.

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

RF4 Series. Return Line Filters

Change-Over Inline Filter AFLD to API 614

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S..

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018

15/40/80CN Series. Medium Pressure Filters

Process Inline Filter Protective filter PLF2-9HF

Low Pressure Filters

Transcription:

2.05 52 3.39 86 0.24 6 0.84 21.4 P Clogging Filters Indicator Port G 1/2 4.02 102 3.13 HF2P 79.4 Series Service and Parts INLET OUTLET This symbol is followed 3.86 by user tips and particularly useful 98 information. Index 1.00 1. General 25.4 1.4 Tools Required for Maintenance 1.5 Torque Requirements 2. Maintenance 3. Changing the Element [8.43] 4. Spare Parts List HF2P-04 214 [12.09] 5. Replacement Element Model Code HF2P-08 307 This pressure unit is for use with hydraulic power or lube systems only. All repair, maintenance, installation and commissioning work must be carried out by trained personnel. Operate this pressure unit in accordance with hydraulic power or lube system operating instructions. Ensure the pressure unit Mounting is sufficiently Holes cool before handling. This pressure unit is suitable [0.27] for use with hydraulic or lubricating fluids only. 6.75 It is the responsibility of the Thru operator to comply with local water regulations. 2 Places CAUTION! This symbol denotes safety precautions, the nonobservance of which can endanger persons and the environment. Filter bowl may be full of hot hydraulic fluid. Collect oil in a suitable container and dispose of properly. Observe proper venting procedures to avoid the formation of air pockets. Caution: Pressurized unit. Purge system pressure before performing any work on the pressure unit. Under no circumstances must any modifications (welding, drilling, or opening by force ) be carried out on the pressure unit. Any modifications will void the warranty. Statutory accident prevention regulations, safety regulations and safety data sheets for fluids must be observed. When working on or near hydraulic systems, avoid exposure to open flames and spark generating equipment. Do not smoke near equipment. Comply with all regulations with regard to the disposal of used oil and waste. Wear proper protective clothing and guards to avoid injury or scalding due to high pressure or high temperature oli. Filter housing must be grounded. Disconnect all electrical power to the system and other electrical components, prior to working on filter clogging indicators. NOTE: All details subject to technical modification

FILTER MAINTENANCE 1. General 1.1 Commitment to Quality HYDAC demonstrates its commitment to quality through the implementation of an ISO 9001: 2008 program, which encompasses not only product design and manufacturing but service and delivery as well. 1.2. Installation Before installing the filter in the system, check that the operating pressure of the system does not exceed the maximum allowable operating pressure of the filter. Observe type code label on the filter. Important: When operating filters without bypass valve above 20 bar (290 psid), high collaspe BH/HC type filter elements must be used to ensure safe operation. 1.3. Commissioning Unscrew bowl and check that the correct filter element is installed. Screw in bowl again fully (metal to metal contact) and then unscrew by one quarter-turn (the sealing effect will not be improved by overtightening.) Switch on hydraulic system and check filter for leakage. Vent filter at an appropriate point in the system. 1.4. Tools Required for Maintenance Size Wrench size for filter bowl Wrench size for clogging indicator HF2P 24 mm 27 mm 1.5. Torque Values Type VD-clog ind Oil Drain Plug Bowl/Lid or end cover 2. Maintenance 2.1. General Max. Torque Nm[ft-lb] 100 [74] 50 [37] (A, LE, LZ) N/A Do not Torque See 1.3 and 3.2 This section describes periodic maintenance requirements. Periodic and thorough maintenance will ensure operator safety and the life of the filter. 2.2. Maintenance Procedures Only high quality spare parts meeting the technical requirements specified by the manufacturer should be used, quality is always guaranteed with HYDAC original spare parts. Keep tools, working area and equipment clean. After disassembling the filter, clean all parts and check for damage or wear. Replace parts as required. When changing filter elements, a high level of cleanliness must be observed. Ultrasonic cleaning is used for cleaning Metal Fiber (V) and Wire Screen (W/HC) elements. To ensure optimum performance, HYDAC recommends replacing filter elements every 6 months or upon indication, whichever occurs first. HYDAC recommends installing the filter with a clogging indicator (visual and/or electric or electronic) to monitor for excessive filter element pressure drop. If the clogging indicator trips, immediately change or clean the filter element. (Only wire mesh and metal fiber elements can be cleaned). If no clogging indicator is installed, HYDAC recommends changing elements at specified intervals (depends on filter sizing and conditions). Higher dynamic loads across the element might necessitate shorter intervals between changes. Shorter intervals can also be expected during commissioning, repairs, oil changes, etc. of the hydraulic system. 3. Element Replacement 3.1. Element Removal 1. Switch off hydraulic system and release filter pressure. 2. Remove oil drain plug (if present). Drain oil into container. 3. One-piece bowl: Unscrew filter bowl (drain fluid into a suitable container and clean or dispose of it in accordance with environmental regulations). Two-piece bowl: Unscrew lid (drain fluid into a suitable container and clean or dispose of it in accordance with environmental regulations) and remove threaded pin. Top removable: Unscrew the lid. 4. Remove filter element from nozzle in filter head (check surface of element for contamination residue and larger particles; these can indicate damage to components). 5. Replace or clean filter element (only W/HC (wire screen) and V (metal fiber) elements can be cleaned). 4. Clean filter bowl and filter head; particular attention must be given to the threads. 5. Examine filter, especially sealing surfaces, for mechanical damage. 6. Check O-rings and replace if necessary. 3.2. Element Installation 1. Lubricate sealing surfaces and thread on the filter head and bowl, and the seals with clean operating fluid. 2. When installing a new element, verify that the designation corresponds to that of the old element. 3. Place filter element carefully onto the element location nozzle in the filter head. 4. Apply silver grade anti-seize (per Mil-PRF-907E) to threads. Screw in bowl fully (metal to metal contact) then unscrew by one quarterturn. 5. Switch on hydraulic system and vent filter at an appropriate point in the system. 6. Check filter for leakage. 2.3. Interval Between Changing Elements Note: Contamination or incomplete pressure release on disassembly can lead to seizing of the bowl thread. Filter elements which cannot be cleaned must be disposed of in accordance with environmental regulations. 2

FILTER MAINTENANCE 4. Spare Parts 4.1. HF2P - 04/08 2.3 2.1 2.2 1.2 / 4.1 4.2 4.3 1.1 3.0 Item Consists of Designation HF2P-versions 1.0 & 1.1 HF2P-version 1.2 1. Filter element See point 5 Replacement elements 1.1 Filter element On request 2. 1.2 O-ring (1.07.0XXDYYBN element) O-ring (1.07.XXDYYBH element) Clogging indicator or indicator plug VD 0 A.1 VD 0 A.1 /-V 24.99 x 3.53 (AS568A-214) 25.07 x 2.62 (AS568A-120) See Filter Clogging Indicator brochure 00305932 00305931 2.1 Indicator plug VD... 2.2 Profile seal ring VD... (AS586A-908) 2.3 O-ring 16.36 x 2.21 (AS568A-014) 15 x 1.5 3. BOWL For Bowl Assembly - consult factory 4. SEAL KIT HF4P 2202425 2202428 Seal Kit HF2P /-V 2202426 2202429 4.1 O-ring (element) See 1.2 above 4.2 O-ring (bowl) 53.65 x 2.62 67.95 x 2.62 (AS586A-138) 4.3 Back-up ring (bowl) 54.4 x 58.8 x 1.3 71.60 X 67.20 X 1.40 Other spare parts available on request Bold items can be ordered. -O-Ring durometer can range from 70-80Sh. EPR Seal Kits available on request. -Bowl assembly kits on request - kits include complete bowl with seals, and plug (if present). 3

FILTER MAINTENANCE 4.2. HF2P - 04/08 Sub-plate 4.4 2.3 2.2 2.1 1.2 / 4.1 4.2 4.3 1.1 3.0 Item Consists of Designation HF2P-versions 1.0 & 1.1 HF2P-version 1.2 1. Filter element See point 5 Replacement elements 1.1 Filter element On request 2. 1.2 O-ring (1.07.0XXDYYBN element) O-ring (1.07.XXDYYBH element) Clogging indicator or indicator plug VD 0 A.1 VD 0 A.1 /-V 24.99 x 3.53 (AS568A-214) 25.07 x 2.62 (AS568A-120) See Filter Clogging Indicator brochure 00305932 00305931 2.1 Indicator plug VD... 2.2 Profile seal ring VD... (AS586A-908) 2.3 O-ring 16.36 x 2.21 (AS568A-908) 15 x 1.5 3. BOWL For Bowl Assembly - consult factory 4. Seal Kit HF4P 2202431 2202434 SEAL KIT HF4P /-V 2202432 2202435 4.1 O-ring (element) See 1.2 above 4.2 O-ring (bowl) 53.65 x 2.62 67.95 x 2.62 (AS586A-147) 4.3 Back-up ring (bowl) 54.4 x 58.8 x 1.3 71.60 X 67.20 X 1.40 4.4 O-ring 20.29 x 2.62 (AS568A-117) - two required Other spare parts available on request Bold items can be ordered. -O-Ring durometer can range from 70-80Sh. EPR Seal Kits available on request. -Bowl assembly kits on request - kits include complete bowl with seals, and plug (if present). 4

5. Replacement Element Model Code Length (nominal inches) 04, 08 Filtration Rating (micron) 3, 6, 12, 25 = BN 3, 6, 10, 17 = BH Element Media BN, BH Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) FILTER MAINTENANCE 1. 07. 08 D 03 BN / V Supplementary Details SO263 = (same as above) SFREE = (same as above) 6. NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 5

Global Headquarters HYDAC INTERNATIONAL GMBH Industriegebiet D 66280 Sulzbach/Saar Germany Tel.: +49 6897 509-01 Fax: +49 6897 509-577 Internet: www.hydac.com Email: info@hydac.com North America Locations USA www.hydac-na.com Filter Division Cooling System Division 2260 City Line Road 1051 Airlie Parkway Bethlehem, PA 18017 Denver, NC 28037 Accessory Division 2204 Avenue C Bethlehem, PA 18017 Cooling System Division 445 Windy Point Drive Glendale Heights, IL 60139 +1.630.545.0800 Electronic Division Process Filter Division Accumulator Division 90 Southland Drive Bethlehem, PA 18017 Filter System Division Process Filter Division 580 West Park Road Leetsdale, PA 15056 +1.724.318.1100 Hydraulic Division 450 Windy Point Drive Glendale Heights, IL 60139 +1.630.545.0800 Mobile Hydraulic Division 1660 Enterprise Parkway Suite E Wooster, OH 44691 HYDAC CYLINDERS LLC 540 Carson Road North Birmingham, AL 35217 +1.205.520.1220 Canada 14 Federal Road Welland, Ontario, Canada L3B 3P2 +1.905.714.9322 Sales Office & Operations 1718 Fry Road, Suite 100 Houston, TX 77084 +1.281.579.8100 NE Sales Office 1660 Enterprise Parkway Suite E Wooster, OH 44691 SE Sales Office 1051 Airlie Parkway Denver, NC 28037 NW Sales Office 1201 NE 144th St. Bldg. B, Suite 111 Vancouver, WA 98685 Hydraulic Division Tech Center 430 Windy Point Drive Glendale Heights, IL 60139 +1.630.545.0800 www.hydac-na.com Sales Office 5160 75 Street NW Edmonton, Alberta, Canada T6E 6W2 +1.780.484.4228 Sales Office Montreal, Québec, Canada J2M 1K9 +1.877.539.3388 Mexico HYDAC INTERNATIONAL SA de CV Calle Alfredo A Nobel No 35 Col Puente de Vigas Tlalnepantla, Edo Mexico CP 54090 Mexico +011.52.55.4777.1262 www.hydacmex.com Copyright 2016 Brochure - Service HF2P