Vacuum Furnace Pumping Systems

Similar documents
Routine Compressor Maintenance

Combustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels

RELIABLE AND EFFICIENT SYSTEMS

6. Document tasks performed during visit and report any observations to the appropriate

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

2014 RAM C/V Tradesman

Crankcase Ventilation Manager (CVM) Installation Instructions

Scientific vapor pumps

Trillium US, Inc State Route 23 South Hamburg, NJ 07419

Varian, Inc. Vacuum Technologies. Rotary Vane Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models 6-19.

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

INSTALLATION INSTRUCTIONS

High vacuum transformer oil purification (HVTOPS) & Dielectric OIL Purifier System (DOPS)

Vapour Pumps. High Throughput Diffusion Pumps 108. Vapour Booster Pumps 114. Vapour Pumps for Scientific Instruments and R&D Applications 118

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

REMOVAL & INSTALLATION

Vacuum Pump Systems RUTA m 3 x h -1 (147 to 765 cfm)

INSTRUCTION MANUAL OIL SEALED ROTARY VACUUM PUMP MODEL PKS-016 PKS-030 PKS-070

CHBE320 LECTURE III ACTUATOR AND CONTROL VALVE SELECTION. Professor Dae Ryook Yang

To ensure proper installation, digital pictures with contact information to before startup.

SECTION 4 - FUEL SYSTEMS AND CARBURETION

Welker Heated Instrument Regulator

Two Stage Rotary Vane Vacuum Pumps Operation and Maintenance Manual

CENTAC Inlet and Bypass Valve Positioners

Conversion Processes 1. THERMAL PROCESSES 2. CATALYTIC PROCESSES

STARTER COMPONENTS FOR REMOVAL AND INSTALLATION

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630

Installation, Operation, and Maintenance Manual

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

AGILENT ROTARY VANE PUMPS

shop online:

CFM 1050 Reactive Closed Field Magnetron Sputtering System

AGILENT ROTARY VANE PUMPS

Installation Operation & Maintenance Manual. Rotary Piston Vacuum Pumps

WEBER CARBURETOR TROUBLESHOOTING GUIDE

Retrofitting Kit Filter Cleaning for Cable Coater ECC 700

NAF-Torex butterfly valves DN , Size 3-28, PN 10-40, ANSI Class 150, 300

Installation and Operating Manual

Workshop manual 5018 PDS Product Exploded View Disassembly & Assembling. Shock absorber 5018 PDS OEM Shock absorber 5018 PDS /2002

Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Stainless Steel.

Dual Stage Rotary Vane Pumps

Input, Control and Processing elements

Differentially Pumped Rotary Platform (DPRP) Instructions

Troubleshooting the Transmission Hydraulic System

IMPORTANT INFORMATION

Air Filter Element, Replacing and Cleaning Housing

Instruction Manual. 149-H/149-HS/212-J/412-J Microvac Pumps

Instruction Manual Appendage Ion Pumps

ALD3 Diaphragm Valve Technical Report

Troubleshooting The Transmission Hydraulic System

TE 91 PRECISION ROTARY VACUUM TRIBOMETER

INSPECTION AND MAINTENANCE CHECKLIST

CENTRAL SLURRY SYSTEMS Model 911

Oil Module in the Inner V

Installation, Operation, and Maintenance Manual

Tube Producing Conference September 23 rd 2013

USPI Oil Defender System COLOR-CODED START/STOP DESICCANT BREATHERS OIL LEVEL SIGHT GLASSES STAINLESS STEEL TOTES

TRICENTRIC VALVES TRICENTRIC METAL SEATED BUTTERFLY VALVE TRIPLE OFFSET

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Oxygen Probe Troubleshooting Guide Marathon Monitors, Inc.

10/20/ Ford E 250 Engine Mechanical > Engine, 4.6L and 5.4L > IN VEHICLE REPAIR > Intake Manifold 5.4L

Water Cooled Vacuum Valves, Gate and Poppet Style

Check List for Optimal Filter Performance

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

9/28/2018. Refrigeration compressor operation, maintenance and safety

PARTS MANUAL FOR TWO STAGE AIR COMPRESSOR

SUPERHONE Installation * Operation * Maintenance * Replacement Parts

TECHNICAL MANUAL OPERATOR S, UNIT, INTERMEDIATE (DS) AND INTERMEDIATE (GS) MAINTENANCE MANUAL FOR

Varian, Inc. Vacuum Technologies. TPS Turbo Pumping Systems. Features and Benefits 2-3. Mini-TASK AG TPS-compact 6-7

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

V- NOTCH BALL VALVE SERIES - 310

INJECTION MOULDING TROUBLESHOOTING GUIDE

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

COMPAK PRODUCTS QUEENSLAND M2S TO M310

Operation & Service Manual

COBRA NC B. Dry Screw Vacuum Pumps. Standard Equipment. Description

C07 RUVAC. Roots Vacuum Pumps Single-Stage m 3 x h -1 ( cfm) vacuum

Protector Glove Boxes.

Vacuum Pump Systems RUTA

Miniature Pneumatic Solenoid Valve

Oil Free Vacuum Pumps for Mass Spectrometry

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

A. General Specifications. B. Dimensional Layout. BTU International Specification: Model 150Nz12 Reflow Solder System Date: 11/05/09 Page: 1/6

Applied Fluid Mechanics

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

SUMP PUMP ASP-25 OPERATION & MAINTENANCE GUIDE

1999 F-150/250 Workshop Manual

Part number SP Acura RSX Type-S

TURBOMOLECULAR PUMPS ATP SERIES

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

WAC Air Curtains Technical Guide

READ AND SAVE THESE INSTRUCTIONS

Size: 57 (140 cm) W. x 30 (75 cm) D. x 75 (190 cm) H.

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

Air Boss Model M3000. Industrial Air Cleaner READ AND SAVE THESE INSTRUCTIONS. TRION

Spin Klin 3"-4" Apollo Angle

Terms. Direct Acting (DA) The action of a controller that increases its branch line pressure as the controlled variable increases

Applications. Compressor-Features The Vilter Advantages. LNG Boil Off Gas Gathering BIO - Gas Digester CO 2 Nitrogen Hydrogen Refrigerant

Transcription:

Vacuum Furnace Pumping Systems Failures and Solutions December 4, 2014 Presented By: William R Jones, CEO Solar Atmospheres Inc., www.solaratm.com Technical Contributors: Virginia M Osterman, Ph.D. Senior Scientist, Solar Atmospheres Inc. Reàl Fradette, MSME, Senior Consultant, Solar Manufacturing Inc.

Typical Vacuum Pumping System

P r e s s u r e 1E+03 1E+02 1E+01 1E+00 1E 01 760 Torr 15 Torr 40 Microns (µ) Actual Vacuum Pumping Speed Vs. Pressure 300 CFM Mechanical Pump Roots Vacuum Blower: 1650 CFM ( T o r r ) 1E 02 1E 03 Diffusion Pump: 20, 17,500 L/sec 1E 04 10 5 Torr Range 1E 05 0.001 0.01 0.1 1 10 100 1000 Pumping Speed (CFM). Solar Atmospheres Inc. 11/2014; R. Fradette

Actual Vacuum Pumping Speed Vs. Pressure Mechanical Pump (300 CFM) Roots Blower (1650 CFM) Diffusion Pump (17,500 L/S or 37,080 CFM) Pressure (Torr) Actual CFM Pressure (Torr) Actual CFM Pressure (Torr) Actual CFM 760 300 25 54.27 0.05 2.43 700 276.31 20 43.42 0.01 0.48 600 236.84 15 32.56 0.005 0.24 500 197.36 10 21.71 0.001 0.048 400 157.89 5 10.85 0.0005 0.024 300 118.42 1 2.17 0.0001 0.0048 200 78.94 0.5 1.08 0.00005 0.0024 100 39.47 0.1.21 50 19.73 0.05 0.10 25 9.86 Q = SP Solar Atmospheres Inc., 11/2014; R. Fradette

Air Leaks (2X10 6 ft 3 /hour).

Helium Mass Spectrometer

RGA Linear Scale Chart of Residual Gases After pumping to 10 4 Torr range Solar Atmospheres Inc., 2014, T. Jones

RGA Residual Gas Analyzer

Gas Species Effect On Thermocouple Vacuum Gauges 1000 100 Argon Nitrogen Actual Pressure (Torr) 10 1 Gauge Air Calibration Curve Hydrogen 0.1 0.01 0.01 0.1 1 10 100 1000 Solar Atmospheres Inc., 2008; T. Jones Indicated Pressure (Torr) as indicated by the T/C gauge SOLAR ATMOSPHERES,. INC.

Potential Sources for Leaks: Valves.

Butterfly Vacuum Valves Valve Positioner Every 2-3 years, remove the valve from flange and replace the shaft seal and O-Rings. Pneumatic Solenoid Shaft Seal O-Rings Valve Butterfly Disc Disc opens a full 90º. Flange Seal and Butterfly Disc Seal.

Foreline and Roughing Valve Care and Maintenance Butterfly type valves Require the least maintenance Designed for minimum wear and maintenance Replace valve seat every 2 years The valve disc should be rotated to the open position before the flange bolts are tightened* *In order to prevent valve from sticking.

Typical Main Valve.

Main Valve Poppet Type Electro-Pneumatic Solenoid Piston Cylinder Needle Valve Speed Adjustment Closed Limit Switch Piston Shaft Seal and O-Ring To Chamber To Roughing Valve- NO!!!! Poppet Valve Disc Poppet Valve O-Ring Seal To Diffusion Pump.

Main Valve Care and Maintenance Lubricate Piston Shaft and O-Ring every month with high grade vacuum grease. Replace Valve Disc and O-Ring annually.

Typical Stokes Mechanical Pump Exhaust Port Oil Separator Exhaust Valves Intake Port Slide Piston Eccentric Disc

Stokes Mechanical Pump Exhaust Valve Assembly Inspect Valve Seat for wear and cracking annually. Replace Springs and Valve Discs annually. Valve Springs Exhaust Valve Discs Valve Seat Caution Bolting Issue.

Stokes Mechanical Pump (Roughing) Normal Level - Center of sight glass or slightly below when pump is running Oil Level Sight Glass Where Oil Filtration Unit is Attached Oil Solenoid Valve Oil Drain Valve Oil Temperature Gauge Oil Flow Indicator Normal Operating Temp. 140 ºF - 160 ºF

Mechanical (Roughing) Pump Drive Belts Check Drive Belts for wear and adjust for proper tension. Drive Belts Correct tension should give ½ deflection when 3 to 5 lbs. is applied to midpoint. Too Tight Results in damage to the drive shaft bearings. Too Loose Belts will slip and cause excessive wear.

Roughing Pump Care Operators must check oil level and clarity weekly. Typical oil change - every 300 working hours or earlier if clarity decreases. Annually: Drain oil, remove this plate, clean oil sump, and replace exhaust valve springs and exhaust valve discs. Pump Oil Solenoid Valve Gas Ballast Valves - One on each side of pump Pump Oil Drain

Vacuum Pumping System Exhaust Line Drip Leg Drip Leg Drip leg collects dirty oil and moisture from roughing pump exhaust line. Check daily and drain as needed.

Roughing Pump Daily Maintenance Oil level: Pump running - Correct oil level is center of sight glass Add oil if required - Pump should not run with low oil level Check and drain drip leg Oil condition: - Good oil is clean and has good clarity. - Cloudy or milky oil shows presence of moisture Open gas ballast valves to eliminate moisture from oil; approx. 30 minutes Change pump oil if dirty or extremely milky.

Roots 615 Vacuum Booster Two figure-eight shaped Impellers Impellers rotate in the opposite direction at 3000 RPM..

Vacuum Booster Gear End Gear End Oil Fill Plug Check oil levels weekly. Oil level should be in the center of the sight glass (pump stopped). Every 2000 operating hours, change the oil in the bearing and gear reservoirs. Gear End Oil Level Site Glass Gear End Oil Drain Plug.

Vacuum Booster Critical Care Every month check drive belts for wear and adjust tension if necessary. Drive Belts- Test for ½ deflection when 3 to 5 lbs. is applied at midpoint. Too tight Results in damage to shaft bearings. Too loose - Belts will slip and cause excessive wear.

Direct Drive Vacuum Booster Design SOLAR ATMOSPHERES,. INC.

Alcatel Holding Pump Operate Continuously Operators must check oil level and clarity weekly. Oil level should be in the center of the sight glass. Pump Inlet from Holding Valve Pump Exhaust Port Gas Ballast Valve (operate closed) Oil Level Sight Glass

35 Varian Vacuum Diffusion Pump Diffusion Pump Inlet Attaches to and under the Main Valve. Copper Cooling Water Coils Diffusion Pump Foreline Connection Point to the Roughing Pump System Proper cooling water flow is essential. Cooling Water Inlet Connections Pump Heater Electrical Connection Box Oil Level Sight Glass SOLAR ATMOSPHERES,. INC.

Diffusion Pump Maintenance Recommended Oil: Dow Corning 704 Oil Level Sight Glass Full Hot Full Cold Normal oil level is determined by whether the diffusion pump is hot or cold. Operator must check the oil level monthly. Never open the oil drain or fill plug when the pump is HOT! Risk of Explosion!!

How A Diffusion Pump Operates The Main and Foreline Valves must be open. Residual gas molecules from furnace 5. When contacting the cold side walls, the oil returns to liquid form and returns to the bottom of the pump to be reheated. 4. As diffusion oil molecules return in a downward direction, the lighter gas molecules from the furnace are captured and forced down to the bottom of the pump. 6. The gas molecules are collected at the Ejector Nozzle and pulled out of the pump by the roughing system. 3. Oil mist particles are deflected from Jet Nozzles. 2. The molecules in the oil mist reach sonic speeds as they travel through the Jet Assembly. 1. Oil is heated to boiling and forced up through the center of the Jet Assembly as a mist. SOLAR ATMOSPHERES,. INC.

Diffusion Pump Maintenance Every twelve (12) months, clean the inside of the pump and change oil. Cleaning requires removing the pump from the Main Valve and removing Jet Assembly. Clean carbon buildup on boiler plate at bottom of the pump.

Diffusion Pump Jet Assembly SOLAR ATMOSPHERES, SOLAR ATMOSPHERES,. INC. INC.

Foreline Mechanical Baffle.

Diffusion Pump Heater Assemblies It is very important that the heaters be firmly bolted to the base.

Diffusion Pump Ammeters Vacuum Booster AC Drive Diffusion Pump Power Solar Conservac SOLAR ATMOSPHERES,. INC.

Maintenance Records Monthly Function Furnace One Furnace Two Furnace Three Change Roughing Pump Oil Change Holding Pump Oil Check Vacuum Booster Oil Check Holding Pump Oil Drain Exhaust Line Filter Grease Main Valve Clean Air Filters Check Belts Check Water Flow Ball Indicators Check Integrity of Door O ring Seal Check Air Line Oilers Inspect Entire Hot Zone

Maintenance Records (Cont d.) Six month/yearly function Furnace One Furnace Two Furnace Three Change Diffusion Pump Oil (Annually) Change Vacuum Booster Oil (Every six Months) Replace Door O ring seal (Every Three Months) Roughing Pump belt replacement (Annually) Clean Roughing Pump Reservoir (Annually) Check all Flowmeters (Annually) Do Electrical Cleaning

Solar Atmospheres Technical Booklets and Articles Critical Melting Points and Reference Data for Vacuum Heat Treating Temperature Uniformity Surveying of Vacuum Furnaces Operating a Vacuum Furnace Under Humid Conditions Understanding PID Temperature Control in Operating a Vacuum Furnace Understanding Power Losses in a Vacuum Furnace Important Considerations When Purchasing a Vacuum Furnace Considerations When Selecting a Vacuum Furnace Water Cooling System Reducing Energy Consumption When Operating a Vacuum Furnace Explaining Vacuum and Vacuum Instrumentation Understanding Emissivity and the Use of Thermocouple Test Blocks in a Vacuum Furnace Vacuum Gauge Correction Factors Leak Detection and Checking of Vacuum furnaces Critical Areas of Preventive Maintenance Evaluating Pan versus Rayon Graphite Felt Insulation for Vacuum Furnaces The Use of a Residual Gas Analyzer (RGA) to Determine Differences in Graphite and Allmetal Hot Zone Vacuum Operation (To be published)