WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

Similar documents
WARNING CAUTION WARNING CAUTION. User s Manual for GV-A High-Performance Gas Solenoid Valve for Industrial Applications, NOTICE SAFETY PRECAUTIONS

GV-A Manufactured by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

B21 Series BASOTROL Gas Valve

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter

Electric Top-Guided Single-Seated Control Valves

ACTIVAL Two-way Ball Valve with Threaded-end Connection

CIRCLE SEAL CONTROLS

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

CV3000 Series Pressure-Balanced Cage type Control Valve

High Pressure Service Cage type Double Seated Control Valves (Rating: ANSI 900 to 2500)

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

CIRCLE SEAL CONTROLS

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

V5197A Firing Rate Gas Valve

Motorized Two-Way Ball Valve with Screwed-End Connection

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Easytork Solenoid Valve IOM

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Digital Flow Switch (Sensor Part) Operation Manual

CV3000 Series Low-Noise Cage type Control Valve Model ACN

A superb way to save energy when using compressed air or nitrogen. Air Flow Meter CP-PC-1474E

Labyrinth Trim Angle Control Valves

Eclipse AutoTite Automatic Gas Shut-Off Valves

Electro- Hydraulic Actuator Gas Valves GH-5000

CV3000 Series Pressure Balanced Cage type Control Valve

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

Angle type Control Valves for High Pressure Service

Pilot Operated 2 Port Solenoid Valve for Dry Air

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A)

BGD278 Series BASOTROL CE Approved Gas Valve

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200)

3 Edition Product brochure GB AGA

HS6B Series Subminiature Interlock Switch

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Standard Specifications. Model. Port (Bypass lubrication adapter)

Model HIT. Corrosion-Resistant PTFE Body Control Valves OVERVIEW SPECIFICATIONS. No. SS

Three Way Control Valves

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection for High Differential Pressure Application (JIS 10K-FC200, -SCS13A)

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

GBV-G Balancing Valves

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

Old documentation - Only for your information! Product is not available any more!

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Ceramic Trim Angle Control Valves

Gas Conversion Kits and Instructions

VE4000 & VE5000 SERIES

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

D1 Series Top Guided Single Seated Control Valves

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (PN16 / GG-20) (Spring Return Type Actuator)

G72x Series Direct Spark Ignition Controls

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

V5055A-F Industrial Gas Valves

Cage type Single Seated Control Valves

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

I-799/79V Coil Components

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Tina 11A Connection block

User s Manual CM2-ALV nd edition

Standard Specifications. Model. Port (Bypass lubrication adapter)

HS1E Series Full Size Interlock Switch with Locking Solenoid

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

Industrial Turbo Meters, Sizes 2" through 6"

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection <4-20 ma DC Input with 4-20 ma DC Feedback Output> (JIS 10K-FC200, -SCS13A)

contents (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 User s Manual

Differential Pressure Transmitter

Cylinder and Valve: AirHawk II Air Mask

Free position locking flat and compact cylinder UFCD Series

Miniature Regulator Series ARJ310

WATERFLUX 3070 Quick Start

Diaphragm Valve Type 14 Pneumatic Actuated Type AV

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

Installation Instructions Studio Makeup Station

EX Series. Electric Actuators for Ball and Butterfly Valves

Easytork Vane Actuator IOM

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Top-Guided Single Seated Control Valves (Rating : ANSI 600 or Less)

FABER BURNER ROUTINE MAINTENANCE

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Scale Feeder Manifold Water Filtration System Instruction Manual

TOWA SEIDEN INDUSTRIAL CO., LTD.

Dual Port Manifold Water Filtration Systems Instruction Manual

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Transcription:

CP-UM-5706E Product by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications GV-A User's Manual WARNING Before wiring, installing, or removing the unit, be sure to turn off the power and gas supply. ailure to do so could result in an electric shock or gas leak. The unit should be installed, wired, adjusted, inspected, and maintained by specialists having sufficient knowledge and skills related to combustion and industrial furnaces. After piping and wiring the unit, be sure to perform gas leak inspections before supplying gas. ailure to do so might cause fire or device failure. CAUTION Photo: Valve with threaded flange (sold separately) Note Two dedicated pipe flanges (sold separately) are required for use of this product. High-Performance Gas Solenoid Valve for Industrial Applications. This manual contains information for ensuring the correct use of the GV-A. This manual should be read by those who design and maintain equipment that uses the GV-A. Also, the manual provides necessary information for installation, maintenance, and troubleshooting. Be sure to keep this manual nearby for handy reference. Please read the Terms and Conditions from the following URL before ordering or use: http://www.azbil.com/products/bi/order.html NOTICE Be sure that the user receives this manual before the product is used. Copying or duplicating this user s manual in part or in whole is forbidden. The information and specifications in this manual are subject to change without notice. Considerable effort has been made to ensure that this manual is free from inaccuracies and omissions. If you should find an error or omission, please contact Azbil Corporation. In no event is Azbil Corporation liable to anyone for any indirect, special or consequential damages as a result of using this product. 2014 Azbil Corporation All Rights Reserved. SAETY PRECAUTIONS Safety precautions are for ensuring safe and correct use of this product, and for preventing injury to the operator and other people or damage to property. You must observe these safety precautions. Also, be sure to read and understand the contents of this user's manual. WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user. CAUTION Cautions are indicated when mishandling this product might result in minor injury to the user, or physical damage to this product. Use this device only for natural gas, LPG (propane/ butane) and air. Using any other gas may corrode metal parts or deteriorate rubber parts, causing gas leaks or other problems. In keeping with gas combustion equipment standards and guidelines, use 2 valves in series for redundant shutdown. When using a gas that contains a large amount of dust (such as non-liquefied natural gas), install a gas filter upstream to reduce the risk of dust entering the valve. When using LPG, attach a mist trap, if necessary, to reduce the risk of any re-liquefied component (viscous substance) entering the unit. When removing the product from the package 1. Check the model number on the product label attached to the coil to make sure that you have received the correct product. 2. Check for any obvious damage. 3. Check the contents of the package against the packing list to make sure that all items are included. The contents of the package are listed below. Handle the product and accessories with care to prevent damage or loss of parts. If there is a problem, please contact the dealer promptly. Product name Model Qty Notes No. Valve unit GV-A 1 n Model number list (page 6) Cable gland set (M20) 2 GV-A GR (models with POC switch) 1 Models other than the above Bolt set 4 Set of bolts with octagonal washers and nuts Strainer 1 Already mounted on valve unit O-ring A (O-ring used tomount the threaded flange) Model number Date code Serial number PLEASE CHECK Product label of manufacturer Elster GmbH Azbil product label Model GV-A100LP0000 D/C 1012 S/N 98765 Distributed by Azbil Corporation 2D bar code 2 Already mounted on valve unit 1

RELEVANT USER S MANUALS A related user's manual is listed below. Refer to it as necessary. High-Performance Gas Solenoid Valve for Industrial Applications GV-A User's Manual for "Installation and Configuration" CP-SP-1356E. Alternatively, you can download the necessary manuals from http:// www.compoclub.com. OVERVIEW The GV-A high-performance gas solenoid valve for industrial applications is used as a safety shutoff valve for gas supplied to gas burners and other gas combustion devices. eatures This product consists of a valve unit and threaded flange, and includes a solenoid coil with a compact design. The maximum operating pressure is 50 kpa. This product is available in both quick opening and slow opening types. The quick opening type has a maximum flow rate adjustment (variable) mechanism. The slow opening type has an initial flow rate adjustment mechanism and a maximum flow rate adjustment mechanism. The valve close confirmation switch has an indicator that allows visual confirmation of operation. The valve is also available with a proof-of-closure (POC) switch. This device is compliant with EN 161. Also, size 1 of the valve has obtained SIL 3 and PL e certification. Blue LED shows turning on electricity to this product. Valve without a POC switch * unction inspection screw Solenoid coil O-ring A (2 locations) Valve with a POC switch PART NAMES Maximum flow rate adjustment screw Damper unit (Slow opening type only) Terminal box Terminal box cover Punch-out for wiring (2 locations) Strainer (Upstream side only) Maximum flow rate adjustment screw * unction inspection screw Damper unit (Slow opening type only) Cap Terminal box cover fixing screw Blue LED viewing window Pressure measurement ports (4 locations) : low direction mark Cap Blue LED which shows turning on electricity SIL 3 (Safety Integrity Level 3) Safety systems must receive safety certification (SIL) by a third party. SIL 3 is a level at which risk is reduced to between 1/1000 and 1/10,000 of the risk at a plant where safety measures are not adopted. SIL 1 indicates the risk is reduced down to the 1/10 1/100 range. Solenoid coil O-ring A (2 locations) Terminal box Terminal box cover Punch-out for wiring (2 locations) POC switch (POC switch type only) Strainer (Upstream side only) : low direction mark Terminal box cover fixing screw Blue LED viewing window Pressure measurement ports (4 locations) unction inspection screw This screw is used for function inspections. Do not turn it, as it is not supposed to be adjusted at the site. Turning it may cause an internal oil leak or make the valve unable to open. PL (Performance Level) The performance level indicates the ability of safety-related parts to perform a safety function. Hardware failure rates and software safety requirements were added to the qualitative requirements described in category B, items 1 to 4 in EN 954-1 and ISO 13849-1:1999 (JIS B 9705-1:2000) to provide quantitative safety levels designated from PL a to PL e. 2

PIPING AND WIRING (2) To tighten, grip the octagonal part of the pipe flange with a wrench. WARNING Connect the unit to the low-voltage side (G). If it is connected to the high-voltage side (H), a ground-fault current may flow into the unit, causing the valve to open and the gas to flow out, regardless of the burner controller. After completing the piping work, be sure to inspect for gas leaks. (3) When inserting the valve between the upstream and downstream pipe flanges. CAUTION Install vertically with the maximum flow rate adjustment screw facing up, or install horizontally. Note or instructions on joining two units together, or for other details, refer to the User's Manual for GV-A Gas Solenoid Valve for High-Performance Industrial Applications for Installation and Configuration (CP-SP-1356). PIPING Do not apply too much force to the valve unit when screwing the pipe. Doing so might damage the unit or cause a gas leak. Before piping Strainer check Check to make sure that the strainer in the inlet on the upstream side of the valve unit is in its proper place. Air flushing Before attaching the valve to the pipe, flush with air to remove metal shavings, burrs, and other foreign objects from the inside of the pipe. Piping work (1) Wrap sealing tape around the male threads of the pipe. (Or apply sealing compound.) Push both pipe ends apart and insert the valve, taking care not to damage the O-rings that are attached to each side. it the O-rings properly into their grooves. If they are not inserted sufficiently, the seal may not last. Connect the pipe flanges to the valve unit after attaching the O-rings and strainer. (4) Check the pipe flange position and the gas flow direction again, and then tighten the bolt part of the pipe flanges with a hexagonal wrench. Tighten to the appropriate torque below. Do not overtighten. Doing so might damage the threads, resulting in a gas leak. Bolt for valve size 1: 4.5 N m Bolt for valve size 2: 8.0 N m Bolt for valve size 3: 14.0 N m Tighten all octagonal nuts and washers so that they are in the Correct position shown in the following figure. If they are positioned as in the Incorrect example, the tapered part will not engage sufficiently and the flange will not be attached tightly, resulting in a gas leak. If using a sealing compound, apply the proper amount and do not apply to the area from the end of the thread to the second ridge An excessive amount of a sealing agent is applied. There are contaminants and burrs in the pipe An excessive amount of sealing compound, contaminants, burrs, etc., may block the strainer or reduce the flow rate. 3

Wiring Method (1) Decide which knockout to use for the power wiring. (2) Without removing the terminal box cover, use a screwdriver or other tool to tap the plug out. Punch-out (3) Remove the terminal box cover. (4) Put the cable through the included M20 cable gland. Remove the cover (5) Put the M20 cable gland through the knockout hole. (9) Tighten the nut outside the box to secure the cable. (10) Attach the terminal box cover. When using the POC switch on a low-voltage circuit, be sure to separate the wiring to the low-voltage circuit from the wiring to the line voltage used to drive this device, in order to prevent any induction from the line voltage. Raise the connector part from the circuit board to wire the POC switch. After wiring, place the connector back in its original place without turning it upside down. ADJUSTMENTS Maximum flow rate adjustment and initial flow rate adjustment Adjustment mechanism Maximum flow rate adjustment Initial flow rate adjustment Slow opening type Approx. 20 to 100% of Approx. 0 to 70% * Quick opening type the maximum flow rate * Initial flow rate < Maximum flow rate Maximum flow rate adjustment With 100% as the maximum, the valve opening can be adjusted within approximately the 20 100% range. (6) Inside the terminal box, put the cable through the cable gland nut. (7) Tighten the nut inside the terminal box to secure the M20 cable gland to the terminal box. Initial flow rate adjustment The initial flow rate is the flow rate at which the gas is supplied immediately after the power is turned on. The slow opening valve type, which has an initial flow adjustment function, is available to prevent explosive ignition. When the power is turned on, the slow opening type gradually opens within a maximum time of about 10 seconds. The flow rate at startup is adjustable within a range of about 0 70 %. Adjusting the maximum flow rate The factory default setting is at the maximum flow rate. As required by the application,the maximum flow rate can be adjusted. Turn the flow rate adjustment screw with a hexagonal wrench. (8) Connect the high potential wire (H) to LV1(+) and the low potential wire (G) to N(-). Connect the ground wire to the ground terminal. Valve without a POC switch Scale max min Relationship between valve travel and flow rate LV1 ( ) N ( ) Valve opening (scale) 100 Valve with POC switch Cable for POC switch 1 2 3 LV1 N ( ) ( ) Supply voltage line for the drive 0 20 100 low Rate (U) 1 2 3 When valve is closed 4

Adjusting the initial flow rate (slow opening type only) Changing the initial flow rate also changes the opening time. Relationship between the time and flow rate The valve gradually opens from the initial flow rate to the maximum flow rate in about 10 seconds. The factory default rate is 0 %. The initial flow rate can be adjusted as needed. Relationship between rotation of the damper unit and initial flow rate low Rate Adjustment range of initial flow rate 0 70% Note 100% 70% 0% 0s Up to 5 full turns are possible. To allow the damper unit to operate completely, it is necessary to leave an interval of 20 seconds after the valve is closed and before the power is turned back on. (1) Tighten the setscrew with a hexagonal wrench. Set screw Adjustment to 70% (Turn counter-clockwise approx. 5 full turns) Adjustment to 0% (at shipping) (2) Turn the damper unit clockwise (tightening) to decrease the initial gas flow. Turn it counterclockwise (loosening) to increase the initial flow. Adjust the flow rate. 10s Damper unit (3) Tighten the setscrew with a hexagonal wrench. Time low rate characteristics The graph assumes a specific gravity of 0.65, temperature of 15 C, and pressure of 101.325 kpa. Differential Pressure (kpa) 10 1 0.1 1 WARNING Check the gas solenoid valve for external and internal leaks at least once a month. After piping and wiring the unit, be sure to perform gas leak inspections before supplying gas. ailure to do so might cause fire or device failure. Inspection 2 3 4 5 6 20 30 40 50 60 10 100 low Rate (m 3 /h) 110 GV-A100 + 10A flange 115 GV-A100 + 15A flange 120 GV-A100 + 20A flange 125 GV-A100 + 25A flange 225 GV-A200 + 25A flange 232 GV-A200 + 32A flange 200 300 1000 External gas leak inspection Close the manual valves (1) and (3) in the figure, and check for any leaks using a gas detector or a leak detector solution. Internal gas leak inspection Close only the manual valve (1), shown in the figure, connect a rubber hose to the end of the manual valve (3), and then place the end 10 mm below the water surface to see if any bubbles come out. Gas leakage amount 40 ml/h or less (GV-A100, 200) 60 ml/h or less (GV-A300) (When 50 kpa is applied, for both internal leaks and external leaks) This unit 110 115 MAINTENANCE 120 125 225 232 240 250 340 350 365 240 GV-A200 + 40A flange 250 GV-A200 + 50A flange 340 GV-A300 + 40A flange 350 GV-A300 + 50A flange 365 GV-A300 + 65A flange 2 1 Gas Graduated cylinder 3 Water 5

n Model Number List Base model number GV-A Valve size Operation type Rated supply voltage POC switch SPECIICATIONS POC switch orientation Inspection report Additional process Description High-Performance Gas Solenoid Valve for Industrial Applications 100 Valve size 1 (for port sizes 10A, 15A, 20A, 25A) 200 Valve size 2 (for port sizes 25A, 32A, 40A, 50A) 300 Valve size 3 (for port sizes 40A, 50A, 65A) N Quick opening type L Slow opening type P 100 Vac Y 200 Vac *1 G With POC switch *2 0 Without POC switch *1 R Right side as viewed from POC switch and upstream side *2 0 None D With inspection report 0 Without inspection report 0 None Note: Obtain the dedicated flange (sold separately) to match the pipe size to be used. *1 If "G" is selected for POC switch, only "R" can be selected for the POC switch orientation. *2 If "0" is selected for POC switch, only "0" can be selected the POC switch orientation. n Parts Sold Separately Threaded flange One threaded flange is included. Two pipe flanges are required for each valve. Model number Product name Product code* 74921504 Port size 10A for valve size 1 LV110R/B 74921505 Port size 15A for valve size 1 LV115R/B 74922229 Port size 20A for valve size 1 LV120R/B 74922230 Port size 25A for valve size 1 LV125R/B 74922231 Port size 25A for valve size 2 LV225R/B 74922232 Port size 32A for valve size 2 LV232R/B 74922233 Port size 40A for valve size 2 LV240R/B 74922234 Port size 50A for valve size 2 LV250R/B 74922235 Port size 40A for valve size 3 LV340R/B 74922236 Port size 50A for valve size 3 LV350R/B 74922237 Port size 65A for valve size 3 LV365R/B * The product code is a product identification code that is printed on the product package, and it is separate from the model number. The valve size and pipe diameter are indicated by this code. Seal set This set includes O-rings used for joining two valves together. Cable gland set To join two valves with POC together, connect their terminal boxes. Model number Product name 74921985 or valve size 1 74921986 or valve size 2 74921987 or valve size 3 Bolt set and strainer set Use them for maintenance purposes, if necessary. The required number of all items below is included with the initial purchase of the valve. Model number Product name 74921992 Bolt set for valve size 1 74921993 Bolt set for valve size 2 74921994 Bolt set for valve size 3 74921997 Strainer set for valve size 1 74921998 Strainer set for valve size 2 74921999 Strainer set for valve size 3 Bolt set Strainer set Model number Product name 74921988 or valve size 1 74921989 or valve size 2 74921990 or valve size 3 Bolt 2 Strainer 1 Strainer 2 O-ring* 2 Nut 2 * O-ring used to mount the threaded flange 6

Specifications Gas types Natural gas, LP gas (propane, butane) *1 Maximum operating 50 kpa pressure Connection Rp (parallel female threads for ISO7-1 pipe) Cv value See the tables below for the flow rate characteristics, mass, and power consumption. Gas leakage 40ml/h or less (GV-A100, 200) 60 ml/h or less (GV-A300) (when 50 kpa is applied, for both internal leaks and external leaks) Valve housing Aluminum alloy Valve sealing material NBR Rated supply voltage 100 Vac +10%/ 15%, 50/60 Hz 200 Vac +10%/ 15%, 50/60 Hz (depending on the model) Allowable ambient temperature -20 C to +60 C (without condensation) Storage ambient temperature -20 C to +40 C (without condensation) Protection class IP65 (except for electrical wire ports) Standards compliance EN 13611 and EN 161 class A group 2 Opening operation Quick opening and slow opening types Valve opening time 1 second or less (quick opening type) Approx. 10 seconds or less (slow opening type) Valve closing time 1 second or less Initial flow rate adjustment 0% 70% (slow opening type only) Maximum flow rate 20 100% adjustment range POC switch contact rating 12 to 30 Vdc, 2 to 100 ma *2 (POC: proof of closure) POC switch lifespan 200,000 operations Accessories Without POC switch: M20 cable ground (1), flange O-ring (2), bolt set (4), operation manual With POC switch: M20 cable ground (2), flange O-ring (2), bolt set (4), operation manual Operation lifespan The operation lifespan per valve unit is compliant with EN 13611 and EN 161. Model number Lifespan Operation count (number of operations) Number of years GV-A100, V-A200 200,000 10 GV-A300 100,000 10 This is based on the operation count or the number of years, whichever is smaller. Prolonged operation at high temperatures can result in premature wear of rubber materials and an operation lifespan shorter than the above values. *1 The mass of the quick opening type is approximately 0.2 kg lighter than that of the slow opening type. *2 The mass of the non-poc switch type is approximately 0.1 kg lighter than that of the POC switch type. (In the case of the double-valve configuration, it is approximately 0.2 kg lighter.) low Rate Characteristics, Weight, and Power Consumption low rates are for 15 C and 101.325 kpa Model number Connection port diameter low rate (m 3 /h) at differential pressure of 0.25 kpa Specific gravity 0.65 Specific gravity 1.53 GV-A100 10A (Rp 3/8) 15A (Rp 1/2) 8.5 10.9 5.6 7.1 5.8 7.5 1.8 1.8 33W (37VA) *2 20A (Rp 3/4) 16.4 10.7 11.2 1.9 25A (Rp 1) 18.6 12.1 12.7 1.8 GV-A200 25A (Rp 1) 32.8 21.4 22.4 4.3 53W 32A (Rp 1 1/4) 41.1 26.8 28.1 4.2 (59VA) *2 40A (Rp 1 1/2) 45.6 29.7 31.2 4.3 50A (Rp 2) 46.4 30.3 31.7 4.1 GV-A300 40A (Rp 1 1/2) 65.9 43.0 45.0 5.6 53W 50A (Rp 2) 71.4 46.5 48.8 5.5 (59VA) *2 65A (Rp 2 1/2) 74.3 48.4 50.8 5.2 *1 Power consumption increases by 20% in -20 C. *2 These VA are reference values. Cv Mass (kg) Power consumption *1 100V 200V 33W (37VA) *2 54W (60VA) *2 54W (60VA) *2 7

External Dimensions Quick opening type without POC switch with POC switch G G E E LOW H1 H2 LOW H2 H4 L1 L1 Slow opening type without POC switch with POC switch E G E G H3 H5 LOW LOW H2 L1 H2 L1 Model Connection port number diameter GV-A100 10A (Rp 3/8) 15A (Rp 1/2) 20A (Rp 3/4) 25A (Rp 1) GV-A200 25A (Rp 1) 32A (Rp 1 1/4) 40A (Rp 1 1/2) 50A (Rp 2) GV-A300 40A (Rp 1 1/2) 50A (Rp 2) 65A (Rp 2 1/2) Dimensions (mm) L1 *1 E H1 H2 H3 H4 H5 G *2 75 15 91 23 75 143 32 208 161 226 109 128 30 85 170 47 235 191 256 134 155 36 85 180 59 245 201 266 142 *1 The dedicated flange (part ) is sold separately. *2 The G dimension was calculated based on data provided by the manufacturer. Specifications are subject to change without notice. (09) 8 1-12-2 Kawana, ujisawa Kanagawa 251-8522 Japan URL: http://www.azbil.com 1st Edition: Issued in Mar. 2014 ( K )