/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L?

Similar documents
Vortex Eggs Delta Flowmeter

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

Digital Flow Switch (Sensor Part) Operation Manual

Helical Flow. HF-GC/GP Series

Model 1000 Vortex Meter

Diaphragm Valves Type 15

A Member of the. Integrated Metering Technologies

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

PFA Eddysonic flowmeter

Hydro-Flow Model 3100

Octave Water Meter Installation Manual

Filterpack FR-BFP2-(H)0.4K to (H)15K

This section is specifically about safety matters

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Diaphragm Valve Type 72

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

Model 5000 Vortex Meter

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Liquid Turbine Flow Meter OwnerÊs Manual

A Member of the. Integrated Metering Technologies

EVS RP6020. Instruction Manual

Positive displacement flowmeter for continuous flow measurement

CDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

Installation and Operating Manual

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

3-Way Ball Valve Type 23H

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Positive Displacement Flowmeters GM020 series instruction manual

SIGNET 7002 Vortex Flow Sensor ENGLISH

Positive Displacement Flowmeters GM020 series instruction manual

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Inline Ultrasonic Flowmeter

Read and understand this manual for safely usage.

IMPORTANT SAFETY NOTICE

Precision Clean Regulator

The experts in fluid technology

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water

Liquid Turbine Flowmeter

Positive Displacement Flowmeters GM007 series instruction manual

OPERATING INSTRUCTIONS

1.Safe testing IMPORTANT:

Signet 7000/7001 Vortex Flow Sensors * *

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

CATALOG KTLU. Vortex Flowmeter

Series AV2000/3000/4000/5000

RP Instruction Manual

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

EZ-IN Series Turbine Flowmeter

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Model Pressure range ON/OFF output Linear output

Series 8000 Vortex Flow Meter

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY

Pressure sensor with built-in amplification and temperature compensation circuit

Safety design conforming to the following provisions

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Sediment strainer (Type Y)

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

Armstrong In-Line and Insertion Vortex Flow Meters

MODEL 900 IMPELLER-TYPE FLOW METER

Diaphragm Valve Type 14 Pneumatic Actuated Type AP. User s Manual. Contents H-A065-E. Serial No.

7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance

MODEL 1100 TURBINE FLOW METER

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Diaphragm Valve Type 14 Pneumatic Actuated Type AV

1. Preface For best results, please refer to this manual before using this product. 2. Safety precautions Model Precautions DFS-1 The maximum pressure

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

WATERFLUX 3070 Quick Start

Hydro-Flow Model 2200 Installation and Operation Guide B

Harness the Power of the Sun

SIGNET Vortex Flow Sensors ENGLISH

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

TECHNICAL INSTRUCTIONS

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

M x Series Valve Linkage Kits

Butterfly Valve Type 58 (PDCPD)

TIDALFLUX 2300 F Quick Start

AM1 (NZ BASIC) SWITCHES

Pressure sensor for liquid and gaseous media QBE620-P...

Pressure Transmitter JUMO dtrans p30 Type

ION JET NOZZLE NIH-55

Soft Start-up Valve. AV2000/3000/4000/5000 Series

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

Flow sensor for compressed air

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Transcription:

Vortex Flow Monitor /OVAL Eggs DELTA Pulse OPERATION MANUAL MODEL : FLP? L A G 1 2 FLP? L? SA G 1 2 FLP? L? G 1 2 P N A Every Sparling/OVAL vortex flow monitor Eggs DELTA Pulse is fabricated and shipped from our factory under stringent quality control. In order to maintain its design performance throughout its life, this manual offers the operator the necessary installation, operation and maintenance information. Be well familiar with these instructions before you place the meter in service and keep this manual at the field location for ready reference. 1

CONTENTS 1. BEFORE YOU BEGIN... 3 1.1 Confirming the Specification Plates... 3 1.2 Transportation Considerations... 3 1.3 Storage Considerations... 3 2. OPERATING CONDITIONS... 4 3. GENERAL... 4 3.1 Features... 4 4. COMPONENT NAMES AND FUNCTIONS... 4 5. INSTALLATION... 5 5.1 Installation Location... 5 5.2 Physical Orientation... 5 5.3 Installation Procedure... 5 5.4 Flushing... 6 5.5 Tubing Connections... 6 6. WIRING INSTRUCTIONS... 7 7. OPERATION... 8 8. TROUBLESHOOTING... 8 9. GENERAL SPECIFICATIONS... 9 10. PRODUCT CODE EXPLANATION... 10 11. OUTLINE DIMENSIONS... 11 CONVENTIONS Shown in this manual are the signal words NOTE, CAUTION and WARNING, as described in the examples below: NOTE: Notes are separated from the general text to bring the user s attention to important information. CAUTION: Caution statements signal the user about hazards or unsafe practices which could result in minor personal injury or product or property damage. WARNING: Warning statements signal the user about hazards or unsafe practices which could result in severe personal injury or death. Reminder We are not liable for faulty conditions of, or damage to this product, and consequential damage to properties or personnel caused by any of the following: Modification and repair made by others than by Sparling/OVAL Consequence of using a product made by others Failure to observe the precautionary notes, operating conditions, or procedure prescribed in this manual Natural disasters, such as fire, earthquake and thunderbolt 2

1. BEFORE YOU BEGIN IDS FLP Every Eggs DELTA Pulse is thoroughly inspected and tested before it leaves the factory. When received, it should be thoroughly inspected for indication of rough handling during transit. Be sure to adhere to the following instructions: CAUTIONS 1. Eggs DELTA Pulse is not compatible with flammable, corrosive, or toxic fluids. 2. Eggs DELTA Pulse is made of synthetic resin; avoid exposure to the sun. 3. Eggs DELTA Pulse is a non-explosionproof product and is not serviceable in explosionproof areas (hazardous locations). WARNING: Negligence of the above warnings can result in damage to the product. Necessary handling precautions are described in this section; read the instructions carefully. As for other information, find the respective sections. For any inquiries, contact your nearest Sparling/OVAL designated sales office. NOTE: When you make inquiries, include the product name, model number, stock number, ratings and other pertinent information. 1.1 Confirming the Specification Plates Eggs DELTA Pulse is assembled and adjusted according to individual customer specifications. Product code number and ratings are stated on the sides of preamplifier. Make sure that the ratings shown conform to your particular specifications, along with GENERAL SPECIFICATIONS on page 9 and PRODUCT CODE EXPLANATION on page 10. Specification Plate 2 Specification Plate 1 Specification Plate 1 1.2 Transportation Considerations Specification Plate 2 (1) It is desirable that Eggs DELTA Pulse be transported to the installation site in the shipping container used for transit from the factory. (2) Eggs DELTA Pulse is adjusted and inspected as one complete assembly consisting of the flowmeter body, sensor subassembly, and preamplifier. Be sure to treat them as an integral assembly, not attempting to disassemble them. 1.3 Storage Considerations If Eggs DELTA Pulse upon receipt is to be stored for long periods of time before installation, unexpected faulty conditions could arise. If a long-term storage is anticipated, take the following precautions: (1) Keep the equipment in store in the same shipping container used for transportation from Sparling/OVAL if possible. (2) Place of storage should conform to the following requirements: Free from rainwater and moisture. Free from vibration and impact shocks. Temperature and relative humidity in the storage place are at room temperature and humidity (around 25 C and 65%). 3

(3) Purge the Eggs DELTA Pulse that has once been placed in service with clean air, nitrogen gas, etc. to prevent the metered fluid from adhering to the meter connections, piping inner walls, housing, etc. before storage. (Wash clean with suitable detergent if necessary). CAUTION: Do not use solvents, such as thinner or alcohol, for cleansing. (4) For long-term storage, it can best be stored in the shipping container used for transportation from the factory. 2. OPERATING CONDITIONS Eggs DELTA Pulse operating conditions appear on its specification plates, in the installation requirements on pages 5 and 6 and the general specifiactions on page 9. 3. GENERAL Eggs DELTA Pulse, a small, lightweight vortex flowmeter, uses a piezoelectric sensor. Behind the bluff body, Von Karman vortices form and shed proportional to the rate of flow on alternating sides of the bluff body placed perpendicular to the stream of flow. Eggs DELTA Pulse picks up the frequency of these vortices with the sensor for flowrate measurement. Sensor Karman Vortices Bluff Body Meter Body Flow Direction 3.1 Features (1) Absence of any moving parts contributes to long service life. (2) Lightweight and compact with major parts made of resin molding. (3) May be installed in any physical orientation. Fig. 3.1 4. COMPONENT NAMES AND FUNCTIONS Signal Cable (one meter long furnished) 3 Metal Coupling 2 Connection Thread 1 Flow Direction Connection Thread Vortex Shedding Column (Bluff Body) Fig. 4.1 No. Part Name Functions 1 2 3 Meter Body Sensor Preamplifier Consists of the measuring tube and bluff body (vortex shedding triangular column) Karman vortices form and shed behind the bluff body as the process fluid flows. Has a built-in piezoelectric element. Oscillates by Karman vortices and picks them up as changes in electric charge. Amplifies changes in electric charge from the sensor, shapes the waveform and provides a pulse output (open collector). 4

5. INSTALLATION 5.1 Installation Location Select an installation location that meets the following conditions. CAUTION: It is not serviceable in explosionproof areas (hazardous locations). (1) Free from rainwater and moisture. CAUTION: Avoid exposure to the sun. (2) Temperature does not change widely (desirably within a range from 0 to +60 C. (3) Free from vibration and impact shock (desirably pipeline oscillation below 0.2 G). (4) Easy to access for servicing. (5) Where pipeline remains filled with the process fluid with no air bubble entrapment (in liquid measurement). (6) Process fluid pressure is held below the maximum permissible pressure 0.98MPa. (7) Where the process fluid will not freeze. 5.2 Physical Orientation From an accuracy point of view, Eggs DELTA Pulse may be oriented to any position. Make sure that the flow direction arrow points in actual direction of flow. In liquid measurement in a line where air bubble entrapment is likely to take place, meter installation in a vertical run (from bottom to top) is suggested. OUT Flow Direction 5.3 Installation Procedure Rule to follow is to secure a straight pipe longer than 7D upstream of, and 3D downstream of the meter (where D is the nominal meter diameter). See Table 5.1 for actual lengths of straight pipes. To maintain design accuracy observe the following instructions. Table 5.1 Required Straight Pipe Lengths Flow Direction Arrow Fig.5.1 (1) Use tubing which has an inside diameter greater than that of the process connections of meter body. (2) Any device or component having a sharp increase in inside diameter, such as a throttle valve or flared tube, upstream of the flowmeter should be located at least 50 D away. (3) To control the flowrate, provide a flow regulator valve downstream of the meter. IN Nom. Size Inside Dia. D (mm) Upstream Side L1 (mm) Downstream Side L2 (mm) Eggs DELTA Pulse 4 8.5 59 min. 25 min. 8 (PPS) 13 91 min. 39 min. 8 (SCS14A) 8.5 59 min. 25 min. 15 14 98 min. 42 min. 25 24.5 171 min. 73 min. NOTE: See page 9 for Eggs DELTA Pulse pressure losses. L2 D L1 D: Flowmeter Inside Diameter Fig. 5.2 Flow Direction 5

5.4 Flushing If foreign matter is expected to flow into the piping assembly on a new installation, for example, flush the piping assembly thoroughly prior to installing Eggs DELTA Pulse. 5.5 Tubing Connections (1) The meter body is made of resin molding. Exercise care to avoid excessive stress and impact shock while making connections. Shown in the table below is the tightening torque at pipe connections. Nom. Dia. (mm) Tightening Torque Specification (N cm) 4, 8, 15 1960 25 9800 CAUTION 1. Tapered threads are used at connections. So use seals, such as seal tape, for connections. 2. Adhere to the torque specifications above to avoid a broken body with PPS resin connectors. 3. With metal connectors, hold the meter connectors with wrench or similar tool when connecting to the tubing. 4. Do not allow a tool, such as wrench, to come in contact with preamp. Avoid h o l d i n g t h e p r e a m p w h i l e m a k i n g connections to the tubing. (2) If the pipeline cannot support the body, or if the meter is to be installed for some reason in a location subject to strong vibration, secure the body to a rigid foundation, using threaded holes (4-M4) located at back of the body (Fig. 5.3). Fit a rubber spacer sheet between the bracket and foundation in line with the tubing installation dimension (H) and secure the flowmeter body to avoid stress acting on the flowmeter body anchorage (Fig. 5.4). CAUTION: Do not use screws at the back of meter body for metal connector type 25A. Instead, use U-bolts, or similar fittings, to secure the tubing (Fig. 5.5). An example of Installation Fig.5.3 H Preamp Installation Height : Customer to provide Fig. 5.4 Dimensions in mm Example of Metal Coupling 25A Installation Spacer Baseplate Flowmeter Body Preamp Flowmeter Body Metal Coupling 25A Baseplate Spacer U-Bolt Flometer Body Meter Fitting Screw Hole (4-M4, Thread 10 deep) H Installation Height : Customer to provide Fig. 5.5 WARNING 1. Observe the instructions above in making connections with tubing to avoid damage to the body. 2. Do not take off screws (marked ( ) in Fig. 5.4) securing the preamplifier and open up the preamplifier, as which could lead to a damage to it. 6

6. WIRING INSTRUCTIONS Table 6.1 Item Description Signal Cable O.D. 5.9, 3-conductor shielded cable (one meter long furnished) Brown: + White: - Polarities Green: Pulse Output Shield: GND Open-collector unfactored pulse Max. voltage impression: 30VDC Pulse Output Allowable current: 20mA Duty ratio: 1 to 1, approx. Supply Voltage 12 to 24VDC ± 10% Wiring Diagram Signal Cable (one meter long) furnished 3-conductor shielded cable 5.9 in O.D.. BRN (+) Regulated DC WHT (-) Power Supply 12 to 24VDC±10% GRN Pulse Output (open collector) Shield Wire GND Connect shield wire to GND. CAUTION: Do not fail to earth ground the shield wire to GND. Fig.6.1 WARNING It is most important that you observe power line polarities. 7

7. OPERATION (1) Confirm that the process fluid conditions (pressure, temperature, etc.) conform to the ratings of specification. (2) Making sure that there is no leaks in the piping system, progressively open the upstream valve. CAUTION: To prevent adverse influence on associated equipment, avoid sharp increase in flowrate. (3) If the output hunts excessively due to entrapped air in large quantities immediatly after installation, open and close the upstream valve several times to let the air out completely. (4) Making sure of correct wiring connections, turn on power and ensure that no erratic condition is found in the pulse output. 8. TROUBLESHOOTING If Eggs DELTA Pulse operation is erratic, isolate the problem by the table below. Problem Possible Cause Coping Action Flowrate too low. Open the flow regulating valve progressively. Fails to measure. Produces pulses at no flow. Inconsistent flowmeter measurement. Flowrate too high. Flowmeter installed out of position. Exposed to pipeline oscillation. Exposed to noises. Influenced by bubbles (liquid service). Exposed to noises. Tubing conditions are not proper Flowrate controlled upstream of the meter. Progressively closing the flow regulating valve, make sure of pulse output. Make sure of flow direction. Install and support the flowmeter so that its body is isolated from pipeline oscillation. Select an installation location sufficiently away from the noise source. Earth ground the shield wire of signal transmission cable. Let the air out. Review the piping conditions. Earth ground the shield wire of signal transmission cable. Reconfirm the tubing conditions. Control the flowrate downstream of the meter. 8

9. GENERAL SPECIFICATIONS Table 9.1 ITEM DESCRIPTION Model Liquid service Gas service FLP04-L1 A FLP08-L1 A FLP15-L1 A FLP25-L1 A FLP04-G2 A FLP08-G2 A FLP15-G2 A FLP25-G2 A Nominal Diameter and Connection 4mm R3/8 Ext. thd. NPT3/8 Ext. thd. or Rc1/4 Int. thd. 8mm R1/2 Ext. thd. NPT1/2 Ext. thd. or Rc1/4 Int. thd. 15mm R3/4 Ext. thd. NPT3/4 Ext. thd. or Rc1/2 Int. thd. 25mm R1-1/4 Ext.thd. NPT1-1/4 Ext. thd. or Rc 1 Int. thd. Acceptable Fluids Liquid service Gas service Water Air or nitrogen Flow Range (L/min.) Water 0.4 to 4 1.1 to 15 2.8 to 45 8.3 to 133 Atm. Press., air 7.2 to 17 18 to 90 55 to 283 167 to 850 Operating Temperature Range Fluid Ambient -20 to +80 (free from dew condensation) -20 to + 60 C Max. Operating Pressure Accuracy 0.98 MPa Better than ± 3% of full scale Repeatability ± 0.5% Pressure Loss (kpa) Water 0.31 to 31 0.12 to 34.3 Atm. Press., air 0.13 to 0.7 0.06 to 1.52 Major Parts Materials Installation Location Output Power Signal cable Transmission Length Meter body, sensor, preamplifier housing: PPS resin (polyphenylene sulfide) Housing fitting screws: PEEK Wetted parts seals: Flourine rubber Free from rain and water, Minimal temp. change, Free from direct sunlight. Open collector factored pulse Max. voltage impression: 30VDC, Allowable max. current: 20mA, Pulse width: duty ratio 1 to 1 DC 12 to 24V ± 10% Current drain: 10mA max. O.D. 5.9. 3-conductor shielded cable, one meter long furnished BRN: + power, WHT: 0V, GRN: pulse output One kilometer (when cable 2.0mm² in conductor area is used. NOTE: This meter is not compatible with flammable, corrosive, or toxic fluids. 9

Output Units of Measurement (default settings) (1) Liquid Service Model Nominal Dia. (mm) Nom. Pulse Unit (ml/p) Max. Flowrate (L/min) Max. Pulse Output Frequency (Hz) FLP04-L1 A 4 0.08900 4 750 FLP08-L1 A 8 0.4408 15 570 FLP15-L1 A 15 2.363 45 320 FLP25-L1 A 25 12.66 133 180 (2) Gas Service Nominal Dia. Nom. Pulse Unit Max. Flowrate Max. Pulse Output Model (mm) (ml/p) (L/min) Frequency (Hz) FLP04-G2 A 4 0.8900 17 320 FLP08-G2 A 8 4.408 90 350 FLP15-G2 A 15 23.63 283 200 FLP25-G2 A 25 126.6 850 120 NOTE: Nominal pulse units may vary with operating conditions and other factors. Refer to the specification plates found on the sides of the flowmeter. 10. PRODUCT CODE EXPLANATION Item Product Code Model F L P Eggs DELTA Pulse 0 4 4 mm Nominal Size Fluid Kind Frequency Division Process Connection Description 0 8 8 mm 1 5 15 mm 2 5 25 mm L Liquid service G Gas service 1 1/1 Default setting for liquid service 2 1/10 Default setting for gas service 3 1/100 P R external thread Material: PPS resin N NPT external thread Material: PPS resin S Rc internal thread Material: SCS14A Version A Always A Table 10.1 10

11. OUTLINE DIMENSIONS R or NPT External Thread 51 36 Signal Cable One meter long 24 H2 ød L 39 R W H1 4-M4 (Meter Body Fitting Screw Slot) [Unit: mm] Model FLP04 L 1 P A FLP08 L 1 P A FLP15 L 1 P A FLP25 L 1 P A Nominal Diam. 4 8 8 13 15 14 Ø D (Meter I.D.) 25 24.5 R L W H H Approx. Weight [g] (Cable weight incl.) R3/8 Ext. thd. NPT3/8 Ext. thd. 80 32 29 68 270 R1/2 Ext. thd. NPT1/2 Ext. thd. 80 32 29 68 270 R3/4 Ext. thd. NPT3/4 Ext. thd. 85 32 29 68 280 R1-1/4 Ext. thd. NPT1-1/4 Ext. thd. 120 46 46 85 410 Rc Internal Thread 51 36 Signal Cable One meter long 24 H2 ød L 39 W Rc H1 NOTE: Meter body fitting screws cannot be used for FLP25. (See Sec. 5.5 on page 6.) 4-M4 (Meter Body Fitting Screw Hole) [Unit: mm] Model Nominal Diam. Ø D (Meter I.D.) R L W H H Approx. Weight [g] (Cable weight incl.) FLP04 L 1 P SA FLP08 L 1 P SA FLP15 L 1 P SA FLP25 L 1 P SA 4 8.5 Rc1/4 Int. thd. 91 50 29 68 650 8 8.5 Rc1/4 Int. thd. 91 50 29 68 650 15 14 Rc1/2 Int. thd. 91 50 29 68 650 25 24.5 Rc 1 Int. thd. 126 46 46 85 950 11

All specifications are subject to change without notice for improvement. /OVAL 4097 N. Temple City Blvd. El Monte, CA 91731 ph 626.444.0571 fx 626.444.2569 www.sparlinginstruments.com 2011.10 Revised 2001.09 Released IDS FLP S-192-E(1) Manufactured in Japan by Oval Corporation 8/12 12