Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Similar documents
OMRON Z LIMIT SWITCH

Direct Current Switch with Built-in Magnetic Blowout

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Best-selling Basic Switch Boasting High Precision and Wide Variety

Best-selling Basic Switch Boasting High Precision and Wide Variety

Best-selling Basic Switch Boasting High Precision and Wide Variety

Subminiature Basic Switch

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Best-selling Basic Switch Boasting High Precision and Wide Variety

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Low-torque Basic Switch

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Model Number Structure

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Small Limit Switch D4V

Subminiature Basic Switch

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Multiple Plunger Limit Switch

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

HL (AZH) LIMIT SWITCHES

Model Number Structure

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Manual Reset Limit Switch

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

AM1 (NZ BASIC) SWITCHES

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Safety Limit Switch

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form

Miniature Limit Switches

HL (AZH) Limit Switches

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

TURQUOISE STROKE SWITCHES

Pre-wired Models D4C- (1) (2) (3) (4)

Safety-door Switch. Ordering Information

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Turquoise Stroke Switches

Hinged Safety Door Switch

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

TURQUOISE STROKE SWITCHES

HL (AZH) Limit Switches

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Model Number Structure

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Tactile Switch (Hinged Type)

High Operating Precision Basic Switches with High Capacity and Long Life

Sliding contact construction Switches for Low-level Loads

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Mechanical Key Switch

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

PERFORMANCE IP67 (IEC60529, JIS C 0920) Silver contact: Max.50 mω (6 to 8 Vdc, energizing current 1A, measured by voltage drop method) Gold alloy cros

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

B3F. Miniature, Space-saving Switch

Turquoise Stroke Mini Switches

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

SL (AZ3) Micro Limit Switches

Ordering Information. Text Surface-Mounting Signal Relay G6K

Safety Limit Switch

Multiple Limit Switch

Ultra-miniature Size Switches with High Precision AH 1. Actuator. 0: Pin plunger 2: Hinge lever 4: Simulated roller lever N 0.25N 0.

WL-N/WLM-N. Two-circuit Limit Switch/Long-life Two-circuit Limit Switch

Limit Switches Technical Information

2NC (slow-action) Direct. Model. opening

Compact plastic limit switches with positive opening mechanism

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Model Number Structure

Ordering Information. Text PCB Power Relay G5LE

DL (AZD1) Mini Limit Switches

Transcription:

General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Ideal for switching DC circuits Wide variety of actuators for a wide scope of applications Same shape and mounting procedures as Omron s Model Z snap action switches. Ordering Information Terminal Solder terminal Screw terminal Actuator Model Model Pin plunger X-G X-G-B Terminal Solder terminal Screw terminal Actuator Model Model Hinge lever X-GW X-GW-B Slim spring plunger X-GS X-GS-B Low-force hinge lever X-GW4 X-GW4-B Short spring plunger X-GD X-GD-B Short hinge roller lever X-GW X-GW-B Panel mount plunger X-GQ X-GQ-B Hinge roller lever X-GW X-GW-B Panel mount roller plunger Panel mount cross roller plunger X-GQ X-GQ1 Model Number Legend X - G - 1 4 1. Ratings X-GQ-B X-GQ1-B Leaf spring X-GL X-GL-B Short hinge lever X-GW1 X-GW1-B : A (1 VDC). Contact Gap G: Reverse hinge lever X-GM X-GM-B Reverse short hinge roller lever * Reverse hinge roller lever * X-GM X-GM X-GM-B X-GM-B * The plungers of reverse-type models are continuously pressed by the compression coil springs and the plungers are freed by operating the levers.. Actuator None: Pin plunger 4. Terminals None: Solder terminal D: Short spring plunger B: Screw terminal S: Slim spring plunger (with toothed washer) Q: Panel mount plunger Q1: Panel mount cross roller plunger Q: Panel mount roller plunger L: Leaf spring W: Hinge lever W: Hinge roller lever W1: Short hinge lever W: Short hinge roller lever W4: Low-force hinge lever M: Reverse hinge lever M: Reverse hinge roller lever M: Reverse short hinge roller lever General-purpose Basic Switch X 141

Specifications Characteristics Operating speed 0.1 mm to 1 m/s (See note 1) Operating frequency Mechanical 40 operations/min Electrical 0 operations/min Contact resistance 1 mω max. (initial value) Insulation resistance 0 MΩ min. (at 00 VDC) Dielectric strength 1,00 VAC, 0/60 Hz for 1 min between terminals of the same polarity, between current-carrying metal parts and the ground, and between each terminal and non-current-carrying metal parts Vibration resistance Malfunction to Hz, -mm double amplitude (See note ) Shock resistance Destruction 1,000 m/s max. Malfunction 00 m/s max. (See notes 1 and ) Degree of protection IP00 Degree of protection against electric shock Class I Proof tracking index (I) 17 Ambient operating temperature C to 80 C (with no icing) Ambient operating humidity % to 8%RH Service life Mechanical 1,000,000 operations min. Electrical 0,000 operations min. Weight Approx. 7 to 6 g Note: 1. The values are for the pin plunger models.. Malfunction: 1 ms max. Ratings 8 VDC 14 VDC 0 VDC 1 VDC 0 VDC Rated voltage Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 0.7 7. 6.... Note: 1. The above values are for the steady-state current.. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).. Lamp load has an inrush current of times the steadystate current. 4. Motor load has an inrush current of 6 times the steady-state current. Contact Specification. The above electrical ratings also apply to the AC voltage. 6. With the reverse-type models (X-GM@), the normally closed circuits and normally open circuits are reversed. 7. The ratings values apply under the following test conditions: (1) Ambient temperature: 0± C () Ambient humidity: 6±%RH () Operating frequency: 0 operations/min Safety Standards Ratings Material Contacts Gap (standard value) Inrush current NC NO Silver 0 A max. 1 A max. UL/CSA Rated voltage X-G 1 VDC A 0 VDC A EN (CE) (Conform to EN68-1) Rated voltage X- 1 VDC A 14 General-purpose Basic Switch X

Engineering Data Mechanical Durability (X-G) Durability (x 4 operations),000,000 1,000 700 00 00 00 0 70 0 0 0 Ambient temperature: 0± C Ambient humidity: 6±%RH Without load Operating frequency: 40 operations/min Electrical Durability (X-G) Durability (x 4 operations) 00 00 00 0 70 0 0 0 7 1 VDC L/R = 7 ms Ambient temperature: 0± C Ambient humidity: 6±%RH Operating frequency: 0 operations/min 1 VDC L/R = 0 0 Structure Contact Form (SPDT) 0.1 0. 0. 0.4 0. 0.6 0.7 0.8 0.9 Overtravel (mm) (+) COM NC NO Note: With the reverse-type models (X-GM@), the NC and NO terminal arrangements are reversed. 1 0 4 6 8 1 14 Switching current (A) Dimensions Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Terminals Screw Terminals (-B) Solder Terminal (Blank) 9. 6.4 0 0 17.4±0..4±0.1 11.9 17.4±0. COM NO NC 1 49. Three, M4 x. Terminal screws (with toothed washer) 1 NO COM NC 49. Note: 1. Appropriate terminal screw tightening torque: 0.78 to 1.18 N m.. In case of DC voltage, set the COM to the positive terminal. Mounting All switches can be mounted using M4 mounting screws with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 1.18 to 1.47 N m. Two, 4.-dia. mounting holes or M4 screw holes Versions with panel mount plungers can be panel mounted via the plunger, provided that the hexagonal nut of the actuator is tightened to a torque of.94 to 4.9 N m. Panel Mount Plunger Panel Mount Roller Plunger +0. +0. 1. 0 dia. 1. 0 dia..4±0.1 +0. 0 Note: Mount using either the side mounting holes or the panel mount plunger, not both. If using the side mounting holes, then remove the hexagonal nut(s) from the panel mount plunger. Accessories (Terminal Covers, Actuators, and Separators): Refer to Z/A/X/DZ Common Accessories datasheet 1 +0. 0 General-purpose Basic Switch X 14

Note: 1. All drawings show the switches with screw terminals. For solder terminals, remove the -B from the end of the part number. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Pin Plunger X-G-B.±0. +0.07 4. -0.0 dia. hole. dia..sr *1 Slim Spring Plunger X-GS-B.±0. *1. dia. 4 dia. Short Spring Plunger 4. +0.07-0.0 +0.1 4.6-0.0 dia..4±0.1 49..±0. 1SR *1 11.9 17.4±0. 9. 4. *1. Stainless-steel pin plunger. Three vent holes dia. 7.1 dia. 4. Panel Mount Plunger X-GQ-B X-GD-B.±0. 1. dia. 11.9SR 1.1 * 16. 9 dia. 4. *1. Stainless-steel pin plunger (flat, 1R chamfering). Three vent holes 16 dia. 8. dia. M1 x 1 mounting screw *1 Two hexagonal nuts ( t x 14 width across flats) Two lock nuts ( t x 1.6 width across flats) *1. Plated iron plunger. Three vent holes *1. Stainless-steel pin plunger. Three vent holes *. Incomplete screw part with a maximum length of mm. Note: Do not use both the M1 mounting screw and the mounting holes in the case at the same time. Doing so will cause stress to be applied to the Switch, possibly damaging the case or cover. Panel Mount Roller Plunger X-GQ-B. ±0. 1.7 dia. x 4.8 *1 Panel Mount Cross Roller Plunger X-GQ1-B.±0. 1.7 dia. x 4.8 *1 1. * 16. 16 dia. M1 x 1 mounting screw Two hexagonal nuts ( t x 17 width across flats) 1. * 16. 16 dia. M1 x 1 mounting screw Two hexagonal nuts ( t x 17 width across flats) *1. Stainless-steel roller. Three vent holes *. Incomplete screw part with a maximum length of mm. Note: Do not use both the M1 mounting screw and the mounting holes in the case at the same time. Doing so will cause stress to be applied to the Switch, possibly damaging the case or cover. *1. Stainless-steel roller. Three vent holes *. Incomplete screw part with a maximum length of mm. Note: Do not use both the M1 mounting screw and the mounting holes in the case at the same time. Doing so will cause stress to be applied to the Switch, possibly damaging the case or cover. Leaf Spring X-GL-B 49.6±0.8 t = 0. *1 4.8 *1. Stainless-steel spring lever. Three vent holes Operating Characteristics X-G-B X-GS-B X-GD-B X-GQ-B X-GQ-B X-GQ1-B X-GL-B OF max. RF min. max. OT min. MD max. max. gf 0.1 mm 1.9±0.4 mm * Be sure to use the switch at the rated OT value of 1.6 mm. gf 1.6 mm 8.±0. mm gf 1.6 mm 1.±0. mm gf. mm 1.8±0.8 mm gf.6 mm.4±1. mm gf.6 mm.4±1. mm 00 gf 14 gf 1.6 mm *. mm.1 mm 17.4±0.8 mm 144 General-purpose Basic Switch X

Note: 1. All drawings show the switches with screw terminals. For solder terminals, remove the -B from the end of the part number. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Short Hinge Lever X-GW1-B Hinge Lever X-GW-B 6. 4.9 R 8. 4.9 R 6. 6. 9. 4. +0.07-0.0 4. +0.07-0.0 dia. holes 4.6 +0.1-0.0 dia. 17.4±0. 11.9.4 ±0.1. Three vent holes. Three vent holes 49. Low-force Hinge Lever X-GW4-B Short Hinge Roller Lever X-GW-B 9. dia. x 4 plastic roller 6. 6.6 R 4.9 R 6. 6.. Three vent holes Hinge Roller Lever X-GW-B *1. Stainless-steel spring lever. Three vent holes Reverse Hinge Lever X-GM-B 9. dia. x 4 plastic roller 6. 48 *1.R t = 1 4.9 18.6 6R. Three vent holes. Three vent holes Reverse Short Hinge Lever X-GM-B 9. dia. x 4 plastic roller t = 1*1 18.6 Reverse Hinge Roller Lever X-GM-B 9. dia. x 4 plastic roller.r 18.6 *1.6R t = 1 18 40 OF max. RF min. max. OT min. MD max. max. 0 gf gf.1 mm 1.7 mm X-GW-B 1 gf 14 gf 4.8 mm.9 mm. Three vent holes X-GW4-B X-GW-B X-GW-B gf gf 14. mm 4.8 mm.9 mm. Three vent holes Operating Characteristics X-GW1-B 0 gf gf.4 mm 1.7 mm 14 gf 1 gf 4 mm mm X-GM-B X-GM-B X-GM-B 0 gf gf. mm.1 mm 700 gf 1 gf mm 0.7 mm 0 gf 0 gf 4 mm mm. mm 4.6 mm 7.1 mm 40. mm 6.8 mm 6.1 mm 7.4 mm 0.7±0.8 mm 1.1±0.8 mm 1.1±0.8 mm.±0.8 mm.±0.8 mm 1.1±0.8 mm.±0.8 mm.±0.8 mm General-purpose Basic Switch X 14

Safety Precautions Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User s Guide, Snap Action Switches, Technical Information for correct use. Precautions for Safe Use Terminal Connection When soldering lead wires to the Switch, make sure that the capacity of the soldering iron is 60 W maximum. Do not take more than s to solder any part of the Switch. The characteristics of the Switch will deteriorate if a soldering iron with a capacity of more than 60 W is applied to any part of the Switch for s or more. Operation Make sure that the switching frequency or speed is within the specified range. 1. If the switching speed is extremely slow, the contact may not be switched smoothly, which may result in a contact failure or contact welding.. If the switching speed is extremely fast, switching shock may damage the Switch soon. If the switching frequency is too high, the contact may not catch up with the speed. The rated permissible switching speed and frequency indicate the switching reliability of the Switch. The life of a Switch is determined at the specified switching speed. The life varies with the switching speed and frequency even when they are within the permissible ranges. In order to determine the life of a Switch model to be applied to a particular use, it is best to conduct an appropriate durability test on some samples of the model under actual conditions. Make sure that the actuator travel does not exceed the permissible OT position. The operating stroke must be set to 70% to 0% of the rated OT. Precautions for Correct Use Mounting Location Do not use the switch alone in atmospheres such as flammable or explosive gases. Arcing and heat generation associated with switching may cause fires or explosions. Switches are generally not constructed with resistance against water. Use a protective cover to prevent direct spraying if the switch is used in locations subject to splashing or spurting oil or water, dust adhering. Install the switch in a location that is not directly subject to debris and dust from cutting. The actuator and the switch body must be protected from accumulated cutting debris and dirt. Incorrect Incorrect Terminal box Terminal box Correct Correct Do not use the switch in locations subject to hot water (greater than 60 C) or in water vapor. Do not use the switch outside the specified temperature and atmospheric conditions. The permissible ambient temperature depends on the model. (Refer to the specifications in this catalog.) Sudden thermal changes may cause thermal shock to distort the switch and result in faults. Incorrect Mount a cover if the switch is to be installed in a location where worker inattention could result in incorrect operation or accidents. Incorrect Subjecting the switch to continuous vibration or shock may result in contact failure, faulty operation or reduced service life due to abrasion powder. Excessive vibration or shock will cause the contacts to operate malfunction or become damaged. Mount the switch in a location that is not subject to vibration or shock and in a direction that does not subject the switch to resonance. If silver contacts are used with relatively low frequency for a long time or are used with microloads, the sulfide coating produced on the contact surface will not be broken down and contact faults will result. Use a microload switch that uses gold contacts. Do not use the switch in atmospheres with high humidity or heat or in harmful gases, such as sulfide gas (H S, SO ), ammonia gas (NH ), nitric acid gas (HNO ), or chlorine gas (Cl ). Doing so may impair functionality, such as with damage due to contacting faults or corrosion. The switch includes contacts. If the switch is used in an atmosphere with silicon gas, arc energy may cause silicon oxide (SiO ) to accumulate on the contacts and result in contact failure. If there is silicon oil, silicon filling, silicon wiring, or other silicon products in the vicinity of the switch, use a contact protection circuit to limit arcing and remove the source of the silicon gas. Handling Set the common (COM) terminal to the positive terminal. If it is set to the negative terminal, the Switch will not turn OFF. When using the Switch under an inductive load, the arc suppression capability varies depending on current. If the current becomes 0.6 to 1. A or of the time constant L/R exceeds 7 ms, be sure to provide an arc suppressor. Since the Switch incorporates a permanent magnet, attention must be paid to the following points: (a) Avoid mounting the Switch directly onto a magnetic substance. (b) Do not subject the Switch to severe shocks. (c) Avoid placing the Switch in a strong magnetic field. (d) Be sure to prevent iron dust or iron chips from adhering to the built-in magnet or the magnetic blowout function of the Switch will be adversely affected. (e) Do not apply thermal shock to the Switch, or the magnetic flux will be diminished. Since a ventilation hole is provided to avoid abnormal corrosion due to operating conditions, provide a dustproofing device in locations where the Switch is exposed to dust. Do not change operating positions for the actuator. Changing the position may cause malfunction. Panel-mounted Model (X-GQ@) Correct (preventing malfunctions) Correct Separate the installation location from heat sources. To side-mount the panel-mount Switch to the panel with screws, remove the hexagonal nut from the actuator. Too large a dog angle and too fast operating speed may damage the Switch when the Switch is side-mounted on the panel. Too fast operating speed and too long overtravel of the roller plunger Switch may result in damage to the Switch. 146 General-purpose Basic Switch X

General-purpose Basic Switch X MEMO

All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.097. To convert grams into ounces, multiply by 0.07. OMRON ELECTRONIC COMPONENTS LLC E. Commerce Drive, Suite B Schaumburg, IL 6017 847-88-88 Cat. No. X0-E-1 11/ Specifications subject to change without notice OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Printed in USA General-purpose Basic Switch X