GLOSSARY OF TERMS, MAXON COLUMNLIFT (BMR)

Similar documents
INSTRUCTION, BMR AUXILIARY CONTROL

M REV. D APRIL 2010 BMR-44 PARTS MANUAL

M REV. K SEPTEMBER Parts Manual Contains: Warranty Information Warnings Parts Ordering Information Exploded View Parts Breakdowns

WDV Series. WDV Series

M MARCH 2002 Parts Manual Contains:

M REV. D DECEMBER Parts Manual Contains: Warranty Information Warnings Parts Ordering Information Exploded View Parts Breakdowns

Parts Manual Contains:

Installation Manual WDV & WDVBG lb. Capacity Rail Liftgates

M REV. C AUGUST 2008

INSTRUCTION, BMR STREET-SIDE CONTROL

ILD PLUS 33, 44, 55, 66

Column gate. Interlift Inc. a member of MBB Palfinger

TC2000. This control box is typically located in the cab of the truck and the cable runs back to the auxiliary plug at the front of the trailer.

M REV. L AUGUST 2012

TDR-44, 55, 66 OWNERS MANUAL/PARTS LIST

Parts Manual HLF 2500, 3000, 4000 & 5000 lb. Capacity Flipaway Liftgates

SL15/20-6 AND SL15/20-10 INSTALLATION INSTRUCTIONS

PARTS MANUAL. ECN-M0XXX Rev. 2.0, Date Part #

TDR-44, 55, 66 OWNERS MANUAL/PARTS LIST

M REV. B FEBRUARY 2016

ILD plus 35, 44, 55, 66

M REV. C AUGUST 2017

Parts Manual EM and EMTC 2500 lb. and 3300 lb. Capacity Flipaway Liftgates

M REV. B AUGUST 2010 INSTALLATION MANUAL GPTWR-3

TT-12 OWNERS MANUAL/PARTS LIST

Owner s Manual. LTS Hide-A-Way Truck Side Gate

M REV. A DECEMBER 2016

WSL-Series. WSL- Series

Tailgates By THIEMAN WT20, 30 & 40 PLEASE READ AND UNDERSTAND THE CONTENTS OF THIS MANUAL BEFORE OPERATING THE EQUIPMENT. HIEMAN

INSTRUCTIONS, FLASHING LIGHT INSTALLATION KIT

PARTS MANUAL. ILD+ 33, 3300 lbs. Capacity ILD+ 44, 4400 lbs. Capacity ILD+ 55, 5500 lbs. Capacity ILD+ 66, 6600 lbs.

SL15/20-6 AND SL15/20-10

Model ET 5000W Operation and Service Manual

MAXON - THE LEADER IN LIFTGATES

INSTALLATION MANUAL RA-35 & RA-45 M REV. D SEPTEMBER 2017

INSTRUCTIONS, NISSAN TITAN TRUCK INSTALLATION KIT (C2 PICKUP LIFTGATES)

RCM-1250 C RCM-1250 C AB RCM-1600 RCM-1600 C AB

M-90-1 REV. F SEPTEMBER 2010 INSTALLATION MANUAL RC-2B RC-3B RC-4B RC-5B RC-6B RC-6K

DIAMOND CONCRETE SAW PARTS LIST MODEL CC8000 P R O D U C T S. (Revised )

Installation Manual WDV & WDVBG

M REV. D APRIL 2008 INSTALLATION MANUAL GPTLR-25, GPTLR-33, GPTLR-44, & GPTLR-55

PARTS MANUAL MODELS. For AST, ATU, FP-3, and SM Model Tuckunder Liftgates

INSTALLATION MANUAL DMD-22 & DMD-33

PRODUCT DOCUMENTATION PARTS PORTAL RAILIFT & DMD MAXON

M REV. M SEPTEMBER 2013

Owner s Manual. SLP Hide-A-Way Tuckunder Style

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

The RCM offers unique flexibility and lifting capacities up to 1600 lbs for your van body, cutaway, step van, platform or stake body.

M REV. M SEPTEMBER 2013

72-25(B & LM) 72-30(B & LM)

Tailgates By THIEMAN M16, 20, 25, 30 MLB16, 20, 25, 30 INSTALLATION INSTRUCTIONS

INSTRUCTION, DODGE TRUCKS INSTALLATION KIT (C2 LIFTGATES)

Installation Manual. LHLP4500G Hide-A-Way Tuckunder Style

M16, 20, 25, 30 MLB16, 20, 25, 30 OWNERS MANUAL/PARTS LIST

Contents Anthony Liftgates, Inc.

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES)

LIFT CORP. CUSTOMER SERVICE: (562) (800) FAX: (888) Slauson Ave. Santa Fe Springs, CA TECHNICAL SERVICE: (800)

Trailer Parts. Brake Components. Axle Components. Suspensions. Lights & Electrical. Wheels & Tires. Loading Ramps. Couplers & Safety Chains

Parts Manual C15, C20, C , 2000, 2500 lb. Capacity Flipaway Liftgates

M REV. A APRIL 2008 INSTALLATION MANUAL

Installation Manual. LPR4500RB Hide-A-Way LPR45RBSR Hide-A-Way Trailer Rear Gate

INSTRUCTIONS, RAM DUAL REAR WHEEL TRUCKS INSTALLATION KIT (C2 LIFTGATES)

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES)

Cantilever Series Mounting Instructions Ram Promaster Extended Body (AH) Present

INSTALLATION INSTRUCTIONS

Trailer Parts. Brake Components. Axle Components. Suspensions. Lights & Electrical. Wheels & Tires. Loading Ramps. Couplers & Safety Chains

SL15/20-6 AND SL15/20-10 OWNERS MANUAL/PARTS LIST

SL4200. This valve operates the gates and is equipped with a manual over ride. This valve is normally closed.

FXD68 Fold-A-Vador Rail Gate

OWNERS MANUAL/PARTS LIST

Installation Manual. LHS & LLBS Hide-A-Way Tuckunder Style

XL3100. This valve operates the gates and is equipped with a manual over ride. This valve is normally closed.

ILT - Series. Troubleshooting: ILT Twinfold Dual Cylinder Folding Unit

M REV. E JUNE 2009 OPERATION MANUAL GPTLR-25, GPTLR-33, GPTLR-44 & GPTLR-55

INSTRUCTION, GPTLR POWER DOWN HAND PUMP KIT

Railgates By THIEMAN VL-30, 40, 50 OWNERS MANUAL/PARTS LIST IMPORTANT! KEEP IN VEHICLE!

2014 Private Use Application Guide Issue Century Series

ILF 33, 44, 55. Auto- Fold PARTS BREAK DOWN. Interlift Inc. dba MBB Palfinger

ILM PARTS MANUAL. INTERLIFT, INC. a member of MBB

ILUK 33, 44, 55, 66. Under Slider PARTS BREAK DOWN. Interlift Inc. dba MBB Palfinger

TE-20 & INSTALLATION MANUAL M REV. F SEPTEMBER 2015

Cantilever Series Mounting Instructions Chevy Express (AD) present

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

ILR 20,25,30 PARTS MANUAL. ECN-M0XXX Rev. 2.2, Date Part #

Installation Manual HLF-25, 30, 40, & , 3000, 4000, & 5000 lb. Capacity Flipaway Liftgates

Tailgates By THIEMAN LRST-40 OWNERS MANUAL/PARTS LIST IMPORTANT! KEEP IN VEHICLE!

Airflex Air Ride Suspension System Installation Instructions

ASSEMBLY MANUAL. 45-Foot Air Double Disc Drill. Amity Technology, LLC th Avenue North Fargo, ND (701)

WARNING TABLE 3-1: DAILY SAFETY CHECK

INSTALLATION MANUAL TE-33, TE-33L & TEWR-33 M REV. K DECEMBER 2016

Patriot. Aluminum and Steel 5spring. Step #1 Tarp Spool with Gear Motor (Includes Instructions for Optional Wind Deflector)

M APRIL 2012 INSTALLATION MANUAL DMD-22 & DMD-33

M OCTOBER 2016

Airflex Air Ride Suspension System Installation Instructions

JD TRIPLE EGRESS TRIPLE EGRESS SECTION

Parts Manual WDV SERIES 3500, 4500, 5500 & 6600 lb. Liftgates

SK2100. This valve operates the gates and is equipped with a manual over ride. This valve is normally closed.

Model 802 Center Mount Adapter For New Holland 9030 & TV140 Bi-Directional Tractors PARTS CATALOG

Railgates By THIEMAN TVL 125, TVL 16, TVL 125A, TVL 16A OWNERS MANUAL/PARTS LIST IMPORTANT! KEEP IN VEHICLE!

M JULY 2017 GPTLR Liftgate www. maxonlift.com PRODUCTS, TUK-A-WAY GPTLR Maintenance Manual PRODUCT DOCUMENTATION PARTS PORTAL TUK-A-WAY GPTLR

Transcription:

GLOSSARY OF TERMS, MAXON COLUMNLIFT (BMR) 1. STRUCTURAL COMPONENTS: 6 Fixed Ramp A 6 Fixed Steel Ramp that attaches to the Folding Section of a two piece Platform or attaches to the Main Section of one piece Platform. The 6 Fixed Ramp is used for transition from ground to platform and return. 12 Fixed Ramp A 12 Fixed Steel Ramp that attaches to the Folding Section of a two piece Platform or attaches to the Main Section of one piece Platform. The 6 Fixed Ramp is used for transition from ground to platform and return. 12 Ramp/Cart Stop A 12 fixed steel Ramp with built in Cart Stop. The 12 Ramp/Cart Stop can be either single or dual control stops. The Cart Stop is used for holding back carts and pallets in the retention mode and transition from ground to platform and return. 16 Aluminum Ramp A 16 Aluminum hinged Ramp with retention capability. The 16 A.R.R. is used for holding back carts and pallets in the retention mode and also for transition from ground to platform and return. Chain Anchor The Chain Anchor is attached to the end of the Platform on the side. The Platform Chains are attached via an H Connector. Closing Cylinder The Platform Closing Cylinder is attached to the Runner and the Inside Coupling. This cylinder is used, when activated, to open and close the Platform. Column Assembly The upright columns fixed to either the Trailer or Truck Body Corner Posts. Column and Runner Assemblies combined with all subassemblies included. Extension Plate The Extension Plate is attached to both Column Assemblies and to vehicle floor. Spacing between vehicle floor and folded platform sections. Foldover Section The Foldover Section is the second part of the platform section. This section is attached to the Main Section with hinges and folds for storing. The usual size is 80 wide by 30, 36 or 42 deep. Any folding Section that is equal to the Main Section the Platform (30 X 30 ; 36 x 36 ; 42 X 42 ) should use the 16 Aluminum Retention Ramp Option. PAGE 1

Greaseless Bushing All pivot points have Greaseless Bushings. No grease is required when using this type of bushing. Inside Coupler RH Coupler attached to the Closing Cylinder and connected to the Runner Assembly via the Platform Pin. Inside Coupler is also bolted to Platform Pin. Lift Cylinder A Lift Cylinder is part of the Column Assembly. The Cylinder is between the Runner and Column Guide and is attached to the Runner and Column with 1 pins. The Lift Cylinder, when activated, is part of the Hydraulic System used to raise the Platform. Main Section The Main Section is the section attached to the runners and is the first part of the Platform. The usual size is size is 80 wide by 42 deep. For 102 wide applications, the size would be 86 wide by 42 deep. For low bed height applications, the Main Section can be 80 wide and 36 or 30 deep. Opener Weldment Perpendicular upright Weldment attached to the Main Section on a pivot point. The upper end has a chain fastener and a chain link catcher. The Opener Weldment is used to unfold the Foldover Section of the Platform. The Chain Link Catcher is used to hold the Chain in the stored position. Outside Coupler RH Coupler attached to the Main Section of the Platform with a special small-head bolt and connected to the Inside Coupler RH via the Platform Pin. Platform Platform is usually made up of two sections. The Main Section and the Folding Section. The Platform is the flat loadable surface area. For example: 80 wide by 72 deep. Platform Pins Pins used to connect the Platform, through the Couplers, to the Runner Assembly. Ramps Ramps are attached to the Platform to allow access to the Platform from the ground. Several types of Ramps include: 6 fixed steel Ramp; 12 fixed steel Ramp; 12 fixed Ramp with built-in Cart Stop (single or dual stops); and 16 Aluminum Retention Ramp. PAGE 2

Rollers and Axles Plastic Rollers with greaseless roller bearings attached to Axles in the Tandem Assembly. The Rollers roll on the Roller Guides welded to the front and back inside surface of the Column. Runner Assembly The Runner Assembly (including Runner, tandem assemblies, plastic slides, etc.) is inside the Column, and Runner is attached to the Main Section of the Platform and to the Lift Cylinder. Tandem Assembly The Tandem Assembly consists of Plastic Rollersattached to two tandem plates. Used to guide the runner up and down the column. Tear Drop Assembly The Tear Drop Assembly attaches to the Runner Assembly and is connected to the Chain via an H Connector. This allows the Chain to fold into the Opener Weldment and Chail Link Catcher. 2. HYDRAULIC COMPONENTS: A Valve The A Valve is a 2-Position Normally Closed Solenoid Valve. It is located on the Manifold Block and controls the OPEN/CLOSE function of the Platform. On 1997 Model BMR s, the Manifold Block is labeled A. Auxiliary Hand Pump The Auxiliary Hand Pump (also known as Emergency Hand Pump) is a manual pump to raise or lower Platform manually if the Hydraulic System is still intact. B Valve The B Valve is a 2-Position Normally Closed Solenoid Valve. It is located on the Manifold Block and controls the RAISE/LOWER function of the Platform. On 1997 Models, the Manifold Block is labeled B. C Valve The C Valve, on pre-1997 Model BMR s, is a 2-Position Normally Closed Solenoid Valve located in the C Valve Body on the back wall of the Pump Enclosure. On the 1997 Model BMR s, the C Valve is a 4-Way/2-Position Spool Valve located in the Manifold Block and labeled C. The C Valve allow hydraulic fluid to flow back to the Reservoir faster. In Power Down Models, it reverse the flow of fluid to the Lifting Cylinders. Cartridge Valve A Cartridge Valve is either a 2-Position Normally Closed Solenoid Valve acting as a check (holding) valve or a 4-Way/2-Position Spool Valve used to change direction of fluid flow to Lifting Cylinders or flow between ports on Manifold Block. PAGE 3

Cartridge Valve A Cartridge Valve is either a 2-Position Normally Closed Solenoid Valve acting as a check (holding) valve or a 4-Way/2-Position Spool Valve used to change direction of fluid flow to Lifting Cylinders or flow between ports on Manifold Block. Closer Valve Adjustment The Closer Valve Adjustment is a Pump adjustment that controls the CLOSE speed of the Platform on 1997 Model BMR s. The adjustment, labeled C, is located on top of the Manifold Block. D Valve The D Valves (also called Lock Valves) are 2-Position Normally Closed Solenoid Valves with manual override. A D Valve is located in the D Valve Body on top of each Lifting Cylinder. Drive Plate The Drive Plate is a rectangular steel block attaching Motor, Pump, Pump Enclosure and hydraulic fluid Reservoir. Dual Pump Assembly The Dual Pump Assembly is two Pump Assemblies combined with a common Hydraulic Fluid Reservoir. The second Pump, with its own Motor, Motor Solenoid, Manifold Block and Valves can function as an emergency or auxiliary electrical Pump. E Valve The E Valve is a 4-Way/2-Position Spool Valve located in the Manifold Block. This valve allows the flow of hydraulic fluid to change from Lifting Cylinders to Closing Cylinder. On 1997 Model BMR s, the Manifold Block is labeled E. Flow Control Valve The Flow Control Valve is a one-direction control needle-type valve. The arrow on the valve body shows the direction the flow is controlled. Used on the pre-1997 Model BMR s to control the OPEN/CLOSE speed of the Platform. Gravity Down The Pump Assembly is wired and plumbed to lift with hydraulic pressure and lower by the weight of the Platform under gravity. In-Line Filter The In-Line Filter is located on the Hydraulic Fluid Reservoir Tank and connected to the C Valve Block on the back wall of the Pump Enclosure. The In-Line Filter was used on 1995 and 1996 Model BMR s. Manifold Block The Manifold Block is an aluminum block with ports drilled to allow Solenoid Valves to be used to direct or restrict flow of hydraulic fluid. PAGE 4

Motor The Motor is a 12 Volt, Heavy-Duty Prestolite Motor. The Motor is attached to the Drive Plate of the Pump Assembly. Motor Solenoid The Motor Solenoid is the 12 volt starting switch for the Motor. The Motor Solenoid is attached to the Motor. Needle Valve The Needle Valve is a two-direction control, needle-type valve. Used on all BMR models to control flow while using an Emergency Hand Pump. Opener Valve Adjustment The Opener Valve Adjustment is a Pump adjustment to control the OPEN speed of the Platform on 1997 Model BMR s. The adjustment, labeled O, is located on top of the Manifold Block. Pick Up Filter Located inside the Reservoir and attached to the Pump, the Pick Up Filter is used to filter out the larger contaminants before hydraulic fluid enters the Pump. Port A hole (or outlet) for connecting either a Cartridge Valve or Hydraulic Hose. Port may be on the Manifold Block, Drive Plate or Cylinder. Power Down The Pump Assembly is wired and plumbed to lift and lower Platform with hydraulic pressure. Pump The Pump is a gear-driven hydraulic pump located inside the Reservoir and attached to the Drive Plate. Pump Assembly Consists of the Motor, Motor Solenoid, Pump, Reservoir, Drive Plate, Manifold Block and Cartridges Valves used for the this model of liftgate. Pump Enclosure The steel box used to house the Pump Assembly and supporting components such as Batteries, Circuit Breakers, Master Disconnect (for battery power) and Emergency Hand Pumps. Pump Relief Valve The Pump Relief Valve is located on the side of the Drive Plate of the Pump Assembly. The Pump Relief Valve controls the pressure of the pump. Relief Valve The Relief Valve is a 2400 PSI valve located in the C Valve Body on pre-1997 Model BMR s. On 1997 Model BMR s, the Relief Valve is located on the Manifold Block. The Relief Valve controls pressure to Ride Equalizer and the Cylinders. PAGE 5

Ride Equalizer The Ride Equalizer is a gear-driven hydraulic fluid flow divider. The Ride Equal izer is in line with the Raise Port in the Hydraulic System. Solenoid Coil A Solenoid Coil is a 12 volt magnetic coil used to open or close a Cartridge Valve. Solenoid Valve A Solenoid Valve consists of a Cartridge Valve (2-Position/Normally Closed Solenoid Valve or a 4-Way/2-Position Spool Valve) and a 12 volt Solenoid Coil. Spin On Filter The Spin On Filter is located on the back wall of the Pump Enclosure. It filters 100% of the hydraulic fluid returning to Reservoir. The Spin On Filter is used on 1997 Model BMR s. 3. ELECTRICAL COMPONENTS: Ride Equalizer The Ride Equalizer is a gear-driven hydraulic fluid flow divider. The Ride Equal izer is in line with the Raise Port in the Hydraulic System. 3-Wire Extension The 3-Wire Extension is used on Trailer Applications. It extends the D Valve Wiring Harness to the Pump Enclosure. Comes in ten foot lengths. 4-Pin Connector The 4-Pin Connector is the connector for the wiring harness of the Inside Control Switch. On pre-1997 Model BMR s, connector is located inside the Pump Enclosure. On 1997 Models, the 4-Pin Connector is located on the outside wall of the Pump Enclosure. 4-Wire Extension The 4-Wire Extension is used on Trailer Applications. Extends the Inside Control Wiring Harness to the Pump Enclosure. Comes in ten foot lengths. 5-Pin Connector The 5-Pin Connector is the connector for the wiring harness of the Outside Control Switch. On pre-1997 Model BMR s, connector is located inside the Pump Enclosure. On 1997 Models, the 5-Pin Connector is located on the outside wall of the Pump Enclosure. 5-Wire Extension The 5-Wire Extension is used on Trailer Applications. Extends the Outside Control Wiring Harness to the Pump Enclosure. Comes in ten foot lengths. PAGE 6

Charge Line The Charge Line is usually found on Trailers. Charge Line runs between the Batteries, through a 150 amp Circuit Breaker, and the Trailer Single Pole Plug at the nose of the Trailer. When connected to the Tractor electrical charging system via another Single Pole Plug, batteries installed on the Trailer can be charged. Circuit Breaker Electrical circuit protection device. The most common is 150 amp manual reset Circuit Breaker. Should be used in the charging circuit, only. (Should not be used between Motor Solenoid and Batteries.) Hand Held Control The Hand Held Control is a walk-around control wired (via T Connector) to the Inside Control 4-Pin Connector. Inside Control Three-piece Wiring Harness that travels with the Runner Assembly. Switch is used for operating liftgate UP or DOWN. Master Disconnect Electrical safety device. Manually removes battery power to prevent Pump Assembly from operating. Outside Control Small electrical box containing the Outside Control (switches for operating liftgate UP/DOWN and OPEN/CLOSE). Power Line The Power Line provides electrical power from vehicle batteries to the Pump Assembly (on liftgate) when liftgate is not equipped with separate batteries. Stationary Control A Stationary Control is used, instead of the Three-piece Wiring Harness, for operating liftgate UP/DOWN from the inside position. T Connector The T Connector is a T-shaped adapter with a connector on each leg (3 connectors). Typically, this adapter is used to connect D Valve wiring and add-on controls (such as Hand-held Control) to liftgate main wiring harness. Tractor Line The Tractor Line is a source of vehicle battery power for liftgate and for charging separate liftgate batteries. The Tractor Line is routed from Tractor charging system (or batteries) to liftgate through a Tractor-mounted Single-Pole Plug, Trailer-mounted Single Pole Plug, and 150 amp Circuit Breaker. The Tractor Line consists of two electrical cables - one positive (+) polarity and one negative (-) polarity. PAGE 7