VOLUMETRIC PUMPS. BOMBA ELIAS has developed the volumetric for clean water suitable for small flow rates and average height.

Similar documents
Do not touch rotating parts! ZONA CENTRO. c/ Oltra, Madrid Tel Fax:

User Manual. PBA428 Weighing platform

RoboSterz. Automatic Management of Steering Without Operator ITA. Mod. V.

User manual / 230 V. Electronically controlled motor, constant torque with intermediate reverse

Y8USE - 09, 12, 18, 24-5R

SAUTER TVO Version /2014 GB

TPHK Series Immersible Pump

Operating manual FP-2. Index

RI.15KI. L Rev. 04/03/02 MIKROCONTROLLER-STEUERUNG FÜR. Betriebsanleitung

TPHK Series Immersible Pump

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

1. GENERAL SAFETY INSTRUCTIONS 2. GENERAL SAFETY RULES GENERAL OBSERVATIONS.

TriScroll TM 300 Series Dry Scroll Vacuum Pump

230V 60Hz LINE FUSES AM CLASS:

TPAK Series COOLANT PUMP

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS AMP-22 MODEL

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

Mod: KLD6-12/35XLAS-N

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Operating Instructions

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

Crane fork KGM/KGA and KGQ/KGL

N CX 5500 DAT Operating and Instruction manual

Installation & Operating Manual

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

US - UP2/OIL 12V US - UP2/OIL 24V

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

Hardware User s Manual

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

MKT Series AUDIPACK. AUDIPACK Industriestraat GT Moerkapelle The Netherlands

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Owners Manual: - Pumps

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

ART. ITEM MAN Edizione 10/2009

DUNE DCT SERIES Manual

TYPE 41LA MINING LED LUMINAIRE EXPLOSION PROOF LUMINAIRE WITH FLAMEPROOF PROTECTION (TYPE d)

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

SUBMERSIBLE WATER PUMP

DulcoFlex Peristaltic Pump: DFB13B

Dumper OPERATOR S MANUAL

KSEV97X. IT Libretto Istruzioni GB Instruction Manual. 11 FR Manuel d Instructions 20 DE Bedienungsanleitung 29 NL Gebruiksaanwijzing

Dumper 1001, 1501, 2001 OPERATOR S MANUAL

SIZING OF SOLAR GENERATOR

Adam Equipment. TBB - TRIPLE BEAM Mechanical Balance Manual. 8141, RevD Nov2015 (ENG)

NECO Pumping Systems

HD-X2. Operating Instructions. Ref. No H /1232

Operator s manual Manuel d utilisation Manual de instrucciones. BLi520x BLi940x

Adam Equipment. User Manual (EN) Pricing Retail RAV Series Adam Equipment Co. Ltd.

Hardware User s Manual

Sandfiltration kit + Swimmey pump

DulcoFlex Peristaltic Pump DFC 50

Operating instructions

DulcoFlex Peristaltic Pump DFDa70

M Series Condensate Recovery Unit

Hardware User s Manual

Operating Instructions

Communicating Electronic Control for Fan Coil Units Régulation électronique communicante pour ventilo-convecteurs

EBARA COMPACT BOOSTER AM-PC

BLUSPM24. Instruction manual. Battery powered hydraulic pressing tool

TOTAL AIRTOOL SERVICES (UK) Ltd

c-go 24V/6A 24V/8A 24V/12A

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

DIAPHRAGM PUMPS: Instruction Manual

Compact System NRGS 11-2 NRGS Original Installation Instructions English

June14. Type

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain)

Heavy duty slurry pumps

Plunger Heads Use and Maintenance Manual

Powerflare Caution Light

ZS Stainless steel horizontal single stage centrifugal pump

POND PUMP Model Nos:SPP3 & SPP6 0200

6L Oil-less Air Compressor 53103

BELT CONVEYOR CB/M5 Series

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Vertical Chemical Pumps

TYPE NO. AS APPROPRIATE

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

Domestic Water Supply Pressure Pumps

8000 / 10,000 / 12,000

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

TOTAL AIRTOOL SERVICES (UK) Ltd

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

BLUCP 700E. Instruction manual. Compact hydraulic pump with accumulator

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

INSTALLATION AND OPERATING MANUAL. TM Series Multi-stage Pump

Mod. SC Man09. Manual sliding door USER AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

ART. ITEM

INSTRUCTIONS FOR INSTALLATION

DRENOX IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS. Mr. Proprietor

TOTAL AIRTOOL SERVICES (UK) Ltd

SUBMERSIBLE WATER PUMP

WATERFLUX 3070 Quick Start

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

VEM motors Thurm GmbH

Operating Instructions School Balance

Transcription:

VOLUMETRIC PUMPS NIZA PISCIS Introduction: BOMBA ELIAS has developed the volumetric for clean water suitable for small flow rates and average height. NIZA series are technopolymers volumetric pumps, and PISCES series are iron pumps with bronze impeller. They are trustworthy and robust pumps made of first class materials and submitted to rigorous test. Presentation: This manual is composed as follows: - Generalities - Transport and storage - Description of the pump - Installation/Assembly - Start up - Maintenance and conservation - Faults: causes and solutions - Relative literature SEDE CENTRAL Crta Molins de Rei a Rubí, km 8 7 08191 Rubí (Barcelona) Tel: 93.699.60.04 Fax: 93.697.16.09 Email: info@elias.es www.elias.es Manual VOLUMETRIC PUMPS Page: 1

Warning on safety and use: These symbols possibilities due to not respecting the corresponding indications. together with the words danger and attention indicate risk DANGER To disregard this warning could mean a risk of electrocution. DANGER To disregard this warning could mean harm to persons or objects. ATTENTION To disregard this warning could mean harm to the installation or to the pump. Before using the equipment, carefully read through this manual, it is necessary for your understanding and correct use of the pump and assures maximum performance whilst considering the safety of the worker. The electric part of the pump should be handled with the pump stopped and WITHOUT TENSION, the terminals box should be closed. The equipment should have electric and hydraulic disconnection devices, as well as allowing any maintenance work to be made safely. Transport and storage: The pump does not require any special transport conditions. The components of the pump are designed to support contractions y dilatations of the material. The pumps are packed to protect them from possible knocks during their transport on pallets or inside a compact box. Description of the pump: NIZA series are technopolymers volumetric pumps, and PISCES series are iron pumps with bronze impeller. They are equipped with electric motors, as per the European standard in force, with first class components, and are subjected to rigorous testing. Manual VOLUMETRIC PUMPS Page: 2

Installation and assembly: The group should be fixed on a flat, solid surface by means of screws using the holes on the motor or on the pump casing, depending on the model in order to avoid unwanted noise and vibrations. It should be situated as near as possible to the water level in order to obtain a minimum suction run and reduce load losses. It should be safe from any possible flooding and well ventilated Assembly of pipes: The suction and discharge pipes should have a diameter the same or superior to the inlet of the pump. They must be hermetic, air intake causes suction loss in the pump. Reduce to a minimum any elbow joints, strangling, all of which increase the load losses. Absence the elbow joints, that can produce air bags. It is convenient to install a foot valve. Neither the suction nor the discharge pipes should rest their weight on the pump. Electrical connection: The electric cable should correspond to EEC standards or to type HO7RN-F as per VDE 0250. The electrical installation should be protected by means of a differential switch. Single-phase motors are incorporated with thermal protection. For three-phase motors the end-user should foresee protection as per the legislation in force. The connection symbols (see drawing) make the electric connection easy. Controls prior to initial start-up: Check that the tension and frequency of the mains correspond to those indicated on the characteristics plaque. Make sure that the motor shaft turns freely. Check the priming of the pump (see the explanation Assembly of Pipes) Check that the sense of rotation of the motor coincides with that indicated on the fan cover. On three-phase motors, if the sense of rotation is incorrect, invert two phases on the protection panel. THE PUMP SHOULD NEVER RUN DRY Manual VOLUMETRIC PUMPS Page: 3

Start-up: Open all the gate valves that exist on the suction and discharge circuits. Check the absorbed current and duly adjust the thermal relay. If the motor does not work or does not extract water, try to discover the anomaly from the list of the most usual breakdowns and their possible solutions that figure in this manual. Maintenance and conservation: No maintenance is recommended, only in winter in places where the climate is particularly hard, draining of fluid the pump when this will not be used, avoiding freezing that can cause breakage or cracking. To store the pump, clean it and safe in a dry store. CONNEXIONS SKETCHES Single phase connexion Manual VOLUMETRIC PUMPS Page: 4

Faults: causes and solutions FAULT SOLUTION THE PUMP DOES NOT PRIME Blocked shaft Unblock with a screwdriver in the shaft groove Verify if the line has tension Lack of electric power Inadequate thermal THE PUMPS WORKS BUT DOES NOT GIVE CORRECT PERFORMANCE -Suction pipe less than that recommended -Suction valve partially closed -Air intake on the suction Low flow -Unprimed pump -Wrong sense of rotation -Suction pipe with counter-slopes that form air pockets -Suction valve partially closed -Air intake on suction -Wrong sense of rotation Little or unstable pressure -Counter-slopes on suction that for air pockets -Leaks Leaks through the mechanical seal -Impurities in pumped liquid -Damages wear faces -Dry running -Unprimed pump Seizure -Vibrations or similar -Suction of particles in suspension -Re-circulation with closed discharge -Incorrect electric power -Badly connected Incorrect working of the motor -Total or partial seizure of the motor -The thermal protection has gone off THE PUMP TURNS FULLY BUT DOES NOT MOVE THE FLUID Pump and suction pipe are not primed. Repeat the priming steps Obstructed impeller Clean it Wrong sense of rotation See installation instructions Excessive elevation height Verify the choice of pump THE PUMP GIVES INSUFFICIENT FLOW AT NOMINAL PRESSURE Air intake on the suction line or through seals Revise the suction line Impeller partially blocked Clean it Excessive elevation height Verify the choice of pump Turning speed too small Verify motor connections Manual VOLUMETRIC PUMPS Page: 5

FAULT SOLUTION THE PUMP GIVES INSUFFICIENT PRESSURE FOR THE NOMINAL FLOW Turning speed too small Verify motor connections Air or gas in the fluid Verify suction line THE PUMP ABSORBS EXCESSIVE POWER Turning speed very high Verify motor connections Density or viscosity of the liquid is very high Verify the pumping conditions or the choice of pump Flow excessively high or pressure very low Close the discharge valve THE PUMP WORKS WELL FOR A SHORT WHILE AND THEN STOPS Air intake on the suction line Verify valves, joints and flanges THE PUMP DOES NOT GIVE THE NOMINAL CHARACTERISTICS Excessive wear of the sealing surfaces of the impeller Replace the worn parts Valves or pipes obstructed Clean them Casing interior or impeller are corroded or eroded Replace necessary parts, check cavitations HOLE LEAK IN THE BODY Mechanical seal damaged Replace EXCESSIVE WORKING TEMPERATURE Bad ventilation of the equipment Improve the surrounding ventilation Very high pumpi ng temperature Reset it to correct one Systematic faults of the mechanical seal Abrasive particles in the fluid Clean the fluid Seal chamber with air pockets Ventilate Manual VOLUMETRIC PUMPS Page: 6

Advice on safety and use 1.- The tension indicated on the plaque must be the same as that of the mains. 2.- The working data figure on the plaque, check that they are those desired. 3.- To connect the pump to the mains, use a switch that cuts off all types of power. Install a differential switch as protection against lethal electric discharge. Connect the earth of the electric pump. 4.- Control that the motor is well ventilated. 5.- Use the pump for the performance indicated on the plaque. Manual VOLUMETRIC PUMPS Page: 7

6.- Do not install the electric pump within the reach of children 7.- Do not expose the pump outdoors and check any possible accidental leaks. Be careful of dangerous liquids and atmospheres make sure the equipment is adequate. 8.- Disconnect the pump from the mains before handling for repairs. Take care against the formation of ice. Manual VOLUMETRIC PUMPS Page: 8

Departamento/Département/Department/Abteilung DECLARACIÓN C.E. DE CONFORMIDAD DÉCLARATIÓN C.E. DE CONFORMITÉ E.C. CONFORMITY DECLARATION E.G. KONFORMITÄTSERKLÄRUNG DIRECCIÓN TÉCNICA DIRECTION TECHNIQUE TECHNICAL MANAGEMENT TECHISCHE LEITUNG DECLARAMOS bajo nuestra única responsabilidad que el equipo de trabajo: NOUS DÉCLARONS sous notre unique responsabilité que l equipe de travail: WE DECLARE, under our sole responsibility, that the product: WIR ERKLÄREN hiermit unter Verantwortung, dass die produkt: Marca/Marque/Make/Marke Bomba Elias Tipo/Type/Type/Typ centrifugal Modelo/Modèle/Model/Modell FT Nº Serie/nº Série/Serial Nº/Seriennummer Año construcción/année de construction/year of manufacture/baujahr 2011 se adapta a las normas: /s adapte aux normes: / accords with the regulatión: /den folgenden Normen entspricht: ha sido construido y es conforme con los requisitos esenciales de las Directivas: elle a été construite en conformité avec les conditions essentielles des Directives: has been built in agreement with the essential requirements of the Directives: ist nach den wesentlichen Anforderungen der folgenden Richtlinien konstruiert worden: Directiva de referencia: Directiva de Máquinas 2006/42/CE Norma EN 809 (Seguridad de Máquinas) Directiva de Baja Tensión 2006/95/CE Directiva EMC 2004/108/CE (Compatibilidad electromagnética) Norma armonizada: EN 60 335-1 Aplicada en particular EN 60 335-2-41 Directive of reference: Machinery Directive 2006/42/CE Standard EN 809 (Machinery Safety) Low Voltage Directive 2006/95/CE Electromagnetic Compatibility EMC 2004/108/CE Harmonised standard: EN 60 335-1. Applied in particular: EN 60 335-2-41. Con exclusión de responsabilidades sobre las partes o componentes adicionados o montados por el cliente. Avec exclusion de responsabilités concernant les parties ou les groupes ajoutés ou montés par le client. With no liability for the parts or components added or assembled by the customer. Unter Haftungsausschlus für die vom Kunden beigestellten oder angebauten Teile order Baugruppen. El fabricante / Le fabricant / The manufacturer / Der Hersteller c.e. mar-11 Fabricado por BOMBA ELIAS Ctra. Molins de Rei a Rubí, km. 8,700 08191 RUBI (BARCELONA) Teléfono: 34-(93) 699.60.04 / Fax: 93-697.16.09 e-mail: info@elias.es / página web: www.elias.es Francisco Elias Administrador / Administrator Manual VOLUMETRIC PUMPS Page: 9