SNR-FOSC-D. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-D. Installation Manual

Similar documents
SNR-FOSC-F. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-F. Installation Manual

HSC-O1. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC)

SNR-FOSC-H. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-H. Installation Manual

SNR-FOSC-D-T. Installation Manual SNR-FOSC-D-T. Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

Horizontal Fiber Optic Splice Closure (FOSC) Installation Manual

B1-OPCL Installation Manual

Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE. Installation Manual

Horizontal Fiber Optic Splice Closure (FOSC) FOSC-GPJ-A024. Installation Manual

FOSCHF Horizontal Fiber Optic Splice Closure

FOSC-400A4 INSTALLATION INSTRUCTION

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

FOSC-100 B/H FOSC-100 B2/H

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

OPTICAL FIBER CLOSURE

3000SC Fiber Optic Splice Closure

Fiber optic splice closure

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

CS Fiber Optic Splice Case. Instruction

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

3M Fiber Dome Closure FDC 10

Section 3 FIBERLIGN Closure Series

B Polyethylene Tape. B Splicing Covering. Holster

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

INSTALLATION INSTRUCTIONS

Closure End Plates and Accessories

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

OAsys. Outside Plant. Metallic Joint Closure VXOK units. Features and Benefits

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

19 1HU Splicing and Front Patching Shelf

WRSS Wraparound Repair Sleeve Installation Instructions

Heat Shrink closure Non - Pressurized & Pressurized RTSM Dome Closure RLSS RPBS Vault Closure Lead Sleeve Mechanical Closure Pillar Dp Jointing Kit

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

INSTALLATION INSTRUCTIONS

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit

COYOTE LCC (Low Count Closure)

Optical Fiber Closure. Fuzzy Integral Closure for Optical Cable VSOF-RN402A VISSEM. Electronics Co., Ltd.

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO COMPLY MAY VOID DAVIES, CRAIG WARRANTY.

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

Opti-Guard Splice Enclosure

Power Connection Kit installation instructions

Terminator DP/FAK-5 and FAK-5L

TOYOTA RAV TRAILER WIRE HARNESS Section I Installation Preparation

Scion xb Interior Light Upgrade Part Number: Accessory Code: YI1

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

FLOODLIGHT unit IMPORTANT WARNING! RRAC055/RRAC059. INSTALL TIME: 30 mins

Opticom Rack Mount Fiber Enclosures

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Toyota Prius Interior Light Upgrade

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

COYOTE Terminal Dome Closure 6.5" x 22"

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

ET-PWR-END-KIT Installation Instructions (part #JSR00)

Please note that these instructions apply to the Toyota Towing Wire Harness. The part you re looking for is PT

INSTALLATION INSTRUCTIONS

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

DARMAN. ENDURA II Cloth Towel Cabinet Product Guide. Manufacturing Company, Inc Lincoln Ave., Utica, NY 13502

TOYOTA TACOMA XM SATELLITE RADIO Preparation

Toyota Venza Interior Light Upgrade

6. Rear Drive Shaft REAR DRIVE SHAFT

4. Front and Rear Drive Shafts

MNBRATKIT MidNite Brat Solar Charging Kit

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

TOYOTA AVALON INTERIOR LIGHT UPGRADE Section TOYOTA II - Installation AVALON Procedures

1. General Description

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

HS6B Series Subminiature Interlock Switch

INSTALLATION INSTRUCTIONS

TOYOTA HIGHLANDER TRAILER WIRE HARNESS Preparation

Fiber Connector Shelf (CCS)

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

LiteDOT Installation Document

Universal Splice Tray Installation Instructions

Current parts on a ROTAX 125 MAX DD2 evo

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

SCION xd INTERIOR LIGHTING UPGRADE Preparation

SPEED CONTROL 4 AND 6 CYL. JEEP WRANGLER. Read entire instructions thoroughly before starting. INSTALLATION INSTRUCTIONS TOOLS REQUIRED:

for spiral staircases

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

C Power Connection Kit

Transcription:

(FOSC) SNR-FOSC-D Installation Manual

1. Scope of application This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation. The scope of application is: aerial, underground, pipeline, hand-holes. The ambient temperature ranges from -40 to 65. 2. Basic structure and configuration 2.1 Dimension and capacity Outside dimension (Height x Diameter) Weight (excluding outside box) Number of inlet/outlet ports Diameter of fiber cable Capacity of FOSC 288mm 178mm 1800g 1910g 4 pieces Φ8mm~Φ16 mm Bunchy: 4-48 (cores) 2.2 Main components No. Name of components Quantity Usage Remarks 1 FOSC cover 1 piece Protecting fiber cable 2 Fiber optic splice tray (FOST) Max. 4 trays (bunchy) splices in whole Fixing heat shrinkable protective sleeve and holding fibers 3 Fiber holding tray 1 pcs Holding fibers with Height x Diameter 208mm x 132mm Suitable for: Bunchy:4,6,8,12,(cores) protective coat 4 Base 1set Fixing internal and external structure 5 Plastic hoop 1 set Fixing between FOSC cover and base 6 Seal fitting 1 piece Sealing between FOSC cover and base 7 Pressure testing valve 1 set After inject air, it is used for pressure testing and sealing 8 Earthing deriving device testing 1 set Deriving metal parts of fiber cables in FOSC for earthing connection Configuration as per requirement Configuration as per requirement 1

2.3 Main accessories and special tools No. Name of accessories Quantity Usage Remarks 1 Heat shrinkable protective sleeve Protecting fiber splices Configuration as per capacity 2 Nylon tie Fixing fiber with protective coat Configuration as per 3 Earthing wire 1 piece Putting through between earthing devices 4 Abrasive cloth 1 piece Scratching fiber cables 5 Labeling paper 1 piece Labeling fibers 6 Special wrench 2 pieces Installing and tightening nut of reinforced core and nut (plastic) of inlet/outlet tube 7 Measuring paper 1 piece To measure perimeter, of which its diameter is enlarged with seal tape 8 Seal tape 1 ring Enlarging diameter of fiber cable which fits in with gasket ring. 9 Insulation tape 1 ring Enlarging diameter of fiber cable for easy fixing 10 Metal hoop 1 set For wall mounting and pole 11 Buffer tube decided by customers hugging Hitched to fibers and fixed with FOST, managing buffer. 12 Desiccant 1 bag Put into FOSC before sealing for desiccating air capacity To put through as per actual requirement To measure perimeter with the corresponding measuring paper Configuration as per specification Configuration as per requirement 3. Necessary tools for installation 3.1 Supplementary materials (to be provided by operator) Name of materials Scotch tape Ethyl alcohol Gauze Usage Labeling, temporarily fixing Cleaning Cleaning 2

3.2 Special tools (to be provided by operator) Name of tools Fiber cutter Fiber stripper Combo tools Usage Cutting off fiber cable Strip off protective coat of fiber cable Assembling FOSC 3.3 Universal tools(to be provided by operator) Name of tools Band tape Pipe cutter Electrical cutter Combination pliers Screwdriver Usage and specification Measuring fiber cable Cutting fiber cable Take off protective coat of fiber cable Cutting off reinforced core Crossing/Paralleling screwdriver Scissor Waterproof cover Metal wrench Waterproof, dustproof Tightening nut of reinforced core 3.4 Splicing and testing instruments (to be provided by operator) Name of instruments Fusion Splicing Machine OT DR Provisional splicing tools Usage and specification Fiber splicing Splicing testing Provisional testing Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves. 3

4. Installation flow chart 1. Open the closure 2. Determine length of fiber cable to be fixed and stripped inside FOSC 3. Strip off protective coats of fiber cable and fiber 4. Separate fiber cores and prepare work prior to fixing fiber 5. Fix fiber cable and reinforced core 6. Splice fibers 7. Install heat shrinkable protective sleeve and house fibers 8. Check up comprehensively 9. Assemble FOSC housing and fix FOSC 5. The process of installing FOSC. 5.1 Step One - Open the closure 5.1.1 Cleaning the locale and determine where to install the FOSC and then place fiber cables required. 5.1.2 Check whether the main components and accessories have been well prepared 4

inside the package. 5.1.3 Open the closure 1 demount hoop fixing bolt and pull hoop locking system out, then proceed in demounting the hoop. 2 Pull the FOSC cover upwards out, installation could begin. 5.1.4 See Drawing 1 Important issues: If the weather condition is not good enough, then a tent must be pitched for waterproof and dustproof. FOSC hoop (left) FOSC hoop (right) Hoop connector Hoop fixing bolt FOSC cover Hoop l ocki ng syst em Grommet FOST Fiber holding tray Label Fixing device for reinforced core Fixing seat Big gasket ring Inlet/outlet tube Nut (plastic) Base Bracket Drawing 1 5

5.2 Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC 5.2.1 1. in 110mm length: the distance from small gasket ring to fiber cable pressboard 2. in 1720mm length: it is used to be winded and spliced after stripping. 3. Fiber with protective coat in 120mm length: the distance from the fixing point of fiber cable to the fixing point of FOST (fiber optic splice tray). 4.Fiber in 1600mm length: after stripping off the protective coat, it is to be winded inside the FOST after splicing with other fibers 5.2.2 See Drawing 2 Important issues: 1. Reserve enough length of fiber cable to be spliced. 2. Stripping length also could be decided by customers according to installation requirement 110mm fixing length of fiber cable inside inlet/outlet tube 1720mm length of protective coat of fiber cable to be stripped off 120mm length of fiber with protective coat 1600mm length of protective coat of fiber to be stripped off Temp. locating mark Drawing 2 5.3 Step Three Strip off protective coat of fiber cable and fiber 5.3.1 Strip off protective coat of fiber cable from the temp. locating mark with the cutter and the stripper, please refer to Drawing 2 for stripping length. Stripping length also could be decided according to installation requirement 5.3.2 See Drawing 3. Important issues: If it is difficult to pull all the protective coat of fiber cable at one time, strip it off section by section to avoid fiber breakage. 6

Inlet terminal fiber cable Stripping terminal fiber cable Temp. locating mark Cutter Drawing 3 5.4 Step Four Separate fiber cores and prepare work prior to fixing fiber cable. 5.4.1 Wind 2 layers of insulation tape on protective coat of fiber core for protection. Meanwhile, get rid of the stuffing to separate fiber core and clean them. Form a ring with the diameter of 100mm or so and fix it on the fiber cable temporarily by adhesive tape. 5.4.2 Reserve reinforced core in 50mm length and cut off the unnecessary ones. 5.4.3 See Drawing 4. Important issues:inlet/outlet tubes are to be selected accurately to make it easy for splicing and sealing. 7

Reinforced core 50mm Drawing 4 Fiber with protective coat Adhesive tape Fiber Adhesive tape 5.5 Fix reinforced core, and pyrocondense, fix and seal fiber cable. 5.5.1 This FOSC is provided with 4 inlet/outlet tubes, which suits for fiber cable with max. diameter ф 16mm. 5.5.2 After deciding number of fiber cable inlet/outlet, demount the nut, gasket and gasket ring of the corresponding inlet/outlet tubes according to the diameters of fiber cables actually to be installed, insert them into fiber cable in sequence, then insert fiber cable into inlet/outlet cable, tighten the nut in order to seal properly. 8

5.5.3 While diameter is small, enlarge the diameter with seal tape at fixing position of small gasket ring, of which the perimeter is to be measured with measuring paper. 5.5.4 Fix fiber cable to the fixing seat, press it with the pressboard. While diameter is small, enlarge the diameter with insulation tape at the fixing position of fixing seat. 5.5.5 Demount the nut of fixing device of reinforced core with special wrench (plastic one), set the reinforced core into fixing slot, tighten the nut, retighten it with metal wrench (metal wrench to be provided by operator). 5.5.6 See Drawing 5 Important issue: Fixing nut of reinforced core should be tightened. Fixing slot of heat shrinkable protective sleeve Grommet Fiber with protective coat Adhesive tape FOST Fiber holding tray Fiber with protective coat Adhesive tape Fiber 90 ã Fiber Fixing seat Big gasket ring Inlet/outlet tube Seal tape Small gasket ring Gasket (plastic) Bracket (metal) Fixing device for reinforced core Reinforced core Base Inlet/outlet tube Nut (plastic) Nut (plastic) Drawing 5 5.6 Step Six - Splice fibers 5.6.1 Follow user manual of fusion splicing machine to splice fiber. Important issue: pay attention to the twist and bend of fiber 5.7 Step Seven -Install heat shrinkable protective sleeve and house fibers. 9

5.7.1 When having completed splicing the fibers, the first fiber ring should be housed on the farthest side of FOST, the remaining fiber should be winded, forming a ring with diameter not less than 80mm. then put it into FOST (Fiber Optic Splice Tray) together with heat shrinkable protective sleeve. ( Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of fiber ring properly.) 5.7.2 See Drawing 6 Important issue: pay attention to the twist and bend of fiber. FOST Grommet Fiber (bunchy or ribbon) Fixing slot of heat shrinkable protective sleeve (bunchy or ribbon) Heat shrinkable protective sleeve Fiber (bunchy or ribbon) Nylon tie Nylon tie Fiber with protective coat Fiber with protective coat Drawing 6 5.8 Step Eight - Check up comprehensively To ensure the technical requirements, the following instructions must be followed: 5.8.1 Fibers with protective coat are fixed with nylon tie at the entrance of FOST. 5.8.2 Grommet should be pressed from inside to outside in order to properly install FOST. 5.8.3 If there are fibers with protective coat reserved available, wind it into the fiber holding tray. 5.8.4 Check whether the internal tighteners and reinforced core are well tightened. 5.8.5 Check whether gasket ring is installed neatly and smoothly without any breakage. If not, level it up with seal tape. 10

5.8.6 See Drawing 7. Important issues: If any problems occur, they should be solved right away. Grommet Fiber holding tray FOST Fiber with protective coat Nylon tie Nylon tie Fixing device for reinforced core Reinforced core Pressboard Fixing device for reinforced core Bracket Big gasket ring Earthing deriving device Pressure testing valve Base Inlet/outlet tube Inlet/outlet tube Nut (plastic) Nut (plastic) Drawing 7 5.9 Step Nine Assemble FOSC housing and fix FOSC 5.9.1 Put FOSC cover on base directly. 11

5.9.2 Install plastic hoop between FOSC cover and the base, tighten hoop locking system, which is to be fixed by hoop fixing bolt then. 5.9.3 All nuts (plastic ones) of base need to be retightened once more. 5.9.4 FOSC installation 1 Aerial application: fix metal hoop and transom to the pole. Please refer to Drawing 8 2 Wall mounting application: fix the bracket on the wall with the bolt. (metal hoop is not required.) 3 Underground application: metal hoop is not required. 5.9.5. See drawing 8 Important issues: 1. Pay attention while installing plastic hoop. 2. The specification of the bolt for wall-mounting is M8. FOSC cover Hoop (metal) Label Hoop fixing bolt Hoop locking system FOSC hoop (left) Bracket (metal) Transom (metal) FOSC hoop (right) Inlet/outlet tube Base Nut (plastic) Drawing 8 12

6. Fiber Optic Splice Closures (FOSC) inspecting and testing items Inspecting item Package Appearance Sign Fiber storage device Electrical jointing device Sealing performance Re-sealing performance Pull Punching Technical Requirements Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual. There is a clear sign on the housing, such as name and model of the product, etc. The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa ± 5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. Bearing pull is 800N at axle orientation, there should be no breakage on the housing. Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing Inspecting type Routine test (Before leaving Type test factory) full At least 3 sets sampled each time At least 3 sets sampled each time 13

Impact Bending Torsion Temperature circle Voltage resistance strength Isolating resistance Bearing impact energy of 16N m, 3 times of impacts there should be not breakage on the housing The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±45 0 for 10 circles, there should be no breakage on the housing Bearing torsion 50N m, 10 circle at torsion angle±90 0, There should be no breakage on the housing. Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40 ~+65, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is 5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles. After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be 2 10 4 MΩ. At least 3 sets sampled each time At least 3 sets sampled each time 14

GUARANTEE: CONTACT: Address: Building 118, Vonsovskogo Street 1, Yekaterinburg, Russia Tel: +7(343) 379-98-38 Fax: +7(343) 379-98-38 E-mail: info@nag.ru Online shop: http://shop.nag.ru 15