UNIBLOC-GP Operation & Service Manual

Similar documents
UNIBLOC-PD Operation & Service Manual

LABTOP OPERATION AND SERVICE MANUAL (SERIES ) ORIGINAL INSTRUCTIONS

Pneumatic Actuator. Operation & Service Manual. Models: Original Instructions UNIBLOC PUMP MANUAL NO.: REVISION: 08/2016

Model 617 Benelli Tactical Light. Users Manual. Benelli Shotgun M1 Super Gauge Serial No. M and later Protected by US.

Spring-Engaged/Hydraulically-Released BD Caliper Brake. (i) MTY (81) QRO (442) MEX (55)

DeZURIK 2 20" BOS BUTTERFLY VALVES

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Service Guide JATCO Environmental Protection Tank Model J-7000

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Installation, Operation and Maintenance of Airflex Model AA2, B2, B3 and C2 Rotorseals

5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button

Model Beretta Tactical Light. Users Manual. Beretta 1200 PF 12 Gauge Shotgun Protected by US. Patent 4,856,218 Revision D 7_1_97

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

MetroPrime 22MPC Self-Priming Centrifugal Pump

MEX (55) QRO (442) Web Controls

S h a f t S e a l INSTALLATION INSTRUCTIONS. For Shafts : 4 to 6 (100 to 150mm)

FCB-450, LCB-600, MCB-800

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Serial Number Purchase Date

Straight-Bore Clutch LSCC-32, 44, 54

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

Installation and Maintenance Instructions

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

All products subject to this warranty must be returned for examination, repair or replacement to:

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

AK / AV 4 & 5 SERIES Metallic Vertical Centrifugal Pumps Installation and Maintenance Instructions

RV-10 Center Arm Rest Console

DAP-625S and DAP-875S

DeZURIK KUL KNIFE GATE VALVES

Prime Attachments & Custom Fab Brush Mower Owners/Operators Manual

Kit Part Number:

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

Installation and Maintenance Instructions

Dodge SpynTec Hub Conversion Kit

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL

Air and water reels. Models and Series B. Installation and maintenance guide DANGER

ReelGreen RG20 Instruction Manual For Operation and Maintenance

Single Post Caliper Brake VC500

Operation and Safety Manual

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416

Operating and Installation Instructions

Installation, Operation and Maintenance of Airflex Quick Release Valve

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

MODEL BARE REEL SERIES E

COMPRESSED AIR LOADER MODEL: AL-1

ATD Gallon Pressurized Oil Drain Owner s Manual

INSTALLATION INSTRUCTIONS

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Installation and Maintenance Instructions

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

HYDRAULIC POWER PACK

Model 8317 Combination Shower Eye/Face Wash

Smartflow FasTie Quick-Connect Ejector Tie-In System

OPERATING INSTRUCTIONS ZDX 7-1/2AS

CV Control Valves Installation and Operation Manual

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

PARTS LIST. Guardian A- Series. Material Pumps

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Pump Installation and Service Manual HRS Hydromatic Retractable System

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

INSTALLATION INSTRUCTIONS

WARRANTY REGISTRATION AND POLICY

Installation, Operation and Maintenance of the Airflex Model BT Rotorseal Assembly

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

203 TRANSFER CASE CONVERSION

Instruction set # 7068 Cognito Motorsports, Inc. Upper Control Arm Leveling Kit for GM 8-Lug #UCAK (Boxed Style)

REPLACING ROLTEC SPRING ARMS

Hose reel. Models and Installation and maintenance guide. Danger

OWNER S MANUAL GUZZLER MODEL 620 READ THESE INSTRUCTIONS BEFORE USING

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

advanced FLOW engineering Instruction Manual P/N: & Make: Chevrolet Model: Camaro Year: Engine: V6-3.

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

ECONOMAIR SERIES CYLINDERS

Float Level Control Kits

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

BA440 PISTON. Hydraulic Air Compressor

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Operating Manual High Viscosity Dispense Valve Item #

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Cognito Motorsports, Inc. Upper Control Arm Kit for 2011-Present GM 8-Lug #UCAK100051

SUMMIT PUMP Horizontal End Suction Pump Close Coupled and Frame Mounted

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

I Button Chemical Dispenser. Overview. Installation Instructions

Loctite 300ml Cartridge Pusher Part Number EQUIPMENT Operation Manual

SMPT OSA1 / 4. VISAGAGE ORIFICE SELECTOR Patent #9,433,144

HSIV PLOW OPERATOR S MANUAL

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

II DISTRIBUTION & SUBSTATION TYPE C

5874PB/5874PBF/VRK5874/VRK5874HF/ PBA6/ PBA7 Valve/Push Button

INSTALLATION INSTRUCTION & OWNER S MANUAL

Electric Actuator Installation, Operation & Maintenance Manual

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Installation and Maintenance Instructions

Transcription:

UNIBLOC-GP Operation & Service anual odels: 275-375 ANUAL NO.: GP275-375 REVISION: 01/2017 Original Instructions UNIBLOC PUP

UNIBLOC PUP Unibloc-Pump, Inc. 1701 Ashborough Road SE arietta, Georgia 30067 USA Tel 770-218-8900 Fax 770-218-8442 E-ail info@uniblocpump.com www.uniblocpump.com Unibloc-Pump AB Lantvärnsgatan 4 652 21 Karlstad Sweden Tel +46-54-219000 Fax +46-54-212402 E-ail info@uniblocpump.se www.uniblocpump.se Information contained in this manual is subject to change without notice and does not represent a commitment on the part of Unibloc-Pump. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the express written permission Unibloc-Pump. Copyright 2017 Unibloc-Pump. All Rights Reserved. Revision Date: 01/2017 anual No.: GP275-375

UNIBLOC -GP OPERATING INSTRUCTIONS: Check lines for obstructions. If supply tank is positioned below the pump inlet, prime the pump first. Check front cover nuts to make sure they are properly tightened. Open supply and discharge line valves. Energize drive motor. Adjust motor speed to achieve desired output flow (consult flow charts for optimum operating range). SHAFT SEAL SERVICE: PUP HOUSING Disengage power to the pump drive and the system. System pressure must be relieved before working on the pump. Isolate the pump from the rest of the system by shutting off valves at the pump ports. Use caution when removing the cover (2) as there may be product remaining in the pump. Remove the wing nuts (17) and cover (2). Slide off the gears (3a, 3b). If they will not slide off they can be pulled off together with the pump housing (1). Remove the pump housing (1) by tapping gently with a rubber mallet on the ports. Do not rock the housing back and forth as doing so may damage the shaft seal. Service the shaft seals according to the instructions below. UNIBLOC-GP 275 SINGLE O-RING SEAL All seal parts will come off with the housing. Remove the retainer ring (39) by unscrewing the bolts (32). The o-rings (40a, 40b) can now be removed. Check the shaft for wear. If grooves are noticeable, it may have to be replaced or the o-ring (40b) may not seal properly or may fail prematurely. Place new o-rings (40a) into the grooves of the retainer ring (39). Apply a lubricant on the shaft, o-rings, and the pump housing bore with a lubricant approved for use with the pumped product. Attach the retainer ring to the pump housing with the bolts (32). See the Pump Housing Installation instructions below to complete the service. UNIBLOC-GP 275 SINGLE LIP SEAL All seal parts will come off with the housing. Remove the Lip Seal (54) by unscrewing the bolts (32). O-ring (49) can now be removed. Check the shaft for wear. If grooves are noticeable, it may have to be replaced or the seal may leak or fail prematurely. Place a new o-ring (49) into the groove of the Lip Seal (54). Apply a lubricant on the shaft, o-ring, and the pump housing bore with a lubricant approved for use with the pumped product. Attach the the Lip Seal (54) to the pump housing with the bolts (32). See the Pump Housing Installation instructions below to complete the service.

UNIBLOC-GP 275 DOUBLE LIP SEAL All seal parts will come off with the housing. Remove the Lip Seal (53a) by unscrewing the bolts (32). O-ring (49) can now be removed. Check the shaft for wear. If grooves are noticeable, it may have to be replaced or the seal may leak or fail prematurely. Place a new o-ring (49) into the groove of the Lip Seal (54). Apply a lubricant on the shaft, o-ring, and the pump housing bore with a lubricant approved for use with the pumped product. Attach the the Lip Seal (54) to the pump housing with the bolts (32). See the Pump Housing Installation instructions below to complete the service. UNIBLOC-GP 275 SINGLE ECHANICAL SEAL Remove the seal nose ring (B) and o-ring (33a) by pulling them out of the housing. Remove the mating ring (A), the o-ring (33b), and the washer (D) by sliding them off the shaft. To avoid damage, handle and store the loose seal nose ring (B) and the mating ring (A) so that their lapped sealing surfaces do not get scratched. If missing, insert the dowel pins (46) in the shaft and pump housing. Coat the shaft and pump housing bore with a product compatible lubricant. Place the o-ring (33b) in the mating ring (A) first, and then the washer (D). Slide the mating ring, slotted side first, on the shaft. Place the spring washer (C) between the pins (46) in the pump housing. Place o-ring (33a) in the groove of the mating ring (B). Align the slots of the mating ring with the pins in the pump housing. Push the mating ring into the pump housing, o-ring side first. Press several times to make sure it slides easily. Place a product compatible lubricant on the mating ring and the seal nose ring sealing surfaces. See the Pump Housing Installation instructions below to complete the service. UNIBLOC-GP 300-375 SINGLE O-RING SEAL All seal parts will come off with the housing. Remove the retainer ring (39) by unscrewing the bolts (32). The o-rings (40a, 40b) can now be removed. Check the shaft for wear. If grooves are noticeable, it may have to be replaced or the seal may leak or fail prematurely. Place new o-rings (40a, 40b) into the grooves of the retainer ring (39). Attach the retainer ring to the pump housing with the bolts (32). Coat the o-rings and the shaft with a lubricant approved for use with the pumped product. See the Pump Housing Installation instructions below to complete the service. UNIBLOC-GP 300-375 DOUBLE O- LIP SEAL All seal parts will come off with the housing. Remove the bolts (50), the split washers (51), and the retainer ring (52). Pull the cartridge (53a) out of the pump housing bore. Check the shaft for wear. If grooves are noticeable, it may have to be replaced. Place new o-rings (49) into the groove of the seal cartridge. Clean the rotor housing seal bore. Apply product compatible lubricant to the bore and shaft. Place the pump housing so that the seal bore is pointing up, push the seal cartridge (53a) in, lip side first. Attach the retainer ring (52) to the pump housing with the split washers (51) and the bolts (52). See the Pump Housing Installation instructions below to complete the service.

UNIBLOC -GP UNIBLOC-GP 300-375 SINGLE ECHANICAL SEAL The optional retainer ring (31), the bolts (32), the mating ring (A), and the mating ring o-ring (33a) will all come off with the pump housing. Unscrew the bolts (32) to remove the retainer ring (31), the mating ring (A), and the mating ring o-ring (33a). Slide the seal nose ring (B) and the seal nose o-ring (33b) off the shaft. To avoid damage, handle and store the loose seal nose ring and the mating ring so that their lapped sealing surfaces do not get scratched. If not being replaced, the drive collar (C) may remain on the shaft, otherwise loosen the set screws (D) and slide them off the shaft. The shaft and the pump housing bore should be cleaned before installing the seal components. Slide the drive collar (C) on the shaft. oisten the seal nose o-ring (33b) with water or coat them with a lubricant that is acceptable for use with the product. Slide the seal nose o-ring on the shaft and then the seal nose ring (B), slotted sides first. Align the slots in the seal nose ring with the pins in the drive collar. Push the seal nose ring against the drive collar so that the o- ring seats properly. Place the mating ring o-ring (33a) in the pump housing seal bore. Only lubricate this o-ring with water or alcohol. Push the mating ring into the pump housing so that it seats flat with the step in the housing. Some applications require pins to be used in the mating ring. When placing it in the pump housing align the pins with the holes in the pump housing and press in the ring. Do not use objects to push it in that will scratch the mating ring seal surface. Place a product compatible lubricant on the sealing surfaces. If the retainer ring (31) was supplied with the pump, bolt it to the pump housing. See the Pump Housing Installation instructions below to complete the service. After installing the housing push the drive collar toward it compressing the wave spring and leaving a 2-3mm (0.08-0.12 ) gap between the collar and the seal nose ring (B). Tighten the set screws (D). UNIBLOC-GP 300-375 DOUBLE O-RING SEAL All seal parts will come off with the housing. Remove the seal housing (41) by unscrewing the bolts (32). The o-rings (40a, 40b, 40c) can now be removed. Check the shaft for wear. If grooves are noticeable, it may have to be replaced or the o-rings (40b, 40c) may leak or fail prematurely. Place new o-rings into the grooves of the seal housing (41). Attach the flush housing to the pump housing with the bolts (32). Coat the o-rings and the shaft with a lubricant approved for use with the pumped product. See the Pump Housing Installation instructions below to complete the service. Fill the cavity between the o-rings with product compatible grease before resuming operation. PUP HOUSING Tighten the studs (15) if needed. Slide the pump housing (1) on the studs (15). Slide on the gears (3a, 3b). With the cover o-ring (28) in place, put the cover (2) on and thread the wing nuts (17) on the stud ends. Tighten them in a cross pattern until there is no clearance between the cover (2) and the pump housing (1) face. Open the valves and then power to the drive may be engaged.

Part Number Item Pcs. Description 200/07 200/10 275/22 275/38 300/28 350/40 375/52 1 1 Pump Housing GP114D GP116D GP117D GP119A GP3000-1L GP3020-1L GP3040-1L 2 1 Cover 3200-1L 3210-1L 3a 1 Drive Gear 3b 1 Lay Gear application specific; contact factory or refer to order 4 1 Drive Shaft GP2040-21 GP2070-21 GP3060-21 GP3070-21 GP3080-21 5 1 Pin Shaft GP101-3 GP104-3 GP3100-3 GP3110-3 GP3120-3 6 1 Bearing Housing (ss) GP182-2 or GP183-2 GP3151-2 or GP3152-2 Bearing Housing (alum.) GP182-5 or GP183-5 GP3151-5 or GP3152-5 8 1 Spacer GP105-3 GP3170-4 9 1 Front Bearing 10 1 Rear Bearing 3750 3755 12 1 Tab Washer 4500-4 4505-4 13 1 Slotted Nut 4402 4412-4 15 4 Housing Stud 3258-2 GP3600-2 GP3610-2 GP3620-2 16 4 Cover Dome Nut 4400-2 4410-2 17 4 Cover Wing Nut 4401-2 4411-2 19 4 Bolt 4316-2 22 1 Key 4701 4706 23 1 Front Oil Seal 4105-N 4115-N 24 1 Rear Oil Seal 4106-N 4111-N 28 1 Cover O-ring 4200-E 4215-E 29 1 Foot (optional) 3801-2 3806-2

UNIBLOC -GP Ø K J2 J1 UNIBLOC - GP 275 G H HORIZONTAL THROUGH-PUT D1 E1 C F E2 D2 VERTICAL THROUGH-PUT B A1 A2 A1 A2 B C D1 D2 GP275-07/07 3/4" TRI-CLAP 155 (6.10) 20 (0.79) GP275-10/07 GP275-10/10 GP275-15/15 1" TRI-CLAP 1" TRI-CLAP 1.5" TRI-CLAP 3/4" TRI-CLAP 20 (0.79) 110 (4.33) 167 (6.57) 26 (1.02) 26 (1.02) E1 128 (5.04) 121 (4.76) E2 128 (5.04) 121 (4.76) F 49 (1.93) 37 (1.46) G 117 (4.61) H 62 (2.44) J1 53 (2.09) 65 (2.56) J2 53 (2.09) 65 (2.56) K 147 (5.79) 82 (3.23) Ø 12 (0.47) ALL DIENSIONS IN, INCHES IN ( ). Ø K J UNIBLOC - GP 300-375 GP300 GP350 GP375 G HORIZONTAL THROUGH-PUT D E C F A A 1" TRI-CLAP 1.5" TRI-CLAP B C D E F G H J K 32 (1.26) 165 (6.50) 197 (7.76) 154 (6.06) 181 (7.13) 39 (1.54) 170 (6.69) 43 (1.69) 162 (6.38) 85 (3.35) 138 (5.43) 209 (8.23) 112 (4.41) Ø 19 (0.75) ALL DIENSIONS IN, INCHES IN ( ). 2" TRI-CLAP 46 (1.81) 175 (6.89) 221 (8.70) VERTICAL THROUGH-PUT

WARRANTY UNIBLOC-PUP warrants every part of our product against poor workmanship and defective materials (wear items excluded) for a period of one (1) year from the date of shipment. If during this period the item does not conform to its performance parameters as a result of poor workmanship and/or defective materials, return the faulty item, shipping prepaid and fully insured, to an authorized UNIBLOC-PUP service facility. If, upon inspection of the item in question, poor workmanship or defective materials are revealed, UNIBLOC-PUP will repair or replace it, at UNIBLOC-PUP s option, and will return it by shipping it F.O.B. the service facility. This warranty is void if the item has not been used as recommended or instructed, has been altered or used with unauthorized accessories, has been subject to misuse, abuse or accident, or has been damaged due to causes not related to poor workmanship or defective materials. All parts or components not manufactured by UNIBLOC-PUP are warranted only to the extent of the warranty of the respective manufacturers. ALL IPLIED WARRANTIES, INCLUDING THE IPLIED WARRANTIES OF ERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXPRESSLY EXCLUDED. IN NO EVENT SHALL UNIBLOC-PUP OR ITS AFFILIATES BE LIABLE TO ANYONE FOR SPECIAL, COLLATERAL, INCIDENTAL, OR CONSEQUENTIAL DAAGES, WHETHER ARISING IN CONTRACT OR IN TORT. UNIBLOC-PUP RESERVES THE RIGHT TO AKE TECHNICAL CHANGES WITHOUT NOTICE. UNIBLOC PUP Unibloc-Pump, Inc. 1701 Ashborough Road SE arietta, Georgia 30067 USA Tel 770-218-8900 Fax 770-218-8442 E-ail info@uniblocpump.com www.uniblocpump.com Unibloc-Pump AB Lantvärnsgatan 4 652 21 Karlstad Sweden Tel +46-54-219000 Fax +46-54-212402 E-ail info@uniblocpump.se www.uniblocpump.se Copyright 2017 Unibloc-Pump, Inc./ Unibloc-Pump AB Patented Designs Shown